Housing Urban and Rular Development Government Departments Closing in 10 days TDR #57019209

Tender For Electrical Installation Work Of Lift Shaft With Adjacent Lift Corridor Of Northern Building And Data Centre Of Ups Room, Lalbazar Kolkata Police Head Quarter Under Lalbazar Electrical Section.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2026
10 days left
EMD
7946
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Installation Work Of Lift Shaft With Adjacent Lift Corridor Of Northern Building And Data Centre Of Ups Room, Lalbazar Kolkata Police Head Quarter Under Lalbazar Electrical Section.

BOQ

Name of Work:- Electrical Installation work of Lift Shaft with adjacent Lift corridor of Northern Building and Data Centre of UPS room, Lalbazar Kolkata Police Head Quarter under Lalbazar Electrical Section.
Sl. No. Item Description
1Supplying and delivery of 4 core 50 Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.)(Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion]
2Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - Legrand/LK/Havells/Siemens) [D-11/15]
34 way upto 160A
4Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make - Legrand/LK/ Havells/Siemens) [D-8/10]
5100A FP
6Supply and Fixing of spreader link installed in the existing VTPN DB suitable for 4 way upto 160A capacity FP MCCB as per direction of EIC. (Make Legrand/LK/ Havells/ Siemens) [NS]
7Supplying and delivery of 2 core 10 Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.)(Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion] [1.2 cable Portion]
8Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - Legrand/LK/ Havells/ Siemens) [D -9/13]
92+4 way , Double door
102+8 way , Double door
112+12 way , Double door
12Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.(Make Legrand/LK/ Havells/ Siemens) [D-5/6]
1340A DP
14Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make Legrand/LK/ Havells/ Siemens) [D-6/7]
1510-32A SP
1632A TP
1732A FP
1863A TP
19Supplying and delivery of 4 core 16 Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.)(Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion] [1.11 cable portion ]
20Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required. [E-14/1(a)]
212 X 1.5 sq. mm + 1 X 1.5 sq. mm as ECC
222 X 2.5 sq. mm + 1 X 1.5 sq. mm as ECC
232 X 6 sq. mm + 1 X 4 sq. mm as ECC
24Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required. [E-14/1(b)]
254 X 6 sq mm +2 X 4 sq mm as ECC
26Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. [E-24/1(c)]
27Average run 8 mtr
28Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. [E-24/3(a)]
29On Board
30Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S & F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E -18/9(b)]
31Supply and Fixing of 230V 50Hz 10W LED Bulk head (Philips make) as per direction of EIC. [NS]
32Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. [D-14/34(a)]
33200x50x1.25mm (18SWG) with 25x25x3mm angle iron support
34Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. [J - 1/7]
35Supplying and delivery of 4 core 35 Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.) (Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion] (Make - Gloster/RR kabel/Havells/Polycab) [NS]
36Excavation of soil for installation of Earth Electrode and filling & ramming. (For soft soil) [G-1/1(a)]
37Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. (By ISI-Medium GI pipe) [G-1/2(a)]
38Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [G -3/5(d)]
39Supply & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd. [G-2/4(a)]
40Laying of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade on wall surface as required. [F-1/2a,2b,2c]
414 core 50 sq mm
424 core 35 sq mm
434core 16 sq mm
442 core 10 sq mm
45Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD withpowder-coated pressure Die-cast Aluminium with high-transmissionopal PMMA/ polycarbonate/ prismatic diffuser having uniform lightdistribution and construction as per IS : 10322. The driver ratedoutput wattage should be 10% to 15% higher than lamp rating andefficiency Driver >80%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, Operating temp range 00 to 400 C, internal surgeprotection of 2.5 KV with Short & Open circuit protection, THD <10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electricalcircuitary), of minimum 50000 Burning Hours (Life projection shallbe calculated as per TM-21 methodology) and 70% of initial Lumenmaintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K, Maximum power consumption should not more than thespecified rating and Fixture shall be confirming to relevant BISstandards and trade mark certificate (T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housingComplete in all respect and LED Chips of SMD Low to mid-power, asper requirement (LM-80 tested) and necessary inter-connections with1.5 sq mm FR, PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 5 year OEM comprehensiveon-site warranty against manufacturing defects including driver andLED module. All test report except L80 should be from 3rd partyNABL accredited Lab as per BIS shall be submitted. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement.System lumen efficacy shall be as below:System lumen efficacy ≥ 110 lm/Watt,. For 12-15 W [ 1.1.3 LED portion)
46Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [ 3.1 fan portion]
47Fixing of 18\\" ( 450 mm )dia 1420 rpm full metal body & blade wall bracket fan by 4 nos MS fastener, nuts & bolts etc as required incl. S & F 1.5 sq mm flxible cu wire of 0.5 mtr length. [C-4/29]
48Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [F-4/7a,7c]
49For 4 core 50 sq mm
50For 4 core 35 sq mm
51For 4 core 16 sq mm
52For 2 core 10 sq mm
53Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :[ F-5]
54For 4 core 50 sq mm
55For 4 core 35 sq mm
56For 4 core 16 sq mm
57For 2 core 10 sq mm
58Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9]
59For 6 sq mm
60For 4 sq mm
61For 2.5 sq mm
62For 1.5 sq mm
63Supplying and fixing 415V, 415A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Mk. L&T/ Siemens/ Havells/ Standard] [D-3/4a]
64Dismantaling the existing main switch from the wall after dismantaling existing incoming and outgoing cables incl. mending good the damages as per direction of EIC.
65Supplying and delivery of 4 core 240Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.) (Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion]
66Laying of 4 core 240 sq mm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade on wall surface by suitable size MS clamp as required. [F-1/2e]
67Supply & fixing of special type MS angle iron of size 50x5 mm of 1' length with 10mm 4\\" 2 nos fastener for laying of 4 core 240 sq mm cable. [NS]
68Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [F-4/7c] for 240 mm cable.
69Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: [F-5/8b] for 240 sq mm cable
70Supply & fixing of sheet steel (16 SWG) cable end box of size 18\\"x10\\"x6\\" on 250A TPN SFU enclosure with nuts & bolts etc. incl. powder coated painting.
71S & F Lightning conductor Air-terminals made of 15 mm dia 1500mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI(Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate atbottom incl. necessary holes etc. duly grouted on the parapet etc.in CC mortar (4:2:1)(P-J-1/Item-1 )
72Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:(P:J-1/ Item-4)
73Length upto 0.5 Mtr
74Length above 0.5 Mtr
75Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. (P : J-1/Item-7)
76Supply & Fixing of Testing Joints by 25 mm x 6 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as requiredPage :J-2/Item-13)
77Earthing with 50 mm dia( ISI-Medium) GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. Page : G-1/Item-2 a)
78Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For morum soil)(Page : G-1/Item-1b) .
79Connecting the equipments body to earth busbar incl. S & F50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor withGI saddle as required and connection to equipments with incl.drilling holes, bolts, nuts,washers etc.: ( G-3/Item-e.)
80Jointing for Horijontal & vertical run of GI strip through welded joint of (25 x 6) mm or (50 x 6) mm GI Strip to Lap joints/ 'T' joints, etc. and painting the joints with 2 (two) coats of bituminous paint. [NS]
81S & F of 4 SWG GI (Hot Dip) wire on Parapet/Roof/Plinth/Surface of wall for lightning conductor as required (for Horizontalruns) with 40 mm long GI Staples spaced not exceeding 1300mm apart incl. mending good all the damages to the buildingworks ( J-1/2) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57019209
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrical Installation Work Of Lift Shaft With Adjacent Lift Corridor Of Northern Building And Data Centre Of Ups Room, Lalbazar Kolkata Police Head Quarter Under Lalbazar Electrical Section.
Basic Detail
Tender No WBPWD/AE/LBESD/eNIQ-10Q of 26-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 14 Aug 2026
Submission Date 27 Aug 2026
Open Date 01 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 7946
Exemption Not Available
Document List
2911.pdf
3790b273-cc1f-4793-b4fe-80e63e07ef43.html
BOQ_5090061.xls
Notice10.pdf
Tendernotice_1 (20).pdf
Tendernotice_2 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

2911.pdf

html

3790b273-cc1f-4793-b4fe-80e63e07ef43.html

xls

BOQ_5090061.xls

pdf

Notice10.pdf

pdf

Tendernotice_1 (20).pdf

pdf

Tendernotice_2 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders