Power Government Departments Closing in 9 days TDR #57021774

Tender For Tender For Repairing, Testing And Safe Delivery Of 3-Phase 50 Cycle Outdoor Type Oil Immersed Naturally Cooled, Stack Core Type Construction, Copper Wound Distribution Transformers (Type Conventional) Of Various Capacity 25 Nos. 25Kva, 15

Issued by Government Departments · Mandi, Himachal Pradesh
Tender Value
86.68 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
9 days left
EMD
86682
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mandi → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Tender For Repairing, Testing And Safe Delivery Of 3-Phase 50 Cycle Outdoor Type Oil Immersed Naturally Cooled, Stack Core Type Construction, Copper Wound Distribution Transformers (Type Conventional) Of Various Capacity 25 Nos. 25Kva, 15 Nos. 63 Kva & 10 Nos. 100 Kva 22/0.433 Kv In Various M&T Divisions Under Ceomz Mandi.

BOQ

Name of Work:- Tender for Repairing, Testing and Safe delivery of 3-Phase 50 cycle outdoor type oil immersed naturally cooled, stack core type construction, Copper wound Distribution Transformers (Type conventional) of various capacity 25 Nos. 25KVA, 15 Nos. 63 KVA & 10 Nos. 100 KVA 22/0.433 KV in various M&T Divisions under CEOMZ Mandi.
Sl. No. Item Description
1Repair of 22/0.433KV, 25 KVA Transformer contractors workshop including all material & T&P and guarantee up to Two (2) years complete in all respect.
2Dismantling and inspection of 25 KVA DTR at M&T workshop Yard (Copper Wound) including extraction of old transformer oil, dismantling of main tank cover, extraction of Core and winding. dismantling of HV&LV windings, bushings etc. inspection of core and re-assembling of core and Tank at M&T workshop Yard.(125% for qnty of DTR dismentaled)
3HT Leg Coils with DPC Wire/SE wire
4LT Leg Coils with DPC Strip
5Transformer Oil including filtration/ centrifuging.
6Other petty items such as gasket sheet, elephantite sheet, leatherized insulating paper, thinner, pure tin, srb tube, collon tape, craft paper, empire sleeves, washers etc
7Grey paint
8HT Bushings (3 nos.), complete including metal part
9LT Bushings (4 nos.), complete incuding metal part
10Oil Level Gauge complete
11Oil Drain Filter valve
12Air Release Plug
13Set of Bimetallic Connectors
14Plain Breather
15Labour Charges for repair and testing of 25 KVA DTR including Dismentalling of main tank cover , extraction and cleaning of core ,cleaning of DTR Tank , re-assembly of core , HV and LV coil winding ,assembly of complete core and winding ,leads , tank cover , bushing etc. Complete in all respect machinery and equipment carges all included
16Carriage charges of damaged /repaired 25 KVA DTR (2 X 120 KM) i.e to & fro distance X 25DTRS =19200)
17Loading and Unloading charges of damaged 25 KVA DTR through hydra/crane(loading at M&T workshop and unloading at Contractor's workshop and vice a versa after repair l.e. Loading at contractor's workshop and unloading al M&T workshop)
18Repair of 22/0.433KV,63 KVA Transformer at contractors workshop including all material & T&P and guarantee up to Two (2) years complete in all respect.
19Dismantling and inspection of 63KVA DTR at M&T workshop Yard (Copper Wound) including extraction of old transformer oil, dismantling of main tank cover, extraction of Core and winding. dismantling of HV&LV windings, bushings etc. inspection of core and re-assembling of core and Tank at M&T workshop Yard.(125% for qnty of DTR dismentaled)
20HT Leg Coils with DPC Wire/SE wire
21LT Leg Coils with DPC Strip
22Transformer Oil including filtration/ centrifuging.
23Other petty items such as gasket sheet, elephantite sheet, leatherized insulating paper, thinner, pure tin, srb tube, collon tape, craft paper, empire sleeves, washers etc
24Grey paint
25HT Bushings (3 nos.), complete including metal part
26LT Bushings (4 nos.), complete incuding metal part
27Oil Level Gauge complete
28Oil Drain Filter valve
29Air Release Plug
30Set of Bimetallic Connectors
31Plain Breather
32Labour Charges for repair and testing of 63 KVA DTR including Dismentalling of main tank cover , extraction and cleaning of core ,cleaning of DTR Tank , re-assembly of core , HV and LV coil winding ,assembly of complete core and winding ,leads , tank cover , bushing etc. Complete in all respect machinery and equipment carges all included
33Carriage charges of damaged /repaired 63 KVA DTR (2 X 120 KM) i.e to & fro distance X 15DTRS =3600)
34Loading and Unloading charges of damaged 63 KVA DTR through hydra/crane(loading at M&T workshop and unloading at Contractor's workshop and Trf 20 vice a versa after repair l.e. Loading at contractor's workshop and unloading al M&T workshop)
35Repair of 22/0.433KV, 100 KVA Transformer at contractors workshop including all material & T&P and guarantee up to Two (2) years complete in all respect.
36Dismantling and inspection of 100 KVA DTR at M&T workshop Yard (Copper Wound) including extraction of old transformer oil, dismantling of main tank cover, extraction of Core and winding. dismantling of HV&LV windings, bushings etc. inspection of core and re-assembling of core and Tank at M&T workshop Yard.(125% for qnty of DTR dismentaled)
37HT Leg Coils with DPC Wire/SE wire
38LT Leg Coils with DPC Strip
39Transformer Oil including filtration/ centrifuging.
40Other petty items such as gasket sheet, elephantite sheet, leatherized insulating paper, thinner, pure tin, srb tube, collon tape, craft paper, empire sleeves, washers etc
41Grey paint
42HT Bushings (3 nos.), complete including metal part
43LT Bushings (4 nos.), complete incuding metal part
44Oil Level Gauge complete
45Oil Drain Filter valve
46Air Release Plug
47Set of Bimetallic Connectors
48Plain Breather
49Labour Charges for repair and testing of 100 KVA DTR including Dismentalling of main tank cover , extraction and cleaning of core ,cleaning of DTR Tank , re-assembly of core , HV and LV coil winding ,assembly of complete core and winding ,leads , tank cover , bushing etc. Complete in all respect machinery and equipment carges all included
50Carriage charges of damaged /repaired 100 KVA DTR (2 X 120 KM) i.e to & fro distance X 10DTRS =2400)
51Loading and Unloading charges of damaged 100 KVA DTR through hydra/crane(loading at M&T workshop and unloading at Contractor's workshop and Trf 10 vice a versa after repair l.e. Loading at contractor's workshop and unloading al M&T workshop) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57021774
AUTHORITY Government Departments
TENDER VALUE 86.68 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Himachal Pradesh State Electricity Board
Work Description Tender for Tender For Repairing, Testing And Safe Delivery Of 3-Phase 50 Cycle Outdoor Type Oil Immersed Naturally Cooled, Stack Core Type Construction, Copper Wound Distribution Transformers (Type Conventional) Of Various Capacity 25 Nos. 25Kva, 15 Nos. 63 Kva & 10 Nos. 100 Kva 22/0.433 Kv In Various M&T Divisions Under Ceomz Mandi.
Basic Detail
Tender No HPSEBL/CEOMZ/MM/NIT-16/2026-27
Bidding Type Tender
Location
City Mandi
State Himachal Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 24 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 86.68 Lakhs
Tender Fee 1180
EMD 86682
Exemption Not Available
Document List
BOQ_209717.xls
e727187b-5d0e-4c76-9c5b-a2b571add145.html
GuidelineforERA.pdf
SBDNIT1622KV.rar
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_209717.xls

html

e727187b-5d0e-4c76-9c5b-a2b571add145.html

pdf

GuidelineforERA.pdf

rar

SBDNIT1622KV.rar

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders