Tender For Electrical Installation Work Of Lift Shaft With Adjacent Lift Corridor Of Northern Building And Data Centre Of Ups Room, Lalbazar Kolkata Police Head Quarter Under Lalbazar Electrical Section.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2026
10 days left
EMD
7946
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Installation Work Of Lift Shaft With Adjacent Lift Corridor Of Northern Building And Data Centre Of Ups Room, Lalbazar Kolkata Police Head Quarter Under Lalbazar Electrical Section.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and delivery of 4 core 50 Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.)(Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion] |
| 2 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - Legrand/LK/Havells/Siemens) [D-11/15] |
| 3 | 4 way upto 160A |
| 4 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make - Legrand/LK/ Havells/Siemens) [D-8/10] |
| 5 | 100A FP |
| 6 | Supply and Fixing of spreader link installed in the existing VTPN DB suitable for 4 way upto 160A capacity FP MCCB as per direction of EIC. (Make Legrand/LK/ Havells/ Siemens) [NS] |
| 7 | Supplying and delivery of 2 core 10 Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.)(Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion] [1.2 cable Portion] |
| 8 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - Legrand/LK/ Havells/ Siemens) [D -9/13] |
| 9 | 2+4 way , Double door |
| 10 | 2+8 way , Double door |
| 11 | 2+12 way , Double door |
| 12 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.(Make Legrand/LK/ Havells/ Siemens) [D-5/6] |
| 13 | 40A DP |
| 14 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make Legrand/LK/ Havells/ Siemens) [D-6/7] |
| 15 | 10-32A SP |
| 16 | 32A TP |
| 17 | 32A FP |
| 18 | 63A TP |
| 19 | Supplying and delivery of 4 core 16 Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.)(Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion] [1.11 cable portion ] |
| 20 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required. [E-14/1(a)] |
| 21 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm as ECC |
| 22 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm as ECC |
| 23 | 2 X 6 sq. mm + 1 X 4 sq. mm as ECC |
| 24 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required. [E-14/1(b)] |
| 25 | 4 X 6 sq mm +2 X 4 sq mm as ECC |
| 26 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. [E-24/1(c)] |
| 27 | Average run 8 mtr |
| 28 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. [E-24/3(a)] |
| 29 | On Board |
| 30 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S & F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E -18/9(b)] |
| 31 | Supply and Fixing of 230V 50Hz 10W LED Bulk head (Philips make) as per direction of EIC. [NS] |
| 32 | Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. [D-14/34(a)] |
| 33 | 200x50x1.25mm (18SWG) with 25x25x3mm angle iron support |
| 34 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. [J - 1/7] |
| 35 | Supplying and delivery of 4 core 35 Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.) (Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion] (Make - Gloster/RR kabel/Havells/Polycab) [NS] |
| 36 | Excavation of soil for installation of Earth Electrode and filling & ramming. (For soft soil) [G-1/1(a)] |
| 37 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. (By ISI-Medium GI pipe) [G-1/2(a)] |
| 38 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [G -3/5(d)] |
| 39 | Supply & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd. [G-2/4(a)] |
| 40 | Laying of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade on wall surface as required. [F-1/2a,2b,2c] |
| 41 | 4 core 50 sq mm |
| 42 | 4 core 35 sq mm |
| 43 | 4core 16 sq mm |
| 44 | 2 core 10 sq mm |
| 45 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD withpowder-coated pressure Die-cast Aluminium with high-transmissionopal PMMA/ polycarbonate/ prismatic diffuser having uniform lightdistribution and construction as per IS : 10322. The driver ratedoutput wattage should be 10% to 15% higher than lamp rating andefficiency Driver >80%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, Operating temp range 00 to 400 C, internal surgeprotection of 2.5 KV with Short & Open circuit protection, THD <10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electricalcircuitary), of minimum 50000 Burning Hours (Life projection shallbe calculated as per TM-21 methodology) and 70% of initial Lumenmaintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K, Maximum power consumption should not more than thespecified rating and Fixture shall be confirming to relevant BISstandards and trade mark certificate (T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housingComplete in all respect and LED Chips of SMD Low to mid-power, asper requirement (LM-80 tested) and necessary inter-connections with1.5 sq mm FR, PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 5 year OEM comprehensiveon-site warranty against manufacturing defects including driver andLED module. All test report except L80 should be from 3rd partyNABL accredited Lab as per BIS shall be submitted. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement.System lumen efficacy shall be as below:System lumen efficacy ≥ 110 lm/Watt,. For 12-15 W [ 1.1.3 LED portion) |
| 46 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [ 3.1 fan portion] |
| 47 | Fixing of 18\\" ( 450 mm )dia 1420 rpm full metal body & blade wall bracket fan by 4 nos MS fastener, nuts & bolts etc as required incl. S & F 1.5 sq mm flxible cu wire of 0.5 mtr length. [C-4/29] |
| 48 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [F-4/7a,7c] |
| 49 | For 4 core 50 sq mm |
| 50 | For 4 core 35 sq mm |
| 51 | For 4 core 16 sq mm |
| 52 | For 2 core 10 sq mm |
| 53 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :[ F-5] |
| 54 | For 4 core 50 sq mm |
| 55 | For 4 core 35 sq mm |
| 56 | For 4 core 16 sq mm |
| 57 | For 2 core 10 sq mm |
| 58 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9] |
| 59 | For 6 sq mm |
| 60 | For 4 sq mm |
| 61 | For 2.5 sq mm |
| 62 | For 1.5 sq mm |
| 63 | Supplying and fixing 415V, 415A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Mk. L&T/ Siemens/ Havells/ Standard] [D-3/4a] |
| 64 | Dismantaling the existing main switch from the wall after dismantaling existing incoming and outgoing cables incl. mending good the damages as per direction of EIC. |
| 65 | Supplying and delivery of 4 core 240Sq mm Armoured cablesXLPE/PVC insulated are designed for 1.1 kV StrandedAluminium conductor, high tensile galvanized steel wire/striparmour for mechanical protection, and PVC/FR PVC outersheathing power cable of following size.(IS 7098 Part - 1/2011 with Up To Date Amendments.) (Make - Gloster/RR kabel/Havells/Polycab) [1.14 Cable portion] |
| 66 | Laying of 4 core 240 sq mm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade on wall surface by suitable size MS clamp as required. [F-1/2e] |
| 67 | Supply & fixing of special type MS angle iron of size 50x5 mm of 1' length with 10mm 4\\" 2 nos fastener for laying of 4 core 240 sq mm cable. [NS] |
| 68 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [F-4/7c] for 240 mm cable. |
| 69 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: [F-5/8b] for 240 sq mm cable |
| 70 | Supply & fixing of sheet steel (16 SWG) cable end box of size 18\\"x10\\"x6\\" on 250A TPN SFU enclosure with nuts & bolts etc. incl. powder coated painting. |
| 71 | S & F Lightning conductor Air-terminals made of 15 mm dia 1500mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI(Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate atbottom incl. necessary holes etc. duly grouted on the parapet etc.in CC mortar (4:2:1)(P-J-1/Item-1 ) |
| 72 | Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:(P:J-1/ Item-4) |
| 73 | Length upto 0.5 Mtr |
| 74 | Length above 0.5 Mtr |
| 75 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. (P : J-1/Item-7) |
| 76 | Supply & Fixing of Testing Joints by 25 mm x 6 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as requiredPage :J-2/Item-13) |
| 77 | Earthing with 50 mm dia( ISI-Medium) GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. Page : G-1/Item-2 a) |
| 78 | Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For morum soil)(Page : G-1/Item-1b) . |
| 79 | Connecting the equipments body to earth busbar incl. S & F50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor withGI saddle as required and connection to equipments with incl.drilling holes, bolts, nuts,washers etc.: ( G-3/Item-e.) |
| 80 | Jointing for Horijontal & vertical run of GI strip through welded joint of (25 x 6) mm or (50 x 6) mm GI Strip to Lap joints/ 'T' joints, etc. and painting the joints with 2 (two) coats of bituminous paint. [NS] |
| 81 | S & F of 4 SWG GI (Hot Dip) wire on Parapet/Roof/Plinth/Surface of wall for lightning conductor as required (for Horizontalruns) with 40 mm long GI Staples spaced not exceeding 1300mm apart incl. mending good all the damages to the buildingworks ( J-1/2) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents