Tender For Maintenance Of Street Lighting On Pwd Roads Under West Electrical Division 2026-27. (Sh:- Removal Of Dark Points By Using Adjustable Bracket At Existing Poles At Mahashya Vasudev Marg, 6 Block, 8 Block Shubhash Nagar, Anuj Nayyar Marg, Kul
Tender Overview
Project Description
Tender for Maintenance Of Street Lighting On Pwd Roads Under West Electrical Division 2026-27. (Sh:- Removal Of Dark Points By Using Adjustable Bracket At Existing Poles At Mahashya Vasudev Marg, 6 Block, 8 Block Shubhash Nagar, Anuj Nayyar Marg, Kulwant Singh Sethi Marg, Mangal Pandey Marg Etc. In Hari Nagar Constituency (Ac-28)).
BOQ
| Sl. No. | Item Description |
| 1 | Fabrication, Designing, Supplying & Fixing of 1000 mm long Single / double / triple/Circular arm bracket(Thickness minimum 3MM) over hang with tightening bolt etc. as per design approved by Engineer-In-Charge. |
| 2 | Supplying & Fixing of Galvanized arm differenctial bracket 1000 mm long of suitable dia adjustable height Single over hang with tightening bolt etc. for existing poles including making hole in existing pole suitable for connection of fittings as per design approved by Engineer-In-Charge and removing old fitting including bracket and disconnecting old connetions and returning old fitting including bracket in store at Rama road.(Nothing extra will be paid in this behalf). |
| 3 | Supplying and drawing following sizes of PVC Insulated and PVC Sheathed Round Aluminium Conductor flexible cable for Voltage Grade 1100 Volts as per IS: 694:1990. (Internal Wire) |
| 4 | 3 x 2.50 Sqm |
| 5 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 6 | 100 watt |
| 7 | 150 watt |
| 8 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 9 | 100 watt |
| 10 | 200 watt Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender