Tender For Construction Of Community Hall At Urja Vihar Colony, Omkareshwar Power Station
Tender Value
99.84 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
6 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
East Nimar → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Community Hall At Urja Vihar Colony, Omkareshwar Power Station
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil |
| 2 | Providing and laying in position cement concreteof specified grade excluding the cost of centering and shuttering - All work upto plinth level :M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate) |
| 3 | Providing and laying in position specified grade of reinforced cement concrete (nominal / design mix with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level M-20 Grade Concrete |
| 4 | Centering and shuttering in cluding strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 5 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Upto plinth level. |
| 6 | Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete. Cement Mortar 1:6 (1 cement: 6 sand). |
| 7 | Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 8 | Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete.Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. |
| 9 | Preconstruction antitermite treatment Preconstruction antitermite treatment to the building under construction by providing. Stage 1: Treating the bottom and the sides (upto 30 cm height of the excavated trench @ 5 liters per sqm of the surface area. Stage 2: After masonry/RCC work, the backfill in the immediate contact with the foundation structure treatment @ 7.5 liters per sqm. Of the vertical surface of the substructure for each side. Stage 3: surface treatment by spreading emulsion over the plinth area before laying the base concrete under floors @ 5.0 litres/Sqm. Stage 4: Pumping the emulsion in plinth masonry on filling side at floor junction @ 7.5 litres/Sqm. Stage 5: Pumping the emulsion from outer side of the plinth below ground around the masonry @ 5.0 litres/Sqm as per I.S. 8944 Emulsion. (1Chlorpyrifos: 19 water) with five years service guarantee (Measurements to be taken for plinth area) Note – Treatment should start when foundation trenches and pits are ready to take bed concrete or leveling course in foundations. Lying of bed concrete should start when the chemical emulsion has been absorbed by the soil and the surface is reasonably dry. Treatment should not be carried out when it is raining or when soil is wet with rain or subsoil water. This also applies to fill up soil within the plinth area before laying the subgrade for flooring. |
| 10 | Plinth protection by C.C.Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) |
| 11 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement:M-20 Grade Concrete |
| 12 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade.M-20 Grade Concrete |
| 13 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars. FE 500 D or more conforming to IS 1786 |
| 14 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Columns, Pillars , Piers, abutments, Posts and Struts. |
| 15 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers |
| 16 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 17 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc., including Edges. |
| 18 | Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. Cement mortar 1:6 (1 cement : 6 sand) |
| 19 | Half brick masonry open bhatta bricksProviding half brick masonry with well burnt open bhatta bricks crushing strength not less than 25 kg /cm2 and water absorption not more than 20% in superstructure above plinth level and up to floor two level. Cement mortar 1:4 (1 cement : 4 sand) |
| 20 | Structural steel work using M.S. flats, angles, channels I-section, H-section etc.riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 21 | M.S. grills and windowsProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 22 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 300x16 mm |
| 23 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 250x16 mm |
| 24 | Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete: 250x16 mm |
| 25 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 250x10 mm |
| 26 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 150x10 mm |
| 27 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper |
| 28 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125 mm |
| 29 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 sand) |
| 30 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) |
| 31 | 12 mm cement plaster of mix : (1 cement : 4 sand) |
| 32 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion.: Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 33 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per Architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) |
| 34 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg/sqm ) |
| 35 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body /plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge : With stainless steel cover plate - minimum 1.25 mm thickness |
| 36 | Pressed steel door frames Providing and fixing pressed steel door frames made of 1.6 mm thick steel profile conforming to IS: 4351 manufactured from commercial mild steel sheet including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm pressed mild steel welded or rigidly fixed together by mechanical means, including 2.5mm thick M.S. pressed butt hinges, with mortar guards, lock strikeplate and shock absorbers as specified filling the frame with Cement Concrete 1:3:6 at site before fixing (cost of concrete to be paid separately) fixing with adjustable lugs (200 mm long & 1.0 mm thick) and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in- charge: Profile B of 1.60mm thick single rebate of size 80mmx50mm Fixing with adjustable lugs with split end tail to each jamb. |
| 37 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 38 | Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice .husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed S.S. screws having minimum density of 750 kg/m3 and screw withdrawal strength of 2200 N (Face) & 900 N (Edge), minimum compressive strength 58 N/mm2, modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S. hold fast/lugs/S.S.dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/lugs or S.S. dash fasteners shall be paid separately) Single rebate (75 mm X 50 mm) |
| 39 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice.husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter |
| 40 | 40 mm thick Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate) 20mm nominal size stone aggregate in panels finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(Area of panel not to exceed 2.0 sqm) |
| 41 | Providing and laying gang saw cut 18 mm thick, mirror polished premoulded (wherever required) and pre polished machine cut granite stonework in flooring of required size shape of approved shade, color and texture in flooring laid over 20 mm thick base of cement mortar 1:4 (1 Cement: 4 sand) including grouting the joints with white cement mixed with matching pigments epoxy touch ups etc. complete as per direction of Engineer-in-Charge. Area of slab over 0.50 sqm Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter |
| 42 | Extra for marble /granite stone in facia and drops Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. |
| 43 | Extra for providing opening in marble /granite /stone work Extra for providing opening of required size and shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 44 | Edge moulding of stone work Providing edge moulding to 18mm thick marble stone counters, Vanities, window sills etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work |
| 45 | Ceramic glazed floor tilesProviding and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 46 | Ceramic glazed wall tilesProviding and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of Chief Engineer will be required. |
| 48 | Wall painting by any mechanical or manual means with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats. |
| 49 | Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface) |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 51 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete 100X58X1.90 mm |
| 52 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia nominal bore |
| 53 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia. nominal bore |
| 54 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall 32 mm dia. nominal bore |
| 55 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. External work : including trenching and refilling etc. 50 mm dia. nominal bore |
| 56 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore |
| 57 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore. |
| 58 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. |
| 59 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore. |
| 60 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore |
| 61 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gm, 15 mm nominal bore |
| 62 | Providing and fixing C.P. brass two way bib cock with wall flange of approved quality conforming to IS standards, 15 mm nominal bore |
| 63 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 25 mm nominal bore |
| 64 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 32 mm nominal bore. |
| 65 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 50 mm nominal bore. |
| 66 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 67 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 68 | Providing and fixing on wall face Rigid Unplasticised rigid PVC (upvc) Single socketed rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 110 mm diameter (minimum wall thickness 2.2mm) |
| 69 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend (minimum wall thickness 2.2mm) |
| 70 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe (minimum wall thickness 2.2mm) |
| 71 | Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 72 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm (minimum wall thickness 2.2mm) |
| 73 | UPVC trap of self cleaning designProviding and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 74 | Providing and fixing to the inlet mouth of rain water pipe fixing cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 75 | W.C. Indian type with flushing cisternProviding and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast Iron P or S trap, UPVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 76 | W.C. European type PVC flushing cisternProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 77 | Kitchen sink (stainless Steel) (610x510 mm)Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mm. |
| 78 | Wash basinProviding and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. |
| 79 | Unplasticised rigid PVC soil and waste pipesProviding and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) 75 mm diameter |
| 80 | Unplasticised rigid PVC soil and waste pipesProviding and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. (minimum wall thickness 3.2mm) 110 mm diameter |
| 81 | Unplasticised PVC pipe fittingsProviding and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 110 mm |
| 82 | Unplasticised PVC pipe fittingsProviding and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm |
| 83 | Unplasticised PVC pipe fittingsProviding and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm |
| 84 | Unplasticised PVC pipe fittingsProviding and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5, 110 mm bend |
| 85 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe (only in residential & complaxes) 32 mm dia |
| 86 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia |
| 87 | PTMT grating (125 mm)Providing and fixing PTMT grating of approved quality and colour. Circular type. 125 mm nominal dia with 25 mm waste hole. |
| 88 | Grating C.P. brass (100 mm)Providing and fixing C.P. brass grating of approved quality and make conforming to IS: specification. 100 mm dia. |
| 89 | Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 90 | Towel Rail (600 x 20 mm)Providing and fixing CP brass towel rail of approved quality and make 600x20mm |
| 91 | Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation to be paid seperataly. 250 mm diameter OD (min. wall thickness 6.2mm) |
| 92 | Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size) all-round PVC. pipes including bed concrete as per standard design: 250 mm diameter PVC pipe |
| 93 | S.W. gully trapProviding and fixing squaremouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100 mm size P type. With well burnt bricks |
| 94 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With well burnt bricks |
| 95 | Urinal flat back or wall corner type with automatic flushing cistern : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern. |
| 96 | Providing for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. Preparation of Drip course |
| 97 | M.S. Fan clampsProviding and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. |
| 98 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 99 | Connection of drain with existing manhole Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 230 mm diameter |
| 100 | Preparation of the structure design & drawing by structure engineer empanelled with the chief architect MP PWD on the basis of architectural drawing supplied / approved by the department in accordance with relevant code / manual and according to the “terms & conditions”, prescribed in activity Sheet No-1\\", List-4\\" given in Annexure-14 appended with SOR. The work shall include site visit, verification of soil testing report, topography, contours etc. made available to the structural engineer The structural engineer is not satisfied with adequacy of geotechnical reports, he may engage a geotechnical engineer and get the soil investigation done, for which charges are payable separately, according to relevant item of SOR, to satisfy himself that the design is optimal. If design work pertains to a work to be done over an existing structural, the structural engineer shall get structural soundness study done for which payment shall be made separately. The structural engineer shall do revision/ compliances of the structural design and drawings, if required, without any additional cost with-in stipulated time and obtain approval from to the competent authority. Design and drawing shall also include ‘Tables’ for the bar bending schedules (BBS) and concrete/steel consumption. The design and drawing shall besubmitted to the Engineer-in-Charge in six hard copies and one soft copy for execution. The payment shall be done in accordance with relevant stage in activity sheet and list. Built up area more than 500 sqm and upto 3000 sqm. |
| 101 | Point wiring concealed rigid P.V.C. conduit : Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary short point |
| 102 | Point wiring concealed rigid P.V.C. conduit : Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary medium point |
| 103 | Point wiring concealed rigid P.V.C. conduit : Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Light point/fan points. Primary long point |
| 104 | Point wiring concealed rigid P.V.C. conduit : Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as per specification for :- Looping point secondary, (Light point/fan points) looping point, Secondary Medium point |
| 105 | Power point wiring surface rigid P.V.C. conduit: Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp.F.T. switch & socket/S.S. combined 20/16/6Amp. of ISI marked and 4sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-Power point On separate board, Short Point |
| 106 | Power point wiring surface rigid P.V.C. conduit: Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp.F.T. switch & socket/S.S. combined 20/16/6Amp. of ISI marked and 4sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-Power point On separate board, Medium Point |
| 107 | Power point wiring surface rigid P.V.C. conduit: Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp.F.T. switch & socket/S.S. combined 20/16/6Amp. of ISI marked and 4sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-Power point On separate board, Long point |
| 108 | Power point wiring surface rigid P.V.C. conduit: Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp.F.T. switch & socket/S.S. combined 20/16/6Amp. of ISI marked and 4sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-Power point On separate board, Extra Long-I |
| 109 | Power point wiring surface rigid P.V.C. conduit: Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp.F.T. switch & socket/S.S. combined 20/16/6Amp. of ISI marked and 4sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-Power point On separate board, Extra Long - II . |
| 110 | Power point wiring surface rigid P.V.C. conduit: Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4 sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp.F.T. switch & socket/S.S. combined 20/16/6Amp. of ISI marked and 4sq. mm. PVC insulated FR-LSH copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-Power point On separate board, Extra Long - III . |
| 111 | Modular G.I. metal box (concealed) : Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 6 Module metal box |
| 112 | Modular G.I. metal box (concealed) : Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 12 Module metal box |
| 113 | Modular G.I. metal box (concealed) : Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 16 Module metal box |
| 114 | Sub mains in recessed/concealed rigid PVC conduit (HMS): Wiring for sub-mains with PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification.(Refer General Notes for Classification of Conduit Wiring Point No.8) 3 Wire sub main 4.0 sq. mm. cable |
| 115 | MCCB 3Ph, 3Pole, 50Hz, 415V (Micro-processor release) : Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with Micro-p rocessor release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2, MCCB 25kA current rating - 40 & 100Amp 3 Pole µ-processor release, over load 40% -100% x In. & short circuit 1.5 - 8 x Ir. Adjustable |
| 116 | MCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kA : Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- SingLe Pole , MCB SP 6Amp to 32Amp 10kA rating |
| 117 | MCB 'C' Series, 240/415V, 50 Cycle, 10kA/15kA : Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- Double Pole MCB DP 6Amp to 32Amp 10kA rating |
| 118 | SPN MCB DB :Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 6 Way double door IP 43 protection |
| 119 | SPN MCB DB :Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as perIS:13032(exclusive of MCB & isolator)- 12 Way double door IP 43 protection |
| 120 | SPN MCB DB :Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)- 16 Way double door IP 43 protection |
| 121 | TPN MCB DB double door: Supplying of approved make TPN MCB DB metaldouble door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator): 4 Way (8+12) |
| 122 | Vertical TPN MCB DB, with provision for MCCB upto 160A TP/FP 36kA, double door:,Supplying of approved make, powder coated metal double door vertical TPN MCB DB IP 43 protection with provision for MCCB upto160A TP/FP 36kA as incomer and space for SP/TP MCBs as outgoing (without MCCB/MCBs) inclusive of busbar & connections etc : 6 Way without MCCB |
| 123 | RCBOs: Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz with 10kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification. Four Pole (8 Module) : 4 pole 63Amp, 100/300mA sensitivity |
| 124 | Modular Electronic Fan Regulator : Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as requiredon existing board. 2 Module 100 Watt(2 module) |
| 125 | Earthing with G.I. earth plate 600x600x6 mm: Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required |
| 126 | Add extra for using salt and charcoal/coke for G.I/copper plate (blacksoil) : Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation in hard rock and refilling the pit with black soil. |
| 127 | 25x5 mm G.I. strip: Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required. |
| 128 | Telephone cable, 0.5 mm PVC insulated cu. Conductor : Supplying and drawing following pair, 0.5 mm PVC insulated copper conductor unarmouredtelephone cable in existing surface/concealed, steel/PVC conduit as required.: Telephone wire 0.5 mm, 2 Pair |
| 129 | RJ-11 telephone jack modular : Supply, fixing and testing of RJ 11 telephone jack modular (1 Module) |
| 130 | XLPE insulated power cable, al. conductor: Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor, 3½ core armoured, 95 sq. mm |
| 131 | Cable Laying: Laying of one number armoured / unarmoured power cable1.1.KVgrade of size exceeding 25sq. mm but not exceeding120 sq.mmdirect in ground includingexcavation inall soil/murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required. |
| 132 | Cable Gland, Brass compression gland: Gland for P.V.C. insulated armoured cable, Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, rubber ring complete erected with cable and lead connection etc. as per specification complete. Gland size 38 mm 3½ x 70 sq. mm, 3x95 sq. mm |
| 133 | Crimping type alum. lugs: Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete. 95 sq. mm |
| 134 | Sub mains in recessed/concealed rigid PVC conduit (HMS) : Wiring for sub-mains with PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.8), 3 1/2 Wire sub main : 3 x 16.0 + 1 x 10.0 sq. mm. cable |
| 135 | Sub mains in recessed/concealed rigid PVC conduit (HMS) : Wiring for sub-mains with PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit (HMS) ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.8), 3 1/2 Wire sub main : 3 x 25.0 + 1 x 16.0 sq. mm. cable |
| 136 | XLPE insulated power cable, al. conductor : Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor, 4 core armoured:,10 sq. mm. |
| 137 | Water tight terminal box (Polycarbonate): Supplying and erection of water tight terminal box made of PC-GFS (polycarbonate),IP 66 /IP 67 (cableentry systems LES) in accordance with IEC 60670-22, resistant to weather influences (UV due to solar radiation, protected against rainwater, temperatureresistant, impact resistant, etc. insulation voltage 1000 V a.c./d.c., wall thickness of the bottom part 2 / 2.7 mm of required size suitable for kit kat/MCB/switch including 2 nos. pole clamp of M.S. flat iron size 32x3mm, nut and bolts, excluding the cost of the kit kat/MCB/Switch, 4 Pole epoxy connector nut & bolt type, 30Amp, 500Volt complete as per specification as mentioned below. 130 x 180 x 77 mm |
| 138 | Cable Laying: Laying, 1:1 KV grade of size not exceeding 25 sq. mm in the existing item. Laying of one number armoured / unarmoured power cable 1:1 KV grade of size not exceeding 25 sq. mm in the existing RCC hume/stone ware/G.I. pipe/ DWC Pipe/ surface in existing trench as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender