Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57030402

Tender For Special Repair To Bldg. No T-1245, T-1246, T-1301, T-1302 And T-1307 Under Ge (North) Bathinda At Bathinda Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Bathinda, Punjab
Tender Value
46.67 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
5 days left
EMD
93340
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bathinda → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Bldg. No T-1245, T-1246, T-1301, T-1302 And T-1307 Under Ge (North) Bathinda At Bathinda Mil Stn

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Aug-2026 Corrigendum No 01 Financial Bid 28-Aug-2026

BOQ

Name of Work:- SPECIAL REPAIR TO BLDG. NO T-1245, T-1246, T-1301, T-1302 AND T-1307 UNDER GE (NORTH) BATHINDA AT BATHINDA MIL STN
Sl. No. Item Description
1Taking down chowkhats or frames with shutters (without taking off shutters from the frame), not exceeding 1.50 sqm each, including careful dismantling, stacking/disposal of dismantled materials as directed, and completing all works as specified and directed by the Engineer-in-Charge.
2Taking down chowkhats or frames with shutters (without taking off shutters from the frame), exceeding 1.50 sqm but not exceeding 4.00 sqm each, including careful dismantling, stacking/disposal of dismantled materials as directed, and completing all works as specified and directed by the Engineer-in-Charge.
3Taking down shutters and refixing the same in the existing opening, including necessary adjustments and all incidental works, for shutters having an area exceeding 1.00 sqm and not exceeding 2.00 sqm each, complete as specified and directed by the Engineer-in-Charge.
4Supply and fixing Factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/Chowkhat (Single Rebated) of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed. Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
5Supply and Fixing Factory made single extruded WPC (Wood Polymer Composite) solid door & other Frames/ Chowkhat (double Rebated) of size 50 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed.Note: (i) WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) Cost for M.S. hold fast/ lugs or SS dash fasteners shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
6Supply & fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) SS 150mm long Tower Bolt with Stainlessd steel screws and including Supply & fixing of 02 Nos SS 150mm long handle with Stainlessd steel screws and 300 mm SS sliding door bolt with Stainlessd steel screws complete all specified and directed by Engineer -in-charge. Note:- The rate of 02 Nos. SS 150mm long Tower Bolt . 02 Nos. SS 150mm long handle and 300 mm SS sliding door bolt is included in this item and nothing shall be paid extra on this account.
7Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed including supply and fixing following items : (a) Stainless Steel (304 Grade) Finished Butt Hinges of size 100mm - 4 nos. per leaf (Table 6 of BIS 12817-2020) BIS marked.(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf as per table 1, dia of bolt 12mm as per BIS 15833. (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding door Bolt 300 mm - 1 no. per leaf, 16mm dia as per BIS marked clause 3(iii) of BIS 15834-2020.
8Providing and fixing factory made single extruded WPC (Wood Polymer Composite) glazed/gauge skelton door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with butt hinges with necessary full body threaded star headed counter sunk S.S screws including S&F wire cloth complete all as specified and as directed including supply and fixing following items:- (a) Stainless Steel (304 Grade) Finished Butt Hinges of size 100mm - 4 nos. per leaf (Table 6 of BIS 12817-2020) BIS marked.(b) Stainless Steel (304 Grade) Finished Square Tower Bolt 200mm long - 2 nos per leaf as per table 1, dia of bolt 12mm as per BIS 15833. (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos. per leaf(d) Stainless Steel (304 Grade) Finished Sliding door Bolt 300 mm - 1 no. per leaf, 16mm dia as per BIS marked clause 3(iii) of BIS 15834-2020.(e) Stainless Steel (304 Grade) (natural finish) wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm, fixing as per manufacture
9Note for WPC/uPVC Frame/window/shutter(i) Test certificate of Manufacturer to be provided by contractor.(ii) Embossing with Barcode of Manufacturer engraved over each door Frame & shutter is mandatory. (iii) Cost for making good to cutting holes/dismantled portion during taking down old with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate or cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (iv) The cost of all other connected accessories, fixing material shall deemed to be included in the quoted unit rate.
10Material and labour for Providing and fixing aluminium work with Polyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conformikng to IS:733 and IS :1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions i.e at top , bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth , rust free, straight, mitred and jointed mechanically wherever required including aluminium cleat angle, aluminium snap beading for glazing/ paneling , C.P. brass/ stainless steel screws, all complete all as specified and directed by Engineer-in-charge .Note :- (i) Weight of aluminium sections , aluminium cleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminium peg stays & aluminium snap beading shall be physically ascertained through a board of officers convened by GE and payment shall be made only after ascertaining the actual weight of aluminium at site.(ii) The rate of material and labour for providing the EPDM rubber, neoprene gasket , C.P. brass / stainless steel screws are included in this item and nothing shall be paid extra on this account. (iii) During considering the weight of aluminium sections , aluminium cleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminium peg stays & aluminium snap beading , the weight of EPDM rubber, neoprene gasket , C.P. brass/ stainless steel screws shall not be considered for measurments and payments. Only the weight of the aluminium sections , aluminium cleat angles, aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminium peg stays & aluminium snap beading shall be considered and measurment and payment shall be made accourdingly.(iv) During the weight of aluminium sections , aluminium cleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminium peg stays & aluminium snap beading ,the weight of polyester powder coating 50 micron shall not be considered for weight but the rate of material and labour for providing polyester powder coating 50 micron is included in this item and nothing shall be paid extra on this account. (v) Glazing /Paneling and wire mesh shall be measured and paid seperately. (v)The board shall be duly countersigned by GE shall enclosed with Final Bill .
11Supply and fixing floor door stopper 150mm size of aluminum alloy body and tounge, anodised with hard drawn steel spring complete all as specified and as directed by Engr-in charge.
12Supplying and fixing window curtain blinds, decorated zebra type, including finials, stop rollers, etc., as per site requirements, fixed to wall with all necessary fixing accessories, including taking down old existing curtain rods of any description and removing the same, complete as specified and directed by the Engineer-in-Charge.
13Supplying and fixing 12 mm size mesh stainless steel wire netting of 1.40 mm diameter, fixed with stainless steel tacks/staples, including cutting, fitting, and all necessary accessories, complete as specified.
14Supplying and fixing in repair, 12 mm size mesh stainless steel wire netting of 1.40 mm diameter, fixed with stainless steel tacks/staples, including cutting, patching, fitting and all necessary accessories, complete as specified.
15Supply & fixing 4.0 mm thick, sheet glass ordinary quality not exceeding 0.50 sqm in each pane complete all as specified and as directed by Engineer-in- charge.
16Supply & fixing 5.5mm thick tinted sheet glass ordinary quality in squares / retangular in any size of each pane as in aluminium doors, window, partitions and similar work including cutting to shape complete all as specified and as directed by Engr-in-charge
17Supply & fixing 4.00 mm thick, figured glass, pin head type not exceeding 0.50 sqm in each pane complete all as specified and as directed by Engineer-in- charge.
18Dismantling of floor, hearth or wall tiling including cement mortar bedding/backing, etc., carefully removing serviceable tiles for stacking and storing at specified location, removing unserviceable materials and disposal of rubbish off the premises, complete as specified and directed by the Engineer-in-Charge.
19Material and labour for providing and fixing anti-skid vitrified tiles of approved shade, matte finish, coloured design, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, minimum 7 mm thick, premium quality, water absorption between 3% to 6%, straight-edged, stain-free finish, laid in floors, set and jointed in Type-2 tile adhesive (thin bed) conforming to IS 15477:2019, including screed bed, surface preparation, necessary cutting to required sizes and shapes, laying, alignment, leveling, cleaning and finishing, complete in all respects, as specified and as directed by the Engineer-in-Charge.
20Material and labour for providing and fixing double charged vitrified tiles of approved shade, design, and pattern (including light, dark, and highlighter tiles as approved), area of each tile exceeding 0.18 sqm and not exceeding 0.36 sqm, 9–10 mm thick, premium quality, water absorption less than 0.5%, straight-edged, stain-free, glossy finish, laid in floors and skirting, set and jointed in Type-2 tile adhesive (thin bed) conforming to IS 15477:2019, including screed bed, surface preparation, cutting to required sizes and shapes, fixing, alignment, leveling, cleaning and finishing, complete in all respects, as specified and as directed by the Engineer-in-Charge.
21Supply and fixing in repairs stainless steel curtain rod of 25 mm dia, including brackets and holders made out of stainless steel sheet of grade X02Cr19Ni10 (304 S2), with surface finish No. 4 conforming to IS 6911:2017, of approved quality, including removal of existing damaged curtain rod, fixing in position with necessary screws, rawl plugs and accessories, ensuring proper alignment, firm support and smooth installation, complete in all respects, as specified and as directed by the Engineer-in-Charge.
22Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets of any thickness and type, including cover fillets, careful removal, handling and disposal of dismantled materials, complete as specified and directed by the Engineer-in-Charge.
23Supply and fixing Gl powder coated frame work 605 mm X 605 mm for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 600x600x 6-7 mm thick both side PVC laminated Gypsum board in grid fixed in false ceiling grid as per above specifications complete all as specified and as directed by Engineer-in-Charge.
24M&L for Material and labour for PVC sheet wall paneling of thickness 5 mm (±0.25 mm) consisting of panels of desired size stuck on inner framework of 50 mm wide strips of 5 mm (±0.25 mm) thick Prelam PVC sheet. The panel & strips shall be sheet of Density 600 kg per cum. The strips should have in their center a grove of 6 mm width and 1 mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 255 mm between two PVC strips. The PVC strips shall be fixed to the wall using 65 mm long mild steel screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200 mm. A groove of 2 mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a Strips of 5 mm (±0.25 mm) thick PVC sheet of width 75 mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement including Dismantling of wall panelling of any type including cover fillet and frame work complete all as specified and as directed. Solid PVC wall lining consisting of 5mm thk plain colour PVC sheet inclusive of solvent cement and fixing at site onPVC frame as per specification and drawing.
25Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and removing from site complete all as specified and as directed by Engineer-in- charge.
26Supply and fixing Pre-painted galvalume aluminum zinc coating mass 150AZ corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa coating mass in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.Note :- Material test certificate and authentication should be provided by the manufacturing company.
27Supply and fixing Pre-painted galvalume aluminum zinc coating mass 150AZ plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa coating mass in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.Note :- Material test certificate and authentication should be provided by the manufacturing company.
28Supplying and fixing 60 mm thick factory-manufactured reinforced autoclaved aerated concrete (AAC) wall panels of size 1.20 m × 3.60 m, of approved make, density and grade, reinforced with anti-corrosive treated steel bars, fixed vertically/horizontally as specified using approved steel connectors, anchor plates, brackets and fasteners, including polymer-modified thin-bed mortar/approved adhesive for joint filling, finishing, lifting, handling, scaffolding and all incidental works required for complete installation, complete as specified and directed by the Engineer-in-Charge.
29Supply and fixing in replacement Bib taps, CP with wall flange screwed for 15mm bore brass ferrule and fixed in position complete all as specified.Make: Jaquar (Cat No VGP - 81037) (VIGNETTE Prime) or equivalent from Cera (Valentina Single Lever Series) or equivalent from Hindware (Fluid Series) or Techno commercial equivalent in make mentioned in Appendix 'B'.
30Supply and fixing in repair Vitreous China wash down water closet pan (pedestal pattern), white including connection to drain (for out going pipe) and to Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed. pipe, antisyphonage pipe with integral foot rest with CI 'P' ot 'S' trap and fitting in PCC 1:4:8 20mm aggregate, 150mm thk all round and finished just below level of rim of pan recieve the floor finishing all as specified.
31Supplying and fixing replacement glass shelf of 550 mm length with CP (chrome plated) fancy type brackets/railing, including necessary fittings, fixing accessories, alignment approved by GE and all incidental works, complete as specified and directed.
32Supply and fixing in replacement toilet roll holder of approved quality and make, complete with all necessary fixing accessories, including removal of existing damaged holder, drilling/plugging of wall as required, fixing in proper position with alignment and firm support, ensuring stable installation, complete in all respects, as specified and as directed by the Engineer-in-Charge.Make: Jaquar Cat Part No. ACN-1151N or techno-commercial equivalent
33Supply and fixing in repairs 10 litre capacity PVC valveless syphonic action type low level flushing cistern, white, complete with inlet, ball valve, float and handle, including brackets and PVC connections 15 mm size with PTMT nuts of 450 mm length, dismantling and taking out old unserviceable cistern and connections, connecting new cistern, and making good disturbed portion, complete all as specified and directed by the Engineer-in-Charge.
34Supply and fixing Angular Stop Cock with wall flange, CP, screwed down, screwed for 15mm bore brass ferrule or for union and fixed in position complete all as specified and as directed.Make : Jaquar Cat No. VGP-81053 or Techno commercial equivalent in make mentioned in Appendix 'B'
35Supply and fixing in repairs 15 mm dia PVC connection with PTMT nuts, 600 mm long, including dismantling of existing unserviceable connection if required, making leakproof joints and complete all as specified and directed by the Engineer-in-Charge.
36Supply & fixing in replacement vitreous china wash basin, white, flat back, of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe (flexible) 600mm long including cast iron brackets (embedded in wall upto 110 mm depth, cutting and making good the walls with PCC and cement mortar) and cutting for and pinning in end of bracket or erecting with long screwed shanks & fly-nuts, sealing gap between wall and basin with silicone sealant, complete all as specified and as directed.
37Supply and fixing in replacement of C.P. brass pillar tap, long neck type with aerator, screwed to 15 mm bore brass ferrule/PVC connection and fixed in position, including dismantling/removal of the existing pillar tap, providing necessary jointing materials, making leak-proof connections, testing for satisfactory operation and leakage, and making good any disturbed surface, complete in all respects, all as specified and as directed by the Engineer-in-Charge.Make: Jaquar (Cat. No. CON-021KN) or techno-commercial equivalent make approved and listed in Appendix ‘B’.
38Supply and fixing in replacement PVC Bathroom mirror cabinet of appx size 450mm X 350mm X 140mm / 450mm X 380mm X 140mm (Compact Mirror Cabinet, Concealed shelves) approved quality complete all as specified and as directed.
39Supplying and fixing in repair chromium plated towel ring, fixed with and including chromium plated brass screws and wooden/plastic cleats, having minimum weight 90 grams, complete with all fittings and accessories as specified.
40Supplying and fixing in repair soap dish of approximate size 160 × 160 × 90 mm, fixed with chromium plated brass screws, including all necessary fittings and accessories, complete as specified and directed by the Engineer-in-Charge.
41Supply and fixing in replacement sheet glass corner assembly of 300X300mm/250x250mm for corners consisting of 5.5mm thick glass shelf and with bevelled edges/hatching of edges fixed with stainless steel 'D' bracket fixed and railing complete all as specified and as directed.Cat part No ACN-1173 of Jaquar or Techno commercial equivalent in make mentioned in Appx 'B'
42Taking down steel tubing 15 mm bore and Taking down 15 mm bore steel tubing and connections, including careful dismantling, removal of fittings, handling and disposal/stacking of dismantled materials as directed, complete as specified and directed by the Engineer-in-Charge. complete all as specified and directed by Engr in charge
43Fixing only tubes of any grade, 15 mm bore, to walls, ceilings or floors, including providing new fittings as required. Serviceable galvanised tubes retrieved from respective dismantling items shall be laid under this item. Including all necessary fixing accessories, supports and incidental works, complete as specified and directed by the Engineer-in-Charge.
44Supplying and fixing 15 mm bore medium grade galvanised tube with all necessary fittings, fixed complete concealed, including groove cutting for concealing in walls and ceilings or laying in floors, making good the surface after fixing, and all incidental works, complete as specified and directed by the Engineer-in-Charge.
45Taking down steel tubing 20 mm bore and Taking down 15 mm bore steel tubing and connections, including careful dismantling, removal of fittings, handling and disposal/stacking of dismantled materials as directed, complete as specified and directed by the Engineer-in-Charge. complete all as specified and directed by Engr in charge
46Fixing only tubes of any grade, 20 mm bore, to walls, ceilings or floors, including providing new fittings as required. Serviceable galvanised tubes retrieved from respective dismantling items shall be laid under this item. Including all necessary fixing accessories, supports and incidental works, complete as specified and directed by the Engineer-in-Charge.
47Supplying and fixing 20 mm bore medium grade galvanised tube with all necessary fittings, fixed complete concealed, including groove cutting for concealing in walls and ceilings or laying in floors, making good the surface after fixing, and all incidental works, complete as specified and directed by the Engineer-in-Charge.
48Supply & fixing Rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996, any colour white colour or as directed, of capacity 500 litres, hoisted and fixed in position including making inlet and out let connection including ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe and suitable size of gate valve including dismantling/taking down old water storage tanks of any description and capicity with float valve and gate valve complete all as specified.
49Supplying and fixing gun metal globe or gate valve (ISI marked), heavy duty, plain both ends, suitable for 20 mm bore pipes, including all necessary fittings, jointing materials, fixing, testing and making complete in all respects as specified and directed by the Engineer-in-Charge.
50Taking down CI/AC/PVC soil, waste and vent pipes of any diameter, including all fittings, joints, supports and accessories, careful dismantling, removal and stacking/disposal of dismantled materials as directed, complete as specified and directed by the Engineer-in-Charge.
51Supplying and fixing 110 mm UPVC (SWR) pipe, single socket, pressure not less than 4 kg/cm², for waste and vent pipes, in any length, with rubber ring joints, laid and fixed to walls with PVC stack clamps, including all necessary fittings, supports and accessories, complete as specified and directed by the Engineer-in-Charge.
52Supplying and fixing 75 mm UPVC (SWR) pipe, single socket, pressure not less than 4 kg/cm², for waste and vent pipes, in any length, with rubber ring joints, laid and fixed to walls with PVC stack clamps, including all necessary fittings, supports and accessories, complete as specified and directed by the Engineer-in-Charge.
53Supplying and fixing 110 mm bore PVC (SWR) bends of any radius, provided with access door, pressure not less than 4 kg/cm², including rubber ring joints, necessary fittings and accessories, complete in all respects as specified and directed by the Engineer-in-Charge.
54Supplying and fixing 75 mm bore PVC (SWR) bends of any radius, provided with access door, pressure not less than 4 kg/cm², including rubber ring joints, necessary fittings and accessories, complete in all respects as specified and directed by the Engineer-in-Charge.
55Supplying and fixing PVC (SWR) 110 mm bore junction (Single T), equal or unequal, including rubber ring joints, necessary fittings and accessories, complete in all respects as specified and directed by the Engineer-in-Charge.
56Supplying and fixing PVC (SWR) 75 mm bore junction (Single T), equal or unequal, including rubber ring joints, necessary fittings and accessories, complete in all respects as specified and directed by the Engineer-in-Charge.
57Supplying and fixing 75 mm bore PVC (SWR) multi-floor trap, including jointing with solvent cement, necessary fittings and accessories, complete in all respects as specified and directed by the Engineer-in-Charge.
58Supplying and fixing stainless steel dome grating 125 mm dia with or without waste hole, including jointing with solvent cement, necessary fittings and accessories, complete in all respects as specified and directed by the Engineer-in-Charge.
59Demolition of cement concrete (un-reinforced) of any description in roofs, floors (other than ground floors), beams, staircases, landings, chajjas and similar suspended works, including careful dismantling, removal of debris and disposal of rubbish off the premises, complete as specified and directed by the Engineer-in-Charge.
60Material and Labour for 75mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in hardstanding, plinth protection/path etc, laid in suitable panels not exceeding 3.00m length finished even and smooth without using extra cement with 10mm joints filled with bituminous sealing compound of grade 'A' / bitumen mastic filler /sealant complete all as specified and as directed by the Engineer in charge
61Mixing and laying anti-termite treatment (ATT) along the external wall below concrete or masonry apron using approved chemical emulsion at the rate of 2.25 litres per linear metre, including drilling and plugging holes in the apron and all necessary operations, complete as specified and directed by the Engineer-in-Charge.
62Taking down cement or cement lime plaster from brick walls, etc., including raking out joints, hacking for key, scrubbing down with water and removal of debris, complete in all respects as specified and directed by the Engineer-in-Charge.
63Providing material and labour for rendering/plastering 15 mm thick with ready mix cement mortar on any face of brick walls or concrete surfaces (external surfaces), finished even and smooth without using extra cement, including preparation of surface, application, curing and all necessary operations, complete as specified and directed by the Engineer-in-Charge.
64Supplying only liquid waterproofing compound of approved quality, including packing, handling and supply complete in all respects as specified and directed by the Engineer-in-Charge.
65Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar, including all quoins, arches, pillars and other masonry works of any description, including dismantling, removal of debris and disposal of rubbish off the premises, complete as specified and directed by the Engineer-in-Charge.
66Material and labour for brick work using old size bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6, including all necessary scaffolding, curing, raking of joints and finishing complete in all respects as specified and directed by the Engineer-in-Charge.
67Material and labour for brick work using old brcks retrived , straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6, including all necessary scaffolding, curing, raking of joints and finishing complete in all respects as specified and directed by the Engineer-in-Charge.
68Material and labour for brick work in half brick thick wall using bricks, straight or curved on plan to any radius, built in cement mortar 1:4, including necessary scaffolding, curing, raking of joints and all other operations complete in all respects as specified and directed by the Engineer-in-Charge.
69Dismantling wrought iron or mild steel work of any description, including careful removal, handling, segregation of serviceable material and disposal of unserviceable materials as directed, complete in all respects as specified and directed by the Engineer-in-Charge.
70Supplying and fixing structural steel work using rolled mild steel joists, channels, angles or Tee sections, fixed independently, conforming to Fe 410-W grade steel, including cutting, drilling, welding, bolting, erection, handling and all necessary operations complete in all respects as specified and directed by the Engineer-in-Charge.
71Material and labour for providing two coats of synthetic enamel paint over new steel surfaces with one coat of red oxide primer, including preparation of surface of any description not exceeding 10 cm width or girth, cleaning, priming and finishing complete in all respects as specified and directed by the Engineer-in-Charge.
72Material and labour for preparation of old steel surface and applying two coats of synthetic enamel paint over one coat of red oxide primer, including cleaning, removal of loose paint/rust, surface preparation, application of primer and finishing coats complete in all respects as specified and directed by the Engineer-in-Charge.
73Material and labour for two coats of cement-based paint over new plastered surface, including preparation of surface, cleaning, application of coats and finishing complete in all respects as specified and directed by the Engineer-in-Charge.
74Material and labour for two coats of cement-based paint over old plastered surface, including complete removal of existing loose/defective surface, preparation of surface, cleaning, application of coats and finishing complete in all respects as specified and directed by the Engineer-in-Charge.
75Taking down carefully/aluminium point wiring (light, fan, socket or power point ) complete including fitting such as hylem sheet switches, ceiling rose, pendent holder sockets, regulator except concealed conduit and sunken boxes etc and making good distrubed surfaces of wall and floors etc to match with the existing, complete all as specified and directed by Engineer-in-charge.
76Providing and installing surface/concealed point wiring complete with 1.5 sq.mm nominal area PVC insulated and unsheathed multi-stranded copper conductor FRLSH cable, ISI marked, for one light point/fan point controlled by one switch, including 1.5 sq.mm single-core multi-stranded FRLSH copper earth wire connected to common earth and earth dolly, drawn through PVC rigid conduit of minimum 25 mm diameter, heavy grade, ISI marked, including M.S. sunken box of minimum 1.22 mm thickness and 60 mm depth, with base and top cover for mounting modular switches/sockets, including all necessary conduit accessories, fittings, connections, testing, labour, tools and making good, complete all as specified and as directed by the Engineer-in-Charge.
77All as per item No 76 here in before but for socket outlet 5 pin 5 Amp on same board with 1.5 Sqmm cable & including 1.5 sqmm single core multi stranded FRLSH copper earth wire to connected to common earth, with all necessary accessories and connections, complete in all respects, as specified and directed by the Engineer-in-Charge.
78All as per item No 76 here in before but for socket outlet 5 pin 5 Amp on independent board with 1.5 Sqmm cable & including 1.5 sqmm single core multi stranded FRLSH copper earth wire to connected to common earth, with all necessary accessories and connections, complete in all respects, as specified and directed by the Engineer-in-Charge.
79All as per ser item No 76 here-in-before but one 3/5 pin socket outlet 15 Amps with 2.5 Sq mm size on independent board all as specified and as directed by Engr-in-charge.
80Supplying and fixing 6 Amp, 250 Volt, one-way modular switch, one module, of approved make and type, suitable for mounting on standard modular switch box/plate, including fixing, connections, terminals, screws and all necessary accessories, complete all as specified and as directed by the Engineer-in-Charge.
81Supplying and fixing multipurpose modular socket outlet, 3/5-pin, 6 Amp, 250 Volt, two-module, of approved make and type, suitable for mounting on standard modular switch box/plate, including fixing, terminal connections, screws, mounting accessories and all necessary fittings, complete all as specified and as directed by the Engineer-in-Charge.
82Supplying and fixing 16 Amp, 250 Volt, one-way modular switch, one module, of approved make and type, suitable for mounting on standard modular switch box/plate, including fixing, terminal connections, screws, mounting accessories and all necessary fittings, complete all as specified and as directed by the Engineer-in-Charge.
83Supplying and fixing multipurpose modular socket outlet, 3/5-pin, 6 Amp, 250 Volt, two-module, of approved make and type, suitable for mounting on standard modular switch box/plate, including fixing, terminal connections, screws, mounting accessories and all necessary fittings, complete all as specified and as directed by the Engineer-in-Charge.
84upplying and fixing surface-type ceiling rose, polycarbonate insulated body, two/three-terminal type, suitable for 6 Amp, 250 Volt, complete with three terminals, of approved make and type, including fixing, terminal connections, screws and all necessary accessories, complete all as specified and as directed by the Engineer-in-Charge.
85Supplying and fixing modular fan regulator, stepped type, two-module, 120 Watt, of approved make and type, suitable for mounting on standard modular switch box/plate, including fixing, terminal connections, screws, mounting accessories and all necessary fittings, complete all as specified and as directed by the Engineer-in-Charge.
86Supplying and fixing PVC/polycarbonate lamp holder with back plate, suitable for batten fitting, complete with LED bulb of 9/10 Watt, B-22 cap type, minimum efficacy 100 lumens/Watt, of approved make and type, including fixing, terminal connections, screws, mounting accessories and all necessary fittings, complete all as specified and as directed by the Engineer-in-Charge.
87Supplying and fixing wall-mounted LED batten fitting, 1 × 20 Watt, 4 ft (approx. 1200 mm), 6000 K colour temperature, minimum luminous efficacy 100 lumens/Watt, inverter type with rechargeable emergency backup capable of providing continuous illumination for up to 4 hours, complete with decorative ultra-slim square-profile linear LED lighting fixture, extruded polycarbonate body/diffuser, energy-efficient and environmentally friendly construction, including LED module, electronic driver, rechargeable battery, inverter/charging unit, mounting arrangement, all light fittings, wiring, connections, accessories and testing, complete all as specified and as directed by the Engineer-in-Charge.
88Supplying and fixing 25 Watt, 230 Volt AC outdoor LED street light fitting, complete with high-pressure die-cast aluminium housing, heat-resistant construction, high-efficiency LED module, suitable LED driver, lamp mounting bracket, impact- and corrosion-resistant components, advanced thermal management with multiple optical arrangements, minimum IP 65/66 ingress protection, power factor greater than 0.95, minimum luminous efficacy 100 lumens/Watt, and CCT not less than 5700 K, including all necessary mounting accessories, wiring, connections, testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
89Taking down existing ceiling fan(s) carefully from their installed position, including disconnection of electrical wiring, removal of all necessary fixing accessories, lowering and handling without damage, transporting and depositing the fan(s) at the designated store/place of safe custody as directed by the Engineer-in-Charge, keeping the same properly protected during the period of wiring works, and thereafter taking out from safe custody, transporting back to the original location, re-fixing and reconnecting the ceiling fan(s), including all necessary minor materials, fittings, labour, tools and tackles, testing and making operational, complete all as specified and as directed by the Engineer-in-Charge.
90Providing and installing 12-way SPN (Single Pole and Neutral) Distribution Board, suitable for 240 Volt AC, IP-54 protected, fabricated from CRCA sheet steel of minimum 1.2 mm thickness, complete with double-door construction, powder-coated finish, suitable for mounting MCBs, 200 Amp rated copper busbar, insulated neutral link, separate earthing stud/earth link and all necessary internal supports, mounting arrangements, glands, terminals, hardware, accessories, connections and testing, complete all as specified and as directed by the Engineer-in-Charge.
91Supplying and fixing double-pole RCBO, 40–63 Amp, 100 mA residual current sensitivity, 230 Volt AC, 50 Hz, of approved make and type, including necessary attachments and accessories, suitable for mounting in the existing distribution board, including taking down and removing the existing old/unserviceable MCB, disposal/depositing as directed by the Engineer-in-Charge, making necessary connections, testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
92Supplying and fixing single-pole MCB, 5–32 Amp, suitable for 240 Volt AC, with short-circuit breaking capacity of 10 kA, of approved make and type, including taking down and removing the existing old/unserviceable single-pole MCB, necessary attachments and accessories, mounting, electrical connections, testing and commissioning, complete all as specified and as directed by the Engineer-in-Charge.
93Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/hard RM 230 23 standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 3.5 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & Gl pipe shall be measured and paid for separately)
94Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable , water supply pipe line etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in- charge.
95Returning filling in, approved soft/loose soil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in soft/loose soil complete all as specified and as directed by Engineer-in- charge.
96Removing excavated material(soil) n exc 50m and depositing where directedc at a level n exc 1.5 mtr above the starting point in soft/loose soil. complete all as specified and as directed by Engineer-in- charge.
97Providing material and labour for sand cushioning using dry and clean fine river sand for underground cable laying, including providing 8 cm thick sand cushion before laying of cable and 15 cm thick sand cover after laying of cable, compacted/punned to 18 cm thickness after laying of cable. The work shall include spreading, levelling and proper compaction of sand, complete in all respects as specified.Note: Punned/compacted thickness shall be considered for payment purpose.
98Providing material and labour for supply and laying of best quality, locally available sub-class ‘B’ burnt clay bricks (old size) for underground cable protection, laid flat and dry in trenches over the cable, perpendicular to the direction of cable, including proper alignment and placement of bricks/cable tiles, complete in all respects, as specified and directed by the Engineer-in-Charge.
99Providing material and labour for supply and fixing of 40 mm dia GI tubing, light grade, for cable protection, fixed along steel tubular poles/RCC poles, road crossings, culverts and laid in ground as required, including necessary clamps, nuts, bolts, washers and all other fittings and accessories, complete in all respects, as specified and directed by the Engineer-in-Charge.
100Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge.Note:- (i) Earth continuity of GI wire 4 mm including protection pipe upto 7.5 mtr from earth electrode will be included in unite rate.(ii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.(iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.(iv) Earthing resistence value is 5 or less than 5 Ohms.(v) The rate of earth work in any type of soil i.e excavation, returining filling and removal, form work is included in this item nothing shall be paid extra on this account. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57030402
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.67 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg. No T-1245, T-1246, T-1301, T-1302 And T-1307 Under Ge (North) Bathinda At Bathinda Mil Stn
Basic Detail
Tender No 8941/NIT-33/26-27/E8
Bidding Type Tender
Location
City Bathinda
State Punjab
Key Dates
Publish Date 21 Aug 2026
Submission Date 28 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 46.67 Lakhs
Tender Fee 500
EMD 93340
Exemption Available
Document List
b374fedc-828d-4dca-9c2f-8c505e83e2f8.html
BOQ_879116.xls
tenderdocuments33.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days