Tender For Maintenance Of Drinking Water Supply Schemes In North Tripura District Under Nrdwp/Rws/Ffc Fund During The Year 2026-27 / Sh:- Providing & Fixing In/C Repair Of Electrical Panel Board Comprising With Starter, Main Switch, Motor Protection
Tender Overview
Project Description
Tender for Maintenance Of Drinking Water Supply Schemes In North Tripura District Under Nrdwp/Rws/Ffc Fund During The Year 2026-27 / Sh:- Providing & Fixing In/C Repair Of Electrical Panel Board Comprising With Starter, Main Switch, Motor Protection Device Etc In Different Water Supply Scheme Within The Jurisdiction Of Laljuri Rd Block Under Dws Sub-Division Kanchanpur.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fitting fixing of 3 pole Power contactor Type 415 V, 50 Hz (L&T make) as per direction of the Engineer-in-charge.i) ML 2 |
| 2 | Providing and fitting fixing Bimetal overload relay type ML series L&T make as per direction of the Engineer-in-charge. |
| 3 | i) 20-32 Amp |
| 4 | ii) 28-42 Amp |
| 5 | Providing and fitting fixing standard operating coil for 415 V, 50 Hz, L&T make as per direction of the Engineer-in-Charge.i) ML 2 |
| 6 | Providing and fitting fixing 3 phase indicating lamp fiitedwith panel board with three different colour lamps with battenholder complete as per specification and direction of theEngineer-in-charge. |
| 7 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 8 | Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 9 | Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge.i) 16 sqmm |
| 10 | Providing and fitting fixing with PVC insulated 3 core flatCopper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge. |
| 11 | i) 2.50 sqmm |
| 12 | ii) 4.0 sqmm |
| 13 | iii) 6.0 sqm |
| 14 | iv) 10.0 sqm |
| 15 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-in-charge. |
| 16 | i) 63 amps |
| 17 | ii) 100 amps |
| 18 | iii) 200 amps |
| 19 | Providing and fitting fixing of single phasing preventer cum selectable over voltage and under voltage relay device complete with required 2.50sqm copper wire including trial run as per direction of the Engg-in-charge |
| 20 | Repairing of existing L&T make FASD Starter by poviding and fitting fixing of necessary spare contact kit (in/c spare coil), replacement of damaged connection wire in the starter, testing and commissioning etc. as per specification and direction of the Engineer-incharge. |
| 21 | i) ML 1.5 |
| 22 | ii) ML 2 |
| 23 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge. |
| 24 | i) 25 HP/18.5 kw Relay range within 13-21 + 10% |
| 25 | ii) 35 HP/26 kw Relay range within 20-32 + 10% |
| 26 | iii) 50 HP/ 37 kw Relay range within 28-42 + 10% |
| 27 | iv) 75 HP/ 55 kw Relay range within 45-75 + 10% |
| 28 | Providing & installation of 76.00 mtr head water lubricated submerssible pump with 3 Ph , 415 VAC motor with star delta connection along with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required upto the depth of 6.10 mtr (maximum) by GI pipe ( conforming to IS : 1239 medium class ) with tailpiece as required welded with GI flange in/c providing fitting fixing by necessary rubber washer, nuts & bolts, MS safety clamp etc. as per required size and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run as per direction of the Engineer-in-charge (each pump with motor shall consist of stainless steel impeller conforming to relevant BIS code. pump make : Duke/KSB/WPIL/Texmo/CRI ) (Pumpset, cable, G.I. pipe of medium class for column assembly etc. will be supplied by the agency at his cost and for main switch / starter payment will be done separately).ii) 5000 / 7500 GPH capacity with 80 mm dia G.I. pipe and 10 mm thick GI flange |
| 29 | Providing , Installation and commissioning of 139.00 mtr head water lubricated submerssible pump with 3 Ph , 415 V AC motor with star delta connection upto the depth of 6.10 mtr by GI pipe ( conforming to IS : 1239 medium class ) with tailpiece as required welded with GI flange in/c providing fitting fixing by necessary rubber washer, nuts & bolts, MS safety clamp etc. as per required size and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run as per direction of the Engineer-in-charge (pump motor with cable & G.I. pipe of medium class for column assembly will be supplied by the agency at his cost).i) 2500 GPH capacity with 50 mm dia G.I. pipe and 10 mm thick GI flange Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender