BOQ
| Sl. No. | Item Description |
| 1 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 2 | 100 mm |
| 3 | 150 mm |
| 4 | 200 mm |
| 5 | 250 mm |
| 6 | 300 mm |
| 7 | 350 mm |
| 8 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. All kind of soil |
| 9 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: |
| 10 | Ordinary rock |
| 11 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 12 | Manually Operated CI Sluice Valve PN-1.0 (Sectional Valves and Scour Valve) |
| 13 | 80 mm HW |
| 14 | 100 mm HW |
| 15 | 125 mm HW |
| 16 | 150 mm HW |
| 17 | 200 mm HW |
| 18 | 250 mm HW |
| 19 | 300 mm HW |
| 20 | 350 mm HW |
| 21 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 22 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 Junction Valves |
| 23 | 100 mm |
| 24 | 150 mm |
| 25 | 200 mm |
| 26 | 250 mm dia |
| 27 | 300 mm dia |
| 28 | 350 mm |
| 29 | 400 mm dia |
| 30 | 450 mm dia |
| 31 | 500 mm dia |
| 32 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 |
| 33 | 100 mm dia |
| 34 | 150 mm dia |
| 35 | Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6 |
| 36 | 80 mm dia |
| 37 | 100 mm dia |
| 38 | 125 mm dia |
| 39 | 150 mm dia |
| 40 | 200 mm dia |
| 41 | 250 mm dia |
| 42 | 300 mm dia |
| 43 | 350 mm dia |
| 44 | 400 mm dia |
| 45 | 450 mm dia |
| 46 | 500 mm dia |
| 47 | Construction of RCC Valve Chamber of following size including required earth work (PCC M-10, 10 CM th. ) RCC vertical walls in M-20 grade cement concrete of suitable size as per GAD including providing fixing of Reinforced Ferro cement Drain cover designed for class \\"AA\\" loading complete as per specification and scope of work. ( Item based on RUIDP 2017) |
| 48 | Valve Chamber size 0.90X1.20 Valve size up to 150 mm |
| 49 | Valve Chamber size 1.50X1.20 Valve size up to 200 mm to 300 mm |
| 50 | Valve Chamber size 1.50X1.80 Valve size up to 350 mm to 450 mm |
| 51 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. ( Class PN 1.6) |
| 52 | 40 mm |
| 53 | 50 mm dia |
| 54 | 80 mm dia |
| 55 | AIR VALVE PILLAR - Construction of RCC Air valve pillar of following size including required earth work (PCC 1:4:8 )circular pillar of M-20 cement concrete of suitable size as per GAD including providing fixing of GI pipe with flang and required fitting for air valve complete as per specification and scope of work. ( Item based onRUIDP BSR 2017) |
| 56 | Air valve piller 25 mm |
| 57 | Air valve piller 40 mm |
| 58 | Air valve piller 50 mm |
| 59 | Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1- Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. All work up to plinth level : |
| 60 | 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size). |
| 61 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. |
| 62 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level. |
| 63 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 64 | Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 65 | Bituminous courses |
| 66 | Granular courses |
| 67 | Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. |
| 68 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work. |
| 69 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 70 | Repair of Bituminous Road using GSB 15 cm thick, WBM 15 cm thick in two layers , 20 mm thick bitumin carpet and sand seal coat Complete as per specification and scope of work. ( based on RUIDP BSR 2017) |
| 71 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 72 | Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - |
| 73 | a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
| 74 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 75 | Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 |
| 76 | 150 KL capacity At vinaun HW (1 No.) |
| 77 | 200 KL Capacity At jiroli PH |
| 78 | 300 KL capacity At Nabhera & Paharpur (2 Nos.) |
| 79 | Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - |
| 80 | a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. |
| 81 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 82 | Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE2,3 & 4 |
| 83 | 400 KL capacity at Dhokas CWR (1 No.) |
| 84 | Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3. |
| 85 | 900 KL capacity At Girdharpura PH (1 No.) |
| 86 | 1500 KL At Banhera Hw (1 No.) |
| 87 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 88 | Pipe for CWR |
| 89 | 100 mm |
| 90 | 150 mm |
| 91 | 200 mm |
| 92 | 250 mm |
| 93 | Construction of Pump House of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect. |
| 94 | Dhokas |
| 95 | Girdharpur |
| 96 | Bahnera |
| 97 | NABHERA |
| 98 | Paharpur |
| 99 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. |
| 100 | Dhokas |
| 101 | Girdharpur |
| 102 | Bahnera |
| 103 | NABHERA |
| 104 | Paharpur |
| 105 | Provsion for Construction of CC Road At HWs |
| 106 | Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints. (2X5X90) |
| 107 | Supply, installation and commissioning of Mono Rail Single Girder Crane suitable for lift up to 9m with chain 9m pulley block and traveling trolley excluding cost of girder complete in all respect as per the direction of the Engineer. |
| 108 | 2 MT Capacity |
| 109 | Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - -: - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type). |
| 110 | k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 111 | RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 18 M |
| 112 | 100 KL |
| 113 | 150 KL |
| 114 | 200 KL |
| 115 | 250 KL |
| 116 | RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 20 M |
| 117 | 100 KL |
| 118 | 150 KL |
| 119 | 200 KL |
| 120 | 250 KL |
| 121 | 300 KL |
| 122 | 400 KL |
| 123 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 124 | 80 MM |
| 125 | 100 MM |
| 126 | 125 MM |
| 127 | 150 MM |
| 128 | 200 MM |
| 129 | 250 MM |
| 130 | EFM 300 mm |
| 131 | EFM 400 mm |
| 132 | FLOW METER HUT - Construction of Room for Flow Meter ( Flow meter hut), work including require earth work, PCC 1:4:8 in foundation and under floor, stone masonary in 1:6 cement sand mortar for foundation up to plinth level ( 0.3 Mtr. above from Average GL), 23 cm th. Brick masonary for super structure in 1:6 cement sand mortar RCC roof of 125 mm th. in M-25 grade cement concrete, CC flooring, MS sheet door, sanctional window shuter, wire gauge for window, 20 mm thick cement plaster out side and in side, water proofing cement paint and synthetic enamel paint on door and window complete as per specification, scope of work and general arrangment Drawing. (Item Based on RUIDP 2017 BSR ) |
| 133 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. |
| 134 | Centrifugal Monoblock Pump set (Single Stage) |
| 135 | 2.2 KW (3.0 HP) at Dhokas |
| 136 | 3.7 KW (5.0 HP) at Dhanwara |
| 137 | 7.5 KW (10 HP) at Uchhain & Sikrori |
| 138 | 11.0 KW (15 HP) at Roopbas, Awar, Girdharpur, Gundwa, Mallah, Bahnera |
| 139 | 15.0 KW (20.0 HP) at Roopbas, Nabhera, Uchhain, Dhokas |
| 140 | 18.5 KW (25.0 HP) at Paharpur, Sikrori, Dhnawara, Mallah, Jiroli |
| 141 | Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 142 | PH RUPBASTo CWR Vinaun Q113.07 Head 61.84 KW 110 |
| 143 | PH RUPBASTO ESR GAHNOLI CWR MADARIYAPURA ROUTE Q126.53 Head 51.86 KW 110 |
| 144 | PH RUPBASTO ESR BHIRYANI MOROLI DAHIR ROUTE Q51.56 Head 67.53 KW 55 |
| 145 | PH RUPBASTO ESR RUNDH ROOPWAS,PURA ROUTE Q24.48 Head 87.89 KW 37 |
| 146 | CWR VINUAN TO ESR JATLA NAGMASI PAHARPUR PH Q49.93 Head 72.29 KW 55 |
| 147 | CWR VINUANTO ESR ESR MAHALPUR KACHHI NABERA PH Q52.29 Head 61.02 KW 55 |
| 148 | PH PAHARPURTO ESR MAHALPUR CHORA DUMRIYA ROUTE Q21.87 Head 50.7 KW 22 |
| 149 | PH-NABHERATO ESR KHERA THAKUR RUDWAL ROUTE Q29.1 Head 53.46 KW 30 |
| 150 | CWR MADARIYPURATO ESR MADARIYAPURA CWR UCHHAIN ROUTE Q53.33 Head 39.44 KW 45 |
| 151 | AWAR (P/H)TO ESR ABURA DIDWARI ROUTE Q23.24 Head 56.53 KW 30 |
| 152 | AWAR (P/H)TO ESR AJAN DHANWARA ROUTE Q25.23 Head 66.69 KW 37 |
| 153 | KUMHER (H/W)TO DHOKAS & AWAR PH Q69.26 Head 55.34 KW 75 |
| 154 | KUMHER (H/W)TO ESR JARHARA DANWARA PH Q49.02 Head 72.98 KW 75 |
| 155 | KUMHER (H/W)TO SIRKORI PH Q58.73 Head 29.71 KW 37 |
| 156 | KUMHER (H/W)TO ESR BALERA KALAN SHE ROUTE Q25.43 Head 48.67 KW 30 |
| 157 | GIRDHARPUR PHTO ESR BHANDOR NAGLA HARCHAND ROUTE Q27.92 Head 44.41 KW 30 |
| 158 | SIKRORI(P/H)TO ESR SIRKORI KURBARA ROUTE Q33.54 Head 59.35 KW 45 |
| 159 | Dhanwara (P/H)TO ESR PADOLA SIHI ROUTE Q18.53 Head 63.08 KW 22 |
| 160 | PH MahuaESR MahuaESR (P) DhaurESR SAHANAESR Chak Shahna (OTMP) Q24.29 Head 53.4 KW 30 |
| 161 | PH MahuaESR DHANOTA ESR (P) jharoliESR KhanswaraESR (P) Khanswara Q21.22 Head 70.5 KW 30 |
| 162 | Mallah Pump House to ESR Tatamar PH Mahua Route Q75.63 Head 68.36 KW 90 |
| 163 | Mallah Pump HousePH JIROLI & PH Bahnera Q162.21 Head 51.93 KW 150 |
| 164 | Mallah Pump House to ESR Unchagaon, ESR Sukhawali Q27.18 Head 67.88 KW 37 |
| 165 | Bahnera Pump House to ESR (OTMP), Bachhamandi Route Q27.93 Head 41.03 KW 22 |
| 166 | Bahnera Pump House to ESR (OTMP) Chak Hathkauli Q32.52 Head 59.84 KW 45 |
| 167 | CWR-JIROLITO ESR JAGEENA PEEPLA GHUSIYARI ROUTE Q36.34 Head 58.3 KW 45 |
| 168 | CWR-JIROLITO ESR BILUITHI SANTROOK ROUTE Q23.52 Head 76.98 KW 37 |
| 169 | CWR-JIROLITO ESR BARKHURE BAJHERA ROUTE Q32.39 Head 62.67 KW 45 |
| 170 | Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. |
| 171 | CWR MADARIYPURATO ESR PICHOONA SHERI KALAN ROUTE Q54.17 Head 106.42 KW 90 |
| 172 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \\"O \\"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 173 | Class PN 1.6, Motorised Operated |
| 174 | 200 mm dia |
| 175 | 250 mm dia |
| 176 | 300 mm dia |
| 177 | 350 mm dia |
| 178 | 400 MM |
| 179 | Providing, lowering, aligning, fixing in position in pipe line, DI double flanged resilient seated Dual plate check valave of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,Spring SS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) , Insersion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 180 | Class PN 1.6 |
| 181 | 100 mm dia |
| 182 | 150 mm dia |
| 183 | 200 mm dia |
| 184 | 250 mm dia |
| 185 | 300 mm dia |
| 186 | 350 mm dia |
| 187 | 400 mm dia |
| 188 | Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge. |
| 189 | 100 mm dia. |
| 190 | 150 mm dia. |
| 191 | 200 mm dia. |
| 192 | 250 mm dia. |
| 193 | 300 mm dia. |
| 194 | 350 mm dia. |
| 195 | 400 mm dia. |
| 196 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge;Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. (BOTH SIDE EPOXY) |
| 197 | 300 mm dia 5 mm th |
| 198 | 350 mm dia 5 mm th |
| 199 | 400 mm dia 5 mm th. |
| 200 | 450 mm dia 5 mm th. |
| 201 | 500 mm dia 5 mm th. |
| 202 | Supply of ERW M.S. black casing pipe ISI marked {IS:1239(Part-1:2004)} medium of following sizes at site of work. |
| 203 | 100 mm dia NB (Thickness of pipe 4.5 mm & mass of tube 12.50 Kg/m) |
| 204 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes |
| 205 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) |
| 206 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) |
| 207 | 250 mm dia NB (Thickness of pipe 7.1 mm & mass of tube 46.57 Kg/m) |
| 208 | MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) |
| 209 | Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum |
| 210 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase upto 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply. |
| 211 | 3 core 4.0 Sq.mm |
| 212 | Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification. ( For Railway crossing) |
| 213 | 300 mm Dia 8 mm thick casing pipe. |
| 214 | 400 mm Dia 8 mm thick casing pipe . |
| 215 | 500 mm Dia 8 mm thick casing pipe . |
| 216 | Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503-2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating . |
| 217 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 218 | Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coil including excavation, shoring/ strutting, preparation, maintain the thrust and including, road dismantling,excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work. Excluding cost of pipe line.Note: Trenchless laying shall be done only for laying of pipe line (rising main) and road crossing of distribution pipe line under CC/BT roads. |
| 219 | Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance ofdiversion. |
| 220 | PCC- M- 25 |
| 221 | Construction of RCC Valve Chamber of following size including required earth work (PCC M-10, 10 CM th.) RCC vertical walls in M-25 grade cement concrete of suitable size as per GAD including providing fixing of Reinforced Ferro cement Drain cover designed for class \\"AA\\" loading complete as per specification and scope of work. ( Item based on PWD BSR) |
| 222 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/WARS approved for drinking water |
| 223 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. |
| 224 | HDPE PE-80 PN-6 |
| 225 | 75 mm dia |
| 226 | 90 mm dia |
| 227 | 110 mm dia |
| 228 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. |
| 229 | HDPE PE-80 PN-6 |
| 230 | 125 mm dia |
| 231 | 140 mm dia |
| 232 | 160 mm dia |
| 233 | 180 mm dia |
| 234 | 200 mm dia |
| 235 | 225 mm dia |
| 236 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 or screwed Screwed type shall have extcrnal pipe threads conforming to IS 554 Fastners - CS Epoxy paint inside outside of food grade safe for drinking water ,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 237 | Class PN 1.0 |
| 238 | 25 mm S-1 Type |
| 239 | 40 mm S-1 Type |
| 240 | SITC of Bulk Flow Meter with removable mechanism class \\"B\\" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 241 | BFM 80 mm |
| 242 | BFM100 mm |
| 243 | BFM 150 mm |
| 244 | VTC - Construction of village lavel transfer chamber and meter room, work including require earth work PCC 1:4:8 under floor & for foundation, walls of chmber constrected by RCC M-20, with Fiber reinforced Ferro cement drain cover (light duty). Construction of brick masonary meter room above GL, 23 cm thick Brick masonary walls over stone masonary foundation coverd by RCC roof, CC flooring, MS sheet door with lackin arrangments .(Based on RUIDP 2017 BSR) |
| 245 | Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenence as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. Plain ended CI specials including tail piece, spigot end and socketend. |
| 246 | Up to 300 mm dia |
| 247 | Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) |
| 248 | 80 mm thick. |
| 249 | Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PVC/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including MS/PVC saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipe in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. |
| 250 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
| 251 | Providing Household Tap Connection as per technical specification and approved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. |
| 252 | For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. |
| 253 | P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. |
| 254 | Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. |
| 255 | Add extra over item no 1.21 & 1.22 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. |
| 256 | Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI No. 102 DO No. 98 AI No. 22 AO No. 16 MCB 16A DP No. 2 MCB 6A DP No. 6 SMPS 100-240VAC/ 4.5A / 24 VDC No. 1 Selector Switch (Auto/Manual) & Local / Remote No. 2 Control Relays Lot 1 Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with Electronic Hooter No. 1 Control Transformer 200VA No. 1 Emergency STOP Push Button No. 1 Panel Cooling Fan & Filter No. 2 Panel Light with Door Switch, 7W No. 1 Control Indication Lamp for 24VDC, 220VAC No. 3 Push Button No. 3 Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc Lot 1 panel Hardware, lugs, terminations, ferrules, name plate Etc. Lot 1 UTILITY SOCKET 16A, 3 PIN No. 2 HMI Display 12 Inch, Colour No. 1 Isolators Dual Output, 24VDC Lot 1 |
| 257 | Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI No. 62, DO No. 58 AI No. 14 AO No. 6 MCB 16A DP No. 2 MCB 6A DP No. 6 SMPS 100-240VAC/ 4.5A / 24 VDC No. 1 Selector Switch (Auto/Manual) & Local / Remote No. 2 Control Relays Lot 1 Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with No. 1 Electronic Hooter No. 1 Control Transformer 200VA No. 1 Emergency STOP Push Button No. 1 Panel Cooling Fan & Filter No. 2 Panel Light with Door Switch, 7W No. 1 Control Indication Lamp for 24VDC, 220VAC No. 3 Push Button No. 3 Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc Lot 1 panel Hardware, lugs, terminations, ferrules, name plate Etc. Lot 1 UTILITY SOCKET 16A, 3 PIN No. 2 HMI Display 10 Inch, Colour No. 1 Isolators Dual Output, 24VDC Lot 1 |
| 258 | SITC of Intelligent Manageable Ethernet Switches providing 24 x 10/100/1000 Fast Ethernet ports- and 2 dual purpose uplink (provision for Copper / Fibre Giga connectivity) with LAN based Software. The LAN based S/W supports enhanced integrated security, including Network Admission Control (NAC), advanced quality of service (QoS), availability and scalable management to enable new converged applications |
| 259 | 4G/3G GPRS VPN modem with Ethernet bridge/ router/ serial server (RS232/485) Interface to MCC Room ( Wireless Gateway) |
| 260 | Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, Single Phase 230 V, 50 Hz with 2 hour backup SMF battery bank as per specification |
| 261 | Providing and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 262 | 1 SQMM |
| 263 | 24 CORE |
| 264 | Providing and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 265 | 1 SQMM |
| 266 | 1 PAIR |
| 267 | Providing and laying XLPE/PVC insulated & PVC sheathed armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering |
| 268 | 6C x 1.5 sq.mm |
| 269 | 4C x 1.5 sq.mm |
| 270 | Providing, Installation, Testing and Commissioning of Ultrasonic Level Transmitter : Principle : Time of Flight / Sensor MOC PP / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66/ Accuracy ±1% |
| 271 | Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 \\"NPT (M) / Accuracy: 0.15% Protection: IP67 |
| 272 | Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerine filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminium |
| 273 | Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material of sensor and other wetted parts: SS type 316, Housing: Die cast aluminium, Switch type: Microswitch, Repeatability: ± 1% of span, Switch Contacts: 2 NO + 2 NC |
| 274 | Providing, installation, testing and commissioning of Level Switch (Conductivity) Conductivity Probes, Probe insulation: Teflon, Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminium |
| 275 | Rigid for lengths of up to 3 Mtr. |
| 276 | Supply, Installation, Testing and Commissioning of Online Multichannel and Multiparameter Transmitter/Converter for Liquid Analysis Sensors as per CPCB/SPCB guidelines. |
| 277 | Dual Channel (2 Sensor Input) |
| 278 | FRC Sensor Range :- 0.05 to 20 mg/l |
| 279 | Modular RTU complete with DI, DO, AI and modbus communication ports and power supply 24 VDC or for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with integrated modem; connection to control center via Tele Control Basic, DNP3, IEC60870-5-104 and Communication protocols, on-board I/Os min. (8 DI, 4 DQ, 2 AI), configuration and diagnostics per web interface, RJ45 port, mobile communications antenna (GSM/UMTS), Mini SIM card, with adapter Micro SIM card also, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for Compact RTU Location, wall/floor mounted along with wiring and related accessories and arrangement of mounting of RTU, Modem having IP-5X Protection. Panels shall be self-fabricate type only with Canopy. |
| 280 | Plate Earthing as per PWD specification for electrical Works as per IS:3043 with copper Earth plate of size 300mm x 300mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 281 | Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 282 | 25mm x 3mm G.I. ( Hot Dipped ) Strip |
| 283 | Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation of PV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document. |
| 284 | Supply of GSM /GPRS based data transmitter for Bulk Flowmeter (woltman Pulse Output only ), Battery Powered -7.4V, battery life 3-5 Years, (1 no Data transmit in a day), 4-20mA From Pressure RS485 Display-16*2 LCD, Encloser-165*120*65 mm, ABS Protection-IP65, Operating tempreature -55 Deg. C |
| 285 | Supply installation testing & Commissioning of star rated Copper wound distribution Transformer ( All the distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+5% to - 10% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953 , Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 286 | 100KVA |
| 287 | 160KVA |
| 288 | 250KVA |
| 289 | 400KVA |
| 290 | 200KVA |
| 291 | Supply , Installation, Testing and Comissioning of 11KV, 630 A, 25 kA / 1 Sec, SF6 / VCB Indoor type panel HT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steel , With Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio ( 15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 4 / 8 /10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection ( High oil temperature , Buchholz protection ,high winding temperature), power pack 2 x 12 V,etc complete in all respect Ready To Use(RTU),OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab type test reports before execution complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 292 | Plate Earthing as per PWD specification for electrical Works as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 293 | Plate Earthing as per PWD specification for electrical Works as per IS:3043 with copper Earth plate of size 300mm x 300mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 294 | G.I. pipe 50 mm dia as per IS:1239 FOR EARTHING SYSTEM |
| 295 | Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 296 | 50mm x 6mm copper strip |
| 297 | 50mm x 6mm G.I. ( Hot Dipped ) Strip |
| 298 | 32mm x6mm G.I. ( Hot Dipped ) Strip |
| 299 | 25mm x 6mm G.I. ( Hot Dipped ) Strip |
| 300 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. |
| 301 | Armoured Cable |
| 302 | 300 SQMM, 3.5 CORE |
| 303 | 400 SQMM, 3.5 CORE |
| 304 | 120 SQMM, 3 CORE |
| 305 | 240 SQMM, 3 CORE |
| 306 | 150 SQMM, 3 CORE |
| 307 | 95 SQMM, 3 CORE |
| 308 | 120 SQMM, 3.5 CORE |
| 309 | 50 SQMM, 3 CORE |
| 310 | 70 SQMM, 3 CORE |
| 311 | 10.0 SQMM, 3 CORE |
| 312 | 35 SQMM, 3 CORE |
| 313 | 16 SQMM, 3 CORE |
| 314 | 25 SQMM, 3 CORE |
| 315 | 4.0 SQMM, 3 CORE |
| 316 | Supply, Fabricating & installing following sizes of powder coated ladder type M.S. cable trays with rungs at span of 250 mm including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/wall with MS suspenders including bolts & nuts ,fastners, supports, painting suspenders etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 317 | 450mm x 50mm x 2.0mm |
| 318 | 600mm x 50mm x 2.0mm |
| 319 | Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 320 | 100mm x 50mm x 1.6mm |
| 321 | 150mm x 50mm x 1.6mm |
| 322 | 300mm x 50mm x 1.6mm |
| 323 | 450mm x 50mm x 2.0mm |
| 324 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 325 | 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV |
| 326 | SITC of floor mounted drowout type PMCC (Indoor, Dury, dust proff IP-4x front operated with 2 mm thick sheet metal compartmentalised) with all accessible parts, head shrinkable sleeves, SMC/DMC bus bar supports, padlocking facility on outgoing feeders etc. |
| 327 | Incommer feeder for transformer 630A/800A,50KA,ACB 3 pole,Al Bus Bars,Digital Multifunction meter compatable to SCADA, metering, Protection CT's,IDMT 3O/C&1 E/F, indicating lamps,control fuse ,wiring etc.complete in all respect of the size appxo 900(D)X.2400(H)X1000(D) |
| 328 | Bus Coupler Feeder, 630/800 A ACB ,50KA,3 Pole without release with Al Bus Bars, Protection CT's ,IDMT 3 O/C & 1 E/F,Indicating Lamps,Control Fses and wiring etc.complete in all respect. (Size : 900(W) x 2400 (H) x 1000 (D) |
| 329 | 250 A MCCB Incomer with metering CTs , multi fuction meter compatible to scada ,Ampermeter with SS,Voltmeter with SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D) |
| 330 | SITC of floor mounted drowout type PMCC (Indoor, Dury, dust proff IP-4x front operated with 2 mm thick sheet metal compartmentalised) with all accessible parts, head shrinkable sleeves, SMC/DMC bus bar supports, padlocking facility on outgoing feeders etc. |
| 331 | Incommer feeder for transformer 1600 A,50KA,ACB 3 pole,Al Bus Bars, Digital Multifunction meter compatable to SCADA,metering,Protection CT's, IDMT 3O/C&1 E/F,indicating lamps,control fuse ,wiring etc.complete in all respect of the size appxo 900(D)X.2400(H)X1000(D) |
| 332 | Bus Coupler Feeder, 1600 A ACB,50KA, 3 Pole without release with Al Bus Bars, Protection CT's ,IDMT 3 O/C & 1 E/F,Indicating Lamps,Control Fses and wiring etc.complete in all respect. (Size : 900(W) x 2400 (H) x 1000 (D) |
| 333 | 400 A MCCB Incomer with Meetering CT's,multi fuction meter compatible to scada ,Ampermeter with SS,Voltmeter with SS,Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D) |
| 334 | 250 A MCCB as outgoing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps, Control Fuse,wiring etc.complete in all respect. Size:900(W)X2400(H)X1000(D) |
| 335 | 125 A MCCB as outgoing CT's,Ampermeter with SS, Voltmeter with SS, Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:600(W)X2400(H)X1000(D) |
| 336 | MCCB up to 100A as outing CT's,Ampermeter with SS,Voltmeter with SS, Indicating Lamps,Control Fuse,wiring etc.complete in all respect. Size:600(W)X2400(H)X1000(D) |
| 337 | SITC of Draw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker (ACB) as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, earth fault and with separate LED indication for each type of fault , Password protected relase (trip mechanisum) shall confirm to EMI/ EMC test , LCD/LED display , Thermal memory , pollution degree 4, trip free mechanisum , suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping fearute , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electrical operation 10,000 upto 2000 A rating and 5,000 for 2500 A. including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 338 | Microprocessor based release Draw out type ( Motorised charging type ) 3Pole |
| 339 | 800 A Rating , 50kA |
| 340 | Supply and fixing of following accessories for Air circuit breaker (ACB) compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 341 | Shunt Trip Release |
| 342 | Under Voltage Release |
| 343 | Earth Fault Release |
| 344 | Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) as per PWD specification for electrical Works, ISI marked IS:13340-41 / conforming to IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.35 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 250 times of rated current, including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 345 | Heavy duty Three phase 480 V, 50 Hz cylindrical capacitor (Bank) |
| 346 | Providing & Fixing of IP54 on front microprocessor based three phase sensing power factor correction relay , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, VTHD, ITHD, metering facility as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 347 | 12 to 14 stage |
| 348 | Providing & Fixing of ISO certified company made Cam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 349 | 10 AMP |
| 350 | SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. |
| 351 | 110KW |
| 352 | 200KW |
| 353 | S & F of Star delta Starter with MCB, Main and Aux Contactor, O/L Relay, L/R Selector Switch,3 Indicating lamps, Start-Stop Push Button ,Control MCB with panel with all accessories with following rating |
| 354 | 7.5 KW to 9.3KW |
| 355 | 18.5KW |
| 356 | 433V APFC Panel in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 357 | 433V Indoor LT Switchgear Panel for POST CHLORINATION SYSTEM in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latest IS/ IEC, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 4X, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor PCC panel switches gear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based relays, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge. |
| 358 | SITC of Local Push Button station fabricated with 16 SWG CRCA sheet, painted with polyster Powder coated finish after chemical treatment with Folliwng items and accessories:- i Shrouded Type push button with 2 NO Contacts element for Start/forward-reverse. ii Lockable Mushroom head type push buuton with 2 NC Contact element. iii 2.5 Sqmm clipon type terminals as requried with 20% spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 359 | Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 360 | Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.) |
| 361 | 7 Mtr. |
| 362 | Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 363 | Single arm overhang |
| 364 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 365 | LED Street Light fixture 100 Watt |
| 366 | Providing & Fixing of thermoplastic Polycarbonate cable junction boxes with IP66 rating of protection & knock out for cable entry/out of following sizes including clamps for holding the box, including cost of DIN rail for MCB mounting, 10 Sqmm 4 pole connectors for cables terminals, threaded cable glands made of polyamide material etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 367 | 175mm X 150mm X100mm |
| 368 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 369 | 32 mm Dia. |
| 370 | Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 371 | 3 core 120.0 Sq.mm |
| 372 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for 11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 373 | 11 KV End Termination Kit Indoor type |
| 374 | 3 core 120/150/185 Sq.mm |
| 375 | 11 KV End Termination Kit Outdoor type |
| 376 | 3 core 120/150/185 Sq.mm |
| 377 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 378 | Double pole MCB |
| 379 | 6 A to 32 A rating |
| 380 | Supply , Installation, Testing and Comissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB. NABL accredeated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391(Part-2) 2018 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 381 | Invertor Type |
| 382 | 1.8/2.0 TR with 5 star rating of BEE (ISEER not less then 4.5 ) |
| 383 | Supply & Fixing of FR PVC insulated & sheathed 3 core flexible copper conductor as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 384 | 6.0 Sq.mm |
| 385 | Supply and installation of UL listed, CPRI tested copper bounded steel electrode of minimum 17.2 mm dia. (as per IEC 62561-2 ) With a minimum coating thickness of 250 microns and length of 3 meters, filled with anti corrosive conductive compounds with the permanent sealings at both the ends as per point mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second . (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 386 | Providing & Fixing of copper tape 20mm x 3 mm on parapet or surface of wall fixed with porcelain or bakelite insulator (SP-35) in vertical/horizontal run as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 387 | 20mm x 3mm copper strip |
| 388 | Mesh earthing as per IS:3043 with copper earth strip of size 20 mm x 3 mm to form a mesh of size 3000 mm x 1000 mm in horizontal formation to create equal sections of 500 mm x 500 mm by means of 10 mm brass bolts, & nuts with spring washer, embodying 1 mtr. Below the ground level, refilling the pit by alternative layers of charcoal & salt up to 500 mm with 20 mm dia, 20mm GI 'B' class watering pipe and 12 mm G I 'B' class pipe for the earth wire including all accessories like nuts, bolts, wire mesh funnel and brick masonary finished chamber covered with hinged CI cover and locking arrangement of size 300 mm x 300 mm complete in all respect. |
| 389 | Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 390 | High Power LED Flood Light 100W |
| 391 | Upto 3.7 KW DOL Starter Feeder with MCB, Main and Aux Contactor, O/L Relay, L/R Selector Switch,3 Indicating lamps, Start-Stop Push Button ,Control MCB Size : 600 (W) x 400 (H) x 600 (D) |
| 392 | From 3.3 KW to 7.5 KW DOL Starter Feeder with MCB, Main and Aux Contactor, O/L Relay, L/R Selector Switch,3 Indicating lamps, Start-Stop Push Button ,Control MCB (Size : 600 (W) x 400 (H) x 600 (D) |
| 393 | Part N- Operation and Maintenance |
| 394 | O & M Cost for all work executed by the contractor from pump house to VTC including SCADA, Basic Service Charges, Administration and Management, Running of Office, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, Consumables, Spare Parts as per Scope of Work & terms & conditions of contract. Complete job for 10 years after 1 year defect liability period. |
| 395 | 1st year after DLP |
| 396 | 2nd year after DLP |
| 397 | 3rd year after DLP |
| 398 | 4th year after DLP |
| 399 | 5th year after DLP |
| 400 | 6th year after DLP |
| 401 | 7th year after DLP |
| 402 | 8th year after DLP |
| 403 | 9th year after DLP |
| 404 | 10th year after DLP Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender