Tender For Annual Contract For Minor Works In Zone 5 & 6 Including Vh-1, Vh-2, Vh-Extension, Studio Apartment, Health Centre, Outreach Building, Type-1 Residential, Security Control Office, C Us School, Opportunity School, Swimming Pool, Laundromat,

Issued by Government Departments · Kanpur Nagar, Uttar Pradesh
Tender Value
34.92 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
13 days left
EMD
69842
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Contract For Minor Works In Zone 5 & 6 Including Vh-1, Vh-2, Vh-Extension, Studio Apartment, Health Centre, Outreach Building, Type-1 Residential, Security Control Office, C Us School, Opportunity School, Swimming Pool, Laundromat, Chaupati, Ramleela Ground And Other Associated Buildings (Sh: Electrical Work).

BOQ

Name of Work:- Annual contract for minor works in Zone 5 & 6 including VH-1, VH-2, VH-Extension, Studio Apartment, Health Centre, Outreach Building, Type-1 Residential, Security Control Office, C us School, Opportunity School, Swimming Pool, Laundromat, Chaupati, Ramleela Ground and other associated buildings (SH: Electrical Work).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group A
3Group B
4Group C
5Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
6Group A
7Group B
8Group C
9Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
10Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated, copper conductor, single core cable in surface/ recessed steel conduit as required.
112 x 4 Sqmm. + 1 x 4 sqmm earth wire
122 x 6 Sqmm. + 1 x 6 sqmm earth wire
132 x 10 Sqmm. + 1 x 6 sqmm earth wire
142 x 16 Sqmm. + 1 x 6 sqmm earth wire
154 x 10 Sqmm. + 2 x 6 sqmm earth wire
164 x 16 Sqmm. + 2 x 6 sqmm earth wire
17Wiring for circuit/ sub main wiring alogwith earth wire the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
182 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
192 x 4 Sq.mm + 1 x 4 Sq.mm earth wire
202 x 10 Sqmm. + 1 x 6 sqmm earth wire
212 x 16 Sqmm. + 1 x 6 sqmm earth wire
224 x 10 Sqmm. + 2 x 6 sqmm earth wire
234 x 16 Sqmm. + 2 x 6 sqmm earth wire
24Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
25Group 'A'
26Group B
27Group 'C'
28Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable & 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface / recess steel / PVC conduit including dismentaling as required.
29Supplying & drawing following sizes of FRLS PVC insulated copper conductor single core cable in / on the existing surface / recessed, PVC / steel conduit as reqd.
301 x 1.5 Sq.mm..
312 x 1.5 Sq.mm..
323 x 1.5 Sq.mm..
333 x 2.5 Sq.mm..
343 x 4 Sq.mm..
354 x 4 Sq.mm..
366 x 4 Sq. mm.
372 x 6 sq.mm.
383 x 6 Sq.mm..
394 x 6 Sq.mm..
406 x 6 Sq. mm.
413 x 10 Sq. mm.
423 x16 Sq. mm.
43Supply and drawing PVC insulated copper conductor 3 core round cable of following size including connection etc. Complete as required.
441.5 sq.mm
452.5 sq.mm
464.0 sq.mm
47Supply and drawing of telephone wire of 2 pair 0.50 mm dia copper conductor FRLS PVC insulated unsheathed twisted wire jelly filled in existing / surface concealed conduit including numbering and connecting the wires at both the ends as required.
48supplying and drawing co-axial TV cable RG-6 grade-0.7 mm solid copper conductor PE insulated , shielded with fine tinned copper braid and protected with PVC sheathed in existing surface /recessed steel/PVC conduit as required.
49S & F of following size of steel conduit along with the accessories in surface/ recess I/c painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as reqd.
5020 mm
5125 mm
5232 mm
5340 mm
5450 mm
55Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
5620 mm
5725 mm
5832 mm
5940 mm
6050 mm
61S & F following size of PVC flexible pipe alongwith the accessories on surface etc as required.
6220 mm
6325 mm
6432 mm
6540 mm
66S & F following size of GI flexible pipe alongwith the accessories on surface etc as required.
6720 mm
6825 mm
6932 mm
7040 mm
71Providing and fixing following sizes of PVC casing and capping on surface as reqd.
7220 x 12 mm
7325 x 16 mm
7432x 16 mm
7538 x 16 mm
7650 x 16 mm
77Supply and fixing of 32 x 12.5 mm DLP mini- trunking white-system with independent cover etc. as required complete.
78Supply and fixing of following accessories suitable for 32 mm x 12.5 mm size plastic trunking white system.
79End cap
80internal / external angle
81changeable flat angle
82flat junction
83Supply and fixing of 32 x 20 mm DLP mini- trunking white-system with independent cover etc. as required complete.
84Supply and fixing of following accessories suitable for 32 mm x 20 mm size plastic trunking white system.
85End cap
86internal / external angle
87changeable flat angle
88flat junction
89Supply and fixing of 105 x 50 mm DLP trunking white-system but without cover and partition etc. as required complete.
90Supply and fixing of following accessories suitable for 105 mm x 50 mm size plastic trunking white system.
9185 mm flexible cover
92End cap
93Internal angles- adjustable from 80°-100°
94external angles- adjustable from 60°-120°
95flat junction
96flat angles
97separation partitions
98Joints for 85mm width cover
99base joints
100S & F metal box of following sizes ( nominal size ) on surface or recess with suitable size of 3 mm phenolic laminated sheet cover in the front I/c painting etc as reqd.
10175 mm x 75 mm x 60 mm deep
102100 mm x 100 mm x 60 mm deep
103180 mm x 100 mm x 60 mm deep
104200 mm x 150 mm x 60 mm deep
105200 mm x 250 mm x 75 mm deep
106200 mm x 300 mm x 60 mm deep
107250 mm x 300 mm x 100 mm deep
108S & F following size/module, GI box along with modular base and cover plate for modular switches in recess as required.
1091/2 module (1 or 2 module)
1103 module
1114 module
1126 module
1138 module
11412 module
115S & F following size modular base and cover plate for following modular metal boxes etc as required.
1161/2 module (1 or 2 module)
1173 module
1184 module
1196 module
1208 module
12112 module
122Supplying and fixing wooden board of following sizes on surface or in recessed with suitable size of phenolic laminated sheet cover in the front etc as reqd.
123100 mm x 100 mm
124175 mm x 100 mm
125200 mm x 150 mm
126200 mm x 250 mm
127250 mm x 300 mm
128Supplying and fixing following size/ modules, plastic box for modular switches on surface etc as required. Make_Legrand
1291 or 2 Module
1303 Module
1314 Module
1326 Module
1338 Module
13412 Module
135Supply and & fixing following rating piano type switch /socket /fan regulator on the existing switch box/cover I/c connection etc. as reqd.
1365/6 amp one way switch
137Two way 5/6 amp switch
13815/16 amp one way switch
1393/5 pin 5/6 Amp. Socket outlet.
1406 pin 15/16 Amp. Socket outlet
141Telephone socket / jack outlet
142TV antenna socket outlet
143Bell push 6 A one way. .
144Ceiling rose 3-Pin, 5A
145PVC Batten/Angle Holder
146Brass Batten/ angle Holder
147Fan regulator socket type (step type)
148Supply and & fixing following modular switch/ socket on the existing modular plates & switch box including connection but excluding modular plate etc. as reqd.
1495/6 Amp one way switch
150Two way 5/6 amp switch
15115/16 Amp. one way switch
1523 Pin 5/6 Amp. socket outlet
1536 Pin 15/16 Amp. socket outlet.
154Telephone socket outlet
155TV antenna socket outlet
156Modular bell push 6 A one way
157Modular Type Electronic Fan regulator
158Modular type blanking plate.
159USB Type A & C Socket outlet(Make Legrand)
160Supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required.
161Supply, fixing, connecting & commissioning of 3 pin Plug top 6 Amp. as reqd. Anchor
162Supply, fixing connecting & commissioning of 3 pin Plug top 16 Amp. as reqd. Anchor
163Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
164Supplying, fixing, connecting & commissioning industrical type metal clad plug top/socket 20 Amp. 2P+E . (Make_ Legrand).
165industrical type metal clad plug top 20 Amp, (2P+E) Make_ Legrand
166industrical type metal clad socket 20 Amp, (2P+E) Make_ Legrand
167S & F MCB of following pole and rating 240/415 volts, 10kA, 'C' series in the existing MCB DB complete with connection, testing & commissioning etc as reqd.
168Single Pole 6 amp to 32 amp
169Single Pole & Neutral 6 amp to 32 amp
170Triple Pole 6 amp to 32 amp
171Triple pole & Neutral 6 amp to 32 amp
172SP MCB Blanking plats
173Supplying and fixing following rating and pole, 240/440 V, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make_Legrand
17425-32 amp double pole RCCB
17540 amp double pole RCCB
17663 amp double pole RCCB
17725-32 amp four pole, RCCB
17840 amp four pole, RCCB
17963 amp four pole, RCCB
180Supply, fixing, testing & commissioning MCB of following pole and rating 240/415 volts 'C' curve 10kA in the existing MCB DB complete as reqd. Make_Legrand
181Single Pole 40 amp to 63 amp
182Single Pole & Neutral 40 amp to 63 amp
183Triple Pole 40 amp to 63 amp
184Triple pole & Neutral 40 amp to 63 amp
185Supply, Installing, testing and commissioning of following rating HRC fuses DIN type/ Bolted type in existing SFU including removing old faulty fuses and deposting the same in store as required complete. Make_Lauritz Knudsen(L&T) or equivalent approved make.
18632 Amp, HQ A2 Make_Lauritz Knudsen (Bolted Type)
18763 Amp, HQ A3 Make_Lauritz Knudsen (Bolted Type)
188100 Amp, HQ A4 Make_Lauritz Knudsen (Bolted Type)
189125 Amp, HQ B1 Make_Lauritz Knudsen (Bolted Type)
190200 Amp, HQ B2 Make_Lauritz Knudsen (Bolted Type)
191100 Amp, HN 000 Make_Lauritz Knudsen (DIN Type)
192125 Amp, HN 00 Make_Lauritz Knudsen (DIN Type)
19380/100/125 Amp, HN 0 Make_Lauritz Knudsen (DIN Type)
194160 Amp, HN 0 Make_Lauritz Knudsen (DIN Type)
195200 Amp, HN 0 Make_Lauritz Knudsen (DIN Type)
196200 Amp, HN 1 Make_Lauritz Knudsen (DIN Type)
197250 Amp, HN 2 Make_Lauritz Knudsen (DIN Type)
198Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
19932 Amp. TP&N
20063 Amp. TP&N
201100 Amp. TP&N
202125 Amp. TP&N
203200 Amp. TP&N
204315 Amp. TP&N
205400 Amp. TP&N
206Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
207100 Amp. 16KA,TP MCCB
208125 Amp. 16KA,TP MCCB
209150 Amp. 16KA,TP MCCB
210200 Amp. 16KA,TP MCCB
211200 Amp. 25KA,TP MCCB
212250 Amp. 25KA,TP MCCB
213250 Amp. 35/36KA,TP MCCB
214315 Amp. 35KA,TP MCCB
215400 Amp, 35 KA,TP MCCB
216630 Amp, 50 KA,TPMCCB
217100 Amp. 36KA,FP MCCB
218125 Amp. 36KA,FP MCCB
219200 Amp. 36KA,FP MCCB
220250 Amp. 36KA,FP MCCB
221250 Amp. 50KA,FP MCCB
222400 Amp. 50KA,FP MCCB
223630 Amp. 50KA,FP MCCB
224Providing and fixing following capacity TP&N switch handle operated (fuse switch unit) steel enclosure with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
22563 Amp. TP&N
226100 Amp. TP&N
227200 Amp. TP&N
228400 Amp. TP&N
229Supply,fixing,connecting and commissioning power contactor with 1_NO/1_NC auxiliary Contact of following ratings and 3 pole (magnetic release) including providing connection etc. as reqd.
230MNX-9, 230/415 V,50 Hz
231MNX-12, 230/415 V,50 Hz
232MNX-18, 230/415 V,50 Hz
233Supply,fixing, connecting and commissioning power contactor of following ratings and 3 pole (magnetic release) including providing connection etc. as req
234MNX-25, 230/415 V,50 Hz
235MNX-32, 230/415 V,50 Hz
236MNX-40, 230/415 V,50 Hz
237ML 1.5, 25A, 230/415 V,50 Hz
238Supply,fixing, connecting and commissioning 4 pole (magnetic release) power contactor of following ratings including providing connection etc. as required.
239MCX-01, 230/415 V,50 Hz
240MCX-02, 230/415 V,50 Hz
241MCX-03, 230/415 V,50 Hz
242MCX-04, 230/415 V,50 Hz
243Supply, fixing, connecting and commissioning the add on block for contactor (MNX - 9-80// MCX 01-23) of following ratings including connection etc. as reqd.
2441 NO or 1 NC
2451 NO + 1 NC
2462 NO + 2 NC
247Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 415 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
248Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.
249Supplying and fixing 20 amps 240 volts, SPN industrial type, socket outlet with 2 pole earthing metal enclosure, metal plug top,along with 20 amps, 10 KA,SP MCB on surface or in recess with chained cover for the socket outlet and complete as reqd.
250Supplying and fixing 20 amps 415 volts, TPN industrial type, socket outlet with 4 pole earthing metal enclosure, metal plug top,along with 20 amps, 10 KA,TP MCB on surface or in recess with chained cover for the socket outlet and complete as reqd.
251Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete
252S & F metal enclosure for following capacity metal enclosure box on surface/recessed etc as reqd.(Make Legrand )
253100 Amp. TP MCCB
254160 Amp. FP MCCB
255DP/TP/FP MCB/ ELCB
256Supplying and fixing following way, Single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/ RCCB/ Isolator).
2576 way, Double door
2588 way, Double door
25912 way, Double door
26016 way, Double door
261Supplying and fixing following way, Horizontal type (PPI) triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/ RCCB/ Isolator).
2624 way (4 + 12), Double door
2636 way (4 + 18), Double door
2648 way (4 + 24), Double door
265Supplying and fixing following way, Vertical type triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. ( But without MCB/RCCB/Isolator).
2664 way (4 + 12), Double door
2678 way (4 + 24), Double door
26812 way (4 + 36), Double door
269Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
270For 6 way, Double door SPN MCBDB
271For 8 way, Double door SPN MCBDB
272For 10/12 way, Double door SPN MCBDB
273For 14/16 way, Double door SPN MCBDB
274Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board (Horizontal), 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
275For 4 way, Double door TPN MCBDB
276For 6 way, Double door TPN MCBDB
277For 8 way, Double door TPN MCBDB
278Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
279LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt): Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .
28018 watt
28130 watt
282LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ): Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector
2838 - 10 watt
28418 watt
285LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt): Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
28615 watt
28718 watt
28840 watt
289LED Batten light (System lumen efficacy ≥120 <135lm/Watt) :Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
29018-22 watt
29136 watt
29218-22 watt
29336 watt
294Supply,Installation,Testing and commissioning LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old complete as requiired.
295LED light fitting 20 watt with PC-Batten, Make_Havells or approved make
296LED light fitting 20 watt with AL-Batten, Make_Havells or approved make
297LED Ceiling Light 6 watt surface/recess mounting, FR-plastic housing, round/ square shape, Make_Havells or approved make
298LED Ceiling Light 12 watt surface/recess mounting, FR-plastic housing, round/ square shape, Make_Havells or approved make
299LED Ceiling Light 18/20 watt surface/recess mounting, FR-plastic housing, round/ square shape, Make_Havells or approved make
300LED light fitting (Integrated) 36 watt (surface/recess type) , 600X600 mm; Make_Havells or approved make
301LED light fitting (Integrated) 36 watt (surface/recess type) , 300X1200 mm; Make_Havells or approved make
302Wall bracket fitting complete, Make_Havells, code: LHFOAJE1TZ1I060, model Floretine WL 1LS B22 SS or approved make
303Wall bracket wooden base with 9 watt LED bulb (Decorative Cat. No.5990/L or equivalent approved make).
304Picture light fitting chrome 10W. (Make Philiphs (Cat.No 48043) or equivalent approved make
305LED Mirror Light 5 watt, 1 ft long; Make_Havells or approved make
306LED Mirror Light 10 watt, 2 ft long; Make_Havells or approved make
3073 watt spotlight Make_Havells or approved make
308LED skirting light 3-Module, Make_Legrand
309LED Bulkhead fitting 10 watt, 120 lm/W, IP65; Make_Havells or approved make
310LED Post Top Lantern 40 watt (Make_Crompton Cat.No.LPTO-40-CDL-M)
311Supply, Fixing,Testing and commissioning of following LED Tubes and lamps in existing old fittngs including connection etc. complete as required.
312LED PC Tube rod 20 watt,4 ft long, Make _Crompton
313LED Picture/candle lamp 2.7 watt pin/screw (E14/E27/B22 type) (Make_Havells,Philips or approved make)
314LED Picture/candle lamp 10 watt pin/screw (E14/E27/B22 type) (Make_Havells,Philips or approved make)
315LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).: Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
31625 watt
31736 watt
31845 watt
31972 watt
320LED Flood Light, powder coated pressure die cast aluminium (System umen efficacy >135lm/Watt): Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
321100 watt
322150 watt
323200 watt
324250 watt
325Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
3261 Output per phase and suitable for single phase supply
3271-output Astronomical Timer Switch complete as reqd. Make_Legrand Cat No. 4126 54
3282 Output per phase and suitable for single phase supply
3293 Output per phase and suitable for three phase supply
330Supply installation, testing and commissioning of 3-Ph,DOL Starter for 10 HP Motor, 415/440 volts,with sheet steel enclosure, type MN with SPP feature including drilling holes on the board, earthing etc. complete as reqd. (Make_ L&T (Cat no SS94351) or approved make.)
331Supply and fixing/mounting of outdoor type Pole box/ panel box with 1.6 mm thick MS body powder coated with extended MS hood over top for protection from rain water, having almirah type hinge and panel key type lock front door, openings for inlet and outlet of wire/cable at suitable locations complete as required.
332Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement :3 coarse sand:6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
333Above 4.5 meter and upto 6.5 meter
334Above 6.5 meter and upto 8.0 meter
335Above 8.0 meter and upto 10.0 meter
336Above 10.00 meter and upto 12.00 meter
337Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required
33832 mm dia
33940 mm dia
340Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
341Dismantling of pole / street light standard/ strut embeded in brick bllast foundation etc as required.
342Supply & fixing of 65 mm dia.'B' class GI pole 4.5 metre long for post top lantern i/c base plate 300 x 300 x 3mm GI reducer & nipple for mounting the fitting with painting etc. grouting in cement concrete 1: 3: 6 (1 cement : 3 coarse sand : 6 stone aggregate 40mm nominal size 0.4mm dia x 0.5 mm high to accommodate the looping) complete as reqd.
343Painting steel tubular / GI street light poles of following size with minimum two coats of good quality (approved Make) aluminium paint after cleaning the surface and rubbing the old paint etc. as required complete.
344up to 4.5 mtr. Long
345above 4.5 mtr. Upto 9 mtrs. Long
346Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size upto 35 sq.mm.
347direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
348In pipe
349In open duct
350On surface with MS clamp (clamped with 1mm thick saddle)
351Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size above 35 sqmm and upto 95 sq.mm.
352Direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
353In pipe
354In open duct
355On surface with MS clamp (clamped with 25 X3 mm MS flat clamp )
356Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size above 95 sqmm and upto 185 sqmm.
357Direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
358In pipe
359In open duct
360On surface with MS clamp (clamped with 25/40X3 mm MS flat clamp )
361Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size above 185 sqmm and upto 400 sqmm.
362Direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
363In pipe
364In open duct
365On surface with MS clamp (clamped with 40X3 mm MS flat clamp )
366Lifting & removing cable of any size from trench/ clamps on surface, making roll depositing the same in the store I/c cartage etc as reqd.
367Up to 35sqmm
368Above 35 to 95 Sqmm
369Above 95 to 185 Sqmm
370Above 185 to 400 Sqmm
371Digging cable trench, lifting brick & cable and relaying the cable of size upto 400 sqmm including refilling the same as required.
372Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted/welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
373Supply of one number PVC insulated & PVC sheathed/XLPE aluminium conductor steel armoured power cable of following sizes 1.1kV grade as per IS 7098 (part 1) 1988. Make_Havells or equivalent approved make
3742 x 10 sq.mm.
3752 x 16 sq.mm.
3763.5 x 25 sq.mm.
3773.5 x 35 sq.mm.
3783.5 x 50 sq.mm.
3793.5 x 70 sq.mm.
3803.5 x 95 sq.mm.
3813.5 x 120 sq.mm.
3823.5 x 150 sq.mm.
3833.5 x 185 sq.mm.
3843.5 x 240 sq.mm.
3853.5 x 300 sq.mm.
3863.5 x 400 sq.mm.
387Supply of following pairs telephone armoured cable (jelly filled) 0.5 mm tinned copper conductor in following manner as per specification complete as required of approved make.
388Jelly filled 5 pair 0.5 mm armoured telephone cable
389Jelly filled 10 pair 0.5 mm armoured telephone cable
390Jelly filled 20 pair 0.5 mm armoured telephone cable
391Jelly filled 50 pair 0.5 mm armoured telephone cable
392Jelly filled 100 pair 0.5 mm armoured telephone cable
393Supplying and making end termination with brass compression gland, aluminium lugs for following size of PVC insulated & PVC sheathed / XLPE aluminium cable of 1.1kV grade as reqd.
3942 x 6 sq.mm.
3952 x 10 sq.mm.
3962 x 16 sq.mm.
3972 x 25 sq.mm.
3983.5 x 25 sq.mm.
3993.5 x 35 sq.mm.
4003.5 x 50 sq.mm.
4013.5 x 70 sq.mm.
4023.5 x 95 sq.mm.
4033.5 x 120 sq.mm.
4043.5 x 150 sq.mm.
4053.5 x 185 sq.mm.
4063.5 x 240 sq.mm.
4073.5 x 300 sq.mm.
4083.5 x 400 sq.mm.
409Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
4102 x 16 sq.mm.
4112 x 25/35/50 sq.mm.
4123.5 x 25/35/50 sq.mm.
4133.5 x 70 sq.mm.
4143.5 x 95 sq.mm.
4153.5 x 120/150/185 sq.mm.
4163.5 x 240 sq.mm.
4173.5 x 300 sq.mm.
4183.5 x 400 sq.mm.
419Dismantling & refixing brass compression type cable gland of following size armoured cables complete as required..
420upto 50 sqmm
421Above 50 sqmm upto 120 sqmm
422Above 120sqmm upto 400 sqmm
423S&F, Copper tube / reducer/ lug terminals suitable for following size of conductor.
4246 /10/16 Sq.mm.
42525/35/50 Sq.mm.
426Earthing with G.I earth pipe 4.5 metre long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
427Earthing with GI earth plate size 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/ coke and salt as required.
428Providing & fixing 25mm x 5mm Copper strip in 40 mm dia GI pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required.
429Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode including connection with GI nut , bolt,spring washer excavation and refilling etc. as reqd.
430Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required
431Chemical Earthing with GI earth electrode 50 mm dia x 3 Mtr length with full GI strip including earth enhancing compound and RCC precast PIT cover and earthing pit etc as reqd.
432Providing & Fixing following strip on surface or in recessed for connection etc as reqd.
43325 mm x 5 mm copper strip
43425 mm x 5 mm G.I. strip
435Providing and fixing 6 SWG dia. GI wire on surface or in recess for loop earthing as reqd.
436Providing and fixing 6 SWG dia. GI wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit submain wiring/cable as required.
437Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing alongwith existing surface/ recessed conduit submain wiring/cable as required.
438Providing and fixing of lightning conductor final, made of 25 mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc.complete as required.
439Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run).
440Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for Vertical run)
441Fixing of copper / G.I. tape 20 mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required (For horizontal run).
442Fixing of copper / G.I. tape 20 mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required (for Vertical run).
443Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
4441200 mm
4451400 mm
446Supply, Installation, testing & commissioning of AC ceiling fan of following sweeps, aluminium die cast body , copper wound, double bearing, less 70 watts 220 volts 50 Hz without regulator I/c wiring the down rods of standard length up to 30 cm with 1.5 sq.mm. PVC insulated copper conductor single core cable etc as reqd. ( ISI marked.)
4471200 mm Make_Havells; model: ES-40
4481400 mm Make_Havells; model: Samrat HS
449Supply, fixing, testing and commissioning wall fan, 400 mm dia,1Ǿ AC power supply,50 Hz complete as required. Make_Havells, Model Swing NS Wall 4S (4 Star)
450SITC of wall mounting air circulator fan 450 mm dia,230 volts, 1400 rpm heavy duty,metal body including connecstion and fixing rag bolts complete as reqd. Make_Havells; Model Turboforce Wall Fan
451Supply, fixing, testing and commissioning domestic fresh air ventilation fan, of following dia,plastic body,1Ǿ AC power supply,50 Hz complete as required. Make_Havells; Model: Thrill Air DLX (New)
452150 mm dia, Make_Havells; Model: Ventil Air DXZ Neo
453200 mm dia, Make_Havells; Model: Thrill Air DLX (New)
454250 mm dia, Make_Havells; Model: Thrill Air DLX (New)
455Supply, Installation, testing and commissioning of exhaust fan of following sizes,1Ǿ AC power supply,50 Hz in the existing opening I/c connection, rag bolts complete as reqd. Make_Havells, model Turboforce Exhaust 1 phase 900 rpm
456300mm Make_Havells, model Turboforce Exhaust 1 phase 900 rpm
457380 mm Make_Havells, model Turboforce Exhaust 1 phase 900 rpm
458450 mm Make_Havells, model Turboforce Exhaust 1 phase 900 rpm
459600 mm Make_Havells, model Turboforce Exhaust 1 phase 900 rpm
460Supply and fixing of louver for exhaust fan of following sizes with rag bolts as reqd.
461Overhauling of ceiling fan of any size including dismantling and refixing of fan, bearings, checking/ cleaning the all parts, supplying & replacement of rubber seal, rubber rings, nut bolts, hanger clamps, bearing plates, cotter/ split pin, varnishing if reqd etc, reassembling, testing and commissioning of fan as reqd. complete.
462Overhauling exhaust fan of following size including opening and refitting of fan after checking ,cleaning all parts, bearing/ bush, greasing/ oiling including providing & replacement of defective rubber real, rings, nut,bolts ,washer ,hanger clamps ,bearing plates,cutter/split pin etc complete as required.
463upto 12\\" dia
46415\\" to 18\\" dia
465above 18\\" to 24\\" dia
466Overhauling of air-curtain of any size including dismantling and re-fitting the unit with rag bolts, checking, clening, oiling greasing, replacement of defective spares etc. (Extra cost will be paid against used new parts after submitted bill). reassembling the air curtain testing and commissioning as reqd..
467Cleaning of ceiling fan with detergent at site and replacement of damaged items i.e. rubber real, cutter pin, capacitor clamp, nut and bolts of hanger clamps etc as required.
468Normal height
469Extra height
470Cleaning of exhaust fan installed in kitchen/mess area up to 18\\"size including dismantling bearings, checking, cleaning, greasing, replacing rubber rings,nut bolts,hander clamps,bearing plates,cutter pin etc. if required reassembling, testing & commissioning complete as required.
471Normal height
472Extra height height
473Cleaning of air curtain of any size installed in kitchen/mess area including opening cabinet, bearings, checking, cleaning, greasing, replacing rubber rings,nut bolts,hander clamps,bearing plates,cutter pin etc. if required reassembling, testing & commissioning complete as required.
474Supply & Fixing of following size bearing in ceiling/exhaust/wall fans complete as required.
475Bearing No. 6201
476Bearing No. 6202
477Bearing No. 6203
478Bearing No. 6204
479Supplying and fixing capacitor of following rating suitable for ceiling fan / exhaust fan / air-curtain etc.
4802.5mfd
4814 or 5 mfd
4828 mfd
48310 mfd
484Repairing of housing for bearing side /bush side /in fan body in ceiling fan /exhaust fan /rally fan/ cabin fan/ pedestal fan/ water lifting pump/ air-circulator.
485Carriage of ceiling fan and regulator / exhaust fan from store to site as required.
486Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
487Providing and fixing extra conduit down rods of 20 mm dia. 2 x 10 cm length with 2 x 1.5 Sqmm FRLS PVC insulated copper conductor single core cable i/c painting etc. as reqd. (Note - More than 5 cm length shall be rounded nearest 10 cm & 5 cm or less shall be ignore)
488Fixing of geyser vertical/Horizontal type of capacity upto 50 ltrs including supplying and fixing of flexible pipe and nut/bolts/washers complete as required.
489Supply and Fixing of geyser vertical type of following capacity complete as required (Make_ Racold CDR/ Platinum or its equivalent make).
49025 litrs. Capacity
49150 litrs. Capacity
492Installation, testing and commissioning of heating element or backup element or thermostat or reset in hot water geyser including drain out water removing old and connecting new one complete as required.
493Supply of following heating elements for geyser complete required.
494Small Flange HE (sphere hot type) 2kw
495Triangular/ Broad Flange HE 2kw (Bajaj/USHA Lexus bend type)
496Heating element for Racold Platinum model (3200 watt) or equivalent approved make
497Heating element for Racold CDR DLX model (2000 watt) or equivalent approved make
498Supply of electrical back-up 3Kw ISI marked for solar hot water tank complete as reqd.
499Supply of following accessories for geyser complete required.
500Thermostat 7\\"/11\\" long.
501Thermal cut (reset) 7\\"/11\\" long
502Thermosat (Capillary type)
503Thermal cut (reset) with or without capillary
504Copper tube with outer dia 1/4 inch, wall thickness 25 SWG, hollow pipe for geyser connection as required.
505Supply of flexible pipe 1/2\\"
506Supply of Glass Incandescent Electric Water Heater Indicator
507Supply of Gyser Rubber Washer
508Dismantling of geyser of vertical/Horizontal type upto 50 litre capacity complete as required. And depositing the same in departmental store.
509Supply,installation, testing and commissioning 16 A key card switch 2 module. Make_Legrand_cat no.AC27110MW
510Supply,installation, testing and commissioning key fob for key card ; Make_Legrand cat no.679255
511Fixing Internet rack/ telephone DB of any size on surface/recessed including painting, making good with enamel paint etc. as reqd.
512Fixing of RJ-45 modular box with cover plate or I/o box for internet as required. ( box and cover plate will be supplied by dept.)
513on surface
514in recess
515S & F 3 mm thick phenolic laminated sheet on existing board with brass screw & cup washer etc as reqd.
516S & F bakelite sheet 5 mm thick complete with nut,bolts as reqd.
517Locating fault in the cable lines with meggar etc and rectifying removing & restoring the same and making good the damages etc as required.
518Locating fault in wiring rectifying removing & restoring supply the same & making good the damages etc as reqd.
519Providing 1/3 phase temporary service connection from supply source to desired place up to the lead/ cable 35 sq.mm. of 50 mtr. and disconnecting the same including to & fro cartage. ( extension board and cable will be supplied by the dept.)
520Laying of 1/2/3 run of UTP cable enhanced cat 5/cat 6 cable/optical fibre cable/ telephone cable in existing steel conduit pipe/GI pipe/ raceway / RCC pipe as reqd. the cost shall also include numbering of networking wire from room to rack as reqd. (wire will be supplied by dept)
521Supply & Laying of 32 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete.
522In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd.
523Laying charges In Pipe
524Laying charges On Surface
525Laying charges in open duct
526Supply & Laying of 40 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete.
527In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd.
528Laying charges In Pipe
529Laying charges On Surface
530Laying charges in open duct
531Supply & Laying of 50 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete.
532In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd.
533Laying charges In Pipe
534Laying charges On Surface
535Laying charges in open duct
536Dismantling and fixing/refixing of LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old complete as required.
537Upto 3 Meter
538Above 3 meter and upto 6 Meter
539Above 6 meter and upto 9 Meter
540Above 9 meter and upto 12 Meter
541Dismantling and re-fixing of any size ceiling fan/light fixture from following height complete including connection as required.
542Normal Height
543Extra Height
544Dismantling or refixing of exhaust fan of size 12\\"to 24\\" with required nut, bolts, washer, fasteners and rag bolts etc. as reqd.
545Dismantling or refixing of air-curtain of any size complete including electrical connection as required.
546Dismantling and refixing of wooden board of any sizes on surface or in recessed etc as reqd.
547Dismantling & refixing DB/TPN Switches upto 400A/ Busbar chamber/ M.S. boxes alongwith all accessories etc as reqd.
548Dismantling of rally fan / cabin fan/ ceiling fan/ light fitting from normal height and depositing in store as reqd.
549Dismantling the old MS/ PVC conduit pipe of all sizes from surface/recessed & making good the damages I/c filling the holes of the surface and depositing the same as reqd.
550Dismantling the old wood batten/PVC casing capping of all sizes from surface & making good the damages I/c filling the holes of the surface and depositing the same as reqd.
551Dismantling of old/damaged DB/ TPN switch Box etc. on surface/ recessed including making good and painting with enamel paint etc as reqd
552Dismantling of switch board/wooden/MS/PVC boxes of any size up to 250x300 mm on surface/ recessed including making good and painting with enamel paint etc as reqd and depositing the same in store as required.
553Dismantling, disconnecting 3x1.5/2.5/4.0/6.0/10.0 sqmm wire from existing conduit pipe casing and capping and making role and depositing in store as reqd.
554Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
555Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil cum
556Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
5571:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
558Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor level in all shapes and sizes in :
559Cement mortar 1:6 (1 cement : 6 coarse sand).
560Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
561Providing 12 mm cement plaster in fine sand of mix : 1:6 (1 cement: 6 fine sand) at all levels
562Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete.
563Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-incharge.e etc. as reqd
564Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar.
565Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand ) including trenching (75 cm deep) and refilling etc as required.
566100 mm dia
567150 mm dia
568250 mm dia
569300 mm dia
570Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
57140 mm dia
57250 mm dia
57365 mm dia
57480 mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57015042
AUTHORITY Government Departments
TENDER VALUE 34.92 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Annual Contract For Minor Works In Zone 5 & 6 Including Vh-1, Vh-2, Vh-Extension, Studio Apartment, Health Centre, Outreach Building, Type-1 Residential, Security Control Office, C Us School, Opportunity School, Swimming Pool, Laundromat, Chaupati, Ramleela Ground And Other Associated Buildings (Sh: Electrical Work).
Basic Detail
Tender No 40/EE/Elect/2026-27
Bidding Type Tender
Location
City Kanpur Nagar
State Uttar Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 34.92 Lakhs
Tender Fee Ref. Documents
EMD 69842
Exemption Not Available
Document List
BOQ_969087.xls
ef8bf724-3ecb-44be-996d-70291b993bd8.html
Tendernotice_1.pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_969087.xls

html

ef8bf724-3ecb-44be-996d-70291b993bd8.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders