Tender for Construction Of Research Wing & Administrative Building At Rrtts, Bhubaneswar (Composite)

BOQ

Name of Work:- Construction of Research Wing & Administrative Building at RRTTS, Bhubaneswar (Composite)
Sl. No. Item Description
1CIVIL WORKS
2Clearing & Grubbing the road landincluding uprooting rank vegetation grass bushes shrubs etc complete.
3Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge (per 100 Cum.)
4Ground Floor
5Office Building
6Boundary wall with gate
7Utility Building
8Filling in foundation and plinth with excavated materials moorum including watering and ramming as directed by the Engineer-in-charge of earth work etc. (per 100 Cum.)
9Ground Floor
10Office Building
11Boundary wall with gate
12Utility Building
13Filling Foundation and Plinth with sand watered and rammed etc as pe the direction of the Engineer-in charge.
14Ground Floor
15Office Building
16Boundary wall with gate
17Utility Building
18Providing & applying of pre constructional anti-termite treatment by drilling 12 mm dia holes at distance of 30 cm @ junction of wall & floor about 300 mm apart deep enough to reach the soil below chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5 SC OF BAYER MAKE mixed with 47.5 ltr water) pumped these holes to soak the soil @ 1ltr solution of each holes as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour, conveyance, T&P, all taxes and hire charges of machinaries as per direction of Engineer-in-charge.
19Ground Floor
20Office Building
21Utility Building
22Cement concrete (1:3:6) with 40 mm size hard granite metal (per Cum)
23Ground Floor
24Office Building
25Boundary wall with gate
26Utility Building
27Cement concrete (1:2:4) with 12 mm size hard granite chips (per Cum)
28Ground Floor
29Office Building
30Boundary wall with gate
31Utility Building
32First floor
33Office Building
34Second Floor
35Office Building
36Terrace floor
37Office Building
38Brick work with Fly Ash bricks in C.M(1:6) in Foundation & Plinth (per one Cum)
39Ground Floor
40Office Building
41Boundary wall with gate
42Utility Building
43Brick work with Fly Ash bricks in C.M(1:6) in Super-Structure (per one Cum)
44Ground Floor
45Office Building
46Boundary wall with gate
47Utility Building
48First floor
49Office Building
50Second Floor
51Office Building
52Terrace floor
53Office Building
54Fly Ash Brick work with K.B.bricks in C.M(1:4) in Super-structure (per one Cum)
55Ground Floor
56Office Building
57Utility Building
58First Floor
59Office Building
60Second Floor
61Office Building
62Full ht. Solid Partition with both side Veneer finish with Melamine Polish:- providing and fitting of Anti-termite full height double skin solid partition 9222, 100mm thk up to false ceiling level or as per drawing/design made out of 63.5mmx38.1mmx2.5 mm anodised aluminium hollow vertical and horizontal sections to be placed @ maximum 1000mm c/c (or any additional member wherever required to be provided and every alternate vertical sections are to be fixed to the true ceiling) and providing necessary cutouts to run the cables inside the partitions both horizontally and vertically and both side covered with 12mm thk Fire Retardant ply (conforming to IS code :5509) and finished with 4.0mm thk Veneer (Greenply Woodcrest or equivalent) and melamine polish of approved shade and colour with approved adhesive (No screws should be visible) as per design/drawing or as directed by the Architect/Engineer-in-Charge. The rate includes all complete with materials, labour, T&P, taxes etc. (Make: Sylvan Premium Club, Green Ply Club, Century Architect)
63Ground Floor
64Office Building
65Reinforced Cement concrete work of M-20 grade concrete with 20 mm down graded crusher broken hard granite chips (per Cum) .
66Foundation
67Boundary wall with gate
68Utility Building
69Grade Beam
70Boundary wall with gate
71Utility Building
72Tie Beam
73Boundary wall with gate
74Plinth Band
75Utility Building
76Column Foundation lv to GL
77Boundary wall with gate
78Column (Super-Structure)
79Boundary wall with gate
80Utility Building
81Roof Beam
82Boundary wall with gate
83Utility Building
84Roof Slab
85Boundary wall with gate
86Utility Building
87Lintel
88Boundary wall with gate
89Utility Building
90Chajja
91Boundary wall with gate
92Utility Building
93Reinforced Cement concrete work of M-25 grade concrete with 20 mm down graded crusher broken hard granite chips (per Cum) .
94Office Building
95Ground Floor
96Foundation
97Grade Beam
98R.C.C Wall
99R.C.C Column
100Ground Floor
101Firsrt Floor
102Second Floor
103Terrace Floor
104Roof Beam
105Ground Floor
106Firsrt Floor
107Second Floor
108Terrace Floor
109Roof Slab
110Ground Floor
111Firsrt Floor
112Second Floor
113Terrace Floor
114Roof Slab (Double Stage)
115Firsrt Floor
116Lintel
117Ground Floor
118Firsrt Floor
119Second Floor
120Chajja
121Ground Floor
122Firsrt Floor
123Second Floor
124Staircase
125Ground Floor
126Firsrt Floor
127Second Floor
128Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification.
129Ground Floor
130Office Building
131Boundary wall with gate
132Utility Building
133First Floor
134Office Building
135Second Floor
136Office Building
137Terrace Floor
138Office Building
13912mm thick Cement plaster (1:4) over brickwork with neat Cement punning for skirting including curing etc. complete.
140Ground Floor
141Office Building
142Utility Building
143Boundary wall with gate
14412 mm thick Cement Plaster(1:6) for brick work (per one Sq. Mtr.)
145Ground Floor
146Office Building
147Boundary wall with gate
148Utility Building
149First Floor
150Office Building
151Second Floor
152Office Building
153Terrace Floor
154Office Building
15516 mm thick Cement Plaster(1:6) for brick work or stone masonry (per one Sq. Mtr.)
156Ground Floor
157Office Building
158Boundary wall with gate
159Utility Building
160First Floor
161Office Building
162Second Floor
163Office Building
1646 mm thick Cement Plaster(1:4) to RCC surface finished smooth including closed deep chipping & slurry treatment (per one Sq. Mtr.)
165Ground Floor
166Office Building
167Boundary wall with gate
168Utility Building
169First Floor
170Office Building
171Second Floor
172Office Building
173Supply of MCM Modified Clay Material - MCM Slate Stone Radish brown - 1200 x 600 mm , thickness 2.5mm to 3mm PHOMI make, as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.
174Ground Floor
175Office Building
176First Floor
177Office Building
178Second Floor
179Office Building
180Supplying and fixing of Wall paneling made of aluminum anodised section framing conforming to standard Aluminium sections as horizontal and vertical members with atleast 600mm c/c and fixing of 9mm thick BWR ply with 4mm thick veneer pasting finished with melamine polishing complete.
181Ground Floor
182Office Building
183First Floor
184Office Building
185Second Floor
186Office Building
187Providing & Installation of GFRC GFRC JALI (Glass Fiber Reinforced Concrete) thickness of 25-30 mm & Border thickness of 50 mm with Pattern, design, and colour of approved make to be fixed on/between RCC/Block work Column or structural work with Dry Fixing method with appropriate SS Pipe & Cleats frame work, using fasteners, and necessary hardware etc. The element shall be made from '53 grade' Portland Cement make Birla/ 'JK Cement' or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass fibre make 'Owens Corning' or equivalent, Super plasticizers/Additives make by 'BASF' or equivalent, Polymers make 'BASF' or equivalent and U.V resistant Synthetic inorganic pigments shall be used for pigmentation make 'BAYFERROX (Germany)' or equivalent. The material casting shall take place in Synthetic Rubber/FRP Mould manufactured by Mould/Tool/ Mould Grade Resin of Revex/ 'Reckli' or equivalent.
188Ground Floor
189Office Building
190First Floor
191Office Building
192Second Floor
193Office Building
194Providing fitting and fixing of false ceilling with Aluminum anodised T section No 3215 with 2'-0\\" center to centre, L section No 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0\\" x 2'-0\\" using 12.5 mm thick gypsum board of size 6'x4'suspended from ceilling etc complete as directed by the Engineer-in-charge
195Ground Floor
196Office Building
197First Floor
198Office Building
199Second Floor
200Office Building
201Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures.
202Ground Floor
203Office Building
204First Floor
205Office Building
206Second Floor
207Office Building
208Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. (per one Sq. Mtr.) (Data for 10 sqm.) INCLUDING COST OF MATERIAL &Labour
209Ground Floor
210Office Building
211Boundary wall with gate
212Utility Building
213First Floor
214Office Building
215Second Floor
216Office Building
217Terrace Floor
218Office Building
219Priming one Coat on Plastered Surface INCLUDING COST OF MATERIAL & Labour
220Inside Surface
221Ground Floor
222Office Building
223Utility Building
224First Floor
225Office Building
226Second Floor
227Office Building
228Priming one Coat on Plastered Surface INCLUDING COST OF MATERIAL & Labour
229OutSide Surface
230Ground Floor
231Office Building
232Utility Building
233Boundary wall with gate
234First Floor
235Office Building
236Second Floor
237Office Building
238Terrace Floor
239Office Building
240Wall painting TWOcoats with plastic emulsion paint of approved shade on new work to give an even shade including cost of brushes and paint. (per one Sq. Mtr.) (Data per 10 Sqm.) INCLUDING COST OF MATERIAL &Labour
241Ground Floor
242Office Building
243Boundary wall with gate
244Utility Building
245First Floor
246Office Building
247Second Floor
248Office Building
249Wall painting 2 coats with weather paint of approved shade on wall surface to give an even shade including cost of brushes and putty including cost of paint scrapping, cleaning rubbing, scaffolding etc. (per one Sq. Mtr.) (Data per 10 Sqm.) INCLUDING COST OF MATERIAL &Labour
250Ground Floor
251Office Building
252Boundary wall with gate
253Utility Building
254First Floor
255Office Building
256Second Floor
257Office Building
258Terrace Floor
259Office Building
260Finishing walls with water proofing cement paint of approved shade on new work TWO coats to give an even shade including cost of brushes and putty including cost of paint. (per one Sq. Mtr.) (Data per 10 Sqm.) INCLUDING COST OF MATERIL &Labour
261Ground Floor
262Boundary wall with gate
263Expansion Joint Treatment
264Ground Floor
265Office Building
266First Floor
267Office Building
268Second Floor
269Office Building
270Terrace Floor
271Office Building
272Providing two coats of water proofing painting with 100% Dr. Fixit Replin MR and sika Guard-625 exterior grade with melamine polish and A1 thineer of approved make & shade manufactured of approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labour, T&P, sundries etc as per required for the work complete in all respect as per direction of Engineer-in-charge.
273First Floor
274Office Building
275Second Floor
276Office Building
277Terrace Floor
278Office Building
279Priming one Coat on wood INCLUDING COST OF MATERIAL & Labour
280Ground Floor
281Office Building
282First Floor
283Office Building
284Second Floor
285Office Building
286Priming one Coat on Steel INCLUDING COST OF MATERIAL & Labour
287Ground Floor
288Office Building
289Boundary wall with gate
290Utility Building
291First Floor
292Office Building
293Second Floor
294Office Building
295Painting two Coats with approved Synthetic Enamel paint on new wood / iron work INCLUDING COST OF MATERIAL &Labour
296Ground Floor
297Office Building
298Boundary wall with gate
299Utility Building
300First Floor
301Office Building
302Second Floor
303Office Building
304Providing & Fixinng factory made 100% Solid WPC (Wood Polymer Composite ) - Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comparising of virgin PVC polymer of K Value 57-60 (Suspension Grade ), Calcium Carbonate and Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015 Certified Company, having good screw holding capacity (Screw Withdrawal strength of ( Min. 990 N ),Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water/Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght,, all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company.
305Ground Floor
306Office Building
307Boundary wall with gate
308First Floor
309Office Building
310Second Floor
311Office Building
312Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete
313Ground Floor
314Office Building
315First Floor
316Office Building
317Second Floor
318Office Building
319Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
320Ground Floor
321Office Building
322Second Floor
323Office Building
324Supplying & fixing M.S Grills made out of G.I Angle, Square bars & flats etc including the cost of materials and labour including grouting of existing column and wall holes etc all complet as per the direction of Engineer in charge.
325Ground Floor
326Office Building
327Utility Building
328Boundary wall with gate
329First Floor
330Office Building
331Second Floor
332Office Building
333Labour for fitting and fixing of M.S. window grills including cost of screws complete
334Ground Floor
335Office Building
336Utility Building
337First Floor
338Office Building
339Second Floor
340Office Building
341Supplying and installing UPVC-3 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58 mm x 32mm and sash dimension of 61mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass of make - Saint gobain/AIS/Goldplus. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge
342Ground Floor
343Office Building
344First Floor
345Office Building
346Second Floor
347Office Building
348Supplying & fixing of NCL Roll Formed Section for Structural Glazing made of galvanized steel colour coated/ power coated (Base Steel as per IS 513 'D' quality galvanized thickness of 0.72mm. The Glass holding section made of 304 grade stainless steel of 0.6mm thick. CRCA sections with Polyurethane Coating are to be used as stiffeners inside the CCS section as per the design requirement. Paint Specifications coated sections should be with Primer coat of Epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns, or Powder Coated with pure Polyester Powder up to 50-60 microns thick. Dimensions of Sections. The sections are to be of 100x50 mm for frame verticals, 33x57 mm for frame horizontals, section for reinforcement should be of 31x55mm/48x98 mm (CRCA). Glass holding section should br of 32.5x37 mm for top and bottom grids, in between should be of 32.5 x 18mm.
349Ground Floor
350Office Building
351First Floor
352Office Building
353Second Floor
354Office Building
355Providing and Fixing of 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of the Engineer-in-Charge.
356Ground Floor
357Office Building
358Supplying, fittin and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost, conveyance, taxes of all MATERIALas, labour, T&P etc. required for the complete in all respect.
359Ground Floor
360Office Building
361First Floor
362Office Building
363Second Floor
364Office Building
365Supplying, fitting and fixing vitrified tile in floor of size 600 mm x 600 mm of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-charge.
366Ground Floor
367Office Building
368Boundary wall with gate
369Utility Building
370First Floor
371Office Building
372Second Floor
373Office Building
374Providing & Fixing Vitrified Tiles in Dados skirting and risers of steps on 12 mm thick cement plaster (1:3) Jointed with Neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per the direction of Engineer-In-Charge.
375Ground Floor
376Office Building
377Boundary wall with gate
378Utility Building
379First Floor
380Office Building
381Second Floor
382Office Building
383Supplying, fitting and fixing Granites Tiles of Above 0.10 Sqm & up to 0.4 Sqm (10mm.thick) . floor tiles of premium grade having thickness 7 mm to 8 mm confirming to IS-13755 of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-charge.
384Ground Floor
385Office Building
386First Floor
387Office Building
388Second Floor
389Office Building
390Providing & Fixing Granite Tiles of Above 0.10 Sqm & up to 0.4 Sqm (10mm.thick) wall tiles in Dados skirting and risers of steps on 12 mm thick cement plaster (1:3) Jointed with Neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per the direction of Engineer-In-Charge.
391Ground Floor
392Office Building
393Boundary wall with gate
394First Floor
395Office Building
396Second Floor
397Office Building
398Supplying, fitting and fixing Marble Tiles of minimum 16 mm. thick, dunguri variety. floor tiles of premium grade having thickness 7 mm to 8 mm confirming to IS-13755 of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-charge.
399Ground Floor
400Office Building
401Utility Building
402Providing & Fixing Marble Tiles of minimum 16 mm. thick, dunguri variety wall tiles in Dados skirting and risers of steps on 12 mm thick cement plaster (1:3) Jointed with Neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per the direction of Engineer-In-Charge.
403Ground Floor
404Office Building
405Utility Building
406Supplying, fitting & fixing Vetrified industrial floor Tile of premium grade having thickness 8mm to 10mm confirming to IS 4457 of size 300mmx300mm of with veilcraft (VC/FT ) shield( Scratch free/stain free) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )
407Ground Floor
408Office Building
409Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete
410Ground Floor
411Office Building
412First Floor
413Office Building
414Second Floor
415Office Building
416Providing & Fixing 20cm x30cm / 20 cm x 20 cm special plain / printed series ceramic wall tiles of premium grade having thickness 6.5 mm to 6.7 mm confirming to IS-13753 in Dados skirting and risers of steps on 12 mm thick cement plaster (1:3) Jointed with Neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per the direction of Engineer-In-Charge.
417First Floor
418Office Building
419Second Floor
420Office Building
42140 mm Thick Grading Concrete in C.C.(1:2:4) using 12 mm down graded H.G. chips.with chicken mesh
422Ground Floor
423Utility Building
424First Floor
425Office Building
426Second Floor
427Office Building
428Terrace Floor
429Office Building
430Iron Works Wrought and put up in trusses and record racks.
431Terrace Floor
432Office Building
433Labour for fixing G.C.I. Sheet in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. excluding cost of fitting per 1 Sqm.
434Terrace Floor
435Office Building
436Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete
437Ground Floor
438Boundary wall with gate
439Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
440Ground Floor
441Boundary wall with gate
442Labour for fitting and fixing of M.S. Gates as per approved design including cost of all materials complete
443Ground Floor
444Boundary wall with gate
445Providing and Fixing of WPC boards of sizes as mentioned below along with 3D letter inlays on the same with the required letters to be approved by the Architect/ EIC. Samples have to be approved by the concerned before execution. The rate is inclusive of the WPC board with fixing of the same along with Rates, Taxes, T&P all inclusive. SIZE-450X300
446Ground Floor
447Boundary wall with gate
448M.S.Panneled Door double leaved shutter with M.S.frame overall size including frame:- 1980mm (H) x 1070mm (W) made out of the following materials conforming to relevant Indian Standard specifications. Frame :- 35x35x6mm M.S.angle, Shutter style :- Top & Bottom rail 25x25x3mm M.S.angle, Door panel :- 10mm C.R.Sheet. Panel stiffener covering width of each leaf :- 19x5mm M.S.Flat 3nos on each leaf. Hinges size :- 100mm 6nos (3nos each side) bought out as per ISS. Hold fast :- 35 x 35x 6mm M.S.Angle 175mm length bifurcated at the tip 3nos on each side. Handle :- 19x5mm M.S.Flat fabricated 4nos. Aldrop :- 2nos bought out as per ISS. Tower bolt :- 2nos bought out as per ISS. Approximate weight :- 63 Kgs
449Ground Floor
450Utility Building
451M.S.Panneled Door single leaved shutter with M.S.frame overall size including frame:- 1830mm (H) x 910mm (W) made out of the following materials conforming to relevant Indian Standard specifications. Frame :- 30x30x5mm M.S.angle, Shutter style :- Top & Bottom rail 25x25x3mm M.S.angle, Door panel :- 1.0mm C.R.Sheet. Panel stiffener covering width of leaf :- 19x5mm M.S.Flat 3nos. Hinges size :- 100mm 3nos bought out as per ISS. Hold fast :- 30 x 30x 5mm M.S.Angle 150mm length bifurcated at the tip 3nos on each side. Handle :- 19x5mm M.S.Flat fabricated 2nos. Aldrop :- 2nos bought out as per ISS. Tower bolt :- 2nos bought out as per ISS. Approximate weight :- 49 Kgs
452Ground Floor
453Utility Building
454M.S.Panneled Window double leaved shutter with M.S.frame & Grill overall size including frame:- 1220mm (H) x 910mm (W) made out of the following materials conforming to relevant Indian Standard specifications. Frame :- 35x35x6mm M.S.angle, Shutter style :- Top & Bottom rail 25x25x3mm M.S.angle, Door panel :- 1.0mm C.R.Sheet. Panel stiffener covering width of each leaf :- 19x5mm M.S.Flat 2nos on each leaf. Hinges size :- 100mm 4nos (2nos each side) bought out as per ISS. Hold fast :- 35 x 35x 6mm M.S.Angle 100mm length bifurcated at the tip 2nos one each side. Handle :- 19x5mm M.S.Flat fabricated (inside) 2nos. Tower bolt :- 4nos bought out as per ISS. Horizontal Grills :- 12mm M.S.Round at 100mm spacing. Approximate weight :-39Kgs
455Ground Floor
456Utility Building
45725 mm A.S Flooring in C.C.(1:2:4) including punning using 12-20 mm H.G. chips. (Per one Sq.Mtr.)
458Ground Floor
459Utility Building
460Providing & applying Sika top seal 109 HI over roof slab and parapets before application of SIKA Top seal 109HI the surface should be prime with SIKA 109HI primer, SIKA Fab 1 shall be laid between the coats of water proofing membrane, the entire application cover with SIKA TOP seal HI CC (curing compound) including cost of all materials,Conveyance, labour, T&P etc. complete in all respect as per specification and direction of Engineer-in-charge. EIC.
461Ground Floor
462Utility Building
463Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site by mechanical means within a lead of 5 kms, spreading, grading to required slope and compacting to meet requirementof table 300-2 & Clause 305 of MoSRT&H Specifications for Road & Bridge works(4th Revision)
464Site Development
465Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.
466Site Development
467Providing G.S.B. Gr-VI stone screaning materials, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, as per approved Drawing & Technical Specifications and as per Clause - 401 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost, conveyance, royality & other taxes of materials, cost of labour, machinery, T&P etc complete.
468Site Development
469Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per approved Drawing & Technical Specifications and as per Clause -406 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost, conveyance, royality & other taxes of materials, cost of labour, machinery, T&P etc complete.
470Site Development
471Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018.
472Site Development
473Supplying and fixing of Pre cast kerb stone of size 300mm x 600mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect confirming to IS 5758:1984.
474Site Development
475Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm.
476Site Development
477Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
478Landscaping
479Supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment).
480Landscaping
481Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts(cost of manure, sludge or extra good earth if needed to be paid for separately)
482Landscaping
483Holes 1.2 m dia and 1.2 m deep
484Holes 90 cm dia, and 90 cm deep
485Holes 60 cm dia, and 60 cm deep
486Holes 45 cm dia, and 45 cm deep.
487Making tree guard 53 cm dia and 1.3 m high as per design from empty coal tar drums, supplied free by the department, including providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed with rivets complete in all respects including painting inside and outside of tree guard with:
488Landscaping
489Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos (3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge.
490Landscaping
491Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
492Landscaping
493Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer in charge. (The cost of good earth, earthen pots & manure will be paid separately.)
494Landscaping
495Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge.
496Landscaping
497Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/edge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.
498Landscaping
499Providing and wartering of plants through water tanker of Horticulture features i.e. lawn, tree, shrubs, hedge/edge, ground cover etc. at the site of work. Water tanker having 5000 lit. capacity with one labour for watering i/c cost of water, filling of tanker, wartering at site with all leads and lifts as per direction of officer-in-charge.
500Landscaping
501Anti termite treatment by digging holes 300mm deep and 40 mm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.as per direction of officer-in-charge.
502Landscaping
503Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.
504Landscaping
505Providing and displaying of Araucaria cookie plant, having ht. 1.80 m to 1.95 m, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
506Landscaping
507Providing and displaying of Areca Palm plant, having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
508Landscaping
509Providing and displaying of Croton Golden specimen plant, having ht. 90 cm to 1.05 cm with 5 to 6 branches, well developed, fresh and healthy foliage in 30 cm size of Earthen pot/Plastic pot as per direction of the officer-in-charge.
510Landscaping
511Providing and displaying of Seaforthia Palm plant, having ht. 1.50 m to 1.80 m with 12-15 suckers, well developed, fresh and healthy lush green leaves from bottom to top in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
512Landscaping
513Providing and Displaying Golden Bottle brush Topiary well developed with fresh & healthy foliage 5 to 6 big ball 115 to 180 cm ht in 40 cm Cement Pot as per direction of the officer-incharge.
514Landscaping
515Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge.
516Landscaping
517Providing and Displaying Chrysanthemum double variety, well developed, having 45 to 60 cm ht., with 6 and above flowers with half blooming condition, fresh and healthy with bamboo stacking in 25 cm Earthen Pot and as per direction of the officer-in-charge.
518Landscaping
519Providing and stacking of Clerodendrum inerme of ht. 20 cm to 30 cm multi branched in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.
520Landscaping
521Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cost of plant & water)
522Landscaping
523plantation per Tree
524plantation per Hedge/Ground cover
525Electrical Work
526Internal Work Sub-Head I (Moudular Wiring Items)
527Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
528GROUP-A
529GROUP-B
530GROUP-C
531Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
532Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
533Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
534Supplying and fixing of ISI marked modular type 2 nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & warranty certificate to be submitted to the department for the genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make : Legrand (Myrius)/ Schneider(Zencelo)/ PANASONIC(VISION)
535Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
536Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.
537Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
538Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
539Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
540Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
541Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)
54220 MM
54325 MM
544Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
545S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
546Sub-Head II (Light fitting Fixture & Fan)
547Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
548Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
549Supplying, installation, testing and commissioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make- Crompton Energion Groove/ Havells Efficiencia Neo/ Usha Technix/ Bajaj Turbo Pro 12DC5) including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Eng.-in-Charge, Replacement Warranty will be 4 years.
550Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.(To be used in small office rooms, toilet area, corridor area etc.)
551Supplying an fixing of recess/surface mounted 2'x2' 25 W(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years.(To be used in conference room, auditorium, district office, aquarium,canteen,establishment section,OSWAN, research dev. & training,audit, law. planning, budget section, cash section, statistics, record room, chamber for JDF,RTI & dedicated cell, publicity, marine, brackish water,co-operative, coordination, SPU, Mechnical section, recreation room, world fish, e-library, yoga&meditation hall, engineering section etc.)
552SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .(To be used in parking)
553SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
554Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
555S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision))
556BDBS,DB,AC DB,FLOOR PANELS,MCBS
5574 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,ComputerDB)
5588 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years (CONFERENCE ROOM)
559Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year..
560Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
561Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
562Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
563Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year.
564Supplying and fixing 32 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year..
565Supplying and fixing 32 Amps 4P, 415 volts RCCB 30mA MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year..
566(Earthing) INSTALLATION
567Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
568Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Tapping from 50mm x 6 mm bus bar to all sub panel
569Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. 2 runs from main LT room to electrical shaft upto 5th floor
570CABLING AND END TERMINATION MAIN AREA
571Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
5723.5core x 300 sq mm FOR TRANSFORMER
5733.5core x 150 sq mm FOR DG 2 runs,VRF panel
5743.5core x 50sq mm FDB POWER
5754core x16 sqmm Aluminium conductor cable
576LAYING OF CABLE
577Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
578Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
579Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
580Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
581Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.
582Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.
583Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
584Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
585Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
586Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
587Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
5883.5 core x300 sq mm
5893.5 core x150 sq mm
5903.5 core x50 sq mm
5914core x16 sqmm Aluminium conductor cable
592Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
59350 mm dia
594Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
595200 mm dia
596PANELS
597S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.80X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication.
598In commer-1-01 number of 630(40% I n rated-100% I n rated) 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula
599In commer-2-01 number of 400A 4P Icu=100%Ics,36kA LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
600In commer-2- 01 no of 400A 4P onload changeover switch (250 KVA DG 01 NO)(Make-C&S/LK(L&T)/Siemens/Schneider/ABB)
601Busbar-1&2 04 numbers of 900Amps al busbar with busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
602Out going- 04 numbers of 125A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
603Out going- 4 numbers of 100A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
604Out going-6 numbers of 40-63A rating,10 KA breaking capacity,C series, 4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB sb200)
605Outgoing-02 number of 400A 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
606Outgoing-03 number of 200A 4P Icu=100%Ics,25kA LSIG MCCB with TMR Release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
607Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.
608(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data.
609(iii)All the outgoing feeders shall have digital ammeter with CT accuracy class 1 of suitable rating.
6102 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND/ Siemens/ Schneider/ABB/OBO/Dehn)
611FLOOR PANEL POWER 1F,2F,LIFT
612S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication.
613In commer - 01 no 125A 4P MCCB 25kA, with ROM & S. Link. withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) (Icu=100%Ics)with shunt trip.
614Busbar- 04 numbers of 150Amps, aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
615Out going- 04 nos 63A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200
616Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
617(ii) 01 set of MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)
618FLOOR PANEL LIGHT 1F,2F,COMMON
619S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication.
620In commer - 01 no 100A 4P MCCB 16kA, with ROM & S. Link. withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) (Icu=100%Ics)with shunt trip.
621Busbar- 04 numbers of 150Amps, aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
622Out going- 04 nos 40A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200
623Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
624(ii) 01 set of MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)
625UPS PANEL
626S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawingas per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication.
627In commer - 01 no 63A 4P MCCB 16kA, with ROM & S. Link. withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) (Icu=100%Ics)with shunt trip.
628Busbar- 04 numbers of 100Amps, aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
629Out going- 8nos 40A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(UPS BDB EACH FLOOR)
630Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
631(ii) 01 set of MFM with CTS.(DIGITAL) (LEGRAND/ Siemens/ Schneider/ABB)
632UPS floor PANEL
633S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawingas per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication.
634In commer - 1 nos 40A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200
635Busbar- 04 numbers of 100Amps,aluminum busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
636Out going- 04 nos 32A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(UPS BDB EACH FLOOR)
637Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
638(ii) 01 set of MFM with CTS.(DIGITAL)(LEGRAND/ Siemens/ Schneider/ABB)
639AC VRF OUT DOOR PANEL
640S/I/T&Commissioning of CPRI Approved LT OUTDOOR,IP 66 floor mounted cubical type electrical main panel (for AC ODU) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 40 kA SPD with 63A rating,10KA breaking capacity ,4P MCB shall be installed in the incomer.40x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.
641In commer 1- 01 no 200A 4P MCCB Icu=100% Ics,,25Ka MCCB with TMR based release with adjustable overload ( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA).
642Busbar-1&2 04 numbers of 300Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
643Out going- 6 nos 63A 4P RCBO,300MA. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200)
644Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
645(ii) 01 set digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication
646CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
647Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
648Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
649Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge.
650Supplying,fixing of 8 module unde- FLOOR outlet box IP20 size not less than 308x308mm as required as per direction of Engg.-in-Charge.
651UPS SYSTEM(For COMMON AREA)
652Supply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 100AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) LOAD ) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.
653LIGHTING PROTECTION SYSTEM
654Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
655Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make OBO/Dehn/ABB
656Supply of Roof conductor holder SS Conductor holder with bottom section & conductor holder (v2a) bottom section with 8.5mm dia slot. as per direction of engineer in charge.Make-OBO/Dehn/ABB.
657Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB
658Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
659Supply of Vertical air terminal with accessories: Providing of Air terminals as per IS-IEC-62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AIMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB
660Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp made up of frost resistant concrete and clamp tested upto 100KA lightning current. Make-OBO/Dehn/ABB
661Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB
662Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
663Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
664Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB
665Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
666Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB
667Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
668Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB
669Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB
670Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
671Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB
672Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make- OBO/Dehn/ABB
673Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
674EXTERNAL ILLUMINATION
675S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty)
676Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge.
677Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge.
678Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.
679Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
680S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
681Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
682S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials
683Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make-Polycab/KEI/Finolex/Havells/RR kabel/Gloster
684Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
685Subhead- 1 (Lan System)
686SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
687SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
688SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
689SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
690SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit
6911mtr Length
6922mtr Length
693SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear
694SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
695SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand
696SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
697SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
698SITC of 1G-LX/LH SFP transceiver module,. Make: Cisco, Digisol, Netgear
699SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
700Subhead - 3 (IP-CCTV System)
701Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 50m(bullet)/40m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.8mm(Dome)/3.6mm(bullet), Field of View FoV H:96.5°, V:73.8°(dome)/ Field of View FoV H:94.1°, V:71°(bullet), BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell Value series/Pelco/Axis/Bosch
702Supply , Installation, testing , commissioning of 64 Channel NVR with 8 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).Make-Honeywell value series /Pelco/Axis/Bosch
703Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
704SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer
705SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
706PA SYSTEM
707Supplying, installing, testing and commissioning of Power mixture amplifier of 1000 watt.The amplifier should be clean reliable audio for public address amplification.Line input less than 1 volt, unbalanced& line output less than 1 volt unbalanced.Make-Honeywell/Bose/Bosch.
708Supplying, installation, testing & commissioning of 8 zone voice alarm controller with USB MP3 am/fm included 8 zone button paging station and microphoneMake. Honeywell/Bose/Bosch
709Supplying, installing, testing and commissioning of 12 Watt wall mounted speakers with built in line matching transformer, grill flush mounting type in side the utility rooms.Make-Bosch/Bose/Honeywell. Please Enable Macros to View BoQ information
710Supplying, installing, testing and commissioning of 12 Watt wall mounted speakers with built in line matching transformer, grill flush mounting type in side the utility rooms.Make-Bosch/Bose/Honeywell. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57021591
AUTHORITY Government Departments
TENDER VALUE 14.62 Crore
LAST DATE 03-09-2026
Authority
Authority Name Agriculture And Farmers Empowerment Department
Work Description Tender for Construction Of Research Wing & Administrative Building At Rrtts, Bhubaneswar (Composite)
Basic Detail
Tender No 03/2026-27
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 14 Aug 2026
Submission Date 03 Sep 2026
Open Date 08 Sep 2026
Finance
Tender Value 14.62 Crore
Tender Fee 10000
EMD 14.62 Lakhs
Exemption Available
Document List
BOQ_606000.xls
dtcn1.pdf
e2c791e8-bc7e-4ffa-b908-7639c192fa48.html
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_606000.xls

pdf

dtcn1.pdf

html

e2c791e8-bc7e-4ffa-b908-7639c192fa48.html

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders