Coal and Mines Boards / Undertakings / PSU Closing in 1 days TDR #57021822

Tender For Sub: Annual Maintenance Contract For Day-To-Day Repair Andmaintenance Of 33 Kv, 6.6 Kv And 415 V Overhead Power Supplynetwork In Cws Complex, Jayant For A Period Of Two Years.Ncl/Cws/Enm/Tender/26-27/07 Dtd 09.08.2026

Issued by Boards / Undertakings / PSU · Singrauli, Madhya Pradesh
Tender Value
35.14 Lakhs
Estimated cost
Bid Submission
25 Aug 2026
1 days left
EMD
44000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Singrauli → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Sub: Annual Maintenance Contract For Day-To-Day Repair Andmaintenance Of 33 Kv, 6.6 Kv And 415 V Overhead Power Supplynetwork In Cws Complex, Jayant For A Period Of Two Years.Ncl/Cws/Enm/Tender/26-27/07 Dtd 09.08.2026

BOQ

Name of Work:- Sub: Annual Maintenance Contract for Day-to-Day Repair andMaintenance of 33 kV, 6.6 kV and 415 V Overhead Power SupplyNetwork in CWS Complex, Jayant for a Period of Two Years.NCL/CWS/ENM/Tender/26-27/07 dtd 09.08.2026
Sl. No. Item Description
1Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 Coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
2Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm X 60 cm), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) foundation including excavation and refilling etc. as required.
3Supplying and embedding 40 mm dia G.I. pipe (medium class) in pole collar/foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
4Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
5Dismantling of over head lines comprising of copper/aluminium over head conductor, G.I. wire cross arms, insulators etc. as required.
6Providing & Fabrication of 4 wire system, channel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for inslator pins etc (as per required) and painting with primer and finished paint as required.(Channel provided by dept.)
7Erection of cradle guard as required
8Suppling & Erection of G.I. wire No. 8 SWG including binding etc. as required
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) for grouting of pole.
10Supplying and fixing of 32 mm dia X 2.00 meters long G.I. pipe (medium class) bracket for mounting of wall fall/street light fitting on pole/wall including bending the pipe to the required shape 2 nos 40 mm X 3 mm flat iron clamps with nuts bolts and washer, painting the flat iron with primer and finish paint etc. as required.
11Supplying and erection of bow stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) foundation including excavation and refilling and also with 0.6 m long brace of size 50 mm X 50 mm X 6 mm angle iron with 50 mm dia pulley fixed at one end of the brace etc. as required.
12Supplying and erection of 100 mm X 80 mm pin insulator complete with G.I. spindle and nuts etc. as required.
13Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc as required.
14Supplying and erection of single piece nonlinear resister type lighting arrester suitable for 3 wire, 33KV overhead lines with rated voltage 30KV(rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arangement , G.I. bolts, washers etc. as required.
15Supplying and erection of 33 KV pin insulator complete with the large steel head G.I. bolts,nuts, washers etc. as required.
16Supplying and erection of a set of three 11 KV disc insulator for 33 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts,nuts, washers etc. as required.
17Fabrication & Erection of a set of cross bracing frame work for 33 KV overhead line double pole structure having four members fabricated out of 65 mm X 65 mm X 6 mm angle iron to form a rectangle of minimum size 2400 mm width X 2800 mm height complete with 50 mm X 6 mm M.S. flate iron clamps, bolts and nuts including drilling holes for insulater pins, bolts, nuts, washers etc and painting with primer and finish paint as required.(Angle Provided by Dept.)
18Fabrication & Erection of two lengths of channel iron 100 mm X 50 mm x 6 mm (9.56 Kg per meter) double pole cross arm for three wire 33 KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/fitting, bolts, nuts, washers etc and painting with primer and finish paint as required (Channel Provided by Dept.)
19Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and emoval of rubbish up to a distance of 50 m outside the periphery of the area cleared. Overhead line 33KV, 6.6KV,440Volt run from old 10MVA S/S Jaynt to CWS complex, Complex to Colony and other places as per instruction of Engineer In-charge (2 times, Pre and Post mansoon) (In and arround sub station and overhead line) and when required
20Erection of hexagonal type guard as required
21Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter and above including binding etc. as required.
22Fabrication of channel iron 100 mm X 50 mm x 6 mm (9.56 Kg per meter) pole top bracket/cross arm for single 33 KV over head line conductor complete with 50 mm X 6 mm M.S flat iron clamps, bolts and nuts including drilling holes for insulator pins/fitting, bolts, nuts, washers etc and painting with primer and finish paint as required
23Fabrication and fixing of channel iron 100 mm X 50 mm x 6 mm (9.56 Kg per meter) cross arm for two wire 33 KV over head line conductors complete with 50 mm X 50 mm X 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6 mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins/fittings, bolts, nuts, washers etc and painting with primer and finish paint as required (Channel provided by depart.)
24Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required (as per CPWD)
25Supplying and laying 25 X 25 mm G.I strip at 0.50 meter below ground as stip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolts & spring washer spaced at 50mm)
26Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required for horizantal run.
27Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as required for vertical run.
28Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggergate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required
29Required highly skilled manpower for HT/LT overhead line work and other work as and when required as per instruction of Engineer In-charge for explore the fault in electrical panels ,overhead line and rectify the same.(With all required tools, tackles and safety equipments etc.) (01 no Skilled & 01 no semi skilled)
30With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (For pole painting)
31Painting with aluminium paint of approved brand and manufacture to give an even shade . Two or more coats on new work (For pole painting)
32Supply and fixing of required size of M.S. Nut, Bolt and washer
33Transporting of tubulor pole from workshop yard to working site and submitting dismentled pole in store.
34Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57021822
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 35.14 Lakhs
LAST DATE 25-08-2026
Authority
Authority Name Northern Coalfields Limited
Work Description Tender for Sub: Annual Maintenance Contract For Day-To-Day Repair Andmaintenance Of 33 Kv, 6.6 Kv And 415 V Overhead Power Supplynetwork In Cws Complex, Jayant For A Period Of Two Years.Ncl/Cws/Enm/Tender/26-27/07 Dtd 09.08.2026
Basic Detail
Tender No NCL/CWS/ENM/Tender/26-27/07
Bidding Type Tender
Location
City Singrauli
State Madhya Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 25 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 35.14 Lakhs
Tender Fee Ref. Documents
EMD 44000
Exemption Not Available
Document List
9cc555ec-0e70-4e65-95cf-ba464bc991f4.html
AnnexureVI.pdf
BOQ_376708.xls
Tendernotice_1 (18).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

9cc555ec-0e70-4e65-95cf-ba464bc991f4.html

pdf

AnnexureVI.pdf

xls

BOQ_376708.xls

pdf

Tendernotice_1 (18).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders