Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #57030948

Tender For Special Repair To Retaining Wall Of Bldg No T-03 Of 457 Fd Hosp At Aizawl Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Aizawl, Mizoram
Tender Value
43.60 Lakhs
Estimated cost
Bid Submission
05 Sep 2026
12 days left
EMD
87200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Aizawl → Mizoram
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Retaining Wall Of Bldg No T-03 Of 457 Fd Hosp At Aizawl Mil Stn

BOQ

Name of Work:- SPL REPAIR TO RETAINING WALL OF BLDG NO T-03 OF 457 FD HOSP AT AIZAWL MIL STN
Sl. No. Item Description
1B & R Division Items
2Demolition of Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
3Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
4Excavating in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense type of soil complete all as specified and directed.
5Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm complete all as specified and directed.
6Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed.
7M&L for Hand packing of stone boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed.
8M&L for PCC (1:4:8), Type D2 using 40 mm graded stone aggregate as in foundations, sub-base,filling and mass concrete complete all as specified and directed.
9M&L for Walling of square rubble ,coursed in retainning walls, abutments and similar works regular coursed,well bonded,bedded and solidly hearted,built in cement mortar(1:6) with lime/sand stone and PCC (1:3:6) type C1 precast bond stone (in lieu of stone bond stone ) set in cement mortar (1:4) brought upto courses Complete all as specified and directed Note :- (i) Precast PCC Bond stone shall be measured and paid separately against relevant item(ii) Square rubble Masonary will be measured after deducting PCC Bond stone
10M & L for precast PCC (1:3:6) type C1 using 20 mm graded stone aggregates as bond stone use for retainning wall, abutment and similar works and set in cement mortar 1:4 including neceessary formwork Complete all as specified and directed
11M&L for raised pointing to squared rubble, coursed or uncoursed in CM (1:3) complete all as specified and directed
12Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed.
13Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete all as specified and directed.
14Use and waste formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed
15M & L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed.
16M & L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in column, pillars, piers, posts, and struts complete all as specified and directed.
17M & L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5m complete all as specified and directed.
18M & L for Mild steel TMT Bars 10mm dia and over, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
19M & L for Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed
20Supply and fix 110mm bore PVC (SWR) pipes single socketed with rubber joint, in any length, laid in trenches or in floors / fixed to walls complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57030948
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.60 Lakhs
LAST DATE 05-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Retaining Wall Of Bldg No T-03 Of 457 Fd Hosp At Aizawl Mil Stn
Basic Detail
Tender No 8186A/E8
Bidding Type Tender
Location
City Aizawl
State Mizoram
Key Dates
Publish Date 15 Aug 2026
Submission Date 05 Sep 2026
Open Date 08 Sep 2026
Finance
Tender Value 43.60 Lakhs
Tender Fee 500
EMD 87200
Exemption Available
Document List
8186A-SchOfCreditformat.pdf
8186A-TP.pdf
BOQ_879227.xls
dc1df5b6-9596-4741-a380-bd1537b51a81.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

8186A-SchOfCreditformat.pdf

pdf

8186A-TP.pdf

xls

BOQ_879227.xls

html

dc1df5b6-9596-4741-a380-bd1537b51a81.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders