Tender For Addn / Altn Of Drainage And Sewage Line Under Age B/R-I Alongwith Provn Of Earthing Infrastructure In Children School Under Ge Jaipur
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Sep 2026
13 days left
EMD
29020
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addn / Altn Of Drainage And Sewage Line Under Age B/R-I Alongwith Provn Of Earthing Infrastructure In Children School Under Ge Jaipur
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches or for manholes etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed |
| 2 | ,---ditto--- all as per item No. 1 above but depth exc 1.5m but not exc 3m and in hard/dense soil complete all as specified and directed. |
| 3 | Removing excavated material to a distanceexc 250 m but not exc 500 m and deposited where directed complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and as directed. |
| 5 | Taking down cement plaster or cement lime plaster, any description on brick, stone walls or concrete surface of ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 6 | M & L for rendering 15mm thick in CM 1:4 on fair faces of brick masonary or concrete surface, finished even and smooth w/o using extra cement incl mixing of water proofing compund as per manufacturers instructions complete all as specified and directed.Note : WPC shall be measured and paid seperately |
| 7 | Supply only integral water proofing compund ISI marked complete all as specified and directed. |
| 8 | Demolition of plain cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including cutting of roads etc complete all as specified and as directed. |
| 9 | M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 10 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 11 | M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in surface channels and drains and benching including finishing the top of benching even and smooth with using extra cement complete all as specified and directed. |
| 12 | M&L providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintel up to 1.5 mtr clear span, cills, steps, seismic and other similar bands, plinth course, string course, lacing course, parapets and railing up to 60cm in height, coping, kneelers, apex stones, bed plates kerb, water troughs, coping of stay/ poles and the like including weathering, slightly rounded or chamfered angles and throating incl necessary formwork complete all as specified and directed. |
| 13 | Extra for forming fair finished drain or channel 50cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed. |
| 14 | M & L for providing precast reinforced cement concrete type B1 1:2:4 (using 20mm graded aggregate) in landing, cover slab (for man hole etc) chullah hood, chajjas, water troughs, mangers, shelves and similar articles with plain faces incl form work set in cement mortar 1:4 complete all as specified and directed.Note : Reinforcement shall be measured and paid seperately |
| 15 | S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed |
| 16 | Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 17 | Demolition of precast RCC articles built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed. |
| 18 | M&L for brick work with sub-class 'B' bricks (using old size bricks ), straight or curved on plan exc 6m mean radius built in In cement mortar 1:4 complete all as specified and directed |
| 19 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diameter including all necessary scaffolding ,machinery,tools tackels and men materials complete all as specified and as directed by Engr-in-charge. |
| 20 | M&L TMT bars 6mm to 8mm dia bar, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diameter including all necessary scaffolding ,machinery,tools tackels and men materials complete all as specified and as directed by Engr-in-charge. |
| 21 | S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips conforming to Fe-410-W (Gde.E-250) quality-A or Fe-290 Gde E-165 complete all as specified and directed. |
| 22 | M&L for preparation of new steel surface of any description, not otherwise described n exc. 10cm in width or girth when unconnected with other painting or when painted with different tint and applying one coat of black bituminous paint over one coat of red oxide primer complete all as specified and directed. |
| 23 | M&L in repair for 150 mm bore (internal dia) reinforced concrete pipe, class NP3, laid on concrete bed to required slope and jointed complete with collars including demolition of old drain pipe any type i.e sal glazed or AC or RCC pipe complete all as specified and directed.Note : Excavation, Earth work and Concrete bed shall be measured and paid separately |
| 24 | M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in bed of reinforced concrete pipe 150 mm bore including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed.Note : Excavation & Earth work shall be measured and paid separately |
| 25 | M&L in repair for 200 mm bore (internal dia) reinforced concrete pipe, class NP3, laid on concrete bed to required slope and jointed complete with collars including demolition of old drain pipe any type i.e sal glazed or AC or RCC pipe complete all as specified and directed.Note : Excavation, Earth work and Concrete bed shall be measured and paid separately |
| 26 | M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in bed of reinforced concrete pipe 200 mm bore including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed.Note : Excavation & Earth work shall be measured and paid separately |
| 27 | M&L in repair for 250 mm bore (internal dia) reinforced concrete pipe, class NP3, laid on concrete bed to required slope and jointed complete with collars including demolition of old drain pipe any type i.e sal glazed or AC or RCC pipe complete all as specified and directed.Note : Excavation, Earth work and Concrete bed shall be measured and paid separately |
| 28 | M&L for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in bed of reinforced concrete pipe 250 mm bore including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed.Note : Excavation & Earth work shall be measured and paid separately |
| 29 | M&L cutting into existing man holes for connecting new drains of 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as reqd complete all as specified and as directed. |
| 30 | M&L cutting into existing man holes for connecting new drains of 200mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as reqd complete all as specified and as directed. |
| 31 | M&L cutting into existing man holes for connecting new drains of 250mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as reqd complete all as specified and as directed. |
| 32 | M& L for cleaning mud/debris/silt from the existing drains including removal of drain cover and refixing, drain of width 300 mm to 600 mm and depth 300 mm to 1000 mm and removal of debris outside the MD land in closed container complete all as specified and directed by EIC. (Note:- Length of Drain shall be measured for payment purpose) |
| 33 | Supplying, installing, commissioning and testing factory made precast circular manhole using RCC M35 (Design Mix) grade and Fe 500 Grade of reinforcement (TMT Bars) consisting of base unit, base riser, base slab with monolithically cast benching, cone section, riser unit, transition slab, adjusting unit, lifting arrangement, footstep assembled and connected with joints as mentioned in IS 17725: 2022 to achieve water tight structures including factory made precast cover slab with frame made of steel fibre reinforced concrete (SFRC), medium duty, 100 kN breaking load in circular shape and size, 75 mm thickness, minimum M30 grade of concrete, conforming to IS 12592: 2002 including 100 mm thick lean concrete M7.5 (Nominal Mix) using 40 mm graded crushed stone aggregate complete all as per manufacturer's instructions, including provision of inlet and outlet suitable for 150/200/250/300mm dia RCC hume pipe (number of inlet/outlet as directed as per site requirement), including setting in CM 1:3 to seal the joints as per manufacturer’s instructions complete all as specified and as directed and all as per given size of manhole manhole of size bottom Internal Dia 1000mm, top Iinternal Dia 560mm and internal depth of manhole 900mmNote :- Excavation and earth work for manhole shall be measured and paid separately under respective item of Schedule |
| 34 | ,---ditto-- all as per srl item No. 33 above but Manhole of size bottom IInternal Dia1000mm, top Internal Dia 560mm and internal depth of manhole 1200mm complete all as specified and directed |
| 35 | ,---ditto-- all as per srl item No. 33 above but Manhole of size bottom IInternal Dia1000mm, top Internal Dia 560mm and internal depth of manhole 1500mm complete all as specified and directed Please Enable Macros to View BoQ information |
| 36 | ,---ditto-- all as per srl item No. 33 above but Manhole of size bottom IInternal Dia1000mm, top Internal Dia 560mm and internal depth of manhole 1500mm complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender