Tender for Supply Of Mcb, Mccb & Rccb For Phase-I&Ii, Stage-I, Ctpp, Chhabra , Mcb Suitable For Din Rail Type 3 Pole, 415Vac, Breaking Capacity= 10 Ka, B Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 10000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type 3 Pole, 415Vac, Breaking Capacity 10Ka, C-Curve , Mcb Suitable For Din Rail Type 4 Pole, 415Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type2 Pole, 240 Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (5-10)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mccb, Three Pole, Thermal Magnetic Trip, Ue=415Vac,50 Hz,Icu=25Ka,Ui=750V,Uimp=8Kv,Ics=100% Icu, Adjustable Overload And Adjustable Short Circuit Setting , Mccb, Four Pole, Thermal Magnetic Trip, Ue=415Vac,50 Hz,Icu=25Ka,Ui=750V,Uimp=8Kv,Ics=100% Icu, Adjustable Overload And Adjustable Short Circuit Setting , Mcb Suitable For Din Rail Type4 Pole, 415Vac, Breaking Capacity= 10 Ka, B Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type1 Pole, 240 Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (5-10)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb-Dc Suitable For Din Rail Type 2 Pole, 220 Vdc, Breaking Capacity= 10 Ka, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-2-2003 , Rccb Suitable For Din Rail Type 2 Pole, Un = 240 Vac, 50 Hz, Ip40, Residual Operating Current Iδn = 30 Ma, Instantaneous Tripping Time At Iδn 40 Ms, Im = Iδm 500 A, Inc = Iδc ≥ 6 Ka, Insulation Voltage 660 Vdc, Type A, Power Supply = Top/Bottom, Terminal Capacity Min/Max = 1.5/25 Mm², With Test Button, Confirming To Is 12640-1:2008 , Rccb Suitable For Din Rail Type 4 Pole, Un = 415 Vac, 50 Hz, Ip40, Residual Operating Current Iδn = 30 Ma, Instantaneous Tripping Time At Iδn 40 Ms, Im = Iδm 500 A, Inc = Iδc ≥ 6 Ka, Insulation Voltage 660 Vdc, Type A, Power Supply = Top/Bottom, Terminal Capacity Min/Max = 1.5/25 Mm², With Test Button, Confirming To Is 12640-1:2008 , Mcb, Rated Voltage:-230Vac Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka , Current Rating:-1Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-1P , Current Rating:-3Amp No.Of Pole:-1P , Current Rating:-4Amp No.Of Pole:-1P , Current Rating:-6Amp No.Of Pole:-1P , Current Rating:-10Amp No.Of Pole:-1P , Current Rating:-16Amp No.Of Pole:-1P , Current Rating:-32Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-2P , Current Rating:-4Amp No.Of Pole:-2P , Current Rating:-6Amp No.Of Pole:-2P , Current Rating:-10Amp No.Of Pole:-2P , Current Rating:-16Amp No.Of Pole:-2P , Current Rating:-20Amp No.Of Pole:-2P , Current Rating:-32Amp No.Of Pole:-2P , Current Rating:-40Amp No.Of Pole:-2P , Mcb, Rated Voltage:-220Vdc Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka , Current Rating:-2Amp No.Of Pole:-1P , Current Rating:-4Amp No.Of Pole:-1P , Current Rating:-6Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-2P , Current Rating:-4Amp No.Of Pole:-2P , Current Rating:-6Amp No.Of Pole:-2P , Current Rating:-10Amp No.Of Pole:-2P , Current Rating:-16Amp No.Of Pole:-2P , 6A Mcb With Auxiliary Contact 1No+1Nc, Rated Voltage:-220Vdc Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka Current Rating :-6Amp No.Of Pole:- 2P

BOQ

Name of Work:- Supply of MCB, MCCB & RCCB for Phase-I&II, Stage-I, CTPP, Chhabra
Sl. No. Item Description
1MCB suitable for DIN rail type3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
2MCB Suitable for DIN rail type 3 pole, 415VAC, breaking capacity 10kA, C-Curve
3MCB suitable for DIN rail type4 Pole, 415VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
4MCB suitable for DIN rail type2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
5MCCB, Three Pole, Thermal magnetic trip, Ue=415VAC,50 hz,Icu=25kA,Ui=750V,Uimp=8kV,Ics=100% Icu, adjustable overload and adjustable short circuit setting
6MCCB, Four Pole, Thermal magnetic trip, Ue=415VAC,50 hz,Icu=25kA,Ui=750V,Uimp=8kV,Ics=100% Icu, adjustable overload and adjustable short circuit setting
7MCB suitable for DIN rail type4 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
8MCB suitable for DIN rail type1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
9MCB-DC suitable for DIN rail type2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
10RCCB suitable for DIN rail type 2 Pole, Un = 240 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008
11RCCB suitable for DIN rail type 4 Pole, Un = 415 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008
12MCB, Rated voltage:-230VAC housing type:-clip on DIN Rail Characteristics C-Type degree of protection IP20 breaking capacity 10KA
13Current rating:-1amp No.of pole:-1P
14Current rating:-2amp No.of pole:-1P
15Current rating:-3amp No.of pole:-1P
16Current rating:-4amp No.of pole:-1P
17Current rating:-6amp No.of pole:-1P
18Current rating:-10amp No.of pole:-1P
19Current rating:-16amp No.of pole:-1P
20Current rating:-32amp No.of pole:-1P
21Current rating:-2amp No.of pole:-2P
22Current rating:-4amp No.of pole:-2P
23Current rating:-6amp No.of pole:-2P
24Current rating:-10amp No.of pole:-2P
25Current rating:-16amp No.of pole:-2P
26Current rating:-20amp No.of pole:-2P
27Current rating:-32amp No.of pole:-2P
28Current rating:-40amp No.of pole:-2P
29MCB,Rated voltage:-220VDC housing type:-clip on DIN Rail Characteristics C-Type degree of protection IP20 breaking capacity 10KA
30Current rating:-2amp No.of pole:-1P
31Current rating:-4amp No.of pole:-1P
32Current rating:-6amp No.of pole:-1P
33Current rating:-2amp No.of pole:-2P
34Current rating:-4amp No.of pole:-2P
35Current rating:-6amp No.of pole:-2P
36Current rating:-10amp No.of pole:-2P
37Current rating:-16amp No.of pole:-2P
386A MCB with Auxiliary contact 1No+1NC, Rated voltage:-220VDC housing type:-clip on DIN Rail Characteristics C-Type degree of protection IP20 breaking capacity 10KA Current rating :-6amp no.of pole:- 2P Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57039737
AUTHORITY Government Departments
TENDER VALUE 8.10 Lakhs
LAST DATE 01-09-2026
Authority
Authority Name Rajasthan Rajya Vidyut Utpadan Nigam Limited
Work Description Tender for Supply Of Mcb, Mccb & Rccb For Phase-I&Ii, Stage-I, Ctpp, Chhabra , Mcb Suitable For Din Rail Type 3 Pole, 415Vac, Breaking Capacity= 10 Ka, B Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 10000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type 3 Pole, 415Vac, Breaking Capacity 10Ka, C-Curve , Mcb Suitable For Din Rail Type 4 Pole, 415Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type2 Pole, 240 Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (5-10)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mccb, Three Pole, Thermal Magnetic Trip, Ue=415Vac,50 Hz,Icu=25Ka,Ui=750V,Uimp=8Kv,Ics=100% Icu, Adjustable Overload And Adjustable Short Circuit Setting , Mccb, Four Pole, Thermal Magnetic Trip, Ue=415Vac,50 Hz,Icu=25Ka,Ui=750V,Uimp=8Kv,Ics=100% Icu, Adjustable Overload And Adjustable Short Circuit Setting , Mcb Suitable For Din Rail Type4 Pole, 415Vac, Breaking Capacity= 10 Ka, B Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type1 Pole, 240 Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (5-10)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb-Dc Suitable For Din Rail Type 2 Pole, 220 Vdc, Breaking Capacity= 10 Ka, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-2-2003 , Rccb Suitable For Din Rail Type 2 Pole, Un = 240 Vac, 50 Hz, Ip40, Residual Operating Current Iδn = 30 Ma, Instantaneous Tripping Time At Iδn 40 Ms, Im = Iδm 500 A, Inc = Iδc ≥ 6 Ka, Insulation Voltage 660 Vdc, Type A, Power Supply = Top/Bottom, Terminal Capacity Min/Max = 1.5/25 Mm², With Test Button, Confirming To Is 12640-1:2008 , Rccb Suitable For Din Rail Type 4 Pole, Un = 415 Vac, 50 Hz, Ip40, Residual Operating Current Iδn = 30 Ma, Instantaneous Tripping Time At Iδn 40 Ms, Im = Iδm 500 A, Inc = Iδc ≥ 6 Ka, Insulation Voltage 660 Vdc, Type A, Power Supply = Top/Bottom, Terminal Capacity Min/Max = 1.5/25 Mm², With Test Button, Confirming To Is 12640-1:2008 , Mcb, Rated Voltage:-230Vac Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka , Current Rating:-1Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-1P , Current Rating:-3Amp No.Of Pole:-1P , Current Rating:-4Amp No.Of Pole:-1P , Current Rating:-6Amp No.Of Pole:-1P , Current Rating:-10Amp No.Of Pole:-1P , Current Rating:-16Amp No.Of Pole:-1P , Current Rating:-32Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-2P , Current Rating:-4Amp No.Of Pole:-2P , Current Rating:-6Amp No.Of Pole:-2P , Current Rating:-10Amp No.Of Pole:-2P , Current Rating:-16Amp No.Of Pole:-2P , Current Rating:-20Amp No.Of Pole:-2P , Current Rating:-32Amp No.Of Pole:-2P , Current Rating:-40Amp No.Of Pole:-2P , Mcb, Rated Voltage:-220Vdc Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka , Current Rating:-2Amp No.Of Pole:-1P , Current Rating:-4Amp No.Of Pole:-1P , Current Rating:-6Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-2P , Current Rating:-4Amp No.Of Pole:-2P , Current Rating:-6Amp No.Of Pole:-2P , Current Rating:-10Amp No.Of Pole:-2P , Current Rating:-16Amp No.Of Pole:-2P , 6A Mcb With Auxiliary Contact 1No+1Nc, Rated Voltage:-220Vdc Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka Current Rating :-6Amp No.Of Pole:- 2P
Basic Detail
Tender No NIB-1400/2026-27
Bidding Type Tender
Location
City Baran
State Rajasthan
Key Dates
Publish Date 17 Aug 2026
Submission Date 01 Sep 2026
Open Date 02 Sep 2026
Finance
Tender Value 8.10 Lakhs
Tender Fee 236
EMD 16200
Exemption Available
Document List
5dccd6d9-df78-46bf-8b93-35eceb6ad499.html
BID1400.pdf
BOQ_1033679.xls
Tendernotice_1 (46).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

5dccd6d9-df78-46bf-8b93-35eceb6ad499.html

pdf

BID1400.pdf

xls

BOQ_1033679.xls

pdf

Tendernotice_1 (46).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders