Drinking Water Supply and Sanitation Local Bodies Closing in 7 days TDR #57037937

Tender For Repair And Maintenance Work At Lakk Alayam, Vinayagar Nagar, Periyapatty Ad Street, Bothupatty, Eb Colony, Mohanur Road, Sendamangalam Road And Lakshmi Nagar Anganwadi In Namakkal City Municipal Corporation.

Issued by Local Bodies · Namakkal, Tamil Nadu
Tender Value
19 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
7 days left
EMD
19000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Namakkal → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Work At Lakk Alayam, Vinayagar Nagar, Periyapatty Ad Street, Bothupatty, Eb Colony, Mohanur Road, Sendamangalam Road And Lakshmi Nagar Anganwadi In Namakkal City Municipal Corporation.

BOQ

Name of Work:- Repair and Maintenance work at Lakk alayam, Vinayagar nagar, Periyapatty AD street, Bothupatty, EB colony, Mohanur road, Sendamangalam road and Lakshmi nagar anganwadi in Namakkal City Municipal Corporation.
Sl. No. Item Description
1Earth work excavation for foundation in Hard stiff clay, stiff block cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete
2Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
3Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and Eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
4Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported by casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38
5Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
6Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using Fly Ash Bricks 230 x 110 x 70mm including finishing, curing, etc., complete complying with standard specification - 100CFT
7Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
8Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
9Painting two coats for Interior surface with approved Interior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
10Dadooing walls with ceramic tiles of sizes 300mm X 450mm X 8mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed.
11Paving the floor with pre-polished Concrete Anti-Skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg/sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.
12Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
13Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connectingmechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing allround the frames. The window should be got approved from the Executive Engineer before use on work
14Providing and fixing casement doors fabricated from unplasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
15Wiring with 2x1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5AFT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (5 points per coil) SD-18
16Wiring with 2x1.5sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with 150x100x113mm TW switch box for 5A 3pin non inter lockingWall socket with 5A flush types witch with painting of suitable colour with continuous earth wire connection of 1.5sq.mm copper wire for open PVC plug point SD-36
17Wiring with 2x4sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with 150mmx100mmx113mm TW switch box in flush with wall with 3mm thickhylem sheet cover for15A3 pin flush type non interlocking wall socket with 15A flush type switch with painting of suitable colour with continuous earth wire connection of 4sq.mm copper wire for open PVC power plug point SD-41
18Supply and fixing of single box type 4'36W fluorescent fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS Copper leads from terminals to the fitting SD-87
19Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb SD-83
20Supply and fixing of 1400mm sweep (56\\") AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod including fan clamp with side plates and cross arm of size 450mm SD-108
21supply and fixing of 25W LED street light fitting with LED (Lower end) with 19mm dia. GI pipe (class B) with 1 no.19mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . SD-446
22Flooring with Cuddapah slabs of 40mm thick over a base mortar in CM 1:3 (One Cement and Three Plastering Sand (P - Sand)) 20 mm thick and pointed with cement mortar 1:3 ( one cement and three Plastering sand) usimg Black oxide complying with standard specification (P & D data 53)
23Supplying and laying Rubberised interlocking Paver block M40 grade Providing and laying of 63mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, sand cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
24Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.
25Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57037937
AUTHORITY Local Bodies
TENDER VALUE 19 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Repair And Maintenance Work At Lakk Alayam, Vinayagar Nagar, Periyapatty Ad Street, Bothupatty, Eb Colony, Mohanur Road, Sendamangalam Road And Lakshmi Nagar Anganwadi In Namakkal City Municipal Corporation.
Basic Detail
Tender No 2088/2025/E1
Bidding Type Tender
Location
City Namakkal
State Tamil Nadu
Key Dates
Publish Date 15 Aug 2026
Submission Date 31 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 19 Lakhs
Tender Fee Ref. Documents
EMD 19000
Exemption Not Available
Document List
79e2da63-ec84-4e98-b88e-8e1b7d3e5db6.html
BOQ_835049.xls
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

79e2da63-ec84-4e98-b88e-8e1b7d3e5db6.html

xls

BOQ_835049.xls

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders