Tender For Special Repairs To Leaky Roof, Damaged Flooring, Walls, Ceiling, Partition, Toilet, Processing Room And Other Repair Works In Tissue Bank Building In King Institute Of Preventive Medicine And Research, Guindy, Chennai-32.
Tender Overview
Project Description
Tender for Special Repairs To Leaky Roof, Damaged Flooring, Walls, Ceiling, Partition, Toilet, Processing Room And Other Repair Works In Tissue Bank Building In King Institute Of Preventive Medicine And Research, Guindy, Chennai-32.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling, clearing away and carefully stacking materials use ful for re-use for any thickness of Pressed tiles and weathering course etc.complete and as directed by the departmental officers. |
| 2 | Dismantling, plain cement concrete and clearing away the same from the site and roughening the surface etc., complete complying with standard specification and as directed by the departmental officers. |
| 3 | Dismantling the damaged ceiling old Thatched Roof including tying materials into small bundles and clearing away etc., complete complying with standard specification and as directed by the departmental officer. |
| 4 | Dismantling, clearing away and carefully stacking materials use ful for re-use for any thickness of A.C Sheet with out timbers etc.complete and as directed by the departmental officers. |
| 5 | Dismantling, clean removal of old damaged peeled off cement plaster 12mm deep per Sqm, clearing away and carefully stacking materials use ful for re-use for any thickness of etc.complete and as directed by the departmental officers. |
| 6 | Dismantling the damaged floor finish and dadooing walls in cement mortar with mosaic tiles / Glazed tiles / cuddapah slab and clearing away with carefully stacking the material useful for re-use for any thickness etc., complete complying with standard specification and as directed by the departmental officer. |
| 7 | Dismantling the damaged doors and windows including removal of frames, hinges, fastenings and clearing away etc. complete complying with standard specification and as directed by the departmental officers. |
| 8 | Providing two legged scaffolding using 48.30mm dia heavy duty MS pipe over all height of 3.00m the distance between 2 legs being 1.25m and the spacing of the post being 2m in each rows and providing platform with C.W. planks using 40mm thick silver oak and 1.00m wide in complete form with horizontal bracings @ 1.50m c/c vertical direction and with cross bracings using same 48.30mm dia including cutting, threading assembly with red oxide primer, labour charges cost of specials such on large plate, shoe, carcher, coupling, bolt and nut transportation charges. The bottom of vertical post shall rest on 300x300x70mm 1:2:4 concrete base etc complete complying with standard specification and as directed by the departmental officers. |
| 9 | Initial height of 3.00m |
| 10 | Add every additional height of 2.50m |
| 11 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means |
| 12 | Relaying with brick jelly lime concrete 1:2:5 (one lime, two sand, five brick jelly using 20mm brick jelly for foundation etc. including dewatering if found necessary and laid in layer of not more than 15 cm thick compacting etc. complete as per standard specification and as directed by the departmental officers. |
| 13 | Rectification of columns, beams, slabs, brick work and sunshade by dismantling and chipping distressed portion removing the rusted reinforcement by using wire brush and by sand blasting cleaning, compressed air and water washing, applying anti corrosive inhibitor coating at the rate of 1.20kg/m2 over the affected area as per specification given by the manufacturing guniting with cement mortar 1:3 (one of cement and three of P-sand) to an average thickness of 40mm under required pressure and then neatly finishing including hire charges for guniting machineries and all tools and plants, labour charges, fuel charges including all leads for portable with water including curing 7 days and all other incidental charges etc. complete. |
| 14 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used, hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. |
| 15 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 16 | Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre 'T'. The 'T' shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of 'T' section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of 'T' section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile 'L' Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look. |
| 17 | Supplying and fixing new one in position of Hilux board false ceiling using 10.00mm thick of approved quality and design suspended from the ceiling using 'U' shaped galvanized iron channel of size 25x25x0.55mm thick at 1.20m centre on both longitudinal and cross direction for vertical support and fixing 'U' shaped G.I channel of size 50x30x 0.55mm thick at 0.90m centre to centre on longitudinal direction respectively for horizontal support by using T.W reapers at corners & at intermediately fixing of plaster of parries on the panel provided as per design /pattern given by the site officer & finishing the ceiling surface with same plaster of pairs materials etc. Necessary openings should be covered with Acrylic panel complying with std. specification and as directed by the departmental officers etc. complete cost including all materials such as Rawl plugs, bolts and nuts, G.I pipes, metal star screws paper tape, jointing components etc, complete. All the materials should be got approved before use on work by the Executive Engineer. |
| 18 | Paving the top of roof with new Solar Reflective Ceramic Tiles of required design of size (12\\"x12\\") 305 x 305 x 7mm thick of approved make over base layer of cement mortar 1:3,(One cement and three sand) 12mm thick and laid straight alignment and pointed neatly with tiles and cement in ratio 1:3 with epoxy packing for joints laid without any air gap in the tiles neatly and fixing in position as per standard specification and as directed by the departmental officers. The colour and quality of tiles should be got approved by the Executive Engineer before use on work. |
| 19 | Paving the floor with best quality vitrified Tiles of size 600x600mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 20 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 21 | Repaving the flooring with ceramic tiles of size 305x305x6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 22 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 23 | Dadooing with Double Charged vitrified tiles of size 600mm x 600mm x 8mm. |
| 24 | Dadooing with printed design colour glazed tiles of size 300 x 600 x 10mm |
| 25 | Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm |
| 26 | Supplying and fixing with new country wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. |
| 27 | Supplying and fixing Solid Core Flush Shutters with teakply on both side withteakwook lipping alround 35mm thick with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm), 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf. |
| 28 | Renewing the broken glass panes of 3mm. Thick with new plain glass panes of 3mm. Thick including fixation in position with teak wood beeding of size 35mm x 12mm alround the glass panels with nails etc.,. |
| 29 | Supplying, fabricating and fixing inposition Aluminium anodized powder coated of any colour matt finish glazed fixed partition of size 1.50m x 1.30m using 63.50x38.10x2mm @1.127 kg/m Alu.section at 900mm C/C in vertical direction and 1300mm @ C/C at horizontal direction with necessary rubber beadings Alu. clips, of size 17.27x17.15x1.40mm@ 0.175 kg/m and using 4mm thick plain glass including cost of all materilas, labours, power consumptions required for fabrications, drilling holes in RCC column, slab, masonry walls wherever necessary with powerdrills to the required extent and make good to the original condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers. All the aluminium sections are to be anodised with matt finish under electrically controlled conditions in accordance with IS 1868/1962 for an avereage abiduc film thickness of 15 microns etc. complete. |
| 30 | Fabricating Supplying and fixing in position of Aluminium anodized powder coated of any colour matt finish of single leaf fully glazed Door shutters with 5.50 mm thick glass. The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section with Vertical & Top rail: [email protected] kg/m, Bottom rail: 100x44.45x2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/mAlu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/mAlu. Handle: 100x30mm @ 0.988 kg/m and necessary accessories such as Alu. clips rubber beading, full length of handles on both sides, lock, furniture fittings such as, Hinges, Automatic door closer, rubber bush, stopper including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the reuired extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc. complete complying with standard specification and as directed by the deparmental officers. All the Alu. Section are to be anodised with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., complete. |
| 31 | Supply & fixing of WPC door with Frame : Wood Plastic Composite Door with density of 900kg/cum and it is water proof and termite proof. It is premium WPC door with complete aesthetic door of natural look with polished surface finish The rate is inclusive of labour, fixing charges and material charges and transporting charges complete complying with standard specification and as directed by the departmental officers. |
| 32 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work. |
| 33 | Renewing and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) |
| 34 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 35 | Renewing and fixing new one of PVC Nahini trap of size 100mmx75mm with best PVC gratting of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (one of lime, two of sand, 5 of 40mm size brick jelly) and finished with cement mortar 1:3 (one cement and three sand) including dismantling masonry works wherever found necessary and making good the damaged portions to the original condition and giving connections to cast iron pipe as directed etc., complete complying with standard specification and as directed by the departmental officers (The PVC Nahini trap should be got approved by the Executive Engineer before use of work). |
| 36 | Renewing and fixing in position best quality PVC soil / waste pipes of following sizes having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 37 | 110mm dia PVC soil pipe |
| 38 | 75mm dia PVC soil pipe |
| 39 | Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level. |
| 40 | 20mm dia UPVC pipe |
| 41 | 25mm dia UPVC pipe |
| 42 | 40mm dia UPVC pipe |
| 43 | Supplying and fixing new one of first quality and approved variety of ball valve with ISI mark of size 25mm dia including cost of shellac, thread, labour charges for cutting, threading of G.I pipes etc., complete complying with standard specification for both internal and external water supply arrangements. |
| 44 | Supplying and fixing with new following PVC and UPVC Specials in water supply arrangements (both in internal and external water supply arrangements Since the labour for cutting, threading / pasting, sundries have already been included under pipe line item of works, no separate provision for fixing PVC specials needs to be allowed |
| 45 | 50mm dia PVC Elbow |
| 46 | 20 mm dia UPVC coupling |
| 47 | 20 mm dia UPVC Elbow |
| 48 | 20 mm dia UPVC Tee |
| 49 | 20 mm x 15mm dia UPVC Elbow |
| 50 | 25mm dia UPVC Tee |
| 51 | 25mm dia UPVC Elbow |
| 52 | 25mm dia UPVC Coupling |
| 53 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 54 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 55 | Supplying and fixing with new one SFRC Manhole cover slab with brackets of size 2'0\\" x 2' 0\\" best quality including fixing the same in position etc., complete complying with standard specification and as directed by the departmental officers. |
| 56 | Supplying and fixing in position with new following taps (heavy type) of approved make confirming to IS specification and quality including cost of shellac, thread, cutting and threading wherever necessary etc. complete complying with standard specification and as directed by the departmental officers.(Tap should be got approved by the Executive Engineer, before use on work) |
| 57 | 15mm dia brass swan neck tap |
| 58 | 15mm dia Brass chromium plated pillar Tap (Heavy type) |
| 59 | 15mm dia CP angle cock tap (Heavy type) |
| 60 | SS Health faucet |
| 61 | 15mm dia brass SD tap |
| 62 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes 110mm dia having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers. |
| 63 | Renewing and fixing with new one of following PVC specials of 110mm dia of best approved quality confirming to ISS and providing leak proof joints including fixing to walls and giving connection to the PVC soil stracks,dismantling the brick masonry /RCC floor of roof slab and redoing the disturbed portion to original condition etc., complete. |
| 64 | 110mm dia PVC door elbow |
| 65 | Supplying and fixing with the new PVC Water tank with all fittings including loading, unloading and lifting the tank to terrace and fixing properly to the existing G.I lines without disturbing the masonry structures etc., complete complying with standard specification and as directed by the departmental officers.(The Capacity of the tank may vary according to the delivery lines as by the officers in charge) |
| 66 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve of 25mm dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 67 | Supply and installation of two-track sliding uPVC windows shall utilize uPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 60mm x 52mm, a shutter of 66mm x 42mm x 50mm, an interlock of 45mm x 36mm, and a glazing bead of 24.5mm x 16mm. All frame, sash, and mullion profiles shall be reinforced, where required, with a 1mm thick GI steel section, and windows are to be equipped with security devices such as touch locks or crescent locks, nylon rollers, and an aluminium track, all compliant with relevant specifications and departmental directives. Glazing shall consist of 5mm thick Plain or Pinhead glass, secured by TPE (Grey) weather-sealed gaskets, while all corners and mullion joints of the frame and sash shall be mitred cut and fusion welded without mechanical joints, with all welded joints neatly trimmed to a grooved nib finish, ensuring sharp- edge-free products. The complete window units shall be fixed into pre-finished openings by drilling and fastening through the outer frame with high- quality fasteners, and silicon sealant shall be applied to fill the gap between the wall and window frame for a leak-proof installation and complete finish etc., Complete and as directed by the department officers. |
| 68 | Repainting the old walls with two coats of first quality Plastic emulsion paint of approved colour including through scrapping preparation of surface and finishing neatly etc., complying with standard specification and as directed by the departmental officers. The colour and quality should be got approved by the Executive Engineer before use. |
| 69 | Repainting Old Plastered Wall Surface with Two finishing coats of ready mixed (Exterior Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 70 | Repainting the old wood works two coats in all floors with best synthetic enamel paint of approved quality colour and brand to be approved by Executive Engineer before use on work, including removal of old paint from wood works, thorough scrapping, preparation of surface, cost of brushes, high scaffolding charges and neat finishing complying with standard specification and as directed by the departmental officers. |
| 71 | Repainting the old iron work surface with two coats in all floors with best synthetic enamel paint of approved quality colour and brand to be approved by Executive Engineer before use on work, including removal of old paint from iron surface with sand paper, scrapping, preparation of surface, cost of brushes, high scaffolding charges and neat finishing complying with standard specification and as directed by the departmental officers. |
| 72 | Collecting the scattered debries from the campus and conveying away the same to outside by lorry to a lead of 3 km.(Entirely within city limit) including loading charges and dumping in low places and levelling neatly etc. complete. Please Enable Macros to View BoQ information |
| 73 | Collecting the scattered debries from the campus and conveying away the same to outside by lorry to a lead of 3 km.(Entirely within city limit) including loading charges and dumping in low places and levelling neatly etc. complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender