Tender For Special Repairing And Renovation Work For Development Of Electrical Infrastructure At Kardaha High School, Gangar Ur Assembly, In The District Of Dakshin Dinajpur.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2026
7 days left
EMD
70000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairing And Renovation Work For Development Of Electrical Infrastructure At Kardaha High School, Gangar Ur Assembly, In The District Of Dakshin Dinajpur.
BOQ
| Sl. No. | Item Description |
| 1 | PART A: Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required- 4 way (4 + 12), Double door. (Make Legrand/Schneider/Siemens) |
| 2 | Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required- 200 A, 16 KA,TPMCCB. (Make Legrand/Schneider/Siemens) |
| 3 | Providing and fixing following capacity TP&Ndisconnector fuse switch unit inside the existing panelboard with ISI marked HRC fuses including drillingholes in cubicle panel, making connections, etc. asrequired- (Make Legrand/Schneider/Siemens) i) 63 A TP&N |
| 4 | ii) 100 A TP&N |
| 5 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required- (Make Legrand/Schneider/Siemens) i) Triple pole and neutral |
| 6 | ii) Double pole |
| 7 | iii) Single pole |
| 8 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (Make Legrand/Schneider/Siemens) (But without MCB/RCCB/Isolator)- 4 way (4 + 12), Double door. |
| 9 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required- 8 way, Double door SPN MCBDB). |
| 10 | Supplying and making end termination with brasscompression gland and aluminium lugs for followingsize of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 KV grade asrequired. i) 4 X 10 sq. mm (25mm) |
| 11 | ii) 4 X 16 sq. mm (28mm) |
| 12 | ii) 2 X 10 sq. mm (19mm) |
| 13 | iii) 2 X 6 sq. mm (19mm) |
| 14 | Laying of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation,sand cushioning, protective covering and refilling thetrench etc as required: Upto 35 sq. mm |
| 15 | Laying and fixing of one number PVC insulated andPVC sheathed / XLPE power cable of 1.1 KV grade offollowing size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 16 | Providing and fixing following capacity TP&Ndisconnector fuse switch unit inside the existing panelboard with ISI marked HRC fuses including drillingholes in cubicle panel, making connections, etc. asrequired: 100A |
| 17 | Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch,connections etc. as required. |
| 18 | Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade,internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy>135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) -40 watt.( Make Halonix/Panasonic/Orient Electric) |
| 19 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 20 | Brush Less Direct Current (BLDC) Fan withRemote Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal(Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body.Power Factor not less than 0.9, Service Value(CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, remote (preferably mobile app based)for speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cableand earthing etc. as required- 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) (Make Havells/Orient Electric/Usha as per the choice of EIC) |
| 21 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 22 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable (Make Havells/Standard/Polycab) including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 23 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. |
| 24 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink ofaluminium housing such that LED junction temperature shall not rise above 90°C)- 100 watt (Make Halonix/Panasonic/Orient Electric as per the choice of EIC) Submission of test report and warranty certificate for atleast 3 years is mandatory from OEM. |
| 25 | Supplying, Installation, Testing & Commissioning of LED Recesse/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody including trim with Aluminium Reflector: 18 Watt |
| 26 | LED Panel light 2x2 ft. (System lumen efficacy ≥105<120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. system lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm): 40 watt (Make Havells/Halonix/Orient Electric/Panasonic as per the choice of EIC) |
| 27 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. |
| 28 | Providing and fixing earth bus of 50 mm X 5 mmcopper strip on surface for connections etc. asrequired. |
| 29 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required- 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 30 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 31 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 32 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 33 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 34 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 35 | Supplying and installaton following size of perforatedpainted with powder coating M.S. cable trays withperforation not more than 17.5%, in convenientsections, joined with connectors, suspended from theceiling with two numbers MS/GI Suspenders i/c baseof suitable size MS/GI angle, bolts & nuts, paintingsuspenders, fastener etc as required: 200 mm width X 50 mm depth X 1.6 mm thickness |
| 36 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable (Make Havells/Polycab/Standard approved by EIC) in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required: Group C |
| 37 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 38 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm), |
| 39 | 12 Module (200mmX150mm) |
| 40 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm size. |
| 41 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 42 | Supplying , Installation, Testing and Commissioning of AirCooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealedcopper Refrigerant piping with insulation (closed cellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU toODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase ACsupply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% ofthe rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressorand Printed Circuit Board (PCB). Must comply : Electricalcable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as perCPWD specification and IS : 1391 Part II 2023. The systemshall be able to operate up to 50 0C (out door ambienttemperature). Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating (Make Hitachi/Mitsubishi Electric/Daikin/Voltas/OGeneral) |
| 43 | Supplying, Installation, testing and commissioning includingvaccumiazation and Nitrogen testing of following nominalsizes of soft/hard drawn copper refrigerant piping forVRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazingincluding accessories, insulated with XPLE Class-O tubularinsulation/with Class-O closed cell elastometric nitrilerubber tubular sleeves sections of 19 mm thick insulationas given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required : i) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 44 | ii) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 45 | Supply, Installation, Testing and Commissioning of on-grid Solar Photo voltaic Power Plant conforming to MNRE specifications with only DCR compliance MNRE / SEC Tested ( Make Neosole / Waaree / Tata BP / Vikram Solar/ Adani /Panasonic/ Topsun/HR Solar/Novasys/Websol or equivalent)as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/ GI structure of suitable strength with following components complete as required : a)Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2.Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90 % at the end of 10year sand 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350- 800VDC Input voltage range and 400V AC, three phase, 4wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. Submission of test report and warranty certificate for atleast 5 years is mandatory from OEM. |
| 46 | Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 30 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%), Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, With Lithium- Iron Phosphate Battery (LiFePO4), charging time 8-10 hours, Battery backup time 12 hours (minimum), LED fixture watt 30 watt, Input voltage: 12V DC , Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI >70 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPER 15 A, lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K (As per American National Standard Institute (ANSI Bin)) , life time (LED,Driver & electrical circuitary) of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic swich on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 30 Watt (System lumen efficacy >150 lm/Watt)(Model No. BRP211LED45S Make Philips/Model No. : ENVIRO SEMI INTE SOLAR SL 30 W 30AH PIR Make Havells/ Model No :LEDSOLAR06SI30W30AHLIFEPO475WpWOPCWL Make Halonix/Model SUNSOKO BSSISL 30W LED D W Make Bajaj or equivalent model of Panasonic as per the choice of EIC) |
| 47 | Supply GI pipe as par IS/1239 ISI MARKED C Class(heavy) |
| 48 | Erection of RCC/ PCC pole of following length in brickballast and ramming the foundation, finishing with150mm thick cement concrete (1:3:6) layer on top withincluding excavation and refilling etc as required.Above 4.5 Meter and upto 6.5 Meter |
| 49 | PART B: Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand Havells/Polycab/Standard approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand Legrand Nextgen /Scheneider/ABB as approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board. |
| 50 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan ( Make Usha/Havells/Orient Electric as per the choice of EIC) and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (For Toilet)Submission of test report and warranty certificate for atleast 2 years is mandatory from OEM. |
| 51 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm Exhaust fan (12\\") |
| 52 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan ( Make Usha/Havells/Orient Electric as per the choice of EIC) and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. Submission of test report and warranty certificate for atleast 2 years is mandatory from OEM. |
| 53 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. |
| 54 | Supply of material and installation of MS hollow rectangular section confirming to IS 806-1968 & 1161-1998 connected to one another with bracket , gusset , cleat as per design, drawing and direction of Engineer - in - charge complete including cutting, to requisite shape & size , fabrication including metal arc welding using electrode of approved make, and complete in all respect, For roof truss work, span upto 12 meter length 80 mm x 40 mm x 3.2mm hollow rectangular bar for hanger of flood light on stage. |
| 55 | Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting. |
| 56 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 57 | Supplying and fixing 4 WAY MCB SS enclosure with IP-20/30 protection, powder coated including 2 NOS 6-32A two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. |
| 58 | Supply & Fixing 240 V, 25A Modular type socket, 25 A,Modular type starter (Brand approved by EIC) with 25AModular switch type DP MCB (C-Curve) and 6 Module GIModular type switch board with 6 Module top cover plateflushed in wall incl. S&F switch board and cover plate andmaking necy. connections with PVC Cu wire and earthcontinuity wire etc.(Make Legrand/Schneider Siemens) |
| 59 | S&F of Acrylic letter scripted in English/Bengali. size and matter of letter as per approved drawing by EIC, front side of the letter to be made 6mm thick imported (White- 0.40) uv stabilized excellent to self display. Make- Acast, Mitsubishi, all letter will be raised minimum 2\\" to be fixed by special type of solution. ( total sqm of Each letter is to be measused based on its front surface area) |
| 60 | S&F Water proof power supply system IP65, output volatge: 12V/24V DC, 50/60Hz frequency, 108 to 305 VAC power supply, >.95 power factor for LED lamp. (Make : Meanwell) 200 Watt, Model ELG 200 Submission of test report and warranty certificate for atleast 3 years is mandatory from OEM. |
| 61 | 26 Gauge Galvanized iron sheet for back panel with one coating of white paint, Make - Aarti / Bansal / Jindal |
| 62 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments): 4 core 10 sqmm |
| 63 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Air-Circulator adjustable Pedestal Fan (Make Usha/Orient Electric/Havells) and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 64 | Front Of the House (FOH) Speakers :Supply of Multidriver (at least 8 drivers) Active Column Array Speaker System with Frequency Range (-10 dB): 38 Hz to 20 KHz or better & built in Class D Amplifier of 1000 W or more. The loudspeaker should have a max SPL ≥ 127 dB & Horizontal dispersion angle ≥ 120º & Vertical dispersion angle ≤ 50º. There should be at least 8 Audio inputs & 2 outputs. There should be RJ45 connectivity option for connection between two units for two way communication. It should have a built in Digital Signal Processor & should be possible to stream & control wirelessly. (Approved Makes: Bose, Nexo, Electro-Voice) |
| 65 | Delay Fill Speakers : Supply of 8\\" Two-way Powered Speaker with one 1.25\\" or bigger HF compression driver with a Frequency Response(- 3dB):- 58Hz-19 KHz & In built Power amplifier of 1000 W or better. The Loudspeaker should have a Max. SPL of>125dB.The Sound Dispersion should be 90° x 60° orhigher. The speaker should have built in Digital Mixer withAutomatic Feedback suppression. It should have at leasttwo XLR/TRS inputs and should have built in PhantomPower.It should have polypropylene enclosure. It should have high quality Bluetooth stereo streaming facility & alsobluetooth control & monitoring using OEM Applicationthrough a mobile or tablet.(Approved Makes: Bose, Nexo,Electro-Voice) |
| 66 | Vocal Microphone :Supply of Corded Microphone with Dynamic NeodymiumMagnet microphone element,with frequency response50Hz-17kHz, Cardioid polar pattern,sensitivity ≥ 3.1mV/Paand output impedence 600 ohm (Approved Makes: AudioTechnica, Senheiser, Electro-Voice) |
| 67 | Installation :Installation, Testing & Commissioning of the entire Audiosystem, including supply of Cables, connectors & bracketsfor speakers |
| 68 | 75 Inch- AI lnteractive Flat Panel-Android14 Pearl White LED: Type D- LED Aspect Ratio:16:09 Resolution: 4K Ultra High Definition with 3840x2160 Brightness: 450 nits(Max),350- 400nits (Type) Touch: Optical Touch Technology with zero gap writing experience. CPU: 8 Core RAM : 8 GB ROM : 128 GB on board Wi-Fi : Dual Band 2.4 Ghz and 5Ghz (802.11a/b/g/n/ac)Speaker :40 Watts (20 Watts x 2 ) Power :75 inch(300W).( Make: Ekin) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer