Tender For Fabrication Of Polyhouse-21 Nos. (Under Scsp)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Sep 2026
12 days left
EMD
27300
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Almora → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Fabrication Of Polyhouse-21 Nos. (Under Scsp)
BOQ
| Sl. No. | Item Description |
| 1 | Specifications of Polyhouse |
| 2 | 1 Place Village: Uderkhani (05 Nos.), District: BageshwarVillage: Lob (04 Nos.), District: BageshwarVillage: Iddadhar (12 Nos.), Block: Thalisan, District: Pauri Garhwal, Uttarakhand2 Area (Dimensions) 5.5 m × 12 m 3 Vertical column 60 mm OD, 2 mm thick. Hot Dip 360 GSM GI.4 Foundation 48 mm OD 1500 mm length 3 mm thick weight 4.20 kgs/mtrs. Grouting of the foundation column with a cement concrete mixture of 1:2:4 using telescopic insertion of column is recommended. A portion of the pipe should be visible above the ground. Pit size 45 cm x 45 cm and 1 m depth. Two hold fasts are to be used in perpendicular direction at 20 cm apart in concrete starting from 20 cm from the base.5 Structure Frame Arch Ø 48 mm, 2 mm thick, Purlin Ø 32 mm 2 mm thick6 Stability of structure All galvanized steel is used and designed as per IS875 standards to take withstand wind speed 120 km /hr7 Vertical column 60 mm OD, 2 mm thick. Hot Dip 360 GSM GI.8 Galvanization Quality Complete structure made of hot dip galvanized steel tubular pipes with a minimum of 360 GSM (with Zinc coated on continuous procedure to meet the quality requirements or equivalent section confirming). BIS standards having wall thickness 2mm9 Column spacing 2 m10 Side Height 1.8 m11 Ridge Height 3.1 m12 Top Ventilation 60 cm width with fixing of 40 mesh insect proof net and a 200 micron UV stabilized polyfilm covering material. Roll up round with a worm gear for manual operation13 Covering Material U.V. stabilized 200 micron multilayer polyfilm conforming to Indian standards (IS 15827:2009) and also having minimum 85% level of transmittance. Fixing of cladding material shall be done between 11.00 AM to 3.00 PM14 Side Ventilation Up to 1.6 m, provided on both sides with 40 mesh Nylon Net (Preferably Nylon)15 Door Single door with two hinge at middle, size 2.1 x 1 m double leaf made in plastic/ FRP (Fibre reinforced plastic) sheets mounted in suitable frame with complete fitting locking facility16 Ante Chamber 1.5 m length attached at entrance17 Foundation 48 mm OD 1500 mm length 3 mm thick weight 4.20 kgs/mtrs. Grouting of the foundation column with a cement concrete mixture of 1:2:4 using telescopic insertion of column is recommended. A portion of the pipe should be visible above the ground. Pit size 45 cm x 45 cm and 1 m depth. Two hold fasts are to be used in perpendicular direction at 20 cm apart in concrete starting from 20 cm from the base.18 Fasteners GI clamps, bolts, nuts, self-tapping screws (High tensile strength and galvanized 120 GCM)19 Insect Net 40 mesh20 Rainwater harvesting Provision of PVC pipe of min. 4” diameter with the lateral and ground support pipe with bend should be made, from gutter to ground for collecting rain water from the roof top. Drainage gutter and end caps tobe provided.21 Certification Testing of both structural and plastic materials used in the greenhouse is necessary prior to installation and at the time of handing over and taking over, to ensure compliance with prescribed quality standards. Such testing shall be conducted by National Test House (NTH), Central Institute of Petrochemicals Engineering & Technology (CIPET), or any other recognized government agency. The manufacturer shall provide the relevant test certificates during prior to the installation.22 Warranty Warranty for 5 years from date of installation for structure excluding net and polyfilm. 3 years warranty for all material and installation defects23 Members should not be welded to one another, but fixed with the nut bolts24 Tender should contain samples of all the products including polyfilm, insect proof net, square tubes, etc. with complete technical specifications.25 The firm should be responsible for all land leveling works and head loading (may be upto 1 km from motor road)26 Products with BIS standards only are accepted27 An stainless steel display plate (2 feet length x 1-foot width) depicting \\"ICAR-VPKAS, Almora\\" with Farmers Name, Village Name, Year of construction etc.\\" written in Hindi shall be displayed (fixed) on the gate of polyhouse28 If required, the Institute may increase or decrease the no. of polyhouses. The institute may issue work orders in splits29 ICAR-VPKAS is to be written on the roof of Polyhouse with the green colored radium tape (Each letter must have 5cm width x 60cm length dimension) Grain Counter (electronic) Option IIArticles to be counted: 0.1 to 18 mm in diameter.Counting Performance Typical values: Approximately 0.5 mm diameter approximately 100,000 units per hour2.0 mm diameter approximately 35,000 units per hourAccuracyLess than1/1000 error rate Counting RangeThe entire size range of the objects should be processed using the same, universally adjustable conveyor bowl. Detection of ObjectsObjects are detected by a very precise and, for the most part dust-insensitive infrared light barrier. It can be cleaned by wiping two surfaces, without dismounting any parts.Removal of Residual SubstancesSmall, unwanted objects in the counting material should be excluded from counting procedure and adjustable sensitivity of the parts sensor should be thereConstruction:The Dimensions should not be more than: W x D x H: 250 x 350 x 200mm approximatley and Weight should be about 10-15kgPower Supply: 230 volts ± 10%Software for counting storage and weighing should be provided.- All parameters, results or settings can be logged and stored on the control PC.- Product names can also be entered with a barcode reader- The width of the outlet of the conveyor bowl should be manually adjustable for different seed sizesAt least two years warrantyInstallation and testingUser list mustCIP ICAR-VPKAS Hawalbagh Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender