Tender For Repair / Maintenance Of Ht Oh Lines, Transformers, Vcbs And Connected Works At Karu And Shesharthang Area Under Ge 860 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation or for shafts, wells, cesspits, manholes, pier holes etc., not exc 10 sqm on plain and not exc 1.5 m in depth and getting out in cable/ stay assy/HT poles and getting out in hard/dense soil, complete all as specified and/ or as directed by Engr-in-Charge. |
| 2 | Excavating in trenches, not exc 1.5 m wide and not exc 3 m in depth; for foundation or for shafts, wells, cesspits, manholes, pier holes etc., not exc 10 sqm on plain and and not exc 3.0 m depth for foundation of poles and getting out in hard/dense soil, complete all as specified and/or as directed by Engr-in-Charge. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm in hard/dense soil, complete all as specified and/or as directed by Engr-in-Charge. |
| 4 | Removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and/or as directed by Engr-in-Charge. |
| 5 | Material and labour for providing PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation filling and mass concrete for pole/stay foundation including use of necessary form works for rough finished surface complete all as specified and/or as directed by Engineer-in-Charge. |
| 6 | Material and labour for providing PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) in foundation filling and mass concrete for pole/stay foundation including use of necessary form works for rough finished surface complete all as specified and/or as directed by Engr-in-Charge. |
| 7 | Material and labour for providing PCC 1:2:4, type B1 (using 40 mm graded stone aggregate) for coping of pole/ stay including necessary form work complete all as specified and/or as directed by Engr-in-Charge. |
| 8 | Material and labour for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and/or as directed by Engr-in-Charge. Note : Punned thickness only will be measured and paid for. |
| 9 | Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class HV type-1 flat size 300mm x 180mm x 40mm, complete all as specified and/ or as directed by Engr-in-Charge. |
| 10 | Supply and laying in repair of tubes galvanised \\"Light grade\\" 100 mm dia with all fittings and fixed complete to walls and ceilings or laid in floors/with pole/trenches for the protection of the underground cable complete all as specified and/ or as directed by Engr-in-Charge. |
| 11 | Dismantling and taking down insulator of any type and size from HT pole complete all as specified and/ or as directed by Engr-in-Charge. |
| 12 | Supply and fix Pin type insulator, porcelain, vitreous white/ brown including one galvanized mild steel spindle, two galvanized iron washers and one nut (galvanized iron), for size of 150 mm height, 150 mm dia for 11000 volts grade insulator complete all as specified and/or as directed by Engr-in-Charge. |
| 13 | Supply and fix polymer composite disc type insulator, grey in colour for working pressure 11000 volts complete all as specified and/or as directed by Engr-in-Charge. |
| 14 | Material and labour for dehydration of transformer oil with mobile transformer filteration plant at site with all required accessories connected to transformer and carrying out filteration of transformer oil for the desired dielectric strength i.e. not less than 30 KV at 2.5 mm gap complete all as specified and/or as directed by Engr-in-Charge.Note : Test certificate shall be submitted before and after filteration for dielectric strength. |
| 15 | Supply and filling in replacement of transformer oil of good quality for topping up transformers of capacity 200 KVA to 630 KVA, having dielectric strength not less than 50 KV, flash point not less than 135 degree Celcius, having low viscosity for filling complete all as specified and/or as directed by Engr-in-Charge.Make - Servo / Power Oil / HP |
| 16 | Material and labour for shifting of outdoor-type transformer up to 400 kVA capacity from GE 860 EWS to workshop for repair and back to GE 860 EWS after repair, which will be placed on the platform made through this contract and 11 KV on HT side, 433 Volts, 3 Phase & 4 wire on LT side complete with electrical connections on HT & LT side including all the accessories/fittings and all as specifed and/or as directed by Engr-in-Charge. |
| 17 | Dismantling of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. complete all as specified and/or as directed by Engr-in-Charge. |
| 18 | Supply and fix gang operated air break switches, HT 11 KV grade outdoor type, 3 phase, triple pole, capacity of 400 amps rating, mounted on polymer based 12 insulators, vertical mounting with fixed and moving contacts with locking arrangement, fixing the gang operated switch on existing two/four pole structure and making all jumper connections with insulated leads of suitable size with line tops etc. complete all as specified and/or as directed by Engr-in-Charge. Make - Jaipuria or equivalent make as approved by GE. |
| 19 | Supply and fix in replacement danger notice plate of 1.6 mm thick and size not be less than 25x20 cm, made of mild steel sheet, vitreous white enamelled, with letters i.e. \\"DANGER 11000 VOLTS\\" (in English as well as in HINDI) and conventional skull and bones signal in red colour and fixed with MS clamps, nuts, bolts and washers of suitable size, complete all as specified and/or as directed by Engr-in-Charge. |
| 20 | Supply and erect in replacement Steel tubular swaged poles complete with cast iron steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metre long) including drilling of necessary holes & painting complete all as specified and/or as directed by Engr-in-Charge. |
| 21 | Supply and erect in replacement Steel tubular swaged poles complete with cast iron steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (09 metre long) including drilling of necessary holes & painting, complete all as specified and/or as directed by Engr-in-Charge. |
| 22 | Supply and fix in replacement of stay assembly set comprising of 14mm long GI stay bow, 2150mm long stay rod 20mm dia with threaded end GI nut bolt and washers, thimble including 300x300x6mm MS stay plate and exposed surfaces shall be given two coats of aluminium paint over a coat of red oxide primer with all accessories as shown in electrical plate No 1 of MES schedule part-I, complete all as specified and/or as directed by Engr-in-Charge. Note : Excavation, earth work, PCC & insulator shall be measured and paid separately. |
| 23 | Supply and fix in replacement of cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer and preparing the surface, complete all as specified and/or as directed by Engr-in-Charge. |
| 24 | Supply, laying, testing and commissioning in replacement of semi conducting, compound conductor, screened PVC bedded, galvanized steel strip or wire armoured XLPE insulated heavy duty 11000 Volts grade cable with stranded aluminium conductor of size 185 Sqmm 3 core confirming to IS 7098 Part-II, suitable for earthed system complete all as specified and/or as directed by Engr-in-Charge.Make : Havells/Finolex/Polycab/KEI.Notes :-(i) The end termination joint shall be measured and paid separately under respective items.(ii) Excavation, earth work, sand cushioning and protection cover will be measured and paid for separately. |
| 25 | All as per Srl item No 24.00 above, but of size 95 Sqmm 3 core. |
| 26 | All as per Srl item No 24.00 above, but of size 300 Sqmm 3 core. Please Enable Macros to View BoQ information |
| 27 | All as per Srl item No 24.00 above, but of size 300 Sqmm 3 core. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender