Tender For Renovation/Replacement Of Street Lights And Allied Electrical Works At Model Town Staff Quarters
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Aug 2026
9 days left
EMD
21200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation/Replacement Of Street Lights And Allied Electrical Works At Model Town Staff Quarters
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of old damaged cable/wire and LED lights from the existing poles with the help of required tool & tackles along with provision of all the required safety equipments. and shifting to JE in charge store. |
| 2 | Supply of SMC junction boxes anti-corrosive, water resistant, UV protected, high temp resistant, weather able and suitable for all kinds of climatic conditions. |
| 3 | Supplying and fixing of MCB 6-amp rating, Single pole, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. DSR 2.10.1 Make: L&T/C&S/Siemens/DJB approved make. |
| 4 | Supply of 10 Sq. mm. X 3core PVC insulated and PVC sheathed /XLPE Aluminium Armoured cable. Make: Gloster/ Grandlay/Havells/DJB Approved. |
| 5 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 10 Sq mm size in the existing RCC/ HUME/ METAL pipe as required. |
| 6 | Supplying and drawing 2X1.5 sq.MM size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required, |
| 7 | Supplying and embedding 32 mm dia G.I. pipe (medium class) 7.5 Mtr in pole collar/foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 8 | Making Connection of 10 sq mm 3 core. Aluminium Armoured cable in the existing feeder Piller panel and in all the SMC junction boxes of the street light poles with required thimbling, tapping etc. with the help of crimping tool and other required tool & tackles along with provision of all the required safety equipments. |
| 9 | Demolishing cement concrete manually/ by mechanical means including disposal of material Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Painting work of street poles with one coat of red oxide primer and two coats of synthetic enamel silver paint, including kerosene oil, synthetic enamel reducer and also arrangement of all required safety equipment (i.e. expert labour, safety belts, ladders, safety helmets, safety shoes etc.) and other logistics required to carry out the painting work at SPS. (Note: Payment will be as per actual at site requirement). |
| 12 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B , Wire make: Gloster, Havells, Grandlay, DJB approved make |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 modular switch, connections ets as required. |
| 14 | Supplying and fixing 40A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required (DSR 1.25) |
| 16 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 17 | Supply of Higher Wattage Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack 25 W LED 6500 K Make :- Havells / Crompton / Orient / Philips/ Bajaj Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysAug 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender