Banking and Finance Government Departments Closing in 9 days TDR #57020027

Bids Are invited for Sitc Of Air Conditioner

Issued by Government Departments · Kolkata, West Bengal
Tender Value
11.05 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
9 days left
EMD
9500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
282

Project Description

Bids Are invited for Sitc Of Air Conditioner Sitc Of 1.5 Tr Hi-Wall Split Systems - Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating,Isser Value Minimum Value 5.6 , Sitc Of 2.0 Tr Hi-Wall Split Systems - Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Isser Value Minimum Value 5.6 . , Sitc Of 2.0Tr Cassette Type Split Systems - Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), R-32/R410a/R-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230V, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (Idu To Odu), Copper Power Andcontrol Cable Upto 5.5 Mtr (Idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,Dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/Rotary Compressor With Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (Nabl) Accredited As Per International Electrotechnical Commission (Iec) 17025 Standards/Central Power Research Institute (Cpri)/ Electrical Research And Development Association (Erda)With Original Equipment Manufacturer (Oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Isser Value Minimum Value 5.6 . , Sitc Of 3.0Tr Cassette Type Split Systems - Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), R-32/R410a/R-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230V, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (Idu To Odu), Copper Power Andcontrol Cable Upto 5.5 Mtr (Idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,Dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/Rotary Compressor With Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is 1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (Nabl) Accredited As Per International Electrotechnical Commission (Iec) 17025 Standards/Central Power Research Institute (Cpri)/ Electrical Research And Development Association (Erda)With Original Equipment Manufacturer (Oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required.Inverter Type Cooling With 5 Star Bee Rating, Isser Value Minimum Value 5.6 . , Copper Refrigerant Piping For 1.5Tr And 2.0Tr Hi-Wall Split Ac - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split , Copper Refrigerant Piping For 2.0Tr And 3.0Tr Cassette Type Split Units - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units , Drain Pipe - Supply And Fixing Of Duly Insulated 25Mm Upvc Drain Pipe , Outdoor Stand For 1.5Tr And 2.0 Tr Hi-Wall Split Ac - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-Wall Split Ac. , Outdoor Stand For 2.0Tr And 3.0 Tr Cassette Type Split Units - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units. , 4 Inch Dia Pvc Pipe - Supply ,Installation Of Minimum 4 Inch Dia Heavy Duty Pvc Pipe With All Hanging Supports Required At Regular Intervals For Laying Copper And Drain Piping In Banking , Supply And Laying Of Suitable Flexible Cable From Outdoor To Indoor - Supply And Fixing Of Four Core Cable , Dismantling Of Old Air Conditioning - Dismantling Of Existing Air Conditioner

BOQ

Sl. No. Item TitleItem Description
1SITC OF 1.5 TR HI-WALL SPLIT SYSTEMSSupplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating,ISSER value minimum value 5.6
2SITC OF 2.0 TR HI-WALL SPLIT SYSTEMSSupplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS - 1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). Inverter Type Cooling with 5 Star BEE Rating, ISSER value minimum value 5.6 .
3SITC OF 2.0TR CASSETTE TYPE SPLIT SYSTEMSSupplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power andcontrol cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS -1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS 1391 as required. Inverter Type Cooling with 5 Star BEE Rating , ISSER value minimum value 5.6 .
4SITC OF 3.0TR CASSETTE TYPE SPLIT SYSTEMSSupplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power andcontrol cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS 1391 as required.Inverter Type Cooling with 5 Star BEE Rating, ISSER value minimum value 5.6 .
5COPPER REFRIGERANT PIPING for 1.5TR AND 2.0TR HI-WALL SPLIT ACSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1.5 TR HI - WALL SPLIT
6COPPER REFRIGERANT PIPING for 2.0TR AND 3.0TR CASSETTE TYPE SPLIT UNITSSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 2.0 and 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 2.0 TR CASSETTE TYPE SPLIT UNITS
7DRAIN PIPESupply and fixing of duly insulated 25mm UPVC drain pipe
8OUTDOOR STAND for 1.5TR AND 2.0 TR HI-WALL SPLIT ACSupplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1.5 TR Hi-Wall Split AC.
9OUTDOOR STAND for 2.0TR AND 3.0 TR CASSETTE TYPE SPLIT UNITSSupplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 2.0 TR CASSETTE TYPE SPLIT UNITS.
104 INCH DIA PVC PIPESupply ,Installation of minimum 4 inch dia heavy duty PVC pipe with all hanging supports required at regular intervals for laying copper and drain piping in banking
11SUPPLY AND LAYING OF SUITABLE FLEXIBLE CABLE FROM OUTDOOR TO INDOORSupply and fixing of four core cable
12DISMANTLING OF OLD AIR CONDITIONINGDismantling of existing air conditioner

AI Tender Summary

OUR REF NO 57020027
AUTHORITY Government Departments
TENDER VALUE 11.05 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name State Bank Of India
Work Description Bids Are invited for Sitc Of Air Conditioner Sitc Of 1.5 Tr Hi-Wall Split Systems - Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating,Isser Value Minimum Value 5.6 , Sitc Of 2.0 Tr Hi-Wall Split Systems - Supplying , Installation, Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant Wireless Remote Control, Suitable For Working Between 180- 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100% Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Complete As Per Cpwd Specification And Is - 1391 Part Ii 2023. The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature). Inverter Type Cooling With 5 Star Bee Rating, Isser Value Minimum Value 5.6 . , Sitc Of 2.0Tr Cassette Type Split Systems - Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), R-32/R410a/R-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230V, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (Idu To Odu), Copper Power Andcontrol Cable Upto 5.5 Mtr (Idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,Dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/Rotary Compressor With Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is -1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (Nabl) Accredited As Per International Electrotechnical Commission (Iec) 17025 Standards/Central Power Research Institute (Cpri)/ Electrical Research And Development Association (Erda)With Original Equipment Manufacturer (Oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required. Inverter Type Cooling With 5 Star Bee Rating , Isser Value Minimum Value 5.6 . , Sitc Of 3.0Tr Cassette Type Split Systems - Supplying, Installation, Testing And Commissioning Of Air Cooled Cassette Type Air Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), R-32/R410a/R-407 Green Refrigerant, Wireless Remote, Inbuilt Drain Pump, Suitable For 400/230V, 50 Hz ,1 /3 Phase Ac Supply, Including Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 5.5 Mtr (Idu To Odu), Copper Power Andcontrol Cable Upto 5.5 Mtr (Idu To Odu) Including Drain Pipe, The System Shall Be Capable Of Performing Cooling,Dehumidification, Air Circulation, Filteration & Ventilation Of Following Capacity With Scroll/Rotary Compressor With Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb) As Specified. The System Shall Be Able To Deliver 100% Of The Rated Capacity As Per Relevant Is Code. The Lab Testing Reports As Per Is 1391 Shall Be Submitted From National Accreditation Board For Testing And Calibration Laboratories (Nabl) Accredited As Per International Electrotechnical Commission (Iec) 17025 Standards/Central Power Research Institute (Cpri)/ Electrical Research And Development Association (Erda)With Original Equipment Manufacturer (Oem) Etc. Complete As Per Cpwd Specification And As Per Is 1391 As Required.Inverter Type Cooling With 5 Star Bee Rating, Isser Value Minimum Value 5.6 . , Copper Refrigerant Piping For 1.5Tr And 2.0Tr Hi-Wall Split Ac - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 1.5 Tr Hi - Wall Split , Copper Refrigerant Piping For 2.0Tr And 3.0Tr Cassette Type Split Units - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, All Accessoriesas Per Specifications Etc. As Required 9.5 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 2.0 And 15.86 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 2.0 Tr Cassette Type Split Units , Drain Pipe - Supply And Fixing Of Duly Insulated 25Mm Upvc Drain Pipe , Outdoor Stand For 1.5Tr And 2.0 Tr Hi-Wall Split Ac - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1.5 Tr Hi-Wall Split Ac. , Outdoor Stand For 2.0Tr And 3.0 Tr Cassette Type Split Units - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 2.0 Tr Cassette Type Split Units. , 4 Inch Dia Pvc Pipe - Supply ,Installation Of Minimum 4 Inch Dia Heavy Duty Pvc Pipe With All Hanging Supports Required At Regular Intervals For Laying Copper And Drain Piping In Banking , Supply And Laying Of Suitable Flexible Cable From Outdoor To Indoor - Supply And Fixing Of Four Core Cable , Dismantling Of Old Air Conditioning - Dismantling Of Existing Air Conditioner
Basic Detail
Tender No GEM/2026/B/7919044
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 14 Aug 2026
Submission Date 24 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 11.05 Lakhs
Tender Fee Ref. Documents
EMD 9500
Exemption Not Available
Document List
31f125f5-c91c-4491-b0e2-453ee9bf59e5.pdf
9757658_Boq_1.xlsx
hatibagan_ac_nit_2026-08-14-13-33-36_4615128f9196ce690932b367d1d8a10b.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

31f125f5-c91c-4491-b0e2-453ee9bf59e5.pdf

xlsx

9757658_Boq_1.xlsx

pdf

hatibagan_ac_nit_2026-08-14-13-33-36_4615128f9196ce690932b367d1d8a10b.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders