Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #57021647

Tender For Repair / Maintenance Of Earthing, Lightening Protection System, Flameproof Fittings, Electric Siren And Allied Electrical Works In Tp And Non Tp Areas At installation Kalinga, installation Karna And Mes Complex, Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
20.50 Lakhs
Estimated cost
Bid Submission
04 Sep 2026
12 days left
EMD
41000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Earthing, Lightening Protection System, Flameproof Fittings, Electric Siren And Allied Electrical Works In Tp And Non Tp Areas At installation Kalinga, installation Karna And Mes Complex, Visakhapatnam

BOQ

Name of Work:- Repair / Maintenance of Earthing, Lightening Protection System, Flameproof Fittings, Electric Siren and Allied Electrical Works in TP and Non TP Areas at INS Kalinga, INS Karna and MES Complex, Visakhapatnam
Sl. No. Item Description
1Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
2M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including Medium Grade Stove Enamelled ERW MS Conduit, ISI Marked, 20 mm dia including all accessories surface type / semi concealed type including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for Flame Proof Application of One Light / Fan Point controlled by One Switch complete all as specified and as directed.
3All as per Serial Item No. 2 above but One 3 Pin Switch Socket Outlet 16 Amps on Independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
4S & F Flame Proof Switch, Rotary Type with Termination Box in LM6, 16 Amps, Single Pole, 250 Volts including Rubber Gasket as per IS – 2149, ISI marked for ON/OFF Light, CMRI certified with cable entries complete all as specified and as directed.
5Taking down existing serviceable Flame Proof Switch, Rotary Type with Termination Box in LM6, 16 Amps, Single Pole, 250 Volts and Refixing in new or existing location after repairs to point wiring complete all as specified and as directed.
6S & F Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 250 Volts, 2P+Earth complete all as specified and as directed.
7Taking down existing serviceable Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 250 Volts, 2P+Earth and Refixing in new or existing location after repairs to point wiring complete all as specified and as directed.
8S & F in repairs Flame Proof Junction Boxes 2 / 3 / 4 Way suitable for 20 mm dia ERW Steel Conduit complete all as specified and as directed.
9S & F in repairs Flame Proof, LED Light Fitting 2 X 16 Watt, CMRI certified recommended for Gas / Vapor Group of IIA & IIIB, Zone 1 & 2 and IP 65 Protection with Die Cast Aluminium Housing with Heat Resistant Toughened Glass with LED Tube Light Fixtures, Driver, Holders, Connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
10S & F in repairs Flame Proof / Whether Proof Well Glass LED Light Fitting suitable for 60 Watt LED as per IS – 13947, body made out of Aluminium Alloy LM-6 Epoxy Painted with Guard, Reflector, Flameproof Clear Glass complete all accessories prewired CIMFR certified Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
11S & F in repairs Next Generation, Energy Saving, Environment Friendly & Robust Highbay LED Luminaire, Round type, suitable for Ceiling [Surface/Suspended] mounting, of not less than 12000 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver and fixed with suitable Clamps made out of MS, bolts, nuts, washers and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95. Make: Model / Catalogue No. SAUCERGENXMIDHBP120WLED857PWBBOLTG of Havells or its Equivalent Model in Philips / Crompton Greaves / Wipro / GE / Bajaj / Jaquar
12Taking down unserviceable 40 / 20 / 10 Watt Flame Proof / Whether Proof Tube Light Fittings and carrying out repairs as required and replacement of old unserviceable Spares with New Spares, re-assembling and re-fixing in existing position and connecting up with three core flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
13Supply Only 18/20 W LED Master Tube Rod complete all as specified and as directed.
14Supply Only LED Lamp 40 Watt complete all as specified and as directed.
15Supply Only LED Lamp 22 / 24 Watt complete all as specified and as directed.
16Supply Only Holder suitable for FLP Well Glass complete all as specified and as directed.
17S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified.
18S & F MCB, FP, 40 to 63 Amps, 10 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
19S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
20S & F MCB, DP, 40 to 63 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
21M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
22M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
23M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
24M & L for Sub main wiring with 2 runs of single core 1.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 1.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
25S & F Flame Proof Switch Socket & Plug Combined in LM6 Cable Termination Box in LM6, 16 Amps, 440 Volts, 3P+Earth complete all as specified and as directed.
26M & L for Testing of Earth Resistance of existing Earth Pit as directed by the Engineer-in-Charge as and when required using Earth Resistance Testing Equipment and producing the Test Results and maintaining suitable records complete all as specified and as directed. Note: The contractor shall be asked to carry out the Earth Test as and when required basis as per the site / user requirement. Testing of each Earth Pit shall be measured as one unit. All test results shall be entered in a suitable Register and shall be submitted to the Engineer-in-Charge. The rate quoted is deemed to be inclusive of provision of all necessary Testing Equipment as and when required basis. Nothing shall be paid extra on this account.
27M & L for Replacement of Broken RCC Cover by new 50 mm thick Precast RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways and suitable Handle made of 10 mm dia Round Bar and other allied works complete all as specified and as directed.
28Taking down Earth Strip from Earth Pit and testing of resistance of existing Earth Pit of Lightening Conductor for its continuity by Highly Skilled Electrician / Technician using Digital Earth Resistance Tester including checking the healthiness of earthing system and replacing Nut, Bolt with Brass Nut, Bolts as per required size and providing all Tools and Testing Apparatus including rectification of the Discontinuity by providing new Lightening Conductor or refixing the displaced existing Lightening Conductor in place as required including necessary minor repair work as required during rectification complete all as specified and as directed. Note: Testing of each Earth Pit shall be measured as One Unit and shall be carried out on priority as and when required basis. The Test Results shall be submitted to the Engineer-in-Charge and User duly signed by all concerned before claiming payment. All the materials required to complete the work at site such as wooden Plugs, Nut, Bolt, Washers, Saddles, fixing Screws etc. shall be provided by the contractor at No extra cost to the Government. Water and Salt as required in the Earth Pit shall be provided by the contractor. The rate quoted is deemed to be inclusive of provision of all necessary Testing Equipment as and when required basis and all the consumables as specified hereinabove. Nothing shall be paid extra on this account. Air Terminal, GI / Aluminium Strip shall be measured and paid separately.
29Taking out and Re-fixing of Old Serviceable Tilted Air Termination Rod of any size and type after Straightening & Dressing with and including suitable Nut, Bolts and Washers to Earth Strip complete all as specified and as directed.
30S & F in repairs Earth Continuity Conductor or Main Earthing Lead made of Copper Strip of size 20 X 3.15mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
31S & F in repairs Earth Continuity Conductor or Main Earthing Lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
32Taking down old Copper / GI / Aluminium Strip of any size and any type from Building / Hangar [Roof / Down Conductor] / Pipe / Trench and Re-fixing the serviceable Copper / GI / Aluminium Strip of any size and type after Straightening & Dressing with and including Saddles / Insulators with Screws for fixing and making good disturbed surfaces complete all as specified and directed.
33S & F in repairs Aluminium Strip of size 25 X 3 mm, fixed to walls / columns / beams etc. with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
34S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
35M & L for Earthing complete with CI Earth Pipe Electrode with Flanged ends, Centrifugally Cast, Class \\"A'', Heavy Duty, 80 mm dia all as per IS – 1536 of 2.50m length burried directly and preferably vertically in ground with top edge of the Pipe not less than 2.00 metres below Natural Ground Level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Pipe Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, Drilling 400mm dia Bore Hole in any type of strata by suitable means for lowering the CI Pipe, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
36M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
37M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4mm GI Wire [Earth Lead] and GI Pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
38S & F in repairs Switch Socket Outlet, 3 & 2 Pin, Multipurpose, 6 Amps, 230 Volts, Flush Type complete all as specified and as directed.
39S & F in repairs Switch Socket Outlet, Multipurpose, 3 pin, 16 Amps and 3 pin, 6 Amps, Flush Type, 230 Volts controlled by One Switch complete all as specified and as directed.
40S & F in repairs Electronic Fan Regulator, Stepped Type, Flush Type, AC, 230 Volts, Single Pole complete all as specified and as directed.
41S & F in repairs Surface & wall mounted Energy efficient T8 LED Tube Light Fitting, of not less than 2000 Lumens output, 5700K of Cool White, including T8 LED Tube with extruded Aluminium housing and robust construction with necessary acrylic diffuser & Integrated Electronic Driver, all accessories internally prewired complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
42S & F Lamp Holder, Insulated Body with Back Plate, 230 Volts for Batten Fittings complete all as specified and as directed.
43S & F in repairs Factory made FRP Junction Box of size 155 X 210 X 92mm with IP 66 Protection and including MCB, SP, 16 Amps, C Curve, 240 Volts [1 Nos] and one number heavy duty Four Way Connector for incomer and outgoing cable, suitable for Pole mounting and fixed with clamps made out of 40 X 3mm flat iron with suitable nuts, bolts, gland lugs etc. duly painted with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
44S & F in repairs Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
45S & F in repairs Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
46S & F in repairs Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
47S & F in repairs Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
48S & F in repairs Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. of 3 Modules size, White Colour as per existing Make / Model complete all as specified and as directed.
49Taking down / Dismantling the Electrical Connection from Rolling Shutter with Gearbox Motor of Capacity 1.0 HP, Electrically operated, 3 Phase, 415 Volts, removing Induction Motor and Gearbox for Reconditioning / Overhauling completely, Transporting the Induction Motor Workshop and strip opening the motor and removing the burnt out winding and cleaning the Starter Core and Rewinding with Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., and replacement of unserviceable Ball Bearing and assembling back the Motor and re-fixing with Gearbox and necessary Electrical Connections, including replacement Base Frame with New Base Frame as per existing of Induction Motor and Gearbox Assembly, fixing with suitable Nuts, Bolts, Washers, necessary Welding / Brazing with Shutter frame with necessary alignment with Main Shaft, Speed Reducing Gearbox Assembly and Greasing, servicing and filling of New Gear Oil for smooth functioning of the system complete and testing and commissioning the Rolling Shutter complete all as specified and as directed.
50Taking down / Dismantling the Electrical Connection from Electric Siren Motor of Capacity 1.0 HP, Electrically operated, 3 Phase, 415 Volts, removing Induction Motor for Reconditioning / Overhauling completely, Transporting the Induction Motor Workshop and strip opening the motor and removing the burnt out winding and cleaning the Starter Core and Rewinding with Super Enamelled Copper Conductor of suitable Gauge including Insulation, Varnishing, Packing and Testing etc., and replacement of unserviceable Ball Bearing and assembling back the Motor and re-fixing and necessary Electrical Connections, including replacement Base Frame with New Base Frame as per existing of Induction Motor Assembly, fixing with suitable Nuts, Bolts, Washers, necessary Welding / Brazing with Shutter frame with necessary alignment and servicing for smooth functioning of the system complete and testing and commissioning the Electric Siren complete all as specified and as directed.
51M &L for checking the serviceability including loose contact and condition of cable terminations of all the existing MCB MCCB DBs / Flame Proof DBs at any building/any place once in three months and opening a DB serviceability register and recording building wise including obtaining users signature in the register complete all as specified and as directed. Note: The checking shall be carried out in presence of user. One time checking including entering in the register is considered as one job.
52S & F Energy efficient LED Flood Light fitting, of not less than 12000 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP66 Protection and Surge Protection device of 10 KV, Heat resistant Toughened Glass Cover, high power LEDs as light source, electronic driver and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95. System efficacy ≥ 110/125LPW 10KV SPD included. Make: Model / Catalogue No. JETAIRISFL120WLED757APWBLTG of Havells or its Equivalent Model in Philips / Crompton Greaves / Wipro / GE / Bajaj / Jaquar Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57021647
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20.50 Lakhs
LAST DATE 04-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Earthing, Lightening Protection System, Flameproof Fittings, Electric Siren And Allied Electrical Works In Tp And Non Tp Areas At installation Kalinga, installation Karna And Mes Complex, Visakhapatnam
Basic Detail
Tender No 8295 / E8
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 04 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 20.50 Lakhs
Tender Fee 500
EMD 41000
Exemption Available
Document List
8295Tender.pdf
BOQ_879102.xls
e3351366-3199-4ab0-af40-1301c4b9372f.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

8295Tender.pdf

xls

BOQ_879102.xls

html

e3351366-3199-4ab0-af40-1301c4b9372f.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender