Housing Urban and Rular Development Government Departments Closing in 3 days TDR #57034822

Tender For Upgradation And Beautification Of Narwara Road Junction On Dr. Aki Jan Road Eidgah Srinagar(Adv. Cost Rs 71.47 Lacs) (Incl Cost Of Material+Gst)

Issued by Government Departments · Srinagar, Jammu and Kashmir
Tender Value
71.47 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
3 days left
EMD
1.42 Lakhs
Bank guarantee accepted
Document Fee
1600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation And Beautification Of Narwara Road Junction On Dr. Aki Jan Road Eidgah Srinagar(Adv. Cost Rs 71.47 Lacs) (Incl Cost Of Material+Gst)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Aug-2026 Extension Notice Date 27-Aug-2026

BOQ

Name of Work:- Upgradation and Beautification of Narwara Road Junction on Dr. Aki Jan Road Eidgah Srinagar(Adv. Cost Rs 71.47 lacs) (incl Cost of material+GST)
Sl. No. Item Description
1Civil part
2Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil :
3Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material upto a lead of 1 kilometer, as per direction of Engineer-in-charge.
4Providing and laying stone soling hand packed including all carriages involved.
5Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:All kinds of soil : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
6Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
7Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
8Centering and shuttering including strutting, propping etc. and removal of form for:Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
11Providing and Laying Devri Stone 40 mm thick Tiles laid on 20mm thick cement mortar 1:4 mix including carriage complete job
12Providing and Laying Devri Cornice Stone on Foundation Bed Periphery with 300 mm width and height as per directions of EIC. As per approved design
13Providing and fixing of Ornamental Polished brass architectural finial and Tittle Signage 04 No;s \\"GATE NAME\\" in Urdu and English, featuring a decorative segmented or bulbous shaft, surmounted by a crescent moon emblem and Islamic customisation, for installation on a minaret or dome, size shape and made to be approved as per directions of EIC,20% Extra rate for Accent Backlighting as per directions of EIC.
14Tile brick masonry with common burnt clay non modular tile bricks of class designation 10 in plain arch work in superstructure above plinth level upto floor five level in cement mortar 1:4 (1cement :4 coarse sand) including curing, centering and shuttering complete.
15Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
1615mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand)
17Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
18Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
19Providing and fixing Acrylic Sheet 3 mm thick of approved make, colour and shade in partitions/signage, including cutting, edge finishing, polishing, and fixing with aluminium beading, stainless steel screws/adhesives, scaffolding, transportation, and complete as directed by the Engineer-in-Charge.
20Providing and fixing factory-made WPC (Wood Plastic Composite) Islamic Customised Calligraphic Jali of approved design, pattern, and shade, made from exterior-grade UV-stabilized WPC board of minimum density 650 kg/m³ and thickness 18 mm, suitable for outdoor use. The jali shall be CNC/laser-cut as per architectural drawing and fixed directly into the civil structure/frame using necessary brackets, anchor fasteners, stainless-steel screws, and washers, etc., complete as per direction of Engineer-in-Charge. The surface shall be finished with two coats of exterior-grade PU / weather-resistant paint over one coat of primer, including surface preparation, scaffolding, and all materials and labour complete
21Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for underground structures as directed by Engineer-in-Charge and consisting of : i) 1st layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with waterproofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone.
22Providing and fixing in position Glass Reinforced Concrete (GRC) decorative mouldings of approved make, in specified pattern, shade, and thickness. The moulding shall be straight, with projection of 300 mm and a height of 230 mm, fixed firmly to the structure with necessary required brackets viz. 08 No's of Arch Starter Brackets of design as per EIC and fasteners at required spacing. The work shall include the cost of all materials, labour, T&P (Tools & Plant), scaffolding required for all heights and levels, and finishing the joints with approved sealant. The work is to be completed in all respects as per the architectural drawings, specifications, and directions of the Engineer-in-Charge
23Providing and fixing Glass Reinforced Concrete (GRC) mouldings of approved design, size, and profile, factory cast with GRC mix (1 part cement: 1.5–2 parts silica sand reinforced with alkali resistant glass fibre @ 4–5% by weight of cement, water, and approved admixtures). The mouldings shall be manufactured in approved patterns, properly vibrated, cured, demoulded, and finished smooth on all exposed faces.Fixing shall be done with stainless steel / galvanized anchors, adhesive mortar, necessary scaffolding, and complete as per architectural drawings and the direction of Engineer-in-Charge.
24Foot Path
25Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:
26Dismantling steel work in single sections including dismembering and stacking within 50 meters lead in : Channels, angles, tees and flats
27Refixing of steel work in single section by way of welding /placing in original position as desired with straigting /cutting /and beding all complete
28Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil :
29Providing and laying stone soling hand packed including all carriages involved.
30Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:All kinds of soil : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
31CEMENT CONCRETE (CAST-IN-SITU)Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4
32Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
33Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge.
34Providing Retro-reflective regulatory sign board of size 900mm diameter made out of 2mm thick aluminum sheet, face to be fully covered with high intensity encapsulated lens type retro-reflective sheeting as approved by Engineer-in-charge. Letter, symbols, borders, etc. will be as per IRC:67 with required colour scheme on the boards and with the high intensity grade A. the aluminum sheet to be riveted to M.S. frame of angle iron of size 40x40x4mm. The boards will be fixed to 1 No. 50x50mm square post made of M.S. angle 50x50x4mm, 4m long welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminum sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per directions of Engineer-in-charge.
35Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
36Providing, laying and making kerb channel 30cm wide and 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth etc. complete as per direction of Engineer-incharge.
37Providing and fixing Glow studs of size 100x20mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (High impact Polystyrene) or ABS having electronically welded micro-prismatic lens with abrasion resistant coating as approved by Engineer-in-charge. The Glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro-reflective surface shall be 35 +/- 5 degrees to base. The reflective panels on both sides with at least 12cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as
38Providing and fixing post delineators made of ABS round body fitted with 2nos. 100mm dia high reflective and reflectors and mounted on M.S. pipe of 65mm dia duly powder coated with anti-rust and anti-theft steel to be installed as per direction of Engineer-in-charge.
39Providing and fixing of solar road marker (cat eye) with cast alluminium shank strong compresssive capacity solar panel ground lights stable LED lights for driving for road warning having dimension of 10.5 x 12.5 x8 cm with water proofness/of required colourand design to prevent dust and water for entering longer durability inclding neccessary required fixtures like bolt screws/aproxty if required appproved brand and manufacutre including all taxes invovled up to site complete job(FOR EACH ZEBRA) INCLUDING P/F OF M/S HOOKS TO LOCK THE THE SMART CITY TRAFFIC SIGNAL CABLES OF SIZE 75MMX50MMX4MM ( 600 NOS ) APPPROVED AS PER THE SITE INCHARGE AND AS PER REQUIREMENT
40P/fixing of stainless steel dust bin with( lid)cover including fixing it in c,conrete 1:1.5:3 mix including all carraige,taxes invlolved upto site complete
41p/filling of good earth inclduing breaking of clods spreading and sorting incluidng carriage
42Carriage of material forSand Avg leading upto 15km
43Aggregate Carriage lead upto 15 km
44Brick Avg lead upto 20 km
45Electric Part
46Wiring for Light point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper conductor singlecore cable (Polycab Green/Finolex/Salzer/Havells lifeguard Make) In surface/recessed Conduits lald in slabs / Celling (including cost of Condult) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover In front & suitable 1 box etc ISO/IEC Certified Antl-Bacterial Series of Legrand/L&T/Siemens/AB Make & shall be approved before execution of work.
47Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copperconductor, single core Cable in existing surface/Recessed medium class PVC condult (Polycab Green/ finolex /Salierj Havells lifeguard Make) & shall be approved Lefore exccution of work. Including termination and p/f of Copper thimbles of required slze and number on Input and out slde rolled with colour coded type and p/f of ferriols on I/p and ofp side for each dircuit. 236 sq.mm 1x6 sa.mm (P+N+E) for Lighting/inverter Sub maln In One run from Main Panel to Distribution Boards,
48225 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circult In One run from switch boards to Distribution Boards.
49Supply/Fixing/Testing and Commissloning of 6Amp to 32Amp Rating SP,240v,C* Curve 10K, Miniature Circult Breakersuitable for Inductive load of following poles In exlsting MC8 . DB Complete with connections. (L&T/ siemens/ Legrand/ ABB / Schnelder/BCH Make)
50Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole, {single phase and neutral), 240 V, residual current circuit breaker (RCCO), having a sensitivity current 30mA In the existing MCB DB complete with connections, testing and commissloning etc. as required. (L&T/Slemens /Legrand/ABB/Schneider/0CH Make) 25-32 Amp
51Supplylng and Fixing of MCB 8-Way horlzontal typed , sheet steel, Double Door Distribution Board, SPN 240V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, Interconnections, powderpainted including earthing etc, as required. (L&T/Slemens/Legrand/ ABB /Schncider/BCH Make)
52Sunply Laving of following PVC Conduits with allled accessories including cutting of walls /floors with hydraullcutters and refacing to original position by way of p/I of cement concrete /POP and painting wherever required and asper instructions of EIC (BCH/Polycab/Finolex/Astral Make. 25 mm Dia
5332 mm Dia
54Supply and fixing of 12-15 Watt LED(Warm Type) Powder coated Pressure die cast/Extruded aluminum Body Including trim with Aluminum Reflector (System lufnen efficacy ≥ 120 Im/Watt ) Recess/surface mounted as per site requirement) (Commercialtype) downlighter having following specficaications The luminaire should have a colour temperature of 6500°K, CRI≥280:and SDCM≤S. Luminaire shll be esigned to emit nitial system lumen output of greater than 2150 |umens The downlighter shall be back-it & not side-it, The driver shall have THDS10% (@ful Load) and PF 20.95 @full load). The lominaire housing /body should made of pressure die-cast luminum. The ixture should comply with the parameters as per 1510322. The luminaire shall have impact resistance 0f IK02 & Ingress protection of IP20.Luminaire manufacturer must have in-house NABL aceredited lab to conduct LM79, Type test as per 1510322, \\"FAT\\"before dispatch as per 15 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 1o 25 ¢ The successful bidder must submit the NABL accreditation certfcate for Luminaire manufacturer before< pply of materil. The LED Luminaire should be BI regitered: Successfulbidder shallsubrnit the following reportsperore supply of material for pprovals: L79 ssued by NABL occredited ab, LMD Isued by LED manufacturer, TypeTest Certificate for luminaire as Issued by NABL accredited lab & BIS certificate for LED Luminalre & Driver. The Agency i/ firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by . otficer from the department not below the rank of SDO prir to the supply of materlas. The Jab includes 2-years replacement warrenty from OEM for the entie ighting fstures from the the date of sucessful handing over of site tontending department , covering any damage /mulfunctioning /burnt out what so ever reason. \poroved Make: igaily (Philos)/Lighting Techonology/sndo/Regent /Triux /Wipro make.
55Suppiy imstalation/Testing and Commissioning of IP-66/68 Homogenous LED lrlp (Warm Type) Warm Tght/REDotout 3 per site requirement with following Specifications: Input Wattage: 08-10W / MtrInput Voltage: 220 20UAC it Frequency: 50 Hz, Input Current (Max: SOmA, Powier Factor:. > 0.95 Surge Protection:2 5KV, High Voltage Protection:300V,HI.POT:LSKY, P Rating:IP 65/68,Working Temperalure:-10°C t0 50°C, LED:Bridgelux, Lumen \sintenance :70% After 50000 BH,Rated CCT: 3000K, 4000K, GS00K Rated CRi:> BO,System < ficacy: 100m/W ,Housing:ilcon Pipe covers the LED Strip Lght of Phlips/Wioro/J sy e AR & shall be approved not less than by S0O.The Job includes S/L of Al profile
56Sapply/FIng/Testing and Commissioning of of Adoptor (CV DRIVER LED STRINGS 12V 2 A IP-66) of phillps /Wioro /loguar/Surya/ Equivalent Make & Shall be approved not less than by SDO.
57Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 230 volts DP MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:​1. Normal Incoming:125 Amp DP MCCB with suitable breaking capacity with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,100 Amp Bus bar Al Strips(P+N) = 1 Set,Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicator =1 No.2. Generator/Inverter Incomer:63 Amp Single Phase Automatic Change over Switch of Legrand/Siemens/ABB/Havells/LK make = 1 No.3. AVR Bypass Switch: 100Amp 4-Pole Bypass Switch​Outgoing:​(1) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 02 No for normal heating sub main​(2) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 02 No for Sub main lighting​(3) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 02 No for Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing.
58ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Nacessary soil treatment is to be made by the contractor in order to Improve the Pit resistance Value Supply,installation and Testing of 75 mm copper Pipe Filed with Crystaliine conductive Mixture with Eco friendly GEM Backfill Compound 2No, Bags also having Earth pit chamber (300mm x 300mm) with- man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylenc Pipe having Corrugation complete Job. (Main Panel)
59Supply, Installation, testing and commissioning of 20-30W LED RGBW floadlighting luminaire for facade lighting with die-cast aluminlam housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control, The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete-with driver andcapable of operating at line voltage without any separate power supply from 100-270V AC, 50 Hz with power factor >0.9, fisture shall be suitable to operate at an ambient temperature range of 10º C T + 50ºC and shall be 1P 65 and IK 06rated. Lifetime shall be aleast L70:50000 burning hours at 50ºC , Luminaire shall be conformming to BIS(IS 10322) andeshall be complete with all necessary accessories required for proper working of fixture Including weather proof connection cables, water proof connectors etc as required.Phillps / Wipro / Surya/ Regent / Endo /Helonix make
60Supply, Laying, Testing and Commissioning of 2-core 16 Sq.mm XLPE Insulated PVC Inner sheathed steel armoured Alcable of Havells make Incl making of necessary connections with proper size of Al Thimbles dully crimped with crimping tool in cable trench incl excavation and refilling back with execuated earth Including cost of suitable Size of it HDPE Pipe (Excluding sand cushion ) The Job Includes CMC for a period of three years reckoned from date of sucessfull commissioning , CMC includes timely servicing and replacement of damaged /burnt out cables by fresh one If needed what so ever reasons for ensuring smooth operation for a CMC Period Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57034822
AUTHORITY Government Departments
TENDER VALUE 71.47 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Upgradation And Beautification Of Narwara Road Junction On Dr. Aki Jan Road Eidgah Srinagar(Adv. Cost Rs 71.47 Lacs) (Incl Cost Of Material+Gst)
Basic Detail
Tender No 36 of RNB//Sgr-Core/2026-27
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 22 Aug 2026
Submission Date 27 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value 71.47 Lakhs
Tender Fee 1600
EMD 1.42 Lakhs
Exemption Not Available
Document List
6a2bd3e7-98a8-4f5c-a477-9ca815b01fd7.html
BOQ_1069352.xls
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

6a2bd3e7-98a8-4f5c-a477-9ca815b01fd7.html

xls

BOQ_1069352.xls

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender