Tender For Removal Of Leakages From Various Type & Size Of Pipe Line Under Jurisdiction Of Junior Engineer Ranawas And Jojawar Under Sub. Dn. Marwar Junction Of Dn. Sojat City. {As Per Phed O&M Bsr 2020 Jodhpur Region-I(Distt-Jodhpur &Pali)}
Tender Overview
Project Description
Tender for Removal Of Leakages From Various Type & Size Of Pipe Line Under Jurisdiction Of Junior Engineer Ranawas And Jojawar Under Sub. Dn. Marwar Junction Of Dn. Sojat City. {As Per Phed O&M Bsr 2020 Jodhpur Region-I(Distt-Jodhpur &Pali)}
BOQ
| Sl. No. | Item Description |
| 1 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)In all type Soil AC/PVC/HDPE pipe50/63/75mm |
| 2 | 80/90mm |
| 3 | 100/110mm |
| 4 | 125/140mm |
| 5 | 150/160/180mm |
| 6 | 200/225mm |
| 7 | 250/280mm |
| 8 | Add on above item no. 1.1.1 for B.T. Road |
| 9 | Add on above item no. 1.1.1 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only. |
| 10 | Add on above no. 1.1.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. |
| 11 | Add on above no. 1.1.1 item if depth of pipeline is above 3.0 mtr. |
| 12 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)In all type Soil100mm |
| 13 | 125mm |
| 14 | 150mm |
| 15 | 200mm |
| 16 | Add on above item no. 1.2.1 for B.T. Road |
| 17 | Add on above item no. 1.2.1 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only. |
| 18 | Add on above no. 1.2.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. |
| 19 | Add on above no. 1.2.1 item if depth of pipeline is above 3.0 mtr. |
| 20 | Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost)In all type Soil80 mm |
| 21 | 100 mm |
| 22 | 125 mm |
| 23 | 150 mm |
| 24 | 200 mm |
| 25 | 250 mm |
| 26 | Add on above item no. 1.4.1 for B.T. Road |
| 27 | Add on above item no. 1.4.1 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only. |
| 28 | Add on above no. 1.4.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. |
| 29 | Add on above no. 1.4.1 item if depth of pipeline is above 3.0 mtr. |
| 30 | Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.In all type Soil75 mm |
| 31 | 90/80 mm |
| 32 | 110/100 mm |
| 33 | 140/125 mm |
| 34 | 180/160/150 mm |
| 35 | 225/200 mm |
| 36 | 250 mm |
| 37 | Add on above item no. 1.5.1 for B.T. Road |
| 38 | Add on above item no. 1.5.1 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only. |
| 39 | Add on above no. 1.5.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. |
| 40 | Add on above no. 1.5.1 item if depth of pipeline is above 3.0 mtr. |
| 41 | Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).In all type Soil80 mm to 110 mm |
| 42 | 125 mm to 165 mm |
| 43 | 200 mm to 300 mm |
| 44 | Add on above item no. 1.9.1 for B.T. Road |
| 45 | Add on above item no. 1.9.1 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only. |
| 46 | Add on above no. 1.9.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. |
| 47 | Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).In all type Soil80 mm to 100 mm |
| 48 | 125 mm to 165 mm |
| 49 | 200 mm to 300 mm |
| 50 | Add on above item no. 1.10.1 for B.T. Road |
| 51 | Add on above item no. 1.10.1 for C.C. Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only. |
| 52 | Add on above no. 1.10.1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender