Tender For Addition And Alteration To 03 Watch Towers At Naval Air Enclave Porbandar Under Ge Navy Porbandar
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Aug 2026
12 days left
EMD
77500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Porbandar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition And Alteration To 03 Watch Towers At Naval Air Enclave Porbandar Under Ge Navy Porbandar
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of concrete of any description and any position not othrewise specifically provided as per site requirement as direction . |
| 2 | M&L for CRS TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips |
| 3 | All as per item No.02 above but 6mm to 8mm dia bars |
| 4 | M&L for formwork to column & beams &edge of concrete flates break in floors of landings and similar work with fair finished surfaces and complete |
| 5 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick with fair finished surfaces |
| 6 | M&L for RCC M30 design mix for column , pillars , basement walls, ballast walls and the like any thickness above top of footings: including attached pilasters and buttresses |
| 7 | M&L RCC M-30 design mix for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs and in shelves and the like |
| 8 | M&L for porbandar stone masonry work built in cement mortar 1:6 complete all as specifieid. |
| 9 | M & L for rendering 15 (10+5)mm thick C:M 1:4 on stone masonry surfaces finished even & smooth without using extra cement |
| 10 | M & L for ceiling rendering 5mm thick C:M 1:6 on concrete surfaces finished even & smooth without using extra cement |
| 11 | M & L for internal rendering 12mm thick C:M 1:6 on stone masonry surfaces finished even & smooth without using extra cement |
| 12 | M & L for hardcore of gauge n exc 63 deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface |
| 13 | M&L PCC 100 mm thick 1:2:4 type B-2 using 40 mm graded stone aggregare finished even and smooth without using extra cement layed alternative bays. |
| 14 | S & F Fe 410W(Gde-E-250 ) for stee stairs framed work incl stringers treads, landing balusters hand rails etc incl cleats brackets etc tubular & sqr , rectagular sec including special shaped washer etc, coplete using ERW or induction butt welded tubes conforming to ISI 1161-1998 grade st-240. |
| 15 | S&F machine cut Kota stone slabe flooring 20 thick set and jointed in neat cement slurry and pointed incl rubbing &polishing white or colour cement to match as complete. |
| 16 | M&L for painting two coat of epoxy paint over a coat of epoxy primer on steel surfaces of any description, n.exc. 10cm in width or girth when unconnected with other painting including removing of existing painting by burning off by blow lamps and cleaning with scrapers including preparation of surfaces, complete all as directed by Engr-in-charge.(Note :- EPLUX 610 HBLD primer coating and two coats of EPILUX 155 High build Enamel finishing coat of Berger protection coating or equivalent in Asian Paints/Dulux Paints). |
| 17 | M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed |
| 18 | M&L for powder coated anodised aluminium frame for door, window , ventilation more rebate sincl joint cleat for fix as complete all as specified and directed |
| 19 | S&F 2nd class hard wood plain solid straight chowkat framed rebate on the solid complete all as specified and directed |
| 20 | S&F factory made 30 mm 2nd class hard wood glaged and skelton shutters doors chamfered and round fitted with cuttsolid straightand fitted to chowkat framed rebate on the solid as direction . |
| 21 | M&L for powder coated anodised aluminum window ,ventilation shutters aluminium sec wt 0.55 kg /rm incl fitings &beading complete all as specified and directed |
| 22 | M&L for providing and applying of silicon sealent in construction joint and required place tomake joint water tights complete all as spd. |
| 23 | M&L for anodised aluminium grill with approved design &pattern incl std sec and fixed to window frame with stainlees screw @200 mm dis as direction . |
| 24 | M&L for 4.8 mm thick sheet glass ordinary quality pin headeed type &glazing with alu beading with rubber neoprene packing in sqr exc 1.0t 2.0 as complete. |
| 25 | M&L for Preparation of new plastered surfaces in walls soffits, facia roof and applying Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. at any height including necessary scaffolding etc complete all as specified and as directed by Engr-in-Charge of weather coat primer all as specified. |
| 26 | M&L for 10 thick plaster (avg ) on concrete surface in cement morter 1:4 in order tomaintain slope finished even and smooth all as specified and directed |
| 27 | M&L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing.Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions.(ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. |
| 28 | Taking down old point wiring complete for (light, fan, socket 5/15 amps, bell point etc) complete with all light fittings accessories , such as switches,sockets 5/15 Amps, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of walls, floors, etc all as speified and directed by Engineer -In-Charge. |
| 29 | M& L for point wiring with PVC insulated unsheathed stranded copper conductor cable FRLSH of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width/in concealed conduit non metallic , rigid PVC conduit of adequated size with all fittings and conduit accessories including suiitable size modular metal flush box and modular white cover plate with frame for housing the switches,socket outlets ,including all necessary wall cutting and making good disturbed surface all as directed and specified. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. |
| 30 | (a) One light point controlled by one, one way switch |
| 31 | (b) One ceiling /exhaust fan point controlled by one switch and regulator |
| 32 | (c) One security light point controlled by one switch |
| 33 | All as per item no 29 above but wire 2.5 sqmm One 3 pin 5 amp socket out point on the independent board |
| 34 | All as per item no 29 above but wire 2.5 sqmm One 3 pin 5 amps socket out let point on same board with other switches. |
| 35 | All as per same in item No 29 above but for one socket outlet 15 amp on independent board with 4.0 Sq. mm cable and 4.0 Sq.mm. earth wire. |
| 36 | S & F Modular switch 1 way 6A, 1 module all as specified and directed by EIC. |
| 37 | S & F Ceiling rose, surface bakelite 65x50 mm three terminal |
| 38 | S & F modular socket, Socket, 6A - 2/3 pin combined 2 module all as specified and directed by EIC. |
| 39 | S & F Modular switch 1 way 16A, 1 module all as specified and directed by EIC. |
| 40 | S & F modular socket 16A - 2/3 pin combined 2 module, all as specified and directed by EIC. |
| 41 | S & F Modular fan regulator 120 Watt, 2- module , AC 240 Volts complete. |
| 42 | Supply and fix ceiling fan 1200 mm sweep 230 V AC, 5 Star rated with brushless direct current motor (BLDC) complete including connecting up with 3 core cord flexible from ceiling rose to fan etc all as specified and directed by Engr-in-charge. |
| 43 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, oltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed |
| 44 | Supply and fixing in replacement LED light fitting 1x 20 Watt,220 V AC decorative box type with driver , holder including LED tube light connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. |
| 45 | S & F in replacement LED tube light fittings mirror type with high output diffuser 2 feet ,1x10 Watt ,220V, Indoor decorative LED Engineering Plastic batten with opal diffuser, IP 20 and with System Efficacy of 100lm/W, holder including LED Tube light connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rose complete all as directed by Engr-In-Charge. |
| 46 | Supply and fixing in replacement LED street light fitting 35 Watt,230 V AC outdoor type with high pressure die aluminium housing and heat resistant complete with driver , lamp, with impact and corrosion resistanct including thermal management in multiple optics, including suitable size mounting bracket , clamps ,nut,bolts complete with IP 65/66 protection all as specified and directed by Engr-in-Charge. |
| 47 | Supply and fixing in replacement LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp & connecting up with flexible copper conductor cable with suItable size complete all as directed by Engr-In-Charge. |
| 48 | Supply and fixing in repair/replacement SEARCH LIGHT WITH STAND ARRANGEMENT revolving full around 360 Degree & its vertical axis with 15 degree up and down from the horizantal plane using UNDER DECK CONTROL ARRANGEMENT (UDCA), complete lighting based on fully LRF Model made of 3mm low Carbon Aluminium alloy with die-cast back housing, The main reflector is in glass with SS side refelector, 4 mm thick toughened front glass with endless neoprene rubber gasket, focusing arrangement for adjustment of light-beam narrow or spread option , E-40 lamp hplder, painted by powder coated paint & finished with special polyurethane weather proof coating for corrosion resistant, seperate control gear/panel suitable fpr HPSV OR MH lamp of 250 W complete all as specified and directed. Model ITEM Code :- (Kalin Engineering Works-RSL-LRF25G40) / or any other equivalent Make. |
| 49 | M&L in replacement for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC Conduit of suitable dia medium Grade concealed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 6 sqmm and one wire of 6.0 sqmm and one run of PVC casing caping/Conduit shall be measured as one unit. |
| 50 | S & F in replacement MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 6 way Double door |
| 51 | S & F in replacement MCB TPN 63 Amps , 415Volts, 16 KA complete all as specified and as directed. |
| 52 | S & F in replacement MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail ,240Volts SPN with 12 way Double door , IP-43-IK09 protection |
| 53 | S & F in replacement MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 to 63Amps |
| 54 | S & F in replacement MCB SP 6-32 Amps 'C' Series complete all as specified and directed. |
| 55 | S& F in replacement XLPE insulated armoured and pvc sheated heavy duty electric cable size 3.5 core ,35 Sqmm cross sectional area with aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts / saddle on wall with clamps including testing complete note- rate is inclusive of cable gland & cable lugs |
| 56 | S& F in replacement of laying of Double Walled Corrugated (DWC) HDPE pipe of following size 40/32 mm outer/inner dia of conforming to IS 16205 Part -24 including necessary bends,coupling ,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge |
| 57 | M&L in replacement earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender