Tender For Construction Of Assistant Labour Officer Building At Kashipur Block In The District Of Rayagada For The Year 2026-27.
Tender Value
2.13 Crore
Estimated cost
Bid Submission
28 Aug 2026
10 days left
EMD
2.13 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rayagada → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Assistant Labour Officer Building At Kashipur Block In The District Of Rayagada For The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment) including cost of all materials, labour, T&P etc complete in all respect and as per direction of the Engineer-in-charge.Ground Floor |
| 2 | Watchman Shed |
| 3 | Earth work in excavation of foundation in all kinds of soil including hard moorum, stoney earth mixed with doublers (except sheet rock and boulders requiring blasting) with all leads & lifts including dressing & leveling the bed & depositing the excavated earth at places away from work site with all leads & lifts including Cess and cost of all labour T&P & dewatering if required for the work etc. complete and as per specification and direction of Engineer-In-ChargeGround Floor |
| 4 | Compound wall |
| 5 | Watchman Shed |
| 6 | Internal Road |
| 7 | Drain |
| 8 | Supplying and filling in foundation & plinth with sand in 23.5 cm (9\\") thick layers including watering and ramming with cost, conveyance, Royalty, DMF, EMF & Additional Charges of all materials, and labour with T&P required for the work including Cess etc complete. (Measurement will be taken on finished compacted section only) as per direction of Engineer-in-Charge.Ground Floor |
| 9 | Compound wall |
| 10 | Watchman Shed |
| 11 | Internal Road |
| 12 | Drain |
| 13 | Providing cement concrete of proportion (1:3:6) in foundation and floors using 4cm (3/2\\") size clean hard black hand broken granite stone metal of approved quality and from approved quarry including hoisting lowering and laying concrete in layers not exceeding 15cm (6\\") thick to the required level ramming, watering & Curing etc. complete including cost & conveyance of all materials with all Royalty, DMF, EMF & Additional Charges and all labour with T&P required for the work with Cess etc, complete including dewatering if required as per direction of Engineer In Charge. Ground Floor |
| 14 | Compound wall |
| 15 | Watchman Shed |
| 16 | Providing Plain cement concrete of (1:2:4) using 12mm and down graded size hard granite stone aggregate including cost and conveyance of all materials to site, and all labour charges complete including cost, conveyance, Royalty, DMF, EMF & Additional Charges , , labour, Cess & T&P & all other materials required for the work complete as per the direction of the Engineer-in-charge.Ground Floor |
| 17 | Compound wall |
| 18 | Watchman Shed |
| 19 | Providing cement concrete of proportion (1:4:8) in foundation and floors using 4cm (3/2\\") size clean hard black hand broken granite stone metal of approved quality and from approved quarry including hoisting lowering and laying concrete in layers not exceeding 15cm (6\\") thick to the required level ramming, watering & Curing etc. complete including cost & conveyance of all materials with all Royalty, DMF, EMF & Additional Charges and all labour with T&P required for the work with Cess etc, complete including dewatering if required as per direction of Engineer In Charge. CC Drain |
| 20 | Fly Ash brick masonary in Cement Mortar (1:6) in foundation & Plinth using-fly ash-brick of 23cm X 11cm X 8cm size having a crushing strength in between 75kg to 100 kg per Sq.cm with dimensional tolerance ± 8% including splays cutting circular moulding chamfering & corbelling watering and curring for 7days after immersing the bricks in water for six hours before use etc. complete including cost & conveyance of all materials & labour required for the work with all Royalty, DMF, EMF & Additional Charges with all T&P & Cess etc, complete in all respect as per the direction of Engineer-in-charge. Ground Floor |
| 21 | Compound wall |
| 22 | Watchman Shed |
| 23 | Fly Ash brick masonary in Cement Mortar (1:6) in Superstructure using-fly ash-brick of 23cm X 11cm X 8cm size having a crushing strength in between 75kg to 100 kg per Sq.cm with dimensional tolerance ± 8% including splays cutting circular moulding chamfering & corbelling watering and curring for 7days after immersing the bricks in water for six hours before use etc. complete including cost & conveyance of all materials & labour required for the work with all Royalty, DMF, EMF & Additional Charges with all T&P & Cess etc, complete in all respect as per the direction of Engineer-in-charge. Ground Floor |
| 24 | First floor |
| 25 | Head Room |
| 26 | Compound wall |
| 27 | Watchman Shed |
| 28 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost & conveyance of all materials & labour required for the work with all Royalty, DMF, EMF & Additional Charges with all T&P & Cess etc, complete in all respect as per the direction of Engineer-in-charge. Ground Floor |
| 29 | First floor |
| 30 | Watchman Shed |
| 31 | R.C.C. work ofproportion(1:1:5:3) using 20mm size hard black crusherbroken granite stone chips of approved quality and from approved quarry including hoisting, lowering, laying & compacting concrete, watering and curing for 4 weeks, centering, shuttering & finishing the exposed surface smooth to recieve painting or white or colour wasing providing grooves or beads where neCessary with cost, conveyance, Royalty, DMF, EMF & Additional Charges andof all materials and labour with T&P Cess required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charge for straightening, cutting, bending, binding etc. of the M.S. Rods or Tor steel and binding wire and laying the grills and placing in proper position etc complete and as per specification & direction of Engineer-in-charge Ground FloorFooting |
| 32 | Column |
| 33 | Plinth beam |
| 34 | Lintel |
| 35 | Roof beam |
| 36 | Roof slab |
| 37 | Chajja |
| 38 | Stair case |
| 39 | Shelves |
| 40 | Drain |
| 41 | First FloorColumn |
| 42 | Lintel |
| 43 | Roof beam |
| 44 | Roof Slab |
| 45 | Chajja |
| 46 | Stair case |
| 47 | Head RoomColumn |
| 48 | Chajja |
| 49 | Roof slab |
| 50 | watchman ShedFooting |
| 51 | Column |
| 52 | Plinth beam |
| 53 | Lintel |
| 54 | Roof beam |
| 55 | Roof slab |
| 56 | Chajja |
| 57 | Shelves |
| 58 | Compound wallFooting |
| 59 | Column |
| 60 | Plinth beam |
| 61 | Roof beam |
| 62 | Providing 2.5cm thick grading concrete (1:2:2) on roof slab using 6mm size hard broken granite chips with chicken mesh including cost, conveyance, Royalty, DMF, EMF & Additional Charges of all materialsof all T&P with Cess etc, required for the work etc completein all respect as directed by Engineer-in-charge.Ground Floor |
| 63 | First Floor |
| 64 | Head Room |
| 65 | watchman Shed |
| 66 | Straightening bent up or coiled rods cutting bending,binding, cranking hooking, welding jointing (if required) the M.S.Rods or Tor steel & binding wires and binding tying the grills hoisting lowering & placing in proper position as required for RCC works with cost conveyance &of M.S. Rods or Tor steel & binding wires of 18 to 20 gauge and labour with all T&Prequired for the work with Cess etc,complete in all floors (weight of binding wire will not be considered for payment and payment will be made on weight of M.S. Rods or Tor steel only) etc. in all respects as per the direction of Engineer-in-Charge. Ground Floor |
| 67 | First Floor |
| 68 | Head Room |
| 69 | Compound wall |
| 70 | watchman Shed |
| 71 | Drain |
| 72 | 12mm (1/2\\") thick cement plaster in C.M (1:6) finsihed smooth to out side brick walls after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and laobur with T&P required for the work with all , Royalty, DMF, EMF & Additional Charges & Cess etc, complete in all floors as per direction of Engineer-in-charge. Ground Floor |
| 73 | First Floor |
| 74 | Head Room |
| 75 | Compound wall |
| 76 | watchman Shed |
| 77 | 16mm (5/8\\") thick cement plaster in C.M. (1:6)finished smooth to inside surface of 9\\" thick brick wall after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and labour with T&P required for the work with all , Royalty, DMF, EMF & Additional Charges & Cess etc, complete in all floor as per direction of Engineer-in-charge. Ground Floor |
| 78 | First Floor |
| 79 | Head Room |
| 80 | watchman Shed |
| 81 | 6mm thick cement plaster in cement mortar (1:4) to ceilling of roof lintel and chajjas after chipping and chiselling the same and clearing the surface by wire brush finished smooth watering and curing for 7 days including cost,conveyance of all materials and labour with T&P & Cess required for the work withand Royalty, DMF, EMF & Additional Charges etc complete in all respects in all floors as per direction of Engineer-in-Charge. Ground Floor |
| 82 | First Floor |
| 83 | Head Room |
| 84 | watchman Shed |
| 85 | Supplying,fitting & fixing vitrified tile in floors of size 600mm x 600mm of approved make conforming to IS:13755 laid on 20mm thick cement mortar (1:4) (1 Cement : 4 Course Sand) and filling joints with white cement of approved quality including with cost, conveyance,Royalty, DMF, EMF & Additional Charges ,of all materials & labour T&P and Cess required for the work all complete as per direction ofEngineer-In-Charge. (For New Work only)Ground Floor |
| 86 | First Floor |
| 87 | watchman Shed |
| 88 | Providing, fitting & Fixing vitrified tile in dado, skirting and rises of steps on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including with cost, conveyance,Royalty, DMF, EMF & Additional Charges ,of all materials & labour T&P and Cess required for the work all complete as per direction ofEngineer-In-Charge.Ground Floor |
| 89 | First Floor |
| 90 | watchman Shed |
| 91 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4) and filling joints with slurry including with cost, conveyance,Royalty, DMF, EMF & Additional Charges ,of all materials & labour T&P and Cess required for the work all complete as per direction ofEngineer-In-Charge.Ground Floor |
| 92 | First Floor |
| 93 | watchman Shed |
| 94 | Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including with cost, conveyance,Royalty, DMF, EMF & Additional Charges ,of all materials & labour T&P and Cess required for the work all complete as per direction ofEngineer-In-Charge.Ground Floor |
| 95 | Finishing wall surface of walls with Acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materialslabour T&P & Cess etc complete as per direction of EIC. Ground Floor |
| 96 | First Floor |
| 97 | watchman Shed |
| 98 | Priming one coat with any approved primer over iron work including cost of primer with sand papering, polishing the surface in all respectwith cost, conveyance andof all materials and labour with T&P and Cess required for the work etc. complete in all respect as per direction of Engineer-in-Charge.Ground Floor |
| 99 | First FloorExternal wall |
| 100 | Internal wall |
| 101 | Head RoomExternal wall |
| 102 | Internal wall |
| 103 | watchman Shed |
| 104 | Compound wall |
| 105 | Wall painting two coats with plastic emulsion paint of approved quality & shade on new work to give an even shade with brush to interior walls suraface after cleaning the surface including cost of plastic emulsion paint with cost, conveyance andof all materials and labour with T&P required for the work with Cess etc complete as per direction of Engineer-in-chargeGround floor |
| 106 | First floor |
| 107 | Head Room |
| 108 | watchman Shed |
| 109 | Finishing wall surface two coats with any approved weather shield cement paint over a coat of oil bound primerto outer wall surface after celaning surface including cost of paint and primer watering curing with cost conveyance andof all materials and labour with T&P and Cessrequired for the work etc, complete in all respect as per the direction of Engineer-in-Charge. Ground floor |
| 110 | First floor |
| 111 | Head Room |
| 112 | watchman Shed |
| 113 | Compound wall |
| 114 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, taxes, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-ChargeGround floor |
| 115 | First floor |
| 116 | Head Room |
| 117 | watchman Shed |
| 118 | Compound wall |
| 119 | Supplying fitting of Stainless steel of 304 garde in hand railing using 50 mm dia of 2 mm thick circular pipe with balustarade of size 32mm X 32 mm X X2 mm in 3 rows in stair case as per approved design and specification buffering polisging etc. including cost conveyance of all materials complete as per direction of the Engineer- in - Charge.Ground floor |
| 120 | First floor |
| 121 | Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primer & labour to give an even shade etc. complete.Ground floor |
| 122 | First floor |
| 123 | Head Room |
| 124 | watchman Shed |
| 125 | Compound wall |
| 126 | Painting two coats with any approved paint over a coat of priming to new wood work and iron work including cost of the primer and paints including and papering, polishing the surface in all respect with cost, conveyance andof all materials and labour, Cess with T&P required for the work etc. complete in all respect.Ground floor |
| 127 | First floor |
| 128 | Head Room |
| 129 | watchman Shed |
| 130 | Compound wall |
| 131 | Supplying, fiting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitting and fixture etc. complete Ground floor |
| 132 | First floor |
| 133 | watchman Shed |
| 134 | Supplying, fitting and fixing in position well dressed and well seasoned sal wood work framed and fixed (wrought and put up) in choukaths for doors, windows and ventilators including cost of iron work and coal taring 2 coats to wall side faces of choukaths including cost of coaltar, cutting grooves and mending to sizes where neCessary with cost and conveyance Royalty, DMF, EMF & Additional Charges andof all materials and labour, Cess with T&P required for the work etc. complete in all respect as per direction of Engineer-In-Charge. Ground floor |
| 135 | First floor |
| 136 | watchman Shed |
| 137 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD.) Ventilator/ Top Hung 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638 14,EN 477-95 and other applicable codes and standards.-Ground floor |
| 138 | First floor |
| 139 | watchman Shed |
| 140 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.Ground floor |
| 141 | First floor |
| 142 | watchman Shed |
| 143 | Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures.Ground floor |
| 144 | First floor |
| 145 | Construction of embankment with approved material obtained from borrow ptis with all lead and lifts transporting to site by machanical means within a lead of 5Kms spreading,grading to required slope and compacting to meet requirements of table 300-2 & clause 305 of MOSRT & H specification including Royalty, DMF, EMF & Additional Charges charges and cost of all materials labour charges,machineries, T&P Cess etc required for the work complete as per direction of E.I.CGround floor |
| 146 | Construction of granular sub-base by providing stone screening, spreading in uniform layer with mortor graded on prepared surface, mxing mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density etc. complete as per clause 401 of MoSRT&H specification for road and bridge work (4th revision) including cost conveyance and Royalty, DMF, EMF & Additional Charges of all materials with all labur T&P Cess etc complete and as per direction of Engineer-in-Charge.Internal Road |
| 147 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. Internal Road |
| 148 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018.Internal Road |
| 149 | Electricals WorkWiringRecessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) |
| 150 | -do- Group B |
| 151 | -do- Group C |
| 152 | Recessed wiring to Fan Point in... -do- Group B |
| 153 | -do- Group C |
| 154 | Recessed wiring to Call Bell Point in... -do- Group B |
| 155 | Recessed wiring to Exhaust Fan Point in do Group B |
| 156 | -do- Group C |
| 157 | S/F of Angle holder replacing Ceilling Rose |
| 158 | S/F of fan hook 'S' type made of 16 mm MS rod for fixing in the Existing RCC Roof. |
| 159 | Switch BoardsS/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4) |
| 160 | S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required. |
| 161 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required |
| 162 | S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket & 20Amp AC Starter , connection, painting etc as required for AC |
| 163 | S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover. |
| 164 | S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection. |
| 165 | S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 2 Modular box with base & cover |
| 166 | 4 Modular box with base & cover |
| 167 | 8 Modular box with base & cover |
| 168 | 12 Modular box with base & cover |
| 169 | Sub-MainWiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) 2x1.5+1x1.5 (1.8.1) |
| 170 | 2x2.5+1x1.5 (1.8.2) |
| 171 | 2x4+1x1.5 (1.8.3) |
| 172 | 4x10+2x4(1:8:11) |
| 173 | Inverter wiring (1x2.5smm) Copper wire (1.19.11A) |
| 174 | Circuit Breakers & BDBS/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1) |
| 175 | S/F of 'B/C/D' series DP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)+(2.3.1b) |
| 176 | S/F of 'C' series 4 Pole MCB of 63A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box. |
| 177 | Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.)S/F of 6 way (6+18) TPN MCB DB double door (2.5.6) |
| 178 | EarthingEarthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2) |
| 179 | Supply & laying 8 SWG Cu wire in recess for loop earthing as required (3.18) |
| 180 | S/L of 25mm x 6mm G.I. earth strip in ground(3:10) |
| 181 | FittingsProviding & fixing plain 16/0.2mm twin twisted flexible, FR PVC insulated copper cable in polythene sleeve or conduit of suitable size on the floor/wall or side of the table/door etc as required.(1.31) |
| 182 | S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB) |
| 183 | S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30) |
| 184 | S/F of 18-25 wt. LED single strip tube. Light fittingwith all accessories & connection (make Havels/HPL/Crompton/Polycab/PAC) |
| 185 | S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS) |
| 186 | Fixing /I.T.C. of stepped type Modular regulator (1.25a) |
| 187 | S/F of 20mm dia down rod with all accessories (1.39+1.41) |
| 188 | S/F of 400mm Wall fan with all accessories and connections (Make-Usha-Maxx Air Ultra/Polycab-Arey HS/Cropmton-WM Hiflowave/ Havells-Accelero HS/ Anchor-Altrix HS- OWH/ Orient-Wall43/ Great White-WYNO WF) |
| 189 | S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells ) |
| 190 | S/F of 12w Watt LED Bulb |
| 191 | S/F of 1.5T ,5Star,Inverter model, Split A.C Machine (Make- Hitachi(V518PCBISH1)/Blue star(V518PCBISH1C)/Carrier(CAI19CE5R35F0)/Daikin/LG/Mitsubishi/O-General) |
| 192 | S/F of 2T ,5 Star,Inverter model, Split A.C Machine(Make- Hitachi(V522PCBISH1)/Blue star(IC524DNUR)/Carrier(CAI24CE5R35F0)/Daikin/LG/Mitsubishi/O-General) |
| 193 | S/F of 12W LeD Squre (10\\"×10\\") LSDSMN-12W-WW with surface Panel rings (Havels/crompton/philips/panasonic) |
| 194 | S/F of 18W LeD Squre (12\\"×12\\") LSDSMN-12W-WW with surface Panel rings (Havels/crompton/philips/panasonic) |
| 195 | S/F of 2000VA/24V Invertor machine,Make-Heavy duty V-Turbo UPS-23509 (microtek)/PRIME 2250(V-GUARD)/EVO S 2300(LUMINOUS) and 180Ah tall tubular BatteryMake-Luminous /microtek/v-guard and 16A Delux plug Top with Luminous single Trolley for Inveryor Battery,2nos |
| 196 | Supply & fixing of 160 A TPN Panel board 1. 160A MCCB(Make-L&T/Legrand/Seimens/C&S)& 160A,415V Kit-Kat fuse,Bus-BarMake-Havells -3nos2. 100A TPN MCB(Make- L&T/Legrand/Seimens/C&S)- 3nos 3. 32A DP MCB(Make- L&T/Legrand/Seimens/C&S)- 6 nos 4. 100 A 4P Manual changeover (Make- Legrand/Seimens/L&T/C&S/)- 1nos5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad) |
| 197 | Provision of Armoured cable size 3 1/2 x70sqmm (27) |
| 198 | Laying of MV cable above 25sqmm to 120 sqmm in ground (5.1.2) |
| 199 | Laying of MV cable above 25sqmm to 120 sqmm on surface (Horizontally)(5.5.2) |
| 200 | S/M of end termination of LV/MV cable size 3 1/2 x70 sqmm (5.8.23) Please Enable Macros to View BoQ information |
| 201 | S/M of end termination of LV/MV cable size 3 1/2 x70 sqmm (5.8.23) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender