Tender For Installation Of Automatic Fire Detection And Alarm Sys In Hangars P-145 And P-135 Of 201 Army Avn Sqn (Uh) Under Ge Nrc
Tender Value
30.30 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
13 days left
EMD
60600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation Of Automatic Fire Detection And Alarm Sys In Hangars P-145 And P-135 Of 201 Army Avn Sqn (Uh) Under Ge Nrc
BOQ
| Sl. No. | Item Description |
| 1 | Notes for the BoQ:-Design, Supply, Installation, testing and commissioning of following items all as specified and directed. (a) Fire detection and alarm system complete with fire alarm panel complying with BSEN 54 as per required loop panel of capacity from required detectors & modules including copper wiring, hooters, siren, detectors, response indicatores, mannual call points including heat and smoke detectors all as per ISO 7240-14: 2013 all as specified and directed. (b) The complete system shall be got designed from OEM/ approved consutant of fire fighting system as per relavent IS and NFPA codes.The design shall be got vetted from IIT/NIT or any reputed Govt Institute.(c) Wireless ETA certificate by Govt of India, UL/ EN 54 fire alarm certificate and manufacturers authurisation letter are mandatory and has to be uploaded along with tender/ application/ DD and hardcopy to be submitted to GE office alongwith application, DD for deciding the eligibility criteria, failing which financial bid will not be opened. |
| 2 | S&F wireless-addressable CMS (Centralised Monitoring System) Panel comprising the following features :-1. Input Voltage: 180-240VAC, 2. Operating Voltage: 10-12VDC 3. Battery Charging Voltage: 12.5-13.98VDC4. Battery Type: Drycell rechargeable Battery 5. Battery Voltage: 10-12.5VDC, 6. Battery Current: 6-7.3Amp 7. Button Type: Push Button used for Reset & Log Function.8. Input Voltage Protection, 9. Display Type: 7\\" (min size) Colour TFT Display.10. Log Record: more than 3000 event log11. Zone Capacity: 0-200, 12. Max Device Capacity 0-200 Devices.13. Alarm Display Zone, Detector, Date, Time, Landmark, Detection Type.14. Communication Type: Radio Frequency(RF)15. Frequency: 433 MHz, 866 Mhz, 2.36GHz and RF approved and certified by Indian Governemnt. 16. Hooter Decibel: 90-110dB17. Material of Hooter(Sounder): Plastic18. Operating Voltage of Hooter: 9VDC-12VDC19. Panel Box Type: 20. Automatic Battery Charging Facility21. Battery back up: more than 48 Hrs22. Inbuilt communication modules: IP and GSM23. Wireless certificate: ETA WPC certificate from Indian Government24. Approvals and Certifications: UL/FM or EN54 certified |
| 3 | S&F wireless Hooter, Repeater Panel with Flasher Hooter comprising the following features:-1. Input Voltage: 180-240VAC 2. Operating Voltage: 10-12VDC3. Battery Charging Voltage: 12.5-13.98VDC4. Battery Type: Drycell rechargeable Battery5. Battery Voltage: 10-12.5VDC 6. Battery Current: 6-7.3Amp7. Button Type: Push Button used for Reset Function8. Input Voltage Protection 9. Control panel Capacity: 0-50 Devices.10. Communication Type: Radio Frequency (RF)11. Frequency: 433 MHz, 866 Mhz, 2.36GHz and RF approved and certified by Indian Governemnt. 12. Hooter Decibel: 90-110dB13. Material of Hooter (Sounder): Plastic14. Operating Voltage of Hooter: 9VDC-12VDC15. Control Panel Box Type: Metal With High Quality Powder Coating16. Automatic Battery Charging Facility.17. Wireless certificate: ETA WPC certificate from Indian Government18. Approvals and Certifications: UL/FM or EN54 certifiedRepeater Panel:1. Input Voltage: 180VAC-240VAC2. Operating Voltage: 10VDC-12VDC3. Battery Charging Voltage: 12.5VDC-13.98VDC4. Battery Type: Drycell rechargeable Battery5. Battery back up: more than 48 Hrs6. Wireless certificate: ETA WPC certificate from Indian Government7. Approvals and Certifications: UL-FM or EN54 certified |
| 4 | S&F wireless Addressable Smoke cum Heat Detector (Multi Sensore) or fire detector comprising following features :-1. Voltage range-3-9 VDC 2. Standby current- 10-30 μΑ3. Operating Current: 10-15mA 4. Sensor: Optical sensor5. Modulation Method-FM/AM 6. LED Indication7. Address Type: unique address 8. Transmission Type: RF Waves & Signal9. Communication Type: RF frequency10. Frequency: 433 MHz, 866 Mhz, 2.36GHz and RF approved and certified by the Indian Government. 11. PCB Type: Multi-layer PCB12. Moisture protection: Using High Quality Moisture Spray & tube13. Type of material: ABS Grade/White colour14. Optical Chamber: High Quality Plastic Granules / Black Colour15. Battery Type: 9VDC Alkaline Battery.16. Battery Life: 4 Years (min) / Consider daily 2-3 Signals.17. Wireless certificate: ETA WPC certificate from Indian Government18. Approvals and Certifications: UL-FM or EN54 certified |
| 5 | S&F wireless Addressable Beam Detectors with Reflector comprising following features:-1. Operating Voltage: 12-32VDC 2. Standby Current: 17 µA max3. Sensor: Infrared Beam 4. Sensitivity: upto 100 m5. Addressing Method: unique address embedded6. Approvals and Certifications: UL FM or EN54 certified7.Frequency: 433.9MHz , 315MHz, 2.366 GHz. |
| 6 | S&F wireless Addressable Manual Call Point (MCP) comprising the following features:-1. Voltage range-3-10 VDC 2. standby current-0-5 μΑ3. Operating Current. 10-20mA 4. Button Type: Push Type Switch/ Glass Break Type5. Modulation: FM modulation 6. Address Type: unique address7 Transmission Type: RF Waves & Signal8. Communication Type: RF frequency9. Frequency: 433 MHz, 866 Mhz, 2.36GHz and RF approved and certified by Indian Governemnt. 10. PCB Type: Multi-layer PCB11 Moisture protection. Using High Quality Moisture Spray & tube12. Material Type: ABS Type/ Metal Type13. Battery Type: 9VDC Alkaline Battery14. Battery Life: 4 Years (min)15. Wireless certificate: ETA WPC certificate from Indian Government16. Approvals and Certifications: UL-FM or EN54 certified |
| 7 | S&F Flasher Hooter with Adjustable Audio & Visual Indication completed all as specified and directed.1. Wireless certificate: ETA WPC certificate from Indian Government2. Frequency: 433 MHz, 866 Mhz, 2.36GHz and RF approved and certified by the Indian Government.3. Approvals and Certifications: UL-FM or EN54 certified 4. Battery life: 4 Years (min) |
| 8 | S&F SMPS power supply complete all as specified and directed |
| 9 | S&F copper Cable 4 core 4 sqmm plus 1 core 4 sqmm, FRLS drawn through 20 mm Stainless Steel Conduit light grade including all accessories like bends and tee etc on walls /ceiling / pillars etc complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender