Tender For Annual Contract For Minor Works In Zone 5 & 6 Including Vh-1, Vh-2, Vh-Extension, Studio Apartment, Health Centre, Outreach Building, Type-1 Residential, Security Control Office, C Us School, Opportunity School, Swimming Pool, Laundromat,
Tender Overview
Project Description
Tender for Annual Contract For Minor Works In Zone 5 & 6 Including Vh-1, Vh-2, Vh-Extension, Studio Apartment, Health Centre, Outreach Building, Type-1 Residential, Security Control Office, C Us School, Opportunity School, Swimming Pool, Laundromat, Chaupati, Ramleela Ground And Other Associated Buildings (Sh: Electrical Work).
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group A |
| 3 | Group B |
| 4 | Group C |
| 5 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 6 | Group A |
| 7 | Group B |
| 8 | Group C |
| 9 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 10 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated, copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 11 | 2 x 4 Sqmm. + 1 x 4 sqmm earth wire |
| 12 | 2 x 6 Sqmm. + 1 x 6 sqmm earth wire |
| 13 | 2 x 10 Sqmm. + 1 x 6 sqmm earth wire |
| 14 | 2 x 16 Sqmm. + 1 x 6 sqmm earth wire |
| 15 | 4 x 10 Sqmm. + 2 x 6 sqmm earth wire |
| 16 | 4 x 16 Sqmm. + 2 x 6 sqmm earth wire |
| 17 | Wiring for circuit/ sub main wiring alogwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 18 | 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire |
| 19 | 2 x 4 Sq.mm + 1 x 4 Sq.mm earth wire |
| 20 | 2 x 10 Sqmm. + 1 x 6 sqmm earth wire |
| 21 | 2 x 16 Sqmm. + 1 x 6 sqmm earth wire |
| 22 | 4 x 10 Sqmm. + 2 x 6 sqmm earth wire |
| 23 | 4 x 16 Sqmm. + 2 x 6 sqmm earth wire |
| 24 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
| 25 | Group 'A' |
| 26 | Group B |
| 27 | Group 'C' |
| 28 | Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable & 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface / recess steel / PVC conduit including dismentaling as required. |
| 29 | Supplying & drawing following sizes of FRLS PVC insulated copper conductor single core cable in / on the existing surface / recessed, PVC / steel conduit as reqd. |
| 30 | 1 x 1.5 Sq.mm.. |
| 31 | 2 x 1.5 Sq.mm.. |
| 32 | 3 x 1.5 Sq.mm.. |
| 33 | 3 x 2.5 Sq.mm.. |
| 34 | 3 x 4 Sq.mm.. |
| 35 | 4 x 4 Sq.mm.. |
| 36 | 6 x 4 Sq. mm. |
| 37 | 2 x 6 sq.mm. |
| 38 | 3 x 6 Sq.mm.. |
| 39 | 4 x 6 Sq.mm.. |
| 40 | 6 x 6 Sq. mm. |
| 41 | 3 x 10 Sq. mm. |
| 42 | 3 x16 Sq. mm. |
| 43 | Supply and drawing PVC insulated copper conductor 3 core round cable of following size including connection etc. Complete as required. |
| 44 | 1.5 sq.mm |
| 45 | 2.5 sq.mm |
| 46 | 4.0 sq.mm |
| 47 | Supply and drawing of telephone wire of 2 pair 0.50 mm dia copper conductor FRLS PVC insulated unsheathed twisted wire jelly filled in existing / surface concealed conduit including numbering and connecting the wires at both the ends as required. |
| 48 | supplying and drawing co-axial TV cable RG-6 grade-0.7 mm solid copper conductor PE insulated , shielded with fine tinned copper braid and protected with PVC sheathed in existing surface /recessed steel/PVC conduit as required. |
| 49 | S & F of following size of steel conduit along with the accessories in surface/ recess I/c painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as reqd. |
| 50 | 20 mm |
| 51 | 25 mm |
| 52 | 32 mm |
| 53 | 40 mm |
| 54 | 50 mm |
| 55 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 56 | 20 mm |
| 57 | 25 mm |
| 58 | 32 mm |
| 59 | 40 mm |
| 60 | 50 mm |
| 61 | S & F following size of PVC flexible pipe alongwith the accessories on surface etc as required. |
| 62 | 20 mm |
| 63 | 25 mm |
| 64 | 32 mm |
| 65 | 40 mm |
| 66 | S & F following size of GI flexible pipe alongwith the accessories on surface etc as required. |
| 67 | 20 mm |
| 68 | 25 mm |
| 69 | 32 mm |
| 70 | 40 mm |
| 71 | Providing and fixing following sizes of PVC casing and capping on surface as reqd. |
| 72 | 20 x 12 mm |
| 73 | 25 x 16 mm |
| 74 | 32x 16 mm |
| 75 | 38 x 16 mm |
| 76 | 50 x 16 mm |
| 77 | Supply and fixing of 32 x 12.5 mm DLP mini- trunking white-system with independent cover etc. as required complete. |
| 78 | Supply and fixing of following accessories suitable for 32 mm x 12.5 mm size plastic trunking white system. |
| 79 | End cap |
| 80 | internal / external angle |
| 81 | changeable flat angle |
| 82 | flat junction |
| 83 | Supply and fixing of 32 x 20 mm DLP mini- trunking white-system with independent cover etc. as required complete. |
| 84 | Supply and fixing of following accessories suitable for 32 mm x 20 mm size plastic trunking white system. |
| 85 | End cap |
| 86 | internal / external angle |
| 87 | changeable flat angle |
| 88 | flat junction |
| 89 | Supply and fixing of 105 x 50 mm DLP trunking white-system but without cover and partition etc. as required complete. |
| 90 | Supply and fixing of following accessories suitable for 105 mm x 50 mm size plastic trunking white system. |
| 91 | 85 mm flexible cover |
| 92 | End cap |
| 93 | Internal angles- adjustable from 80°-100° |
| 94 | external angles- adjustable from 60°-120° |
| 95 | flat junction |
| 96 | flat angles |
| 97 | separation partitions |
| 98 | Joints for 85mm width cover |
| 99 | base joints |
| 100 | S & F metal box of following sizes ( nominal size ) on surface or recess with suitable size of 3 mm phenolic laminated sheet cover in the front I/c painting etc as reqd. |
| 101 | 75 mm x 75 mm x 60 mm deep |
| 102 | 100 mm x 100 mm x 60 mm deep |
| 103 | 180 mm x 100 mm x 60 mm deep |
| 104 | 200 mm x 150 mm x 60 mm deep |
| 105 | 200 mm x 250 mm x 75 mm deep |
| 106 | 200 mm x 300 mm x 60 mm deep |
| 107 | 250 mm x 300 mm x 100 mm deep |
| 108 | S & F following size/module, GI box along with modular base and cover plate for modular switches in recess as required. |
| 109 | 1/2 module (1 or 2 module) |
| 110 | 3 module |
| 111 | 4 module |
| 112 | 6 module |
| 113 | 8 module |
| 114 | 12 module |
| 115 | S & F following size modular base and cover plate for following modular metal boxes etc as required. |
| 116 | 1/2 module (1 or 2 module) |
| 117 | 3 module |
| 118 | 4 module |
| 119 | 6 module |
| 120 | 8 module |
| 121 | 12 module |
| 122 | Supplying and fixing wooden board of following sizes on surface or in recessed with suitable size of phenolic laminated sheet cover in the front etc as reqd. |
| 123 | 100 mm x 100 mm |
| 124 | 175 mm x 100 mm |
| 125 | 200 mm x 150 mm |
| 126 | 200 mm x 250 mm |
| 127 | 250 mm x 300 mm |
| 128 | Supplying and fixing following size/ modules, plastic box for modular switches on surface etc as required. Make_Legrand |
| 129 | 1 or 2 Module |
| 130 | 3 Module |
| 131 | 4 Module |
| 132 | 6 Module |
| 133 | 8 Module |
| 134 | 12 Module |
| 135 | Supply and & fixing following rating piano type switch /socket /fan regulator on the existing switch box/cover I/c connection etc. as reqd. |
| 136 | 5/6 amp one way switch |
| 137 | Two way 5/6 amp switch |
| 138 | 15/16 amp one way switch |
| 139 | 3/5 pin 5/6 Amp. Socket outlet. |
| 140 | 6 pin 15/16 Amp. Socket outlet |
| 141 | Telephone socket / jack outlet |
| 142 | TV antenna socket outlet |
| 143 | Bell push 6 A one way. . |
| 144 | Ceiling rose 3-Pin, 5A |
| 145 | PVC Batten/Angle Holder |
| 146 | Brass Batten/ angle Holder |
| 147 | Fan regulator socket type (step type) |
| 148 | Supply and & fixing following modular switch/ socket on the existing modular plates & switch box including connection but excluding modular plate etc. as reqd. |
| 149 | 5/6 Amp one way switch |
| 150 | Two way 5/6 amp switch |
| 151 | 15/16 Amp. one way switch |
| 152 | 3 Pin 5/6 Amp. socket outlet |
| 153 | 6 Pin 15/16 Amp. socket outlet. |
| 154 | Telephone socket outlet |
| 155 | TV antenna socket outlet |
| 156 | Modular bell push 6 A one way |
| 157 | Modular Type Electronic Fan regulator |
| 158 | Modular type blanking plate. |
| 159 | USB Type A & C Socket outlet(Make Legrand) |
| 160 | Supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required. |
| 161 | Supply, fixing, connecting & commissioning of 3 pin Plug top 6 Amp. as reqd. Anchor |
| 162 | Supply, fixing connecting & commissioning of 3 pin Plug top 16 Amp. as reqd. Anchor |
| 163 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 164 | Supplying, fixing, connecting & commissioning industrical type metal clad plug top/socket 20 Amp. 2P+E . (Make_ Legrand). |
| 165 | industrical type metal clad plug top 20 Amp, (2P+E) Make_ Legrand |
| 166 | industrical type metal clad socket 20 Amp, (2P+E) Make_ Legrand |
| 167 | S & F MCB of following pole and rating 240/415 volts, 10kA, 'C' series in the existing MCB DB complete with connection, testing & commissioning etc as reqd. |
| 168 | Single Pole 6 amp to 32 amp |
| 169 | Single Pole & Neutral 6 amp to 32 amp |
| 170 | Triple Pole 6 amp to 32 amp |
| 171 | Triple pole & Neutral 6 amp to 32 amp |
| 172 | SP MCB Blanking plats |
| 173 | Supplying and fixing following rating and pole, 240/440 V, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make_Legrand |
| 174 | 25-32 amp double pole RCCB |
| 175 | 40 amp double pole RCCB |
| 176 | 63 amp double pole RCCB |
| 177 | 25-32 amp four pole, RCCB |
| 178 | 40 amp four pole, RCCB |
| 179 | 63 amp four pole, RCCB |
| 180 | Supply, fixing, testing & commissioning MCB of following pole and rating 240/415 volts 'C' curve 10kA in the existing MCB DB complete as reqd. Make_Legrand |
| 181 | Single Pole 40 amp to 63 amp |
| 182 | Single Pole & Neutral 40 amp to 63 amp |
| 183 | Triple Pole 40 amp to 63 amp |
| 184 | Triple pole & Neutral 40 amp to 63 amp |
| 185 | Supply, Installing, testing and commissioning of following rating HRC fuses DIN type/ Bolted type in existing SFU including removing old faulty fuses and deposting the same in store as required complete. Make_Lauritz Knudsen(L&T) or equivalent approved make. |
| 186 | 32 Amp, HQ A2 Make_Lauritz Knudsen (Bolted Type) |
| 187 | 63 Amp, HQ A3 Make_Lauritz Knudsen (Bolted Type) |
| 188 | 100 Amp, HQ A4 Make_Lauritz Knudsen (Bolted Type) |
| 189 | 125 Amp, HQ B1 Make_Lauritz Knudsen (Bolted Type) |
| 190 | 200 Amp, HQ B2 Make_Lauritz Knudsen (Bolted Type) |
| 191 | 100 Amp, HN 000 Make_Lauritz Knudsen (DIN Type) |
| 192 | 125 Amp, HN 00 Make_Lauritz Knudsen (DIN Type) |
| 193 | 80/100/125 Amp, HN 0 Make_Lauritz Knudsen (DIN Type) |
| 194 | 160 Amp, HN 0 Make_Lauritz Knudsen (DIN Type) |
| 195 | 200 Amp, HN 0 Make_Lauritz Knudsen (DIN Type) |
| 196 | 200 Amp, HN 1 Make_Lauritz Knudsen (DIN Type) |
| 197 | 250 Amp, HN 2 Make_Lauritz Knudsen (DIN Type) |
| 198 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 199 | 32 Amp. TP&N |
| 200 | 63 Amp. TP&N |
| 201 | 100 Amp. TP&N |
| 202 | 125 Amp. TP&N |
| 203 | 200 Amp. TP&N |
| 204 | 315 Amp. TP&N |
| 205 | 400 Amp. TP&N |
| 206 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 207 | 100 Amp. 16KA,TP MCCB |
| 208 | 125 Amp. 16KA,TP MCCB |
| 209 | 150 Amp. 16KA,TP MCCB |
| 210 | 200 Amp. 16KA,TP MCCB |
| 211 | 200 Amp. 25KA,TP MCCB |
| 212 | 250 Amp. 25KA,TP MCCB |
| 213 | 250 Amp. 35/36KA,TP MCCB |
| 214 | 315 Amp. 35KA,TP MCCB |
| 215 | 400 Amp, 35 KA,TP MCCB |
| 216 | 630 Amp, 50 KA,TPMCCB |
| 217 | 100 Amp. 36KA,FP MCCB |
| 218 | 125 Amp. 36KA,FP MCCB |
| 219 | 200 Amp. 36KA,FP MCCB |
| 220 | 250 Amp. 36KA,FP MCCB |
| 221 | 250 Amp. 50KA,FP MCCB |
| 222 | 400 Amp. 50KA,FP MCCB |
| 223 | 630 Amp. 50KA,FP MCCB |
| 224 | Providing and fixing following capacity TP&N switch handle operated (fuse switch unit) steel enclosure with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 225 | 63 Amp. TP&N |
| 226 | 100 Amp. TP&N |
| 227 | 200 Amp. TP&N |
| 228 | 400 Amp. TP&N |
| 229 | Supply,fixing,connecting and commissioning power contactor with 1_NO/1_NC auxiliary Contact of following ratings and 3 pole (magnetic release) including providing connection etc. as reqd. |
| 230 | MNX-9, 230/415 V,50 Hz |
| 231 | MNX-12, 230/415 V,50 Hz |
| 232 | MNX-18, 230/415 V,50 Hz |
| 233 | Supply,fixing, connecting and commissioning power contactor of following ratings and 3 pole (magnetic release) including providing connection etc. as req |
| 234 | MNX-25, 230/415 V,50 Hz |
| 235 | MNX-32, 230/415 V,50 Hz |
| 236 | MNX-40, 230/415 V,50 Hz |
| 237 | ML 1.5, 25A, 230/415 V,50 Hz |
| 238 | Supply,fixing, connecting and commissioning 4 pole (magnetic release) power contactor of following ratings including providing connection etc. as required. |
| 239 | MCX-01, 230/415 V,50 Hz |
| 240 | MCX-02, 230/415 V,50 Hz |
| 241 | MCX-03, 230/415 V,50 Hz |
| 242 | MCX-04, 230/415 V,50 Hz |
| 243 | Supply, fixing, connecting and commissioning the add on block for contactor (MNX - 9-80// MCX 01-23) of following ratings including connection etc. as reqd. |
| 244 | 1 NO or 1 NC |
| 245 | 1 NO + 1 NC |
| 246 | 2 NO + 2 NC |
| 247 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 415 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 248 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 249 | Supplying and fixing 20 amps 240 volts, SPN industrial type, socket outlet with 2 pole earthing metal enclosure, metal plug top,along with 20 amps, 10 KA,SP MCB on surface or in recess with chained cover for the socket outlet and complete as reqd. |
| 250 | Supplying and fixing 20 amps 415 volts, TPN industrial type, socket outlet with 4 pole earthing metal enclosure, metal plug top,along with 20 amps, 10 KA,TP MCB on surface or in recess with chained cover for the socket outlet and complete as reqd. |
| 251 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete |
| 252 | S & F metal enclosure for following capacity metal enclosure box on surface/recessed etc as reqd.(Make Legrand ) |
| 253 | 100 Amp. TP MCCB |
| 254 | 160 Amp. FP MCCB |
| 255 | DP/TP/FP MCB/ ELCB |
| 256 | Supplying and fixing following way, Single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/ RCCB/ Isolator). |
| 257 | 6 way, Double door |
| 258 | 8 way, Double door |
| 259 | 12 way, Double door |
| 260 | 16 way, Double door |
| 261 | Supplying and fixing following way, Horizontal type (PPI) triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/ RCCB/ Isolator). |
| 262 | 4 way (4 + 12), Double door |
| 263 | 6 way (4 + 18), Double door |
| 264 | 8 way (4 + 24), Double door |
| 265 | Supplying and fixing following way, Vertical type triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. ( But without MCB/RCCB/Isolator). |
| 266 | 4 way (4 + 12), Double door |
| 267 | 8 way (4 + 24), Double door |
| 268 | 12 way (4 + 36), Double door |
| 269 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 270 | For 6 way, Double door SPN MCBDB |
| 271 | For 8 way, Double door SPN MCBDB |
| 272 | For 10/12 way, Double door SPN MCBDB |
| 273 | For 14/16 way, Double door SPN MCBDB |
| 274 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board (Horizontal), 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 275 | For 4 way, Double door TPN MCBDB |
| 276 | For 6 way, Double door TPN MCBDB |
| 277 | For 8 way, Double door TPN MCBDB |
| 278 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 279 | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt): Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . |
| 280 | 18 watt |
| 281 | 30 watt |
| 282 | LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ): Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 283 | 8 - 10 watt |
| 284 | 18 watt |
| 285 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt): Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 286 | 15 watt |
| 287 | 18 watt |
| 288 | 40 watt |
| 289 | LED Batten light (System lumen efficacy ≥120 <135lm/Watt) :Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 290 | 18-22 watt |
| 291 | 36 watt |
| 292 | 18-22 watt |
| 293 | 36 watt |
| 294 | Supply,Installation,Testing and commissioning LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old complete as requiired. |
| 295 | LED light fitting 20 watt with PC-Batten, Make_Havells or approved make |
| 296 | LED light fitting 20 watt with AL-Batten, Make_Havells or approved make |
| 297 | LED Ceiling Light 6 watt surface/recess mounting, FR-plastic housing, round/ square shape, Make_Havells or approved make |
| 298 | LED Ceiling Light 12 watt surface/recess mounting, FR-plastic housing, round/ square shape, Make_Havells or approved make |
| 299 | LED Ceiling Light 18/20 watt surface/recess mounting, FR-plastic housing, round/ square shape, Make_Havells or approved make |
| 300 | LED light fitting (Integrated) 36 watt (surface/recess type) , 600X600 mm; Make_Havells or approved make |
| 301 | LED light fitting (Integrated) 36 watt (surface/recess type) , 300X1200 mm; Make_Havells or approved make |
| 302 | Wall bracket fitting complete, Make_Havells, code: LHFOAJE1TZ1I060, model Floretine WL 1LS B22 SS or approved make |
| 303 | Wall bracket wooden base with 9 watt LED bulb (Decorative Cat. No.5990/L or equivalent approved make). |
| 304 | Picture light fitting chrome 10W. (Make Philiphs (Cat.No 48043) or equivalent approved make |
| 305 | LED Mirror Light 5 watt, 1 ft long; Make_Havells or approved make |
| 306 | LED Mirror Light 10 watt, 2 ft long; Make_Havells or approved make |
| 307 | 3 watt spotlight Make_Havells or approved make |
| 308 | LED skirting light 3-Module, Make_Legrand |
| 309 | LED Bulkhead fitting 10 watt, 120 lm/W, IP65; Make_Havells or approved make |
| 310 | LED Post Top Lantern 40 watt (Make_Crompton Cat.No.LPTO-40-CDL-M) |
| 311 | Supply, Fixing,Testing and commissioning of following LED Tubes and lamps in existing old fittngs including connection etc. complete as required. |
| 312 | LED PC Tube rod 20 watt,4 ft long, Make _Crompton |
| 313 | LED Picture/candle lamp 2.7 watt pin/screw (E14/E27/B22 type) (Make_Havells,Philips or approved make) |
| 314 | LED Picture/candle lamp 10 watt pin/screw (E14/E27/B22 type) (Make_Havells,Philips or approved make) |
| 315 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).: Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 316 | 25 watt |
| 317 | 36 watt |
| 318 | 45 watt |
| 319 | 72 watt |
| 320 | LED Flood Light, powder coated pressure die cast aluminium (System umen efficacy >135lm/Watt): Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 321 | 100 watt |
| 322 | 150 watt |
| 323 | 200 watt |
| 324 | 250 watt |
| 325 | Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 326 | 1 Output per phase and suitable for single phase supply |
| 327 | 1-output Astronomical Timer Switch complete as reqd. Make_Legrand Cat No. 4126 54 |
| 328 | 2 Output per phase and suitable for single phase supply |
| 329 | 3 Output per phase and suitable for three phase supply |
| 330 | Supply installation, testing and commissioning of 3-Ph,DOL Starter for 10 HP Motor, 415/440 volts,with sheet steel enclosure, type MN with SPP feature including drilling holes on the board, earthing etc. complete as reqd. (Make_ L&T (Cat no SS94351) or approved make.) |
| 331 | Supply and fixing/mounting of outdoor type Pole box/ panel box with 1.6 mm thick MS body powder coated with extended MS hood over top for protection from rain water, having almirah type hinge and panel key type lock front door, openings for inlet and outlet of wire/cable at suitable locations complete as required. |
| 332 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement :3 coarse sand:6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. |
| 333 | Above 4.5 meter and upto 6.5 meter |
| 334 | Above 6.5 meter and upto 8.0 meter |
| 335 | Above 8.0 meter and upto 10.0 meter |
| 336 | Above 10.00 meter and upto 12.00 meter |
| 337 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required |
| 338 | 32 mm dia |
| 339 | 40 mm dia |
| 340 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 341 | Dismantling of pole / street light standard/ strut embeded in brick bllast foundation etc as required. |
| 342 | Supply & fixing of 65 mm dia.'B' class GI pole 4.5 metre long for post top lantern i/c base plate 300 x 300 x 3mm GI reducer & nipple for mounting the fitting with painting etc. grouting in cement concrete 1: 3: 6 (1 cement : 3 coarse sand : 6 stone aggregate 40mm nominal size 0.4mm dia x 0.5 mm high to accommodate the looping) complete as reqd. |
| 343 | Painting steel tubular / GI street light poles of following size with minimum two coats of good quality (approved Make) aluminium paint after cleaning the surface and rubbing the old paint etc. as required complete. |
| 344 | up to 4.5 mtr. Long |
| 345 | above 4.5 mtr. Upto 9 mtrs. Long |
| 346 | Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size upto 35 sq.mm. |
| 347 | direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd. |
| 348 | In pipe |
| 349 | In open duct |
| 350 | On surface with MS clamp (clamped with 1mm thick saddle) |
| 351 | Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size above 35 sqmm and upto 95 sq.mm. |
| 352 | Direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd. |
| 353 | In pipe |
| 354 | In open duct |
| 355 | On surface with MS clamp (clamped with 25 X3 mm MS flat clamp ) |
| 356 | Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size above 95 sqmm and upto 185 sqmm. |
| 357 | Direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd. |
| 358 | In pipe |
| 359 | In open duct |
| 360 | On surface with MS clamp (clamped with 25/40X3 mm MS flat clamp ) |
| 361 | Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size above 185 sqmm and upto 400 sqmm. |
| 362 | Direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd. |
| 363 | In pipe |
| 364 | In open duct |
| 365 | On surface with MS clamp (clamped with 40X3 mm MS flat clamp ) |
| 366 | Lifting & removing cable of any size from trench/ clamps on surface, making roll depositing the same in the store I/c cartage etc as reqd. |
| 367 | Up to 35sqmm |
| 368 | Above 35 to 95 Sqmm |
| 369 | Above 95 to 185 Sqmm |
| 370 | Above 185 to 400 Sqmm |
| 371 | Digging cable trench, lifting brick & cable and relaying the cable of size upto 400 sqmm including refilling the same as required. |
| 372 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted/welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 373 | Supply of one number PVC insulated & PVC sheathed/XLPE aluminium conductor steel armoured power cable of following sizes 1.1kV grade as per IS 7098 (part 1) 1988. Make_Havells or equivalent approved make |
| 374 | 2 x 10 sq.mm. |
| 375 | 2 x 16 sq.mm. |
| 376 | 3.5 x 25 sq.mm. |
| 377 | 3.5 x 35 sq.mm. |
| 378 | 3.5 x 50 sq.mm. |
| 379 | 3.5 x 70 sq.mm. |
| 380 | 3.5 x 95 sq.mm. |
| 381 | 3.5 x 120 sq.mm. |
| 382 | 3.5 x 150 sq.mm. |
| 383 | 3.5 x 185 sq.mm. |
| 384 | 3.5 x 240 sq.mm. |
| 385 | 3.5 x 300 sq.mm. |
| 386 | 3.5 x 400 sq.mm. |
| 387 | Supply of following pairs telephone armoured cable (jelly filled) 0.5 mm tinned copper conductor in following manner as per specification complete as required of approved make. |
| 388 | Jelly filled 5 pair 0.5 mm armoured telephone cable |
| 389 | Jelly filled 10 pair 0.5 mm armoured telephone cable |
| 390 | Jelly filled 20 pair 0.5 mm armoured telephone cable |
| 391 | Jelly filled 50 pair 0.5 mm armoured telephone cable |
| 392 | Jelly filled 100 pair 0.5 mm armoured telephone cable |
| 393 | Supplying and making end termination with brass compression gland, aluminium lugs for following size of PVC insulated & PVC sheathed / XLPE aluminium cable of 1.1kV grade as reqd. |
| 394 | 2 x 6 sq.mm. |
| 395 | 2 x 10 sq.mm. |
| 396 | 2 x 16 sq.mm. |
| 397 | 2 x 25 sq.mm. |
| 398 | 3.5 x 25 sq.mm. |
| 399 | 3.5 x 35 sq.mm. |
| 400 | 3.5 x 50 sq.mm. |
| 401 | 3.5 x 70 sq.mm. |
| 402 | 3.5 x 95 sq.mm. |
| 403 | 3.5 x 120 sq.mm. |
| 404 | 3.5 x 150 sq.mm. |
| 405 | 3.5 x 185 sq.mm. |
| 406 | 3.5 x 240 sq.mm. |
| 407 | 3.5 x 300 sq.mm. |
| 408 | 3.5 x 400 sq.mm. |
| 409 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 410 | 2 x 16 sq.mm. |
| 411 | 2 x 25/35/50 sq.mm. |
| 412 | 3.5 x 25/35/50 sq.mm. |
| 413 | 3.5 x 70 sq.mm. |
| 414 | 3.5 x 95 sq.mm. |
| 415 | 3.5 x 120/150/185 sq.mm. |
| 416 | 3.5 x 240 sq.mm. |
| 417 | 3.5 x 300 sq.mm. |
| 418 | 3.5 x 400 sq.mm. |
| 419 | Dismantling & refixing brass compression type cable gland of following size armoured cables complete as required.. |
| 420 | upto 50 sqmm |
| 421 | Above 50 sqmm upto 120 sqmm |
| 422 | Above 120sqmm upto 400 sqmm |
| 423 | S&F, Copper tube / reducer/ lug terminals suitable for following size of conductor. |
| 424 | 6 /10/16 Sq.mm. |
| 425 | 25/35/50 Sq.mm. |
| 426 | Earthing with G.I earth pipe 4.5 metre long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 427 | Earthing with GI earth plate size 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/ coke and salt as required. |
| 428 | Providing & fixing 25mm x 5mm Copper strip in 40 mm dia GI pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required. |
| 429 | Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode including connection with GI nut , bolt,spring washer excavation and refilling etc. as reqd. |
| 430 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required |
| 431 | Chemical Earthing with GI earth electrode 50 mm dia x 3 Mtr length with full GI strip including earth enhancing compound and RCC precast PIT cover and earthing pit etc as reqd. |
| 432 | Providing & Fixing following strip on surface or in recessed for connection etc as reqd. |
| 433 | 25 mm x 5 mm copper strip |
| 434 | 25 mm x 5 mm G.I. strip |
| 435 | Providing and fixing 6 SWG dia. GI wire on surface or in recess for loop earthing as reqd. |
| 436 | Providing and fixing 6 SWG dia. GI wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit submain wiring/cable as required. |
| 437 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit submain wiring/cable as required. |
| 438 | Providing and fixing of lightning conductor final, made of 25 mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc.complete as required. |
| 439 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run). |
| 440 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for Vertical run) |
| 441 | Fixing of copper / G.I. tape 20 mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required (For horizontal run). |
| 442 | Fixing of copper / G.I. tape 20 mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required (for Vertical run). |
| 443 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 444 | 1200 mm |
| 445 | 1400 mm |
| 446 | Supply, Installation, testing & commissioning of AC ceiling fan of following sweeps, aluminium die cast body , copper wound, double bearing, less 70 watts 220 volts 50 Hz without regulator I/c wiring the down rods of standard length up to 30 cm with 1.5 sq.mm. PVC insulated copper conductor single core cable etc as reqd. ( ISI marked.) |
| 447 | 1200 mm Make_Havells; model: ES-40 |
| 448 | 1400 mm Make_Havells; model: Samrat HS |
| 449 | Supply, fixing, testing and commissioning wall fan, 400 mm dia,1Ǿ AC power supply,50 Hz complete as required. Make_Havells, Model Swing NS Wall 4S (4 Star) |
| 450 | SITC of wall mounting air circulator fan 450 mm dia,230 volts, 1400 rpm heavy duty,metal body including connecstion and fixing rag bolts complete as reqd. Make_Havells; Model Turboforce Wall Fan |
| 451 | Supply, fixing, testing and commissioning domestic fresh air ventilation fan, of following dia,plastic body,1Ǿ AC power supply,50 Hz complete as required. Make_Havells; Model: Thrill Air DLX (New) |
| 452 | 150 mm dia, Make_Havells; Model: Ventil Air DXZ Neo |
| 453 | 200 mm dia, Make_Havells; Model: Thrill Air DLX (New) |
| 454 | 250 mm dia, Make_Havells; Model: Thrill Air DLX (New) |
| 455 | Supply, Installation, testing and commissioning of exhaust fan of following sizes,1Ǿ AC power supply,50 Hz in the existing opening I/c connection, rag bolts complete as reqd. Make_Havells, model Turboforce Exhaust 1 phase 900 rpm |
| 456 | 300mm Make_Havells, model Turboforce Exhaust 1 phase 900 rpm |
| 457 | 380 mm Make_Havells, model Turboforce Exhaust 1 phase 900 rpm |
| 458 | 450 mm Make_Havells, model Turboforce Exhaust 1 phase 900 rpm |
| 459 | 600 mm Make_Havells, model Turboforce Exhaust 1 phase 900 rpm |
| 460 | Supply and fixing of louver for exhaust fan of following sizes with rag bolts as reqd. |
| 461 | Overhauling of ceiling fan of any size including dismantling and refixing of fan, bearings, checking/ cleaning the all parts, supplying & replacement of rubber seal, rubber rings, nut bolts, hanger clamps, bearing plates, cotter/ split pin, varnishing if reqd etc, reassembling, testing and commissioning of fan as reqd. complete. |
| 462 | Overhauling exhaust fan of following size including opening and refitting of fan after checking ,cleaning all parts, bearing/ bush, greasing/ oiling including providing & replacement of defective rubber real, rings, nut,bolts ,washer ,hanger clamps ,bearing plates,cutter/split pin etc complete as required. |
| 463 | upto 12\\" dia |
| 464 | 15\\" to 18\\" dia |
| 465 | above 18\\" to 24\\" dia |
| 466 | Overhauling of air-curtain of any size including dismantling and re-fitting the unit with rag bolts, checking, clening, oiling greasing, replacement of defective spares etc. (Extra cost will be paid against used new parts after submitted bill). reassembling the air curtain testing and commissioning as reqd.. |
| 467 | Cleaning of ceiling fan with detergent at site and replacement of damaged items i.e. rubber real, cutter pin, capacitor clamp, nut and bolts of hanger clamps etc as required. |
| 468 | Normal height |
| 469 | Extra height |
| 470 | Cleaning of exhaust fan installed in kitchen/mess area up to 18\\"size including dismantling bearings, checking, cleaning, greasing, replacing rubber rings,nut bolts,hander clamps,bearing plates,cutter pin etc. if required reassembling, testing & commissioning complete as required. |
| 471 | Normal height |
| 472 | Extra height height |
| 473 | Cleaning of air curtain of any size installed in kitchen/mess area including opening cabinet, bearings, checking, cleaning, greasing, replacing rubber rings,nut bolts,hander clamps,bearing plates,cutter pin etc. if required reassembling, testing & commissioning complete as required. |
| 474 | Supply & Fixing of following size bearing in ceiling/exhaust/wall fans complete as required. |
| 475 | Bearing No. 6201 |
| 476 | Bearing No. 6202 |
| 477 | Bearing No. 6203 |
| 478 | Bearing No. 6204 |
| 479 | Supplying and fixing capacitor of following rating suitable for ceiling fan / exhaust fan / air-curtain etc. |
| 480 | 2.5mfd |
| 481 | 4 or 5 mfd |
| 482 | 8 mfd |
| 483 | 10 mfd |
| 484 | Repairing of housing for bearing side /bush side /in fan body in ceiling fan /exhaust fan /rally fan/ cabin fan/ pedestal fan/ water lifting pump/ air-circulator. |
| 485 | Carriage of ceiling fan and regulator / exhaust fan from store to site as required. |
| 486 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 487 | Providing and fixing extra conduit down rods of 20 mm dia. 2 x 10 cm length with 2 x 1.5 Sqmm FRLS PVC insulated copper conductor single core cable i/c painting etc. as reqd. (Note - More than 5 cm length shall be rounded nearest 10 cm & 5 cm or less shall be ignore) |
| 488 | Fixing of geyser vertical/Horizontal type of capacity upto 50 ltrs including supplying and fixing of flexible pipe and nut/bolts/washers complete as required. |
| 489 | Supply and Fixing of geyser vertical type of following capacity complete as required (Make_ Racold CDR/ Platinum or its equivalent make). |
| 490 | 25 litrs. Capacity |
| 491 | 50 litrs. Capacity |
| 492 | Installation, testing and commissioning of heating element or backup element or thermostat or reset in hot water geyser including drain out water removing old and connecting new one complete as required. |
| 493 | Supply of following heating elements for geyser complete required. |
| 494 | Small Flange HE (sphere hot type) 2kw |
| 495 | Triangular/ Broad Flange HE 2kw (Bajaj/USHA Lexus bend type) |
| 496 | Heating element for Racold Platinum model (3200 watt) or equivalent approved make |
| 497 | Heating element for Racold CDR DLX model (2000 watt) or equivalent approved make |
| 498 | Supply of electrical back-up 3Kw ISI marked for solar hot water tank complete as reqd. |
| 499 | Supply of following accessories for geyser complete required. |
| 500 | Thermostat 7\\"/11\\" long. |
| 501 | Thermal cut (reset) 7\\"/11\\" long |
| 502 | Thermosat (Capillary type) |
| 503 | Thermal cut (reset) with or without capillary |
| 504 | Copper tube with outer dia 1/4 inch, wall thickness 25 SWG, hollow pipe for geyser connection as required. |
| 505 | Supply of flexible pipe 1/2\\" |
| 506 | Supply of Glass Incandescent Electric Water Heater Indicator |
| 507 | Supply of Gyser Rubber Washer |
| 508 | Dismantling of geyser of vertical/Horizontal type upto 50 litre capacity complete as required. And depositing the same in departmental store. |
| 509 | Supply,installation, testing and commissioning 16 A key card switch 2 module. Make_Legrand_cat no.AC27110MW |
| 510 | Supply,installation, testing and commissioning key fob for key card ; Make_Legrand cat no.679255 |
| 511 | Fixing Internet rack/ telephone DB of any size on surface/recessed including painting, making good with enamel paint etc. as reqd. |
| 512 | Fixing of RJ-45 modular box with cover plate or I/o box for internet as required. ( box and cover plate will be supplied by dept.) |
| 513 | on surface |
| 514 | in recess |
| 515 | S & F 3 mm thick phenolic laminated sheet on existing board with brass screw & cup washer etc as reqd. |
| 516 | S & F bakelite sheet 5 mm thick complete with nut,bolts as reqd. |
| 517 | Locating fault in the cable lines with meggar etc and rectifying removing & restoring the same and making good the damages etc as required. |
| 518 | Locating fault in wiring rectifying removing & restoring supply the same & making good the damages etc as reqd. |
| 519 | Providing 1/3 phase temporary service connection from supply source to desired place up to the lead/ cable 35 sq.mm. of 50 mtr. and disconnecting the same including to & fro cartage. ( extension board and cable will be supplied by the dept.) |
| 520 | Laying of 1/2/3 run of UTP cable enhanced cat 5/cat 6 cable/optical fibre cable/ telephone cable in existing steel conduit pipe/GI pipe/ raceway / RCC pipe as reqd. the cost shall also include numbering of networking wire from room to rack as reqd. (wire will be supplied by dept) |
| 521 | Supply & Laying of 32 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete. |
| 522 | In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd. |
| 523 | Laying charges In Pipe |
| 524 | Laying charges On Surface |
| 525 | Laying charges in open duct |
| 526 | Supply & Laying of 40 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete. |
| 527 | In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd. |
| 528 | Laying charges In Pipe |
| 529 | Laying charges On Surface |
| 530 | Laying charges in open duct |
| 531 | Supply & Laying of 50 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete. |
| 532 | In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd. |
| 533 | Laying charges In Pipe |
| 534 | Laying charges On Surface |
| 535 | Laying charges in open duct |
| 536 | Dismantling and fixing/refixing of LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old complete as required. |
| 537 | Upto 3 Meter |
| 538 | Above 3 meter and upto 6 Meter |
| 539 | Above 6 meter and upto 9 Meter |
| 540 | Above 9 meter and upto 12 Meter |
| 541 | Dismantling and re-fixing of any size ceiling fan/light fixture from following height complete including connection as required. |
| 542 | Normal Height |
| 543 | Extra Height |
| 544 | Dismantling or refixing of exhaust fan of size 12\\"to 24\\" with required nut, bolts, washer, fasteners and rag bolts etc. as reqd. |
| 545 | Dismantling or refixing of air-curtain of any size complete including electrical connection as required. |
| 546 | Dismantling and refixing of wooden board of any sizes on surface or in recessed etc as reqd. |
| 547 | Dismantling & refixing DB/TPN Switches upto 400A/ Busbar chamber/ M.S. boxes alongwith all accessories etc as reqd. |
| 548 | Dismantling of rally fan / cabin fan/ ceiling fan/ light fitting from normal height and depositing in store as reqd. |
| 549 | Dismantling the old MS/ PVC conduit pipe of all sizes from surface/recessed & making good the damages I/c filling the holes of the surface and depositing the same as reqd. |
| 550 | Dismantling the old wood batten/PVC casing capping of all sizes from surface & making good the damages I/c filling the holes of the surface and depositing the same as reqd. |
| 551 | Dismantling of old/damaged DB/ TPN switch Box etc. on surface/ recessed including making good and painting with enamel paint etc as reqd |
| 552 | Dismantling of switch board/wooden/MS/PVC boxes of any size up to 250x300 mm on surface/ recessed including making good and painting with enamel paint etc as reqd and depositing the same in store as required. |
| 553 | Dismantling, disconnecting 3x1.5/2.5/4.0/6.0/10.0 sqmm wire from existing conduit pipe casing and capping and making role and depositing in store as reqd. |
| 554 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 555 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil cum |
| 556 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 557 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 558 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor level in all shapes and sizes in : |
| 559 | Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 560 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 561 | Providing 12 mm cement plaster in fine sand of mix : 1:6 (1 cement: 6 fine sand) at all levels |
| 562 | Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. |
| 563 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-incharge.e etc. as reqd |
| 564 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar. |
| 565 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand ) including trenching (75 cm deep) and refilling etc as required. |
| 566 | 100 mm dia |
| 567 | 150 mm dia |
| 568 | 250 mm dia |
| 569 | 300 mm dia |
| 570 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work |
| 571 | 40 mm dia |
| 572 | 50 mm dia |
| 573 | 65 mm dia |
| 574 | 80 mm dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender