Public Administrative Department Local Bodies Closing in 18 days TDR #57039372

Tender For Agency Empanelment For Electrical Installation, Repair And Maintenance Works For Dewas Municipal Corporation In Dewas

Issued by Local Bodies · Dewas, Madhya Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Sep 2026
18 days left
EMD
90000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dewas → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Agency Empanelment For Electrical Installation, Repair And Maintenance Works For Dewas Municipal Corporation In Dewas

BOQ

Name of Work:- Agency empanelment for electrical installation, repair and maintenance works for Dewas Municipal Corporation in Dewas
Sl. No. Item Description
1Description
2Laying of underground cable armoured/ unarmored as per specification in air with approved type of iron clamps complete. 2/3/4 core cable upto 16 Sq.mm
3Laying of underground cable armoured/uunarmoured as per specification in air with approved type of iron clamps complete. 2/3/4 core cable 25 Sq.mm to 120 Sq.mm
4Laying of underground cable armored/unarmored as per specification in air with approved type of iron clamps complete. 2/3/4 core cable upto 150 sq mm to 400 Sq.mm
5Dismantling of H beam pole with pipe, clamp, insulator, stay set, cement concrete, foundation, and making the site clear by refilling the pit to ground level and transporting to area store or any location as required in city
6Dismantling of PCC pole with pipe, clamp, insulator, stay set, cement concrete, foundation, and making the site clear by refilling the pit to ground level and transporting to area store or any location as required in city
7Dismantling of R.S joist pole with pipe, clamp, insulator, stay set, cement concrete, foundation, and making the site clear by refilling the pit to ground level and transporting to area store or any location as required in city
8Dismantling of tubular pole with pipe, clamp, insulator, stay set, cement concrete, foundation, and making the site clear by refilling the pit to ground leveland transporting to area store or any location as required in city
9Installation of H beam pole of required height with required concreting and inclusive of transportation from store/location of existing pole to the site/location to be installed.
10Installation of PCC pole of required height with required concreting and inclusive of transportation from store/location of existing pole to the site/location to be installed.
11Installation of R.S. joist pole of required height with required concreting and inclusive of transportation from store/location of existing pole to the site/location to be installed.
12Installation of Tubular pole of required height with required concreting and inclusive of transportation from store/location of existing pole to the site/location to be installed.
13Arm/angle/channel baseplate welding on pole inclusive of all required material
14Arm/angle/channel baseplate Nut bolt
15Supply and erection of ring or required shape for mini mast for required no. of flood light
16Supply and installation of tubular pole in meter
17Supply and installation of octagonal pole in meter
18Supply and installation of MS arm in meter of pole for street light
19Supply and installation of GI arm in meter of pole for street light
20M20 foundation of tubular/octagonal pole with required Nut bolt and required material according IS standard
21Erection of pole direct in a ground and muffing with required material, RCC/PCC/Tubular/R.S. joist/ H Beam
22Earthing of G.I. Plate with charcoal etc complete
23earthing of copper plate with charcoal etc complete
24chemical earthing complete
25supply and laying of G.I. Wire conductor earth electrod 4.0 mm (8.S.W.G.) dia G.I. Wire complete
26supply and laying of G.I. Strip 25x6 mm
27Supply and Laying rigid PVC single socket end, non-metallic pipe ISI Marked (IS-4985-2000) class 5 for protection of underground cable/or for water pump delivery side, for water supply complete with necessary clamp coupler,band, tee, Elbow etc. in an approved manner excluding cost of excavation etc laying of Required size pipe of 50 mm.
28Supply and Laying rigid PVC single socket end, non-metallic pipe ISI Marked (IS-4985-2000) class 5 for protection of underground cable/or for water pump delivery side, for water supply complete with necessary clamp coupler,band, tee, Elbow etc. in an approved manner excluding cost of excavation etc laying of Required size pipe of 25 mm.
29Supplying and laying GI Pipe 50 mm.
30Supplying and laying GI Pipe 25 mm.
31Supply and painting of pole/Arm Iron oxide paint color with labor
32Supply and painting of pole/Arm Al oxide paint colour with labour
33Other paint colour as required with color (yellow, Black, Blue etc.)
34Any wattage of LED flood light installation charges with required ladder or hydra
35Any wattage of LED Street light charges with required ladder or hydra
36short point wiring on surface including wire and other material
37Medium point wiring on surface including wire and other material
38Long point wiring surface including wire and other material
39short point wiring in existing conduit including wire and other material
40Medium point wiring in existing conduit including wire and other material
41Long point wiring in existing conduit including wire and other material
42power wiring on surface with 2 x 4 sq.mm cable and casing & caping including required material
43power wiring on surface with 2 x 6 sq.mm cable and casing & caping including required material
44power wiring on surface with 2 x 8 sq.mm cable and casing & caping including required material
45power wiring on surface with 3 x 4 sq.mm cable and casing & caping including required material
46power wiring on surface3 x 6 sq.mm cable and casing & caping including required material
47power wiring on surface with 3 x 8 sq.mm cable and casing & caping including required material
48power wiring 2 x 4 sq.mm in conduit including required material
49power wiring 2 x 6 sq.mm in conduit including required material
50power wiring 2 x 8 sq.mm in conduit including required material
51power wiring 3 x 4 sq.mm in conduit including required material
52power wiring 3 x 6 sq.mm in conduit including required material
53power wiring 3 x 8 sq.mm in conduit including required material
54Circuit wiring with 2 x 2.5 sq mm on surface including required material
55Circuit wiring 2 x 1.5 sq mm on surface including required material
56Circuit wiring 2x 1.00 sq mm on surface including required material
57Circuit wiring 3 x 2.5 sq mm on surface including required material
58Circuit wiring 3x 1.5 sq mm on surface including required material
59Circuit wiring 3 x 1.00 sq mm on surface including required material
60Circuit wiring 2 x 2.5 sq mm in conduit including required material
61Circuit wiring 2 x 1.5 sq mm in conduit including required material
62Circuit wiring 2x 1.00 sq mm in conduit including required material
63Circuit wiring 3 x 2.5 sq mm in conduit including required material
64Circuit wiring 3x 1.5 sq mm in conduit including required material
65Circuit wiring 3 x 1.00 sq mm in conduit including required material
66Main switch repairing including material (63A/100A/200A)
67LED street light Repairing with all accessories except Driver (Driver shall be provided by DMC)
68LED street light Repairing with all accessories except PCB (PCB shall be provided by DMC_
69LED street light Repairing with all accessories except Driver, PCB (Driver, PCB shall be provided by DMC)
70LED street Light Repairing including Glass, PCB, Driver and other required material 30 w
71LED street Light Repairing including Glass, PCB, Driver and other required material 48 w
72LED street Light Repairing including Glass, PCB, Driver and other required material 60 w
73LED street Light Repairing including Glass, PCB, Driver and other required material 90 w
74LED street Light Repairing including Glass, PCB, Driver and other required material 120 w
75LED street Light Repairing including Glass, PCB, Driver and other material required 150 w
76LED street Light Repairing including Glass, PCB, Driver and other required material 200 w
77LED Flood Light Repairing including Glass, PCB, Driver and other required material 30 w
78LED Flood Light Repairing including Glass, PCB, Driver and other required material 48 w
79LED Flood Light Repairing including Glass, PCB, Driver and other required material 60 w
80LED Flood Light Repairing including Glass, PCB, Driver and other required material 90 w
81LED Flood Light Repairing including Glass, PCB, Driver and other required material 120 w
82LED Flood Light Repairing including Glass, PCB, Driver and other required material 150 w
83LED Flood Light Repairing including Glass, PCB, Driver and other required material 200 w
84LED Flood Light Repairing including Glass, PCB, Driver and other required material 250 w
85Supply and Installation of Three pin top of 16 Amp.
86Supply and Installation of Three pin top of 6 Amp.
87Supply and Installation of modular switch of 16 Amp.
88Supply and Installation of modular switch of 6 Amp.
89Supply and Installation of modular socket of 16 Amp.
90Supply and Installation of modular socket of 6 Amp.
91Supply and Installation MCB Box 4 way (4+12) including required material
92supply and Installation MCB Box 4 way (8+12) including required material
93supply and Installation MCB Box 6 way (8+18) including required material
94supply and Installation MCB Box 8 way (8+24) including required material
95supply and Installation MCB Box 12 way (8+36) including required material
96supply and Installation Same board switch and socket - 6 Amp. including required material
97supply and Installation Same board switch and socket - 16 Amp. including required material
98Supply and Installation of Modular Box/plate 2 module with required size and shape with switch and socket required
99Supply and Installation of Modular Box/plate 4 module with required size and shape with switch and socket required
100Supply and Installation of Modular Box/plate 6 module with required size and shape with switch and socket required
101Supply and Installation of Modular Box/plate 8 module with required size and shape with switch and socket required
102Supply and Installation of Modular Box/plate 10 module with required size and shape with switch and socket required
103Supply and Installation of Modular Box/plate 12 module with required size and shape with switch and socket required
104Supply and Installation of Modular Box/plate 18 module with required size and shape with switch and socket required
105Supply and Installation of Modular Box/plate 24 module with required size and shape with switch and socket required
106D.G. Set Repair / Servicing/ Replacement of Item List
107D.G. Set servicing and visiting Charge 125 KVA
108D.G. Set servicing and visiting Charge 15 KVA
109Kirloskar care premium genuine oil 20 liters can
110Kirloskar care genuine coolant premix 5 liter can
111conversion kit from kg 934 to 645
112FIP calibration/repairs
113Alternator
114Engine coolant for water cool diesel engine
115Control panel AMF panel/manual control panel
116Radiator with fan
11724 vdc electric starter with battery
118Filters (Air, Fuel oil)
119RO Repair / Servicing/ Replacement of Item List
120Servicing and visiting charges of RO
121sediment Filters (PP Filter/spun filter)
122carbon filters
123membrane/UF membrane
124mineral cartridge/Alkaline cartridge
125TDS controller
126SMPS/adapter (24v, 36v)
127RO pump (Booster pump)
128low pressure switch (LPS), High pressure switch (HPS)
129Fitting and connectors (Elbow, tee, connector, reducer)
130Storage tank (if leak)
131Main switch repairing including material
132Control panel / Timer Repair / Servicing/ Replacement of Item List
133MCB/MCCB (Load protection)
134contactor (3 pole/ 4 pole) and relays required size
135overload relay (Thermal/Electronic)
136Digital/Analog Timer (dial and programmable both)
137push button, selector switch
138Indicator lamp (R/Y/G LEDS)
139control fuse/HRC fuse, cable Lugs
140Panel enclosure, mounting plate/Dinrail
141supply and installation of 32 amp. Cut out
142supply and installation of 63 amp. Cut out
143supply and installation of 100 amp. Cut out
144supply and installation of 200 amp. Cut out
145Supply and installation of MCB 6-to-32-amp singal pole
146Supply and installation of MCB 6-to-32-amp double pole
147Supply and installation of MCB 63 amp singal pole
148Supply and installation of MCB 63-amp double pole
149Supply and installation of MCB 63-amp triple pole
150Supply and installation of MCB 63 amp TPN
151Supply and installation of MCCB 100-amp TPN as IS Standard
152Supply and installation of MCCB 200-amp TPN as IS Standard
153Supply and installation of MCCB 400-amp TP as IS Standard
154Supply and installation of MCCB 630-amp TP as IS Standard
155Supply and installation of MCCB 800-amp TP as IS Standard
156Supply and Installation of 2 pole RCCB SPN
157Supply and Installation of RCCB 4 pole RCCB TPN
158Supply and Installation copper busbars of 32 amp. For single phase supply
159Supply and Installation copper busbars of 63 amp. For 3 phase supply
160Supply and Installation copper busbars of 100 amp. For 3phase supply
161Supply and Installation copper busbars of 200 amp. For 3phase supply
162Supply and Installation of Lugs up to 32 sq mm for cable.
163Supply and Installation of Lugs 35 sq mm for cable.
164Supply and Installation of Lugs 70 sq mm for cable.
165Supply and Installation of Lugs 150 sq mm for cable.
166Supply and Installation of Lugs 300 sq mm for cable.
167Speaker, Mixer, Audio amplifier Repair / Servicing/ Replacement of Item List
168Speaker cone/diaphragm
169Voice coil, cross over
170spider/suspension/ dust cop
171Magnet
172cabinet/Box/Wooder/fiber
173Channel favors (slider potentiometers
174Rotary knobs (Bass, mid, treble, gain control)
175Input (XLR, 6.35 mm jac, RCA), Output (main out, Aux Out, Montier Out)
176Internal power supply/adapter
177Display and PCB
178power transistors/misfits
179Pre amp Ics (TL072, NE5532), Power Ics (TDA, STK seris
180capacitor (Filter capacitor)
181Resistors and diodes
182Transformer (Step-down/Toroidal)
183SMPS power supply
184heat sink and cooling fan
185Input/output connectors (RCA, 6.35 mm) and volume/ton control pots)
186Fan Repair / Replacement of Item List
187Motor winding
188Capacitor 2.5 rF - 4 rF
189regulator
190Fan blades
191Height adjustment with required rod/pipe
192Repair of Exhaust fan 150 mm
193Repair of Exhaust fan 300 mm
194Repair of Exhaust fan 450 mm
195Air cooler Repair / Replacement of Item List
196cooler motor
197water pump
198capacitor (for motor )
199switches
200Regulator (Speed contool)
201wiring set, Indicator, light
202Fan Blade/Blower
203Swing motor
204water tank (if leak)
205body panels (plastic/metal body)
206castor wheels/stand and grass
207Water cooler Repair / Servicing/ Replacement of Item List
208cooling system - compressor
209condenser coil
210Eva poratar coil
211Refrigerant Gas (R22, R134, R290)
212Overload protector (OCP)
213SMPS/Power supply
214Fan Moter, water pump
215storage tank
216supplying and laying Copper Wire Bundle Heavy Duty L-90 Mtr. (300 Feet), 1 mm.
217supplying and laying Copper Wire Bundle Heavy Duty L-90 Mtr. (300 Feet), 1.5 mm.
218supplying and laying Copper Wire Bundle Heavy Duty L-90 Mtr. (300 Feet), 2.5 mm.
219supplying and laying 23/76 Wire Bundle Copper Heavy Duty L-90 Mtr-(300 Feet),.
220supplying and laying 6 sq. mm 2 core Copper Cable unarmored
221supplying and laying 4 sq. mm 2 core Copper Cable unarmored
222supplying and laying 2.5 sq. mm 2 core Copper Cable unarmored
223supplying and laying 1.5 sq. mm 2 core Copper Cable unarmored
224supplying and laying 1 sq. mm 2 core Copper Cable unarmored
225supplying and laying 6 sq. mm 3 core Copper Cable unarmored
226supplying and laying 4 sq. mm 3 core Copper Cable unarmored
227supplying and laying 2.5 sq. mm 3 core Copper Cable unarmored
228supplying and laying 1.5 sq. mm 3 core Copper Cable unarmoured
229supplying and laying 1 sq. mm 3 core Copper Cable unarmored
230supplying and laying 6 sq. mm 4 core flate copper Cable unarmored
231supplying and laying 4 sq. mm 4 core flate copper Cable unarmoured
232supplying and laying XLPE INSULATED 25 Sq.mm Cable 4 Core Aarmoured
233supplying and laying XLPE INSULATED 16 Sq.mm Cable 4 Core armoured
234supplying and laying XLPE INSULATED 16 Sq.mm Cable 2 Core Armouned.
235supplying and laying XLPE INSULATED 16 Sq.mm Cable 2 Core unarmored
236supplying and laying XLPE INSULATED 16 Sq.mm Cable Single Core Non-armoured
237supplying and laying XLPE INSULATED 10 Sq.mm Cable 4 Core armoured .
238supplying and laying XLPE INSULATED 10 Sq.mm Cable 2 Core armoured
239supplying and laying XLPE INSULATED 10 Sq.mm Cable 2 Core Un armoured
240supplying and laying XLPE INSULATED 10 Sq.mm Cable Single Core un armoured
241supplying and laying XLPE INSULATED 6 Sq.mm Cable 4 Core armoured
242supplying and laying XLPE INSULATED 6 Sq.mm Cable 4 Core un armoured
243supplying and laying XLPE INSULATED 6 Sq.mm Cable 2 Core armoured
244supplying and laying XLPE INSULATED 6 Sq.mm Cable 2 Core Un armoured
245supplying and laying XLPE INSULATED 6 Sq.mm Cable Single Core un armoured
246supplying and laying XLPE INSULATED 4 Sq.mm Cable 3 Core Non-armoured
247supplying and laying XLPE INSULATED 4 Sq.mm Cable 2 Core Non-armoured
248supplying and laying XLPE INSULATED 2.5 Sq.mm Cable 3 Core Non-armoured
249supplying and laying XLPE INSULATED 2.5 Sq.mm Cable 2 Core Non-armoured
250supplying and laying XLPE INSULATED 1.5 mm Cable 3 Core Non-armoured
251supplying and laying XLPE INSULATED 1.5 mm Cable 2 Core Non-armoured
252supplying and laying XLPE INSULATED 1 mm Cable 3 Core Non-armoured
253supplying and laying XLPE INSULATED 1 mm Cable 2 Core Non-armoured
254supplying XLPE INSULATED 35 sq. mm 4 core Copper Cable armoured
255supplying XLPE INSULATED 70 sq. mm 4 core Copper Cable armoured
256supplying XLPE INSULATED 150 sq. mm 4 core Copper Cable armoured
257supplying XLPE INSULATED 150 sq. mm 3.5 core Copper Cable armoured
258supplying XLPE INSULATED 300 sq. mm 4 core Copper Cable armoured
259supplying XLPE INSULATED 300 sq. mm 3.5 core Copper Cable armoured
260Supply and installation of Stay Wire and their accessories with complete set
261Fixing of Fluorescent Tube fitting on wall/ceiling on wooden round block with anchor fastener/Jook & necessary material including connection with 3 core flexible wire etc. complete as required.
262Dismantling of existing light/Fan/Bell/Socket out let point on separate board/Wiring with insulated wire in casing/conduit/Batten complete with fitting and accessories
263Making the site clear of the dismantling installation by refilling the hole with cement mortar & finished with paint gittie sand replacing to match the color of wall & ceilling.
264Dismantling o existing socket outlet point on same board in any system of wiring
265Dismantling the existing armored/unarmored cable or single core wires of submain,main,circuitinany system of wiring including recoiling.
266Dismantling of existing underground cable safely with its accessorie sand refilling the trench to ground level including recoiling of dismentalled cable.
267Dismantling of D.F. Boarded. Switch, T.P.&T.P.N.Switch or D.B.of any size complete with board or angle/flair on frame and making site clear including there filling hole & repainting to match colour of wall.
268Dismantling the existing Ceiling/exhaust/cabin fan with complete accessories and making the site clear.
269Dismantling of existing water tight fluorescent tube fitting/M.V. Lamp fitting with making the site clear.
270Providing recess in brick wall suitable for erection of exhaust fan up to 450 sweep complete with grouting of nut bolts, plastering and colour wash to match the colour of wall.
2711 For wall thickness up to 9\\"
2722 For wall thickness up to 15\\"
2733 For the stone wall thickness up to 15\\"
274Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long copper tube having single prongat top with 85 mm dia 3mm thick copper base plate including holes complete as required.
275Rivetting / Sweating and soldering of copper/G.I.Tape(with another copper/G.I.Tape,base of finialor any other metallic object ) as required.
276Providing and fixing copper tape 20mmX3mm thick on parapet and surface of wall of lightening conductor as required(for Horizontal runs )
277Providing and fixing copper tape 20mmX3mm thick on parapet and surface of wall of lightening conductor as required (forVertical runs )
278Supplying and drawing PVC insulated copper cable(Earth Continuity Conductor) of Green colour FR with copper multi strand conductor ISI marked in existing conduit along with other wires as required as per specification :
2794 Sq mm
2806 Sq mm.
28110 Sq mm.
28216 Sq mm
28325 Sq mm
284Labour rate for point wiring a Light/Fan/Twin control light/Socket outlet on separate board/Call bell Point in(open) surface rigid steel conduit system.
285Labour rate for point wiring a Light/Fan/Twin control light/Socketoutlet on separate board/Call bell Point in recessed/concealed rigid steel conduit system
286Labour rate for fixing rigid steel conduit insurface/concealed conduit wiring system, as per specification .
28720 mm Conduitmeter
28825 mm & 32 mm Conduit
28940 mm & 50 mm Conduit
290Labour rate for rewiring a Light/Fan/Twin control light/Socket outlet on separate board/Callbell Point in rigid steel/rigid PVC non metalic conduit in (open) surface conduit wiring system.
291Labour rate for rewiring a Light/Fan/Twin control light/Socket outlet on separate board/Call bell Point in rigid steel/rigid PVC non metalic conduit in recessed/concealed conduit wiring system.
292Labour rate for fixing rigid PVC conduit as per specification in recessed/concealed conduit wiring system.
29320 mm Conduit
29425 mm & 32 mm Conduit
295Labour rate for drawing cables in existing rigid steel conduit (surface or recessed/concealed )
2962.5 sq mm / 4 sq mm / 6 sq mm
29710 sq mm / 16 sq mm / 25 sq mm
298Supplying and fixing fan clamps of 16mm dia steel bar as per specification complete :-
299For stone slab roof \\"J\\" Type hook
300For R.C.C. Slabs / Beams
301For existing old R.C.C. Slabs / Beams
302Fixing of fan Regulator on existing switch board in position with necessary material connection etc.complete as required.
303Erection of exhaust fan/wall bracket fan/cabin fan in position with required PVC cable,rawl bolts etc.complete including connection sand making wall surface good.
304Supplying and fixing down rod of MS pipe for ceiling fan including threading, painting, making holes etc. as required complete
305Providing and fixing wooden board of suitable size(maxinum12\\"X18\\")for fixing of house service meter with necessary material sand connection testing etc. complete as per specification for Single phase meter or Three phase meter
306Providing & refilling of wood wool/Khaspads of normal size cooler panels 3 Nos including scraping of old paint,making surface even,painting with red oxide primer & two coats of paint of required shade including fixing new wiremesh complete.
307Servicing & overhauling of cooler fan motor,pump including replacemnt of distribution & delivary pipes,PVC elbows,painting etc.as reqd.complete with nacessary material & labour including replacement of connection leads
308Rewinding of fans by copper enamelled wire of suitable gauge including all required material,insulation,varnishing,connection leads,oiling.greasing etc complete with testing including dismentalling & refitting of fan at site.Scrap old material is not returnable to the department.
309Ceiling Fan 1400 mm sweep new model / Exhaust Fan 380 mm sweep
310Ceiling Fan 1200 mm sweep new model / Exhaust Fan 300 mm sweep
311Fresh Air Fan upto 300mm sweep/WallBracket/Cabin Fan 400mm sweep
312Cleaning, overhauling, servicing of ceiling/Exhaust/Wall bracket fan by applying grease & oil, including testing with mounting/Hanging arrangement including replacement of safty pins, check nuts ,locknut , nut bolts etc. making perfect allignment & refitting at site as required.
313Water proofing tape/ flex tape/ butyl tape roll (1.52 meter or above)
314Supplyinganderectionofwater tight terminalboxof14SWGM.S. Sheet 4mmthickboxof requiredsize 30x20x15 Cms.
315Cable jointing kit upto 25 sqmm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57039372
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 07-09-2026
Authority
Authority Name Municipal Corporation
Work Description Tender for Agency Empanelment For Electrical Installation, Repair And Maintenance Works For Dewas Municipal Corporation In Dewas
Basic Detail
Tender No 116/electric/2026 dewas date 14.08.2026
Bidding Type Tender
Location
City Dewas
State Madhya Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 07 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 90000
Exemption Available
Document List
BOQ_637652.xls
c025ed9e-7fcb-431d-92c4-0f845732cb57.html
document.pdf
itemlist.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_637652.xls

html

c025ed9e-7fcb-431d-92c4-0f845732cb57.html

pdf

document.pdf

pdf

itemlist.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders