Tender For Supply Of Mcb, Mccb & Rccb For Phase-I&Ii, Stage-I, Ctpp, Chhabra
Tender Overview
Project Description
Tender for Supply Of Mcb, Mccb & Rccb For Phase-I&Ii, Stage-I, Ctpp, Chhabra , Mcb Suitable For Din Rail Type 3 Pole, 415Vac, Breaking Capacity= 10 Ka, B Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 10000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type 3 Pole, 415Vac, Breaking Capacity 10Ka, C-Curve , Mcb Suitable For Din Rail Type 4 Pole, 415Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type2 Pole, 240 Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (5-10)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mccb, Three Pole, Thermal Magnetic Trip, Ue=415Vac,50 Hz,Icu=25Ka,Ui=750V,Uimp=8Kv,Ics=100% Icu, Adjustable Overload And Adjustable Short Circuit Setting , Mccb, Four Pole, Thermal Magnetic Trip, Ue=415Vac,50 Hz,Icu=25Ka,Ui=750V,Uimp=8Kv,Ics=100% Icu, Adjustable Overload And Adjustable Short Circuit Setting , Mcb Suitable For Din Rail Type4 Pole, 415Vac, Breaking Capacity= 10 Ka, B Curve, Ui ≥ 660 V, Magnetic Release Setting = (3-5)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb Suitable For Din Rail Type1 Pole, 240 Vac, Breaking Capacity= 10 Ka, C Curve, Ui ≥ 660 V, Magnetic Release Setting = (5-10)In, Uimp = 4 Kv, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-1-2002 , Mcb-Dc Suitable For Din Rail Type 2 Pole, 220 Vdc, Breaking Capacity= 10 Ka, Electrical/Mechanical Life 30000 Operations, Ip20, Confirming To Is/Iec60898-2-2003 , Rccb Suitable For Din Rail Type 2 Pole, Un = 240 Vac, 50 Hz, Ip40, Residual Operating Current Iδn = 30 Ma, Instantaneous Tripping Time At Iδn 40 Ms, Im = Iδm 500 A, Inc = Iδc ≥ 6 Ka, Insulation Voltage 660 Vdc, Type A, Power Supply = Top/Bottom, Terminal Capacity Min/Max = 1.5/25 Mm², With Test Button, Confirming To Is 12640-1:2008 , Rccb Suitable For Din Rail Type 4 Pole, Un = 415 Vac, 50 Hz, Ip40, Residual Operating Current Iδn = 30 Ma, Instantaneous Tripping Time At Iδn 40 Ms, Im = Iδm 500 A, Inc = Iδc ≥ 6 Ka, Insulation Voltage 660 Vdc, Type A, Power Supply = Top/Bottom, Terminal Capacity Min/Max = 1.5/25 Mm², With Test Button, Confirming To Is 12640-1:2008 , Mcb, Rated Voltage:-230Vac Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka , Current Rating:-1Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-1P , Current Rating:-3Amp No.Of Pole:-1P , Current Rating:-4Amp No.Of Pole:-1P , Current Rating:-6Amp No.Of Pole:-1P , Current Rating:-10Amp No.Of Pole:-1P , Current Rating:-16Amp No.Of Pole:-1P , Current Rating:-32Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-2P , Current Rating:-4Amp No.Of Pole:-2P , Current Rating:-6Amp No.Of Pole:-2P , Current Rating:-10Amp No.Of Pole:-2P , Current Rating:-16Amp No.Of Pole:-2P , Current Rating:-20Amp No.Of Pole:-2P , Current Rating:-32Amp No.Of Pole:-2P , Current Rating:-40Amp No.Of Pole:-2P , Mcb, Rated Voltage:-220Vdc Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka , Current Rating:-2Amp No.Of Pole:-1P , Current Rating:-4Amp No.Of Pole:-1P , Current Rating:-6Amp No.Of Pole:-1P , Current Rating:-2Amp No.Of Pole:-2P , Current Rating:-4Amp No.Of Pole:-2P , Current Rating:-6Amp No.Of Pole:-2P , Current Rating:-10Amp No.Of Pole:-2P , Current Rating:-16Amp No.Of Pole:-2P , 6A Mcb With Auxiliary Contact 1No+1Nc, Rated Voltage:-220Vdc Housing Type:-Clip On Din Rail Characteristics C-Type Degree Of Protection Ip20 Breaking Capacity 10Ka Current Rating :-6Amp No.Of Pole:- 2P
BOQ
| Sl. No. | Item Description |
| 1 | MCB suitable for DIN rail type3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002 |
| 2 | MCB Suitable for DIN rail type 3 pole, 415VAC, breaking capacity 10kA, C-Curve |
| 3 | MCB suitable for DIN rail type4 Pole, 415VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002 |
| 4 | MCB suitable for DIN rail type2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002 |
| 5 | MCCB, Three Pole, Thermal magnetic trip, Ue=415VAC,50 hz,Icu=25kA,Ui=750V,Uimp=8kV,Ics=100% Icu, adjustable overload and adjustable short circuit setting |
| 6 | MCCB, Four Pole, Thermal magnetic trip, Ue=415VAC,50 hz,Icu=25kA,Ui=750V,Uimp=8kV,Ics=100% Icu, adjustable overload and adjustable short circuit setting |
| 7 | MCB suitable for DIN rail type4 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002 |
| 8 | MCB suitable for DIN rail type1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002 |
| 9 | MCB-DC suitable for DIN rail type2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003 |
| 10 | RCCB suitable for DIN rail type 2 Pole, Un = 240 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008 |
| 11 | RCCB suitable for DIN rail type 4 Pole, Un = 415 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008 |
| 12 | MCB, Rated voltage:-230VAC housing type:-clip on DIN Rail Characteristics C-Type degree of protection IP20 breaking capacity 10KA |
| 13 | Current rating:-1amp No.of pole:-1P |
| 14 | Current rating:-2amp No.of pole:-1P |
| 15 | Current rating:-3amp No.of pole:-1P |
| 16 | Current rating:-4amp No.of pole:-1P |
| 17 | Current rating:-6amp No.of pole:-1P |
| 18 | Current rating:-10amp No.of pole:-1P |
| 19 | Current rating:-16amp No.of pole:-1P |
| 20 | Current rating:-32amp No.of pole:-1P |
| 21 | Current rating:-2amp No.of pole:-2P |
| 22 | Current rating:-4amp No.of pole:-2P |
| 23 | Current rating:-6amp No.of pole:-2P |
| 24 | Current rating:-10amp No.of pole:-2P |
| 25 | Current rating:-16amp No.of pole:-2P |
| 26 | Current rating:-20amp No.of pole:-2P |
| 27 | Current rating:-32amp No.of pole:-2P |
| 28 | Current rating:-40amp No.of pole:-2P |
| 29 | MCB,Rated voltage:-220VDC housing type:-clip on DIN Rail Characteristics C-Type degree of protection IP20 breaking capacity 10KA |
| 30 | Current rating:-2amp No.of pole:-1P |
| 31 | Current rating:-4amp No.of pole:-1P |
| 32 | Current rating:-6amp No.of pole:-1P |
| 33 | Current rating:-2amp No.of pole:-2P |
| 34 | Current rating:-4amp No.of pole:-2P |
| 35 | Current rating:-6amp No.of pole:-2P |
| 36 | Current rating:-10amp No.of pole:-2P |
| 37 | Current rating:-16amp No.of pole:-2P |
| 38 | 6A MCB with Auxiliary contact 1No+1NC, Rated voltage:-220VDC housing type:-clip on DIN Rail Characteristics C-Type degree of protection IP20 breaking capacity 10KA Current rating :-6amp no.of pole:- 2P Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender