Educational and Research Institute Boards / Undertakings / PSU Closing in 10 days TDR #57021575

Tender For Renovation Works Ladies Toilet And Hod Office Toilet Along With Other Allied Work At The Department Of Environmental Studies And Replacement Of Defective Switchboards, Electrical Fittings, Wiring And Ceiling Fans In The Faculty Of Science,

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
9.88 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
10 days left
EMD
19776
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Works Ladies Toilet And Hod Office Toilet Along With Other Allied Work At The Department Of Environmental Studies And Replacement Of Defective Switchboards, Electrical Fittings, Wiring And Ceiling Fans In The Faculty Of Science, University Of Delhi

BOQ

Name of Work:- Renovation works Ladies Toilet and HOD Office Toilet along with other allied work at the Department of Environmental Studies and Replacement of defective Switchboards, Electrical Fittings, Wiring and Ceiling fans in the Faculty of Science, University of Delhi
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
23 x 2.5 sq.mm
33 x 4 sq.mm
43 x 6 sq.mm
56 x 6 sq.mm
6Supplying and fixing following size/modules GI box along with modular base and cover plate for modular switches in recess etc as reqd.
76 Module (200mmX75mm)
88 Module (125mmX125mm)
912 Module (200mmX150mm)
10Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
115/6 amps switch
123 pin 5/6 amps socket outlet
1315 /16 amps switch
146 pin 15/16 amp socket outlet
15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with cable sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
16Group C
17Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections, painting etc. as required.
18Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
19Group C
20Supplying and fixing of Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2125 mm dia
22Supplying and fixing 2 module stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd.
23Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
244 X 10 sq. mm + 2 X 6 sq. mm earth wire
25Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
26Brush Less Direct Current (BLDC) Fan without Remote 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
27Supply and fixing of suitable size G.I. box with modular plate and cover on front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.as required.
28Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
2912 way (4 + 36), Double door
30Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of single pole MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
31Single pole
32Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. asrequired.
33Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
34100 amps
35Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
363.5c X 120 sq. mm
37Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, refilling the trench etc as required.
38Upto 35 sqmm
39Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
404 X 16 sq. mm (28mm)
41Supply, Installation, testing and commissioning of pre-wired, double box type fitting with two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
42Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm
43Dismantling of ceiling fan/exhaust fan/Light fittings etc. including disconnection of wires/cable and submission of same in department store etc. complete as required.
44S/F snap-in DLP trunking of 105 mm X 50 mm with suitable cover on the existing wall/ surface i/c having all the accessories such as flat angle, end caps, internal/ external angle etc. as required at site.
45Supply, Installation,testing and comissioning of 15 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required
46Detection of fault in LT underground cable of all size with FLC Machine which includes pin pointing of fault, disconnection of cable from both end complete as required.
47For First Fault
48supply of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of following size etc. as required.
494c x 16 sqmm
50Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57021575
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 9.88 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Delhi University
Work Description Tender for Renovation Works Ladies Toilet And Hod Office Toilet Along With Other Allied Work At The Department Of Environmental Studies And Replacement Of Defective Switchboards, Electrical Fittings, Wiring And Ceiling Fans In The Faculty Of Science, University Of Delhi
Basic Detail
Tender No CEET-373
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 14 Aug 2026
Submission Date 24 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 9.88 Lakhs
Tender Fee 500
EMD 19776
Exemption Not Available
Document List
d0fe9f0e-60aa-4077-bb1d-21346fb71aa0.html
Tendernotice_1.pdf
BOQ_969009.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

d0fe9f0e-60aa-4077-bb1d-21346fb71aa0.html

pdf

Tendernotice_1.pdf

xls

BOQ_969009.xls

Disclaimer