Drinking Water Supply and Sanitation Local Bodies Closing in 8 days TDR #57038014

Tender For Providing High Wast Street Lights Arrangement At Maruthamalai Main Road, Mouthi Hospital Road Junction In Ward No.37, West Zone Roc No.1504/2026/Md2

Issued by Local Bodies · Coimbatore, Tamil Nadu
Tender Value
10 Lakhs
Estimated cost
Bid Submission
01 Sep 2026
8 days left
EMD
10000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing High Wast Street Lights Arrangement At Maruthamalai Main Road, Mouthi Hospital Road Junction In Ward No.37, West Zone Roc No.1504/2026/Md2

BOQ

Name of Work:- Providing High Wast Street Lights Arrangement at Maruthamalai Main Road, Mouthi Hospital road junction in ward no.37, West Zone ROC No.1504/2026/MD2
Sl. No. Item Description
1Supply and erection of Minimast (12 Metre) with 6 Nos. 150W LED Fitting with following specification.
2Supply and delivery of 12 Meter High Mast System fabricating with totally hot dip galvanized special steel plates suitable for 50 mtrs / sec wind velocity, fixing Head frame with canopy, movable lantern carriage. Three double drum winch, Hoisting ropes, double run of flexible multicore power tinned copper cable capable of 1.1KV grade. velocity of wind withstanding as specified in the relevant ISS and with Automatic switch ON and Switch OFF and arrangement should be made only 30% of lights glowing at mid-night of the Mast at a pre set time etc complete - 1 No
3Supply, delivery of 150W LED Flood Light Lumens minimum 100 / watt, input voltage: 90-270V AC, Power consumption: 150 w, power factor: not less than 0.9, optics: Toughened glass. 150 watts LED flood light an energy efficient luminary for all types of roads/highways integrated with IP 66 Standard. The fitting should having operating voltage of 240V, 50Hz at normal IS standard electrical connection. LM 79 and 80 Certified LED Chips are used to ensure high performance. Housing should be made up of Pressure die-cast Aluminium Metal core PCB, This breakthrough design in built to facilitate ultra-cool performance through 360° Deg natural air draught. The injection Moulded poly Carbonated UV Stabilized diffuser is optimized for more strength and optimum light transmission. Synergetic coupling of Pressure relief Membrane for moisture ingress Protection, Silicon potted driver with inbuilt protection. Powder coated housing through Nano technology compliments the system durability and reinforces the LED's life for 70,000 hours with lumen maintenance at LM 79 and 80. The Operating Temperature of Ambient Temperature: 10° C to + 70° C Celsius. Luminaries suitable for fixing Eco 120° Deg Mounting hole diameter: 50mm for pole arm etc complete. 6 Nos
4Supply of twin dome aviation obstruction lights of type BJAOL 2 with nos, incandescent lamps (1 fitting per mast is necessary if no taller structure are in near vicinity) 1 No
5Supply of control panel suitable control circuit for the operation of the mast. It shall also consist of suitable control for the power tool motor, up down contactor with Inter Lock mechanism, Dual electro mechanical timer pre settable 10 minutes per segment with 32 A 4 pole contactor 2 No's with Enclosure 1 No
6Design and casting of suitable shallow foundation with M15 RCC concrete for the high mast considering the safe soil bearing capacity at site as 10 T/sq.mtr. At 1.5 meter depth design as per standard. 1 No
7Erection and Commissioning of 16 Mtr high mast with the help of suitable equipment's 1 No
8Fixing Flood Light luminaries in the mast 6 No
9Supply and fixing of lightning arrestor at the top of the high mast with continuous G.I earth connection from the mast to ground 1 No
10G.I. Pipe earthing station as per the ISI specification with an earth electrode of 2.1mtr 'B' class Gl pipe of dia not less than 40mm, with copper earth plate of size 125mm X 50mm X 6mm with necessary funnelling arrangements with necessary masonry work and with 30mm RCC cover slab for the brick masonry. (2 per mast is mandatory, 1 for lighting and 1 for electrical) (PWD SD 233) 1 No
11Erection of Feeder Pillar with mass concreting mounting of the suitable ms frame as directed by the department officers 1 No
12Supply and fixing of Three phase service connection EB Meter box of size 15\\" x 14\\" x 9\\" with single compartment made up of 16SWG powder coated vermin proof metal sheet with clamps suitable for EB RCC pole suitable for three phase EB service connection. The meter box fixed with 12mm wooden board fixed with one number of 63 Amps porceline fuse unit Inter connection with 7/20 Amps PVC insulated copper wire with one number of neutral link. The meter box should be provided with glass in front side fixing of The meter box should be made PWD earthing. The rate includes dismanling of existing meter box and fixing new meter box, EB energy meter and accessories and termination of wires.
13EB Meter box of size 15\\"x14\\"x9\\" divided into two compartments made up of 16SWG powder coated vermin proof metal sheet with clamps suitable for EB RCC pole suitable for single phase EB service connection fixed with 12mm wooden board to fix EB meter. The meter box should be provided with glass in front side.
1463A, 500V Porcelain fuse unit
1515A , 4 way neutral link
16Inter connection with 7/16Amps PVC insulated copper wire.
17PVC Pipe-25mm
18PVC Bend-25mm
19PWD Earthing as per IS standard.
20Labour charges for fixing new meter box, EB energy meter and accessories and termination of wires.
21Supply and Laying of 4 x 16 Sq.mm PVC armoured LTUG Cable and 40 mm HDPE pipe in a trench to be excavated at a depth of 0.75 Metre putting 0.10 Metre. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
22Supply and Laying of 4 x 16 Sq.mm PVC LTUG Aluminium Armoured Cable in a trench to be excavated at a depth of 0.75 Metre putting 0.15 Metre Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
2340mm HDPE Pipe Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57038014
AUTHORITY Local Bodies
TENDER VALUE 10 Lakhs
LAST DATE 01-09-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Providing High Wast Street Lights Arrangement At Maruthamalai Main Road, Mouthi Hospital Road Junction In Ward No.37, West Zone Roc No.1504/2026/Md2
Basic Detail
Tender No E54/2026-WZ Single
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 17 Aug 2026
Submission Date 01 Sep 2026
Open Date 02 Sep 2026
Finance
Tender Value 10 Lakhs
Tender Fee Ref. Documents
EMD 10000
Exemption Not Available
Document List
971dba14-256a-4410-b8f6-662e5c7f6421.html
BOQ_835295.xls
ITB.pdf
SingleDocument.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

971dba14-256a-4410-b8f6-662e5c7f6421.html

xls

BOQ_835295.xls

pdf

ITB.pdf

pdf

SingleDocument.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders