Water Resources and Irrigation Government Departments Closing in 9 days TDR #57021663

Tender For Supplying Installation Testing And Commissioning Of The Various Capacity Dewatering Pumps, Dg Sets, Compact Substation And Automation Panels With Related E And M Works At Pump House Jagatpur Near Jagatpur Metro Station, New Delhi

Issued by Government Departments · Delhi, Delhi
Tender Value
2.14 Crore
Estimated cost
Bid Submission
24 Aug 2026
9 days left
EMD
4.28 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supplying Installation Testing And Commissioning Of The Various Capacity Dewatering Pumps, Dg Sets, Compact Substation And Automation Panels With Related E And M Works At Pump House Jagatpur Near Jagatpur Metro Station, New Delhi

BOQ

Name of Work:-
Sl. No. Item Description
1Supplying, installation, testing and commissioning of centrifugal non clog sewage storm water pump set having single suction with back pull out design with 250 mm x 300 mm suction and delivery sizes capable of delivering 1100 cum/hr at a head of 12 mtrs, semi open SS impellers suitable to handle solid min 100 mm dia, efficiency 80-81%, gland packed stuffing box complete with following technicalSpecification of motors:-(a) 55KW 75 HP, 1500 rpm total fan cooled squirrel cage induction horizontal electric motor IE3 efficiency enclosure confirming to protection IP 55 Horizontal Foot Mounted (B3), continuously rated (S1) suitable for operation on 415+/- 10% V,3 Phase ,50hz,+/-5%, AC Supply with ambient 50`C, Class F insulation with temperature rise to class B and altitude less than 1000M above MSL confirming to IS:12615/IEC60034.(b) M.S. Base frame made up of heacy duty C- Section girder as reqd. (Make:- KSB/Kirloskar/Groundfos/Sulzer/Wilo).
2Supply, installation, testing and commissioning of 52 BHP engine-driven centrifugal pump set, complete with suitable diesel engine, base frame, coupling, fuel tank, battery, exhaust system and control panel. The pump shall be capable of handling clear water with suction size 250 mm and delivery size 250 mm, designed to deliver a discharge of approx. 800 m³/hr against a total head of 10–12 metres. The set shall be robust, suitable for continuous duty, and complete with all necessary accessories such as suction strainer, delivery bends, nuts, bolts, vibration pads, and alignment. The installation shall include all required fittings, making the system fully operational at site as per specifications and directions of the Engineer-in-Charge etc as reqd.
3Supplying, installation, testing and commissioning of centrifugal non clog sewage storm water pump set having single suction with back pull out design with 250 mm x 250 mm suction and delivery sizes capable of delivering 850 cum/hr at a head of 11-12 mtrs, semi open SS impellers suitable to handle solid min 100 mm dia, efficiency 79-80%, gland packed stuffing box complete with following technicalspecification of motors:-(a) 37.5KW 50 HP ,1500 rpm total fan cooled squirrel cage induction horizontal electric motor IE3 Efficiency.Enclosureconfirming to protection IP 55 Horizontal Foot Mounted (B3),continuously rated (S1) suitable for operation on 415+/- 10% V,3 Phase ,50hz,+/-5%,AC Supply with ambient 50`C,Class F insulation with temperature rise to class B and altitude less than 1000M Above MSL confirming to IS:12615/IEC60034.(b) M.S. Base frame made up of heacy duty C- Section girder as reqd. (Make- KSB/Kirloskar/Groundfos/Sulzer/Wilo).
4Supplying, fabrication and installation of following sizes of MS pipes i/c cutting, welding, fixing in position in the sump/overhead at approx 3 mtr height/,installing in sump suction with special hoist, highly skilled riggers with safety belts as required (Cutting of road as & when required) . (Make Jindal/Tata/Sail/Surya Prakash)a) 300 mm dia 8.0 mm thick
5Supplying, fabrication and installation of following sizes of MS pipes i/c cutting, welding, fixing in position in the sump/overhead at approx 3 mtr height/,installing in sump suction with special hoist, highly skilled riggers with safety belts as required (Cutting of road as & when required) . (Make Jindal/Tata/Sail/Surya Prakash)b) 250 mm dia 8.0 mm thick
6Supplying, fixing and welding of following sizes of MS heavy duty flanges complete with water proof gasket, nuts bolts etc as required.A) 300 mm dia 28 mm thickness
7Supplying, fixing and welding of following sizes of MS heavy duty flanges complete with water proof gasket, nuts bolts etc as required.B) 250 mm dia 20 mm thickness
8Supplying, fixing and welding of following sizes of MS heavy duty flanges complete with water proof gasket, nuts bolts etc as required.C) 300 mm dia 30 mm thickness Blind Flange
9Supplying, fixing and welding of following sizes of MS heavy duty flanges complete with water proof gasket, nuts bolts etc as required.D) 250 mm dia 20 mm thickness Blind Flange
10Supplying, Fixing , welding of heavy duty Bends of Following sizes i/c anticorrosive painting etc as required 300 mm dia
11Supplying, Fixing , welding of heavy duty Bends of Following sizes i/c anticorrosive painting etc as required 250 mm dia
12Supplying and fixing of following sizes of NRV as per IS 5312 PN 1.6 in the Header line with the help of heavy duty hoisting machine i/c connections with nuts bolts / water proof gaskets i/c credit of old dismantled material etc as required. (Make Zoloto/Kirloskar/Sant/Kartar)a) 300 mm dia
13Supplying and fixing of following sizes of NRV as per IS 5312 PN 1.6 in the Header line with the help of heavy duty hoisting machine i/c connections with nuts bolts / water proof gaskets i/c credit of old dismantled material etc as required. (Make Zoloto/Kirloskar/Sant/Kartar)a) 250 mm dia
14Supplying and fixing of following sizes of Sluice Valve as per IS 5312 PN 1.6 in the Header line with the help of heavy duty hoisting machine i/c connections with nuts bolts / water proof gaskets i/c credit of old dismantled material etc as required. Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade direct on surface etc. complete as required. (Make Polycab/ Havells/KEI/ RR Kabels/Finolex)a) 300 mm dia
15Supplying and fixing of following sizes of Sluice Valve as per IS 5312 PN 1.6 in the Header line with the help of heavy duty hoisting machine i/c connections with nuts bolts / water proof gaskets i/c credit of old dismantled material etc as required. (Make Zoloto/Kirloskar/Sant/Kartar)b) 250 mm dia
16Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade direct on surface etc. complete as required. (Make Polycab/ Havells/KEI/ RR Kabels/Finolex)3.5 X 400 sq mm
17Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade direct on surface etc. complete as required. (Make Polycab/ Havells/KEI/ RR Kabels/Finolex)3.5 X 120 sq mm
18Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed Copper conductor armoured cable of 1.1 KV grade direct on surface etc. complete as required. (Make Polycab/ Havells/KEI/ RR Kabels/Finolex)4 x 50 sq mm
19Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.a) 450 mm width X 50 mm depth X 2.0 mm thickness (DSR 2025-4.1.6)
20Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as requireda) 450 mm width X 50 mm depth X 2.0 mm thickness (DSR 2025-4.2.6)
21Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :a) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources (DSR 2023 Civil Vol-I-4.1.1)
22Fabrication ,providing and fixing of Structural steel work for the pumps i.e Girder, chequred plates, Angle , Pipe etc and applying a priming coat of approved steel primer all complete testing and commissioning etc complete as required.
23Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. DSR E&M 2025 5.4
24Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. DSR E&M 2025 5.6
25Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR E&M 2025 5.15
26Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. DSR E&M 2025 5.14
27SITC of a compact substation comprising an 11 kV, 630 A, 21 kA for 3 seconds, three-way Ring Main Unit (RMU) incorporating two fixed, manually operated Load Break Switches (LBS) and one fixed, manually operated Vacuum Circuit Breaker (VCB) module, all housed in a factory-assembled, fully SF₆-insulated and stainless-steel sealed enclosure suitable for outdoor installation. The RMU shall be equipped with a series-trip, self-powered, microprocessor-based numerical relay providing comprehensive over-current (OC) and earth-fault (EF) protection with adjustable settings, LED indicators, event recording and protection coordination features. The scope includes supply, installation, testing and commissioning (SITC) of all associated cabling, terminations, earthing, control wiring, interlocks, pressure monitoring devices, mechanical safety features, nameplates, and all accessories required for reliable operation. The equipment shall conform to relevant IEC/IS standards and be installed complete in all respects as per site conditions and engineering requirements (TTA Approved) TRANSFORMER SECTION250 kVA, 11 kV/433 V, Dyn-11, copper-wound, cast-resin dry-type transformer designed for indoor installation, manufactured with high-grade copper windings and Class F/H insulation, complete with off-load tap links providing a tapping range of –5% to +5% in steps of 2.5% for voltage adjustment. The transformer shall be housed in a robust ventilated enclosure with temperature monitoring sensors, low-loss core construction, and adequate protection against moisture and dust. It shall conform to relevant IS/IEC standards, ensure low noise and high operational reliability, and be supplied with all necessary accessories, earthing, terminations, and fittings required for proper commissioning and satisfactory operation at siteLT Section Incomer630A 4P 50kA EDO ACB , 800/5A 15VA Acc. Cl: 1 Ring Type Current Transformer (Make AE), Multifunction Meter (LED display), 3Ph, Parameters: V, A, F, PF, kW, kVA, Old energy, On hours, site selectable kWh/ kVAh, CL: 1, Aux Sup: 90‐300V AC/DC, Size: 96X96 Red Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC-02 Nos Yellow Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V A-01 Nos Blue Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V A-01 Nos Green Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V A-01 Nos Amber Gen Next Pro LED Indicator 22.5 mm, Voltage: 240V AC-1 Nos 6A 1P 10kA, C-Curve MCB-04 NosMisc ItemsCUBICAL ILLU LAMP 240VAC, FLOURESCENT , TUBE , HOLDER 02-85 DEGREE CENTIGRADE THERMOSTATE DOOR LIMIT SWITCH 6A 1P 10kA, C‐Curve MCB NEUTRAL LINK 16A, DISCONNECTING TYPE TOGGLE SWITCH 6A FABRICATION DETAILSCSS Enclosure 16/14 Gauge GI Powder coated IP54 of size- 2200 x 3400 x 2200 mm Panel Enclosure 16/14 Gauge MS CRCA Powder coated 800Amp BUSBAR ‐ MAIN (Make L&T/Schnieder/ABB/Legrand/Crompton)
28Supply, installation, testing and commissioning of Feeder Pillar outdoor type compartmentalized of size 3.0 sqmtrs X 800 mm deep and fabricated from 2 mm thick CRCA sheet having necessary cable alleys, powder coated, 7 tank processed for prickling, degreasing including connection and interconnection as required as per specifications complete with following accessories . Suitable for 415 Volt, 3 Phase, 4 wire, 50Hz AC, having 1600 Amps capacity extensible type TPN Aluminum Alloy bus bars of high conductivity DMC/SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable section, entire panel shall have a common copper earth bar of suitable size at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sqmm PVC insulated copper conductor single core cable, cable alleys, cable gland plates in two half, i/c providing and fixing following switchgears etc. as per site requirement. (Make- Application Control Panel/ ASPL/ RP Control/ Precision/ Amit Power Control/Expert Engineers) I) Incoming a) 630 Ampere Four Pole 50kA Air Circuit Breaker EDO Type Thermal Magetic release with ajustable setting for overload and short circuit Protection & Spreader - 2 Nos. b) 3 Phase Digital Ammeter with inbuilt selector switch, Cl-1.0 - 2 Nos c) 3 Phase Digital Volt Meter with inbuilt selector switch, Cl-1.0 - 2 Nos. d) Resin Cast C.T's 400/5A, CL-1.0 15VA -6 Nos. e) C.T Shorting Link- - 8 Nos., f) R,Y,B Phase Indicating LED (230VAC)-2 Set, g) 32A Neutral Link -4 Nos.,h) 6A SP MCB 10KA -6 Nos Change Over Switch a) 630 A 4 pole on load Change Over Switch with ajustable setting for overload and short circuit Protection & Spreader + extended rotary handle - 1 No., b) 3 Phase Digital Ammeter with inbuilt selector switch, Cl-1.0 - 1 Nos, c) 3 Phase Digital Volt Meter with inbuilt selector switch, Cl-1.0 - 1 Nos ,d) Resin Cast C.T's 400/5A, CL-1.0 15VA -3 Nos., e) C.T Shorting Link- - 4 Nos., f) R,Y,B Phase Indicating LED (230VAC)-1 Set, g) 32A Neutral Link -2 Nos., h) 6A SP MCB 10KA -3 Nos II) Busbar TPN aluminum bus bars of minimum of 1200 A capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete, for cross section, size supports & their spacing etc. III) Outgoing (For 2nos 55 KW Star Delta Starter working + 2 nos 37.50 KW Star Delta Starter working ) Outgoings (55 KE 75 HP Star Delta Starter -2 Nos) a) 160 Ampere TP+N MCCB 50kA Thermal Magetic release with ajustable setting for overload and short circuit Protection & Spreader + extended rotary handle - 2 Nos. b) 4 Pole Power contactor 110 Amps -6 Nos. c) Thermal Overload relay (174-279 amp) -2nos d) Fan with Filter and MCB-2 nos ,e) ELCB for moisture sensor-2 nos ,f) Buzzer cum indicator LED--2 nos ,g) Indicating lights for various faults & tripping , h) Digital AMMETER with CTs & selector switch---2 sets ,i) Power supply 220v AC/ 24V DC1.5A---2 Nos ,j) Incorporating Heavy Duty overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter( To monitor SPCU power ON hours),RYB LEDindicator,Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection. -02 nos ., Low Level Indication Led-02 , Auto Manual rotatry Switch -02 Nos ,Auto Transformer-02 Nos., Lower & upper bearing temperature control.
29Supplying, Installing, Testing and Commissioning of Silent Type diesel generating set alongwith having prime power rating of 160 KVA, 415 Volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz., 3-Phase system and for 0.85 Load factor and as per latest (CPCB-IV+ compliant norms) and consisting of the followings : (Make Cummins/Sterling/Mahindra/Cotton Greaves/KOEL)Diesel Engine : Diesel Engine 4 Stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at NTP conditions and conforming to latest IS / BS Version covering BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted completed with all the required accessories.Engine mounted Instrument Panel fitted with and having digital display for following : Start-Sop switch with key.,Water temperature indication, Lubrication oil pressure indication., Lubrication oil temperature indication.,Battery charging indication., RPM indication., Over speed indication., Low Lub.oil trip indication., Engine Hourse indication. (Note:- Above indications may be incorporated multifunction units mounted on DG Set)Alternator : Synchronous, alternator rated at 160 KVA, 415 Volts at 1500 RPM, 3-Phase 50 Hz., AC Supply with 0.8 lagging power factor at NTP condition. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-H insulation.Base Frame & Foundation : Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendation of OEM, etc. as required at site (Including making of foundation as per OEM specification).Fuel Tank : Separate Daily Service Fuel tank of 990 liters capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications and accessories as required as per specifications.Exhaust System : Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor.Starting System : 12V/24V DC starting system comprising of starter motors: Voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 amp. Hour capacity lead acid type) as required as per specifications.Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, extraction, discharging hot air into the atmosphere as per specifications.
30Supplying and fixing of exhaust gas piping of suitable dia. for 250 KVA D.G. Set welded black MS, B (medium) Class pipe conforming to IS:1239 / MS pipe having wall thickness 6.35 mm conforming to IS: 3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with 50 mm thick mineral wool / Rockwool having density not less than 120 Kg / Cucm, wiremesh & cladding with 0.6 mm thick aluminum sheet etc. as required as per specifications.
31STRUCTURE FOR EXHAUST PIPING: Providing & fixing for MS support structure including civil foundation for exhaust fume pipes of DG Sets (Exhaust pipe to be measured and paid for separately) along horizontal and vertical runs and monkey ladder upto the height (as per CPCB norms) including cutting, welding etc and applying two coats of red oxide and two coats of synthetic enameled paint of colour and shade as directed by AAI. The design of the support structure shall be done by the contractor and shall be as per CPCB norms. Design and drawings shall be got vetted from IIT / REC before execution as per specifications as required.
32Supplying, installation, testing & commissioning of 200 watt Flood light LED fittings having 22000-23000 system lumens output & system efficacy≥110 lumens/watt, IP66 protected, body made out of pressure die cast aluminium for better thermal management, power factor≥0.95, THD≤10%, CRI≥70% & CCT 3000-6500 ⁰K i/c making connection etc complete as per specification as required. i/c dismantling along with credit for worn out luminaries under buy back arrangement & connection etc as reqd.(Make Wipro/Philips/LT/Regent/ Havells) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57021663
AUTHORITY Government Departments
TENDER VALUE 2.14 Crore
LAST DATE 24-08-2026
Authority
Authority Name Irrigation And Flood Control Department
Work Description Tender for Supplying Installation Testing And Commissioning Of The Various Capacity Dewatering Pumps, Dg Sets, Compact Substation And Automation Panels With Related E And M Works At Pump House Jagatpur Near Jagatpur Metro Station, New Delhi
Basic Detail
Tender No EE/MD-I/13/2026-27/
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 14 Aug 2026
Submission Date 24 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 2.14 Crore
Tender Fee Ref. Documents
EMD 4.28 Lakhs
Exemption Not Available
Document List
01cd335a-29a4-4477-b120-c9222dbe9ef0.html
BOQ_395622.xls
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

01cd335a-29a4-4477-b120-c9222dbe9ef0.html

xls

BOQ_395622.xls

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders