Public Administrative Department Local Bodies Closing in 16 days TDR #57020660

Tender For Remodelling Of Existing Pump House For Sludge Drain & Construction Of Stp For Supplying Treated Water To Various Parks In Sunder Nagri & Adjoining Areas.

Issued by Local Bodies · Delhi, Delhi
Tender Value
6.74 Crore
Estimated cost
Bid Submission
31 Aug 2026
16 days left
EMD
13.49 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Remodelling Of Existing Pump House For Sludge Drain & Construction Of Stp For Supplying Treated Water To Various Parks In Sunder Nagri & Adjoining Areas.

BOQ

Name of Work:- Remodelling of existing pump house for sludge drain & construction of STP for supplying treated water to various parks in Sunder Nagri & adjoining areas.
Sl. No. Item Description
1SITC of Mechanical Coarse Screen with conveyer suitable for preliminary treatment of sewage complete in all respects, including frame, screen bars, drive mechanism, fasteners, supports, and accessories.Channel Size: Suitable for channel size 3.5 m (L) × 0.7 m (W) × 1.0 m SWD Clear Bar Spacing: 20 mm opening & 10mm Bar thickness Drive System: Motor-driven with gearbox and chain/sprocket arrangementPower Consumption: 1.1 KWMotor Protection: IP55 or higherMaterial of Construction (MOC):Screen Bars & Wetted Parts: SS 304 / SS 316Frame & Structural Parts: SS 304 / SS 316
2SITC of Manual Coarse Screen suitable for preliminary treatment of sewage complete in all respects, including frame, screen bars,, fasteners, supports, and accessories.Channel Size: Suitable for channel size 3.5 m (L) × 0.7 m (W) × 1.0 m SWD Clear Bar Spacing: 20 mm opening & 10mm Bar thickness Material of Construction (MOC):Screen Bars & Wetted Parts: SS 304 / SS 316Frame & Structural Parts: SS 304 / SS 316
3SITC of Electrical Horizontal Centrifugal pump set with Non clog/mf impeller to handle storm/mixed/sewage water with CI/SS-304/ CI epoxy Impeller, EN8 shaft, SS Sleeve, Min. discharge 631.88m3/hr. at head rang 11-15 Mtr, (suction 250 mm & delivery size 250)mm duly coupled with Minimum 50 HP Energy Efficient BEE Model Electric motor mounted on a common base frame coupled and coupling gaurd etc. complete as required.
4Providing & fixing of Auto Transformer Starter 50 HP (without oil) confirming to ISS pacification, taping provided from 40%,60% and 80% of line voltage, fitted with fixed and moving contact of ETP grade Copper to provide long life, fitted with 3 magnetic overload relay of dash pot type adjustable from full load to twice of full load, earthing terminal is provided, suitable for places where motor starting load is high etc complete as required.
5P & F of MS Black Pipe (9.5 mm thickness ) conforming to IS:3589 with required nuts bolts & paking sheet etc complete as required of diameter 600 mm (Gr.330),
6P & F of MS Black Pipe (9.5 mm thickness ) conforming to IS:3589 with required nuts bolts & paking sheet etc complete as required of diameter 300 mm (Gr.330)
7Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 300 mm dia (wall thickness 7 mm)
8SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/mixed/ sewage water having minimum Discharge of 40 m3/hr at Head-15 Mtrs, RPM 1450 RPM (syn) having suction and delivery size 80 mm dia. mounted on a common base frame coupled with Min. 5 HP or suitable rating three phase, 415 volt, 50 Hz supply electrical Motor complete as required. M.O.C. as Casing- CI/SS-304/CI epoxy, Impeller- CI/SS-304 / CI epoxy , Shaft- 40C8 complete with coupling, coupling guard and foundation bolts.
9SITC of 8\\" x 10\\" pump set coupled with air cooled 1500 rpm minimum 32 BHP bhp engine, with following specifications:-1.Engine Type: Diesel Engine.2. Base Frame Material: Mild Steel3. Impeller, body, casing cover: cast iron4. shaft sleeve: Stainless steel5. Battery with leads: 12 V, 150 AH,6. Discharge: 500 m³/hr at 10 m head7. Pump: 8\\" x 10\\" horizontal centrifugal end suction pump. complete with all requisite accessories like fuel tank, etc. suitable to handle storm/ mixed/sewage water complete as required
10SITC of providing fixing of MS enlarger /expander/reducess 200 X 300 mm, 10.00 mm thick, o.5 m length, at site with suitable size nut bolt , packing sheet etc. MOC-MS, Double Flange, 500 mm length
11Providing & fixing of MS Bend with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 600 mm (10 mm thick) length 01 m
12Providing & fixing of MS Blind Flange with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 600 mm ( 25mm thickness)
13Providing & fixing of MS Flange with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 600 mm ( 25mm thickness)
14Providing &fixing of MS Bend with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 300 mm (10 mm thick) length 0.75 m
15Providing &fixing of MS Flange with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 300 mm ( 25mm thickness)
16Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : of 300 mm dia
17Providing , Fixing , testing & commissioning of non rising spindle sluice valve of CI body with wedge bronze ring confirming to ISI 6603 marked complete PN 1.6 complete as required. (a) SV 600 mm
18.Providing , Fixing , testing & commissioning of non rising spindle sluice valve of CI body with wedge bronze ring confirming to ISI 6603 marked complete PN 1.6 complete as required. 300 mm Dia.
19Providing and fixing of MS Platfrom made out of MS Girder size 8''x4\\" (200x100mm) fixing in back side and center supporting with MS angle iron size 50x50x6 mm with cross welding and fixing of MS chequred sheet of 7mm thickness on top side of MS platform back side of platform duly welded MS railing with 2'' dia MS pipe with 3'6'' height to be fixed at site. Complete plate and railing duly painted with enamel paints.
20Supply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 200 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. andconsisting of the followings:(A) Diesel Engine:Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level (C) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer(E) FUELTANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications &accessories as required as per specifications. (F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitablenumbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cableconnection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. (I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG setcomplete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, powerfactor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2.Auto/Manual/Test/Off selector switch3.Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P10 accuracy for protection and 15 VAclass-I for metering5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA (Phase & Total), Frequency, KWH, PF.6.LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments.8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and currentadjustment.9. Main supply failure monitor.10. Supply failure timer.11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failureto start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the ope
21Supply,Installation, testing and commissioning of Main LT PANEL (MLTP) power distribution board made out of 1.6 mm sheet steel, epoxy powder coated , specially designed Al bus bar 400A to 630A with heat shrinkcable colour coated sleeves suitable for accommodating MCCBs/MCBs /Isolators as incoming and outgoing as required (without MCCBs/MCBs/Isolators ) complete with digital meter module, including Voltmeter Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required ( Conforms to IS:8623)400A, FP , 36 KA Microprocessore based.- 1 noR, Y, B Phase Indicating Lamp, 240V AC-3 nosON/OFF/TRIP Indicating Lamp, 240V AC-03 nosMulti Function Meter (MFM).-01 no.400/5A 5VA Resin Cast CL: 1 Ring Type Current Transformer For MFM.-03 nos.Surge Suppressor, type B+C with suitable back up Protection.01 no.6A SP 10kA C Curve MCB-06 nos.CT-Disconnector Terminals & Neutral Links-07 nos.INCOMING -1-1 AUTOMATIC PHASE REVERSAL SYSTEM (FOR DESU)-01 nos400A, FP , 36 KA ATS-01 noAutomatic PhaseSequence Relay : Microprocessor-based, 3-Phase (3P4W) with reverse phase, phase loss, under/overvoltage protection.-01 noAuxilary Contractors-04 nos.Intelligent Controller/PLC: For automatic the switchgear sequence based on relay input.-01 noBusbars: Electrolytic grade Copper/Aluminium Busbars rated for 400A, duly insulated with heat Shrinkable Sleeves.-03 nos.INCOMING -2 (For-DG)-01 no400A, FP,36 KA Microprocessore based-01 noR,Y,B Phase Indicating lamp,240 AC-03 nosON/OFF/TRIP Indicating Lamp, 240V AC-03 nosMulti Function Meter (MFM).-01 nos400/5A 5VA Resin Cast CL: 1 Ring Type Current Transformer For MFM.-03 nos6A SP 10kA C Curve MCB-06 nosCT-Disconnector Terminals & Neutral Links-07 nosAUTO TRANSFER SWITCH ATS 400 A,4 POLE-01 nos400A,FP, ATS-01 noON/OFF Indicating Lamp, 240V AC-02 nos6A SP 10kA C Curve MCB-02 nosOUTGOING FEEDERS160A MCCB160A,36 KA TPN MCCB Thermal Magnetic Base Rel. Prot.-06 nos100A MCCB100A TP+N MCCB.-04 nos63A MCB63A FP MCB.-04 nos40A MCB40A FP MCB.-04 nosMiscellaneous Item.-1 setEnclosure 2/1.6mm CRCA for Extention Panel with Cubical type, Single Front, Fixed Type, Floor Mounting-Lot 400 A, TPN Aluminium Bus Bar.-lotCopper PVC Control Wire, Power Wire, Ferul Numbers, Cable Ties, Tie Base, complete as above-lotHardware Nuts, Bolts, Washers, Panel Lock, I-Hooks, Insulators, etc.-lot
22STP PANELSupply,Installation, testing and commissioning of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated , specially designed Al bus bar 400A to 630A with heat shrinkcable colour coated sleeves suitable for accommodating MCCBs/MCBs /Isolators as incoming and outgoing as required (without MCCBs/MCBs/Isolators ) complete with digital meter module, including Voltmeter Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required ( Conforms to IS:8623)INCOMER-01 no100A TP+N MCCB Thermal Magnetic Base Rel. Prot.-01 noR, Y, B Phase Indicating Lamp, 240V AC-03 nosON/OFF/TRIP Indicating Lamp, 240V AC-03 nosMulti Function Meter (MFM).-01 no100/5A 5VA Resin Cast CL: 1 Ring Type Current Transformer For MFM.-03 nos6A SP 10kA C Curve MCB-06 nosCT-Disconnector Terminals & Neutral Links-07 nosEarth Bus Bar across the width of Aluminium 25 X 6 mm.-01 nosOUTGOING FEEDERS63A TP MCCB with Thermal Magnetic Base Rel. Prot and 7.5 KW Star Delta Starter (Aspirator Aeration Tanks).-02 nos25A TP MCB with Thermal Magnetic Base Rel. Prot and 4.5 KW DOL Starter.-02 nos25A TP MCB with Thermal Magnetic Base Rel. Prot and 2.2 KW DOL Starter.-02 nos16A TP MCB with Thermal Magnetic Base Rel. Prot and 1.5 KW DOL Starter.-02 nos10A TP MCB with Thermal Magnetic Base Rel. Prot and 1.1 KW DOL Starter.-09 nos10A TP MCB with Thermal Magnetic Base Rel. Prot and 0.75 KW DOL Starter.-08 nos10A TP MCB with Thermal Magnetic Base Rel. Prot and 0.55 KW DOL Starter.-08 nos10A TP MCB with Thermal Magnetic Base Rel. Prot and 0.37 KW DOL Starter.-08 nos40A FP MCB.-02 nos32A FP MCB.-02 nos32A DP MCB.-02 nosMiscellaneous Item.-1 setEnclosure 2/1.6mm CRCA for Extention Panel with Cubical type, Single Front, Fixed Type, Floor Mounting-Lot200A, TPN Aluminium Bus Bar.-LotCopper PVC Control Wire, Power Wire, Ferul Numbers, Cable Ties, Tie Base, complete as above-LotHardware Nuts, Bolts, Washers, Panel Lock, I-Hooks, Insulators, etc.-Lot
234 Way TPN DBSupply, Installation, testing and commissioning TPN MCB DB and comprising of the following, Incoming63A 4P MCB with all connected accessories – 1 Set. as incomerOutgoing16A, DP MCB - 4 NosWith necessary COPPER interconnections.LIGHTING 4 way TPN DB
24Supply,Installation, testing and commissioning of power distribution board APFC Panel 60 KVAR .INCOMER-01 160A,36 KA TPN MCCB Thermal Magnetic Base Rel. Prot.-01 noR, Y, B Phase Indicating Lamp, 240V AC-03 nosON/OFF/TRIP Indicating Lamp, 240V AC-03 nosMulti Function Meter (MFM).-01 no160/5A 5VA Resin Cast CL: 1 Ring Type Current Transformer For MFM.-03 nosMicro Processor based 8 stage Automatic Power Factor Correction Relay with digital Power Factor Meter.-01 nosAuxilliary Contactor with Add on Contact ( 4NO + 4NC )-02 nosAuto / Manual Selector Switch (1P-2W)-01 no6A SP 10kA C Curve MCB-07 nosCT-Disconnector Terminals & Neutral Links-04 nosEarth Bus Bar across the width of Aluminium 50 x 10 mm.-01 noOutgoing Feeders25 kVAr Capacitor Bank-01 no63A TP MCB 01 noON/OFF Indicating Lamp, 240V AC-02 nosStart/Stop Push Buttons with Aux. Contact-02 nos25 KVAR Capacitor Duty Contactor. -01 no25 KVAr Heavy Duty Capacitor Bank-01 no6A SP 10kA C Curve MCB-04 nosCT-Disconnector Terminals & Neutral Links-04 nos10 kVAr Capacitor Bank-02 nos32A TP MCB-02 nosON/OFF Indicating Lamp, 240V AC-04 nosStart/Stop Push Buttons with Aux. Contact-04 nos10 KVAR Capacitor Duty Contactor.-02 nos10 KVAr Heavy Duty Capacitor Bank-02 nos6A SP 10kA C Curve MCB-04 nosCT-Disconnector Terminals & Neutral Links-04 nos5 kVAr Capacitor Bank-02 nos16A TP MCB-02 nosON/OFF Indicating Lamp, 240V AC-04 nosStart/Stop Push Buttons with Aux. Contact-04 nos5 KVAR Capacitor Duty Contactor.-02 nos5 KVAr Heavy Duty Capacitor Bank-02 nos6A SP 10kA C Curve MCB-04 nosCT-Disconnector Terminals & Neutral Links-04 nos3 kVAr Capacitor Bank-01no10A TP MCB-01 noON/OFF Indicating Lamp, 240V AC-02 nosStart/Stop Push Buttons with Aux. Contact-02 nos3 KVAR Capacitor Duty Contactor.-01 3 KVAr Heavy Duty Capacitor Bank-016A SP 10kA C Curve MCB-04CT-Disconnector Terminals & Neutral Links-042 kVAr Capacitor Bank-0110A TP MCB-01ON/OFF Indicating Lamp, 240V AC-02Start/Stop Push Buttons with Aux. Contact-022 KVAR Capacitor Duty Contactor. -012 KVAr Heavy Duty Capacitor Bank-016A SP 10kA C Curve MCB-04CT-Disconnector Terminals & Neutral Links-04Miscellaneous Item.-1 SetEnclosure 2/1.6mm CRCA for Extention Panel with Cubical type, Single Front, Fixed Type, Floor Mounting-Lot200A, TPN Aluminium Bus Bar.-LotCopper PVC Control Wire, Power Wire, Ferul Numbers, Cable Ties, Tie Base, complete as above-LotHardware Nuts, Bolts, Washers, Panel Lock, I-Hooks, Insulators, etc.-Lot
25Supplying, Installation, testing and commissioning of earth pit of minimum dia. 150 mm size 3 mtr. Deep in hard rock soil, through machine or by any suitable means.Earth electrode consisting of 3 mtr. Long and 80 mm Dia. Size G.I electrode surrounded by highly conductive black fill compound chemical 2 bags (25 kg each) with necessary masonry encloser for 300 mm x 300 mm size GI earth pit cover complete as required.
26Supplying, Installation, testing and commissioning of earth pit of minimum dia. 100 mm size 3 mtr. Deep in hard rock soil, through machine or by any suitable means.Earth electrode consisting of 3 mtr. Long and 50 mm Dia. Size Pure copper earth electrode surrounded by highly conductive black fill compound chemical 2 bags (25 kg each) with necessary masonry encloser for 300 mm x 300 mm size GI earth pit cover complete as required.
27Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -3.5 C *240 sq mm
28Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -3.5 C *70 sq mm
29Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -3.5 C *50 sq mm
30Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -3 C *70 sq mm
31Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -4 C *6 sq mm
32Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -4 C * 10sq mm
33Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
34Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
35Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
36Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re- filling etc. as required.
37Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
38Supply and installation following size of perforated pre-painted M.S cable trays with perforation not more than 17.5% in conveninet sections, jointed with connectors , suspended from the ceiling with M.S suspenders including bolts nuts, painteing suspenders etc as required .300 mm width x 50mm depth X 1.6 mm thickness.
39Supply and installation following size of perforated pre-painted M.S cable trays with perforation not more than 17.5% in conveninet sections, jointed with connectors , suspended from the ceiling with M.S suspenders including bolts nuts, painteing suspenders etc as required .150 mm width x 50mm depth X 1.6 mm thickness.
40Supply and installation following size of perforated pre-painted M.S cable trays with perforation not more than 17.5% in conveninet sections, jointed with connectors , suspended from the ceiling with M.S suspenders including bolts nuts, painteing suspenders etc as required .100 mm width x 50mm depth X 1.6 mm thickness.
41Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 240 sq. mm(62 mm)
42Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required .3x70 sq. mm.
43Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 70 sq. mm (38mm)
44Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 50sq. mm (35mm)
45Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
46Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
47Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
48Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, & Ccurve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
49Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
50Supply and fixing following rating, double pole 240 V , isolator in the existing MCB DB complete with connections, testing and Commissioning etc. as required.63 A
51Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply,earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
52Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
53Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clammped with 1mm thick saddle).
54Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
55Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
56Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6; 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. asrequired.
57Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
58Supply of 380 mm (15 inch) sweep 1400 rpm exhaust fan fresh Air Type comlete with shutter blades etc. as required.
59Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
60Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 8 way, Double door
61(b) 6 way , Double door
62(c) 12 Way , Double door
63P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
64LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, I , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100 watt
65LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm) 18- 22 watt
66Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
67Providing and fixing of 4.5 KG CO2 type fire extinguisher sqeeze grip type, trolly wheel as well mounting type complete in all respect with ISI mark i/c fixing arrangement etc as required.
68Providing and fixing ABC (Aluminium Phosphate) power type fire extinguisher of 6kgs capacity complete in all respect with isi mark i/c fixing arrangement etc as required.
69Supply and fabrication of pole protection system made up 8SWG steel wire mesh of size 25mmX75mm rectangular with 50mmX50mmX6mm MS angle iron for supporting the mesh i/c MV Danger plate and grounding the protection system in
70Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
71Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
72Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
73Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
74SITC of 3mm (Min) ACP sheet based acrylic raised letters LED Board with 1\\" x1\\" M.S square pipe box type frame , pipe frame all open sides covered by G.I Sheet preperly
75SITC of 50mmX50mmX6mm angle iron mounting stand for ACP sign board and painting with primer and finished paint as required.
76Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
77Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelCold twisted bars
78Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelCold twisted bars
79SITC of Raw Sewage Transfer Pumps (Type-2) suitable for transferring raw sewage from inlet sump to downstream treatment units, complete with pump, motor, base frame, coupling, coupling guard, fasteners, and all accessoriesPump Type: Centrifugal Pump – SubmerssibleService: Raw Sewage TransferCapacity: 20.83 m³/hr (each pump)Total Number of Pumps: 2 Nos. Head: 15 m (approx.) Suction / Delivery Line Size: individual line 400 mm and common header line 700 mm Motor: TEFC squirrel cage induction motorPower Consumption: 1.1 KW EachMaterial of Construction (MOC):Pump Casing: SS-304 / CI epoxy coated Impeller: SS-304 / CI epoxy coatedShaft: SS-304SealingArrangement: Mechanical seal suitable for raw sewage applicationMounting: Common base frame with anti-vibration pads
80SITC of Mechanical Fine Screen with conveyer suitable for preliminary treatment of sewage complete in all respects, including frame, screen bars, drive mechanism, fasteners, supports, and accessories.Channel Size: Suitable for channel size 2.0 m (L) × 0.4 m (W) × 0.7 m SWD Clear Bar Spacing: 20 mm opening & 10mm Bar thickness Drive System: Motor-driven with gearbox and chain/sprocket arrangementPower Consumption: 1.1 KWMotor Protection: IP55 or higherMaterial of Construction (MOC):Screen Bars & Wetted Parts: SS 304 / SS 316Frame & Structural Parts: SS 304 / SS 316
81SITC of Manual Fine Screen suitable for preliminary screening of raw sewage at inlet channel, complete with frame, screen bars, lifting hooks, supports, and all necessary accessoriesChannel Size: Suitable for channel size 2.0 m (L) × 0.4 m (W) × 0.7 m SWDClear Bar Spacing: 6 mm opening & 2 mm Bar thicknessOperating Mode: Manual rakingMaterial of Construction (MOC):Screen Bars & Wetted Parts: SS 304 / SS 316Frame & Supporting Members: SS 304 / SS 316
82SITC of oil skimmer mechanism suitable for preliminary oil & grease removal of raw sewage at inlet channel, complete with skimmer assembly, frame, lifting hooks, supports, anchor bolts, fasteners, and all necessary accessories Material of Construction (MOC):Skimmer Assembly & Wetted Parts: SS-304 / SS-316Frame & Supporting Structure: SS-304 / SS-316 / MS epoxy coated.Size of Unit :2.4 m x 1.5 m x 1.0 m SWD + 0.50 FB; No. of Units : 1 No.Power Consumption: 1.1 KW
83SITC of mechanical grit unit suitable for removal of grit and heavy inorganic particles from raw sewage during preliminary treatment, complete with grit removal mechanism, drive arrangement, frame, supports, anchor bolts, fasteners, and all necessary accessories,Application: Preliminary Treatment – Grit RemovalUnit Size: 0.8 m (L) × 0.8 m (W) × 0.6 m LDGrit Contact & Wetted Parts: SS-304 / SS-316Power Consumption: 2.2 KW EachFrame & Supporting Structure: SS / MS epoxy coated, suitable for sewage envionment
84SITC of Parshall flume complete with ultrasonic non-contact flow meter suitable for measurement of raw sewage flow at inlet channel, including flume section, ultrasonic sensor, transmitter, mounting supports, cabling, fasteners and all necessary accessoriesOverall length 3.0 m; Channel width 1.0 m; Throat width 0.152 m; Water depth 0.5 m SWD + 0.5 m FBParshall Flume with Ultrasonic Flow MeterFlume body: RCC / FRP / SS; Meter housing & wetted parts: SS / corrosion-resistant material
85SITC of submersible mixers suitable for mixing and homogenisation of sewage in equalisation tank, complete with submersible motor, mixer assembly, guide rail arrangement, lifting chain, mounting accessories, anchor bolts, fasteners and all necessary fittingsTank capacity: 172.374 m³Submersible MixerPower Consumption: 4.5 KW EachMixer body, shaft & wetted parts: SS-304 / SS-316No.2
86SITC of submersible mixers suitable for mixing and homogenisation of sewage in equalisation tank, complete with submersible motor, mixer assembly, guide rail arrangement, lifting chain, mounting accessories, anchor bolts, fasteners and all necessary fittingsTank capacity: 21.55 m³Submersible MixerPower Consumption: 0.37 KW EachMixer body, shaft & wetted parts: SS-304 / SS-316No.2
87SITC, filling and commissioning of MBBR bio media suitable for biological treatment in MBBR Tank-1 and Tank-2, including required quantity of media with specific surface area 2500–3000 m²/m³, complete with all accessories, as per approved drawings and datasheet.Tank capacity: 11.191 m³ (each tank)MBBR Bio MediaMedia material: HDPE / equivalent; 2 No. of Tank.
88SITC of internal recirculation pumps suitable for process liquid recirculation, complete with pump, motor, base frame, coupling, coupling guard, anchor bolts, fasteners and all necessary accessories.6 m³/hr, 10 m (approx.)Power Consumption: 0.55 KW EachProgressive Cavity Pump / Rotary Lobe PumpAs per vendor designPump casing: CI epoxy coated / SS-304; Rotor/Screw: SS-304 / SS-316; Shaft: SS-410 / SS-316
89SITC of submersible pumps suitable for return activated sludge recirculation, complete with submersible motor, guide rails, lifting chain, mounting accessories and all fittings.33 m³/hr, 10 m (approx.)Power Consumption: 2.2 KW EachSubmersible PumpAs per vendor designWetted parts: SS-316 / SS-304No. 2
90SITC of blower suitable for aeration in STP / process tanks, complete with blower assembly, drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories.90 Nm³/hr, 8 m (approx.)Power Consumption: 1.1 KW EachTwin-Lobe / Tri-Lobe / CentrifugalAs per vendor designBlower casing/housing: DI – EN-GJS-400 / SG Iron; Shaft: SS-410 / SS-420 / SS-316; Impeller/rotor: DI / Aluminium AlloyNo. 3
91SITC of tube settler media suitable for solid-liquid separation in sedimentation / clarifier tanks, complete with media supports and necessary accessories, as per approved drawings and datasheet.4.5 m³Chevron type, black coloured mediaNot applicableHigh-density polymer / corrosion-resistant plastic;
92SITC of pumps suitable for sludge transfer, complete with drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories, as per approved drawings and datasheet.1 m³/h, 10 m (approx.)Power Consumption: 0.37 KW EachScrew Type / Progressive Cavity Pump / Rotary Lobe PumpPump casing: CI epoxy coated / SS-304; Rotor/Screw: SS-304 / SS-316; Shaft: SS-410 / SS-316No.2
93SITC of chlorinator units suitable for treated water disinfection, complete with dosing pump, reactor, valves, mounting accessories and all necessary fittings, as per approved drawings and datasheet.0.5 kg/h; Voltage 220–240 V / 50–60 Hz; IP65; Max. 80 psi / 85°C, Chlorinator Unit Reactor: SS 316LNo. 2
94SITC of submersible pumps suitable for Treated Water Transfer Pump, complete with submersible motor, guide rails, lifting chain, mounting accessories and all fittings.26.0 m³/hr, 25 m (approx.) of 3.7 KW power consunmptionSubmersible PumpWetted parts: SS-316 / SS-304No. 2
95SITC of pressure sand filter suitable for water filtration, complete with filter vessel, media support system, valves, piping connections, and all accessories.Dia 1.7 m × 2.0 m SWD + 0.5 m FBPressure Sand FilterVessel: MS / SS / FRP; Internals: SS / PVC / HDPENo.1
96SITC of activated carbon filter suitable for water filtration, complete with filter vessel, media support system, valves, piping connections, and all accessories, as per approved drawings and datasheet.Dia 1.6 m × 2.0 m SWD + 0.5 m FBActivated Carbon FilterNot applicableVessel: MS / SS / FRP; Internals: SS / PVC / HDPENo.1
97SITC of pumps suitable for sludge transfer, complete with drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories, as per approved drawings and datasheet.1 m³/h, 10 m (approx.)Screw Type / Progressive Cavity Pump / Rotary Lobe PumpPump casing: CI epoxy coated / SS-304; Rotor/Screw: SS-304 / SS-316; Shaft: SS-410 / SS-316No.2
98SITC of submersible mixers suitable for mixing and homogenisation of sewage in equalisation tank, complete with submersible motor, mixer assembly, guide rail arrangement, lifting chain, mounting accessories, anchor bolts, fasteners and all necessary fittingsTank capacity: 2.90 m³Power Consumption: 0.37 KW EachSubmersible MixerMixer body, shaft & wetted parts: SS-304 / SS-316No.2
99SITC of pumps suitable for sludge transfer, complete with drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories, as per approved drawings and datasheet.1.1 m³/h, 10 m (approx.)Power Consumption: 0.37 KW EachScrew Type / Progressive Cavity Pump / Rotary Lobe PumpPump casing: CI epoxy coated / SS-304; Rotor/Screw: SS-304 / SS-316; Shaft: SS-410 / SS-316No.2
100SITC of filter press suitable for sludge dewatering, complete with filter press unit, gearbox, drive system, fabricated base frame, panels, accessories, and all necessary fittings.1.1 m³/hFilter PressAs per vendor design; RPM 100Wetted parts: SS-304 / SS-316; Base: Fabricated; Gearbox make: SEW / Bonfiglioli / Equivalent;No.2
101SITC of DWPE Dosing System suitable for increasing sludge concentration prior to the dewatering unit, complete with dosing pump, gearbox, drive system, fabricated base frame, control panel, all accessories, and necessary fittings for complete and efficient operation.DWPE Dosing System,Capacity of Pump15 LPH quantity: 3 Nos.Power Requirement:PP Head & PVC FittingsFor sludge concentration improvement in dewatering unit
102SITC of dosing tank of MOC: MSEP/HDPE (High Density Polyethylene)/PP/FRP (Fiber Reinforced Plastic)
103SITC of submersible mixers suitable for mixing and homogenisation of sewage in equalisation tank, complete with submersible motor, mixer assembly, guide rail arrangement, lifting chain, mounting accessories, anchor bolts, fasteners and all necessary fittingsTank capacity: 0.2 m³Submersible MixerMixer body, shaft & wetted parts: SS-304 / SS-316No.2
104SITC of Centrate Transfer Pumps (Type-1) suitable for transferring to sump to treatment units, complete with pump, motor, base frame, coupling, coupling guard, fasteners, and all accessoriesPump Type: Centrifugal Pump – HorizontalService:Centrate Transfer PumpCapacity: 1.10 m³/hr (each pump)Total Number of Pumps: 2 Nos.Head: 15 m (approx.)Suction / Delivery Line Size: individual line 400 mm and common header line 700 mmMotor: TEFC squirrel cage induction motorPower Consumption: 1.1 KW EachMaterial of Construction (MOC):Pump Casing: SS-304 / CI epoxy coatedImpeller: SS-304 / CI epoxy coatedShaft: SS-304Sealing Arrangement: Mechanical seal suitable for raw sewage applicationMounting: Common base frame with anti-vibration pads
105SITC of submersible pumps suitable for Treated Water Transfer Pump, complete with submersible motor, guide rails, lifting chain, mounting accessories and all fittings.21 .0 m³/hr, 25 m (approx.) of 3.7 KW power consunmptionSubmersible PumpWetted parts: SS-316 / SS-304No. 2
106SITC of blower suitable for aeration in STP / process tanks, complete with blower assembly, drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories.240 Nm³/hr, 8 m (approx.)Power Consumption: 1.1 KW EachTwin-Lobe / Tri-Lobe / CentrifugalBlower casing/housing: DI – EN-GJS-400 / SG Iron; Shaft: SS-410 / SS-420 / SS-316; Impeller/rotor: DI / Aluminium AlloyNo. 3
107SITC of Backwash Pumps 33 .0 m³/hr, 15 m (approx.) of 3.7 suitable for transferring to sump to treatment units, complete with pump, motor, base frame, coupling, coupling guard, fasteners, and all accessoriesPump Type: Centrifugal Pump – Horizontal pumps
108SITC of UV disinfection system suitable for treated water disinfection, complete with UV reactor, lamps, power SITC/ballast, mounting supports, piping connections and all necessary accessories.21.55 m³/hUV Disinfection SystemPower Consumption: 1.1 KW EachAs per vendor design; Voltage 220–240 V / 50–60 Hz, IP65No. 1
109SITC of Programmable Logic Controller (PLC) panel, CPU (Siemens/Allen Bradley or equivalent), I/O modules, power supply, HMI (10\\"), enclosed in IP55 panel.Designation Description Make Qty 1 CPU1 FX5U;CPU Mitsubishi 1 2 BH1 Header Module Mitsubishi 1 3 DI1-11 Digital IO Module Mitsubishi 11 4 DO1-3 Digital IO Module Mitsubishi 3 5 AI1-AI3 Analog IO Module Mitsubishi 3 6 AO1,2 Analog IO Module Mitsubishi 2 7 BEM1 System Module Mitsubishi 1 8 ETHSW1 Unmanaged Ethernet Switch-Din Rail Mountable Phoenix 1 9 CMN-CBL Ethernet Communication Cable EEPL Std. 2 10 P Control Panel With Two Mounting Plates, Front & Rear Door ith A Size Drawing Pocket EEPL Std. 1 11 L1 Red Colour LED Indication Lamp L&T 1 12 L2 Red Colour LED Indication Lamp L&T 1 13 F1-F2 Fan-6 Inch Clasiair 2 14 F1-F2 Metal Finger Guard Clasiair 2 15 FILTER Filter-6 Inch,RAL-7035 Elettro 4 16 DLS1,2 Door Limit Switch With Plastic Protective Cover Kaycee 2 17 TL1,2 Tube Light-LED(Cisa Battern) Sturlite 2 18 Q2.1 MCB(SB202 M-C25) ABB 1 Page | 12 19 Q2.1A MCB(SB202 M-C10) ABB 1 20 Q2.2,2.3, 2.1A,2A MCB(SB202 M-C6) ABB 4 21 Q2.4,2.5 MCB(SB202 M-C4) ABB 2 22 PS1 Power Supply-Din Rail Mounting Multispan 1 23 RLB1-RLB10 8 Channel Relay Board,PC24D08-CNB-SO2 Phoenix 10 24 SKT1 Universal Power Socket EEPL Std.. 1 25 EB Earth Bolt EEPL Std. 2 26 PE Panel Earth (Copper) EEPL Std. 1 27 SE System Earth (Copper) EEPL Std. 1 28 BB1,BB2 24VDC/0VDC BusBars (Copper) EEPL Std. 2 29 XFTB Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 2 30 XFTB 5x20mm Miniature Glass Fuse Links Protectron 2 31 230VAC,0VAC Normal Terminal Block-TB 2.5 EI Phoenix 10 32 XDI,XDI-11 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 65 33 XDI,XDI-11 Normal Terminal Block-TB 2.5 EI Phoenix 208 34 XDI,XDI-11 5x20mm Miniature Glass Fuse Links Protectron 65 35 XDO-10 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 80 36 XDO-10 Normal Terminal Block-TB 2.5 EI Phoenix 80 37 XDO-10 5x20mm Miniature Glass Fuse Links Protectron 80 38 XAI-3 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 48 39 XAI-3 Normal Terminal Block-TB 2.5 EI Phoenix 48 40 XAI-3 5x20mm Miniature Glass Fuse Links Protectron 24 41 XAI-3 5x20mm Miniature Glass Fuse Links Protectron 24 42 XAO Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 8 43 XAO Normal Terminal Block-TB 2.5 EI Phoenix 16 44 XAO 5x20mm Miniature Glass Fuse Links Protectron 8 45 XPTB1,2 Normal Terminal Block-TB 10 EI Phoenix 6 46 EP Normal Terminal Block End Plate-D-TB 2.5 E Phoenix 23 47 EP Fuse Terminal Block End Plate-D-TB 4-HESI EI Phoenix 13 48 EP Normal Terminal Block End Plate-D-TB 4/10 E Phoenix 2 49 CBL Internal Cables Polycab 1 Lot 50 ACC Accessories EEPL Std. 1 Lot 51 SW Cimplicity Server Standard Runtime GE 1 52 PC Personal Computer With Windows11 Professional 64 Bit With USB Type Keyboard & Mouse HP/Dell 1 53 MON LED Monitor 21” HP/Dell 1 54 UPS 1kVA Online UPS APC/Eq 1 55 PR Printer-A3 Size BKW HP/Eq 1Designation Description Make Qty 1 CPU1 FX5U;CPU Mitsubishi 1 2 BH1 Header Module Mitsubishi 1 3 DI1-11 Digital IO Module Mitsubishi 11 4 DO1-3 Digital IO Module Mitsubishi 3 5 AI1-AI3 Analog IO Module Mitsubishi 3 6 AO1,2 Analog IO Module Mitsubishi 2 7 BEM1 System Module Mitsubishi 1 8 ETHSW1 Unmanaged Ethernet Switch-Din Rail Mountable Phoenix 1 9 CMN-CBL Ethernet Communication Cable EEPL Std. 2 10 P Control Panel With Two Mounting Plates, Front & Rear Door ith A Size Drawing Pocket EEPL Std. 1 11 L1 Red Colour LED Indication Lamp L&T 1 12 L2 Red Colour LED Indication Lamp L&T 1 13 F1-F2 Fan-6 Inch Clasiair 2 14 F1-F2 Metal Finger Guard Clasiair 2 15 FILTER Filter-6 Inch,RAL-7035 Elettro 4 16 DLS1,2 Door Limit Switch With Plastic Protective Cover Kaycee 2 17 TL1,2 Tube Light-LED(Cisa Battern) Sturlite 2 18 Q2.1 MCB(SB202 M-C25) ABB 1 Page | 12 19 Q2.1A MCB(SB202 M-C10) ABB 1 20 Q2.2,2.3, 2.1A,2A MCB(SB202 M-C6) ABB 4 21 Q2.4,2.5 MCB(SB202 M-C4) ABB 2 22 PS1 Power Supply-Din Rail Mounting Multispan 1 23 RLB1-RLB10 8 Channel Relay Board,PC24D08-CNB-SO2 Phoenix 10 24 SKT1 Universal Power Socket EEPL Std.. 1 25 EB Earth Bolt EEPL Std. 2 26 PE Panel Earth (Copper) EEPL Std. 1 27 SE System Earth (Copper) EEPL Std. 1 28 BB1,BB2 24VDC/0VDC BusBars (Copper) EEPL Std. 2 29 XFTB Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 2 30 XFTB 5x20mm Miniature Glass Fuse Links Protectron 2 31 230VAC,0VAC Normal Terminal Block-TB 2.5 EI Phoenix 10 32 XDI,XDI-11 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 65 33 XDI,XDI-11 Normal Terminal Block-TB 2.5 EI Phoenix 208 34 XDI,XDI-11 5x20mm Miniature Glass Fuse Links Protectron 65 35 XDO-10 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 80 36 XDO-10 Normal Terminal Block-TB 2.5 EI Phoenix 80 37 XDO-10 5x20mm Miniature Glass Fuse Links Protectron 80 38 XAI-3 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 48 39 XAI-3 Normal Terminal Block-TB 2.5 EI Phoenix 48 40 XAI-3 5x20mm Miniature Glass Fuse Links Protectron 24 41 XAI-3 5x20mm Miniature Glass Fuse Links Protectron 24 42 XAO Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 8 43 XAO Normal Terminal Block-TB 2.5 EI Phoenix 16 44 XAO 5x20mm Miniature Glass Fuse Links Protectron 8 45 XPTB1,2 Normal Terminal Block-TB 10 EI Phoenix 6 46 EP Normal Terminal Block End Plate-D-TB 2.5 E Phoenix 23 47 EP Fuse Terminal Block End Plate-D-TB 4-HESI EI Phoenix 13 48 EP Normal Terminal Block End Plate-D-TB 4/10 E Phoenix 2 49 CBL Internal Cables Polycab 1 Lot 50 ACC Accessories EEPL Std. 1 Lot 51 SW Cimplicity Server Standard Runtime GE 1 52 PC Personal Computer With Windows11 Professional 64 Bit With USB Type Keyboard & Mouse HP/Dell 1 53 MON LED Monitor 21” HP/Dell 1 54 UPS 1kVA Online UPS APC/Eq 1 55 PR Printer-A3 Size BKW HP/Eq 141 XAI-3 5x20mm Miniature Glass Fuse Links Protectron 24 42 XAO Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 8 43 XAO Normal Terminal Block-TB 2.5 EI Phoenix 16 44 XAO 5x20mm Miniature Glass Fuse Links Protectron 8 45 XPTB1,2 Normal Terminal Block-TB 10 EI Phoenix 6 46 EP Normal Terminal Block End Plate-D-TB 2.5 E Phoenix 23 47 EP Fuse Terminal Block End Plate-D-TB 4-HESI EI Phoenix 13 48 EP Normal Terminal Block End Plate-D-TB 4/10 E Phoenix 2 49 CBL Internal Cables Polycab 1 Lot 50 ACC Accessories EEPL Std. 1 Lot 51 SW Cimplicity Server Standard Runtime GE 1 52 PC Personal Computer With Windows11 Professional 64 Bit With USB Type Keyboard & Mouse HP/Dell 1 53 MON LED Monitor 21” HP/Dell 1 54 UPS 1kVA Online UPS APC/Eq 1 55 PR Printer-A3 Size BKW HP/Eq 1
110SITC of instrumentation for the STP, complete with all fittings, accessories, control panels, mounting arrangements, and necessary components for proper and reliable operation. Pressure (Bourdon Type)
111Pressure (Bourdon Type)
112Level Controller( Ultrasonic type) (Treatment Unit)
113DO Analyzer Online (AERATION TANK, anoxic)
114MLSS Analyzer (AERATION TANK, anoxic)
115Online Monitoring System (Inlet Outlet Parameter (pH, BOD, COD, TSS))
116Water Level Indicator (Treatment Unit)
117Differential Level Transmitter (Mechanical Screens)
118Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil
119Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
120By Mechanical Transport including loading,unloading and stacking:- Earth (5 km)
121Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineerin-Charge.(Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completionof the work).
122Dismantling manually/ by mechanical means including stacking ofserviceable material and disposal of unserviceable material within50 metres lead as per direction of Engineer-in-charge : 15.43.2 bituminous road
123Providing and laying S&S Centrifugally Cast (Spun) / Ductile IronPipes conforming to IS : 8329100 mm dia ductile Iron class k-7 pipes
124Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket :100mm Dia.Pipes
125Providing and laying D.I specials of class K-12 suitable for push-on jointing as per IS:9523Upto 600mm dia.
126Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) :100 mm dia Ductile Iron Double Flanged
127Providing flanged joints to double flanged C.I./D.I. pipes and specials,including testing of joints: 100 mm Dimeter Pipe
128Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 100 mm Dia
129Providing and fixing brass stop cock of approved quality :20 mm nominal bore
130Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 100 mm Dia
131Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
132Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar
133Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) : From brick work in cement mortar
134Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work.
135Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below
136Of area beyond 3 sq. metres
137Carriage of materials by Mechanical Transport including loading, unloading and stacking of Earth:- (Note:- Rate shall be applicable for net quantity after deduction of prescribed rate of voids ) Building Rubbish, Lime, Moorum (Lead 5 Km)
138Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to50 m and lift up to 1.5 m.2.28.1 All kinds of soil
139Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.2.6.1 All kinds of soil
140Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.4.20.1 All works upto plinth level 4.20.1.3 Concrete of M20 grade with minimum cement content of 270 kg /cum
141Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.1 All works upto plinth level5.33.1.1 Concrete of M25 grade with content of 330 kg /cum minimum cement
142Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.1 All works upto plinth level5.33.1.2 Concrete of M30 grade with content of 350 kg /cum minimum cement
143Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.2 All works above plinth level upto floor V level5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum
144Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.2 All works above plinth level upto floor V level5.33.2.2 Concrete of M30 grade with minimum cement content of 350 kg /cum
145Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
146Columns, Pillars, Piers, Abutments, Posts and Struts
147Suspended floors, roofs, landings, balconies and access platform
148Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
149Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
150Carriage of earth upto 5 km
151Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
152Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
153Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoringprojections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design
154Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : 22.4.1 Serrated with central bulb (225 mm wide, 8-11 mm thick)
155Providing and fixing in position precast R.C.C. manholecover and frame. 19.19.2.2 Circular shape 500mm internal diameter
156Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in theproportion of 1:2 (1 cement : 2 fine sand) including testing of jointsetc. complete :
157Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement: 6 coarse sand):6.3.1 With F.P.S.(non modular) bricks
15812 mm cement plaster finished with a floating coat of neat cement of mix (1:4)
159Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:- Cement Mortar 1:6 (1 cement : 6 coarse sand)
160Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. - Pre-laminated particle board with decorative lamination on both sides
161Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body. - Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm & above) x (55 mm & above) (Height above 1.8m).
162Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
163Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
164Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge
165Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
16615 mm cement plaster on rough side of single or half brick wall finished (1:4)with a floating coat of neat cement of mix :
167Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
168Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
169Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
170Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
171Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
172White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
173Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x 250 mm
174Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 25 mm nominal dia Pipes
1751:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
176Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.4.20.1All works upto plinth level 4.20.1.2 Concrete of M15 grade with minimum cement content of 240 kg /cum
177Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level --1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
178Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to f loor five level, excluding cost of centering, shuttering, finishing and reinforcement : -1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
179Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement :- Concrete of M25 grade with minimum cement content of 300 kg /cum Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57020660
AUTHORITY Local Bodies
TENDER VALUE 6.74 Crore
LAST DATE 31-08-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Remodelling Of Existing Pump House For Sludge Drain & Construction Of Stp For Supplying Treated Water To Various Parks In Sunder Nagri & Adjoining Areas.
Basic Detail
Tender No EE(E)-I/Sh.N/MCD/26-27/TC-19/1
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 14 Aug 2026
Submission Date 31 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 6.74 Crore
Tender Fee 5900
EMD 13.49 Lakhs
Exemption Not Available
Document List
ac39f3d6-2b3d-4b7d-97a5-e8eeef226cd9.html
BOQ_335660.xls
Circular_1.pdf
Condition.pdf
GCC2024.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

ac39f3d6-2b3d-4b7d-97a5-e8eeef226cd9.html

xls

BOQ_335660.xls

pdf

Circular_1.pdf

pdf

Condition.pdf

pdf

GCC2024.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders