Tender For Replacement Of New Led Recessed Mounted Fittings In Place Of Old Existing Fittings At Conference Room- I, Main Building, Lalbazar Police Head Quarters Under Lalbazar Electrical Section, Pwd.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2026
12 days left
EMD
2711
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of New Led Recessed Mounted Fittings In Place Of Old Existing Fittings At Conference Room- I, Main Building, Lalbazar Police Head Quarters Under Lalbazar Electrical Section, Pwd.
BOQ
| Sl. No. | Item Description |
| 1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish .Make:KEI/Polycab2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 9 mtr |
| 2 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. Make:RR KABEL/Havells/Polycab |
| 3 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 4 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC |
| 5 | Supply & Fixing 240 V, 6-16 A combo, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make: Legrand (Myrius)) |
| 6 | (Power Point Sep 15A ) |
| 7 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 8 | 8 Module |
| 9 | 12 Module |
| 10 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 11 | Supply & Fixing modular type blank plate. |
| 12 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 13 | 2.5 Sqmm |
| 14 | Supplying, installation, Testing & Commissioning of LED Recessed Down lighter (Round) SMD type of CRCA Sheet Body Thickness ≥ 0.50 mm including trim, with prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 450 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , PF ≥0.9, IP20, CRI >80 , UGR (Unified Glare Rating) < 27, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 900 C).(Make- Crompton /Wipro/PhilipsSystem lumen efficacy shall be as below:110lm/watt |
| 15 | 22 - 24 Watt |
| 16 | Supplying, installation, Testing & Commissioning of LED Recessed Down lighter (round) COB Type of CRCA Sheet Body Thickness ≥ 0.50 mm including trim with Aluminium Reflector and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 450 C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , PF≥0.9, IP20, CRI >80 , UGR (Unified Glare Rating) < 27, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 900 C).(Make- Crompton /Wipro/PhilipsSystem lumen efficacy shall be as below:110lm/watt |
| 17 | 8 - 10 Watt |
| 18 | 12 - 15 Watt |
| 19 | 22 - 24 Watt |
| 20 | Supplying, installation, Testing & Commissioning of LED Recessed Down lighter (square) with powder-coated pressure Die-cast Aluminium/CRCA sheet body withhigh-transmission opal PMMA/ polycarbonate/ prismatic diffuserhaving uniform light distribution and construction as per IS : 10322.The driver rated output wattage should be 10% to 15% higher thanlamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K, Maximum power consumption shouldnot more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screenprinting on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.System lumen efficacy ≥110lm/Watt.(Make- Crompton /Wipro/Philips |
| 21 | 18-20 W |
| 22 | 12-15 W |
| 23 | Supplying, installation, Testing & Commissioning of 45 watt LEDStrip (Length of 5 mtr) of Uncoated Synthetic material and Superior adhesive for easy installation and no. of LED 144 LED/mtr, system lumen efficiency 900 lm/mtr as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and Driver efficiency >80%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range 0 degree to 40 degree C internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.9, IP20, CRI >80, life time (LED,Driver & electrical circuitry), of minimum 40000 Burning Hours (Life projection shall becalculated as per TM-21 methodology) and 70% of initial Lumenmaintained till life ends as per LM80 report, CCT 3000°K / 4000°K /6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, complete in all respect and LED Chips of SMD Low to mid-power, as per required (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. |
| 24 | Color WW (Length of 5 mtr) |
| 25 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Lifeprojection shall be calculated as per TM-21 methodology), CCT5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt)(Make- Crompton /Wipro/Philips |
| 26 | Single fittings along with S/F of 1 no. 18-20 W LED lamp as perspecification. |
| 27 | Twin fittings along with S/F of 2 no. 18-20 W LED lamps as perspecification. |
| 28 | S&F of following 7W LED picture light (Make:Philips,Model- moonglade) |
| 29 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.(Make-EPC,crompton or as per choice of EIC) |
| 30 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor singlecore cable and earthing etc. as required.(Make-EPC-Heavy duty) |
| 31 | Fixing only single/twin fluorescent light fitting suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 32 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. |
| 33 | Supply & Fixing Al louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long).Exhaust fan (9\\") Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender