Tender For Maintenance Of Completed Scheme At Uer I, Ii & Iiisub-Head : Repair Of Existing Street Light Network Of 80Mtr Row Uer-I From Nh-I To Western Yamuna Canal (Except Narela- Bawana Flyover).
Tender Value
1.03 Crore
Estimated cost
Bid Submission
25 Aug 2026
11 days left
EMD
2.06 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance Of Completed Scheme At Uer I, Ii & Iiisub-Head : Repair Of Existing Street Light Network Of 80Mtr Row Uer-I From Nh-I To Western Yamuna Canal (Except Narela- Bawana Flyover).
BOQ
| Sl. No. | Item Description |
| 1 | Supply, erection, testing and commissioning of HOT dip galvanized octagonal steel pole of 11 mtr. height and made out of 4 mm thick sheet, PCD 320 mm having bottom 200 mm A/F & top 100 mm A/F with built in connector box of size 500 mm x 120 mm with a ring of minimum 250 mm width made of 3 mm thick galvanized MS Sheet on window cover for anti-theft arrangement at 2500 mm height from base plate, MS base plate of size 320 mm x 320 mm x 20 mm thick on existing RCC foundation, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking, numbering of pole etc. complete as per drawing & technical specifications attached including following accessories mounted on inbuilt control box having flush cover with 2 Nos. mounting strips with tapped holes:-(a) 6 mm thick phenolic laminated sheet/bakelite sheet inside the window mounted on the existing mounting strips inside the flush door.(b) Supply & fixing 63 Amp terminal block suitable for 16 sq. mm conductor- 4 Nos. & shorting links-5 Nos. on DIN Channel i/c providing and fixing DIN channel of suitable length- 2 Nos. on existing laminated sheet.(c) Terminal suitable for 6 SWG GI Wire/1.5 sq. mm wire.(d) 6 Amp, SP MCB, 10 KA, ‘C’ Series-2 Nos. including mounting on DIN channel, earth stud 2 Nos. welded at suitable height i/c washers & nuts etc.(e) Suitable arrangement for saddling of incoming/outgoing cables i/c lugs/thimbles etc. as required.(f) Supply and fixing of 1500 mm long V shaped (not less than 60 degree) GI bracket made of 3.60 mm thick M.S pipe, B-class with top galvanized M.S tube of suitable dia. (as per site requirement) to accommodate the fittings on pole (to be installed at 11 mtr. height).(g) Connector box GI Cover with locking arrangement and GI round sleeve welded around cover box.NOTE:- Embosing / Laser printing of DDA Credentials as approved by Engineer-in-charge shall also be provided on the Octagonal Pole. |
| 2 | Providing and laying in position, M25 reinforced cement concrete foundation of size 750 mm long x 750 mm wide and 1800 mm deep i/c excavation of earth and PCC of min 300 mm thickness at bottom to avoid settling of soil and vertical erection angle, refilling the trench, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1960 mm long (approx.)-atleast 8 Nos. and reinforcement ring of cold twisted bar of 10 mm dia. 2800 mm long (approx.)-atleast 11 Nos. (With 150 mm spacing) with supply of 4 Nos. M-24 x 800 mm long plus 100 mm bent (150 mm top threaded portion whole galvanized portion) MS foundation bolts (L Type) & nuts (EN 8-grade) 4 Nos. and 4 Nos. washer per bolt, along with 2 Nos. templates/anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 26 mm dia. holes to match with PCD of pole and base plate including centering & shuttering as required positioning of foundation bolts and providing 75 mm (OD)-2 Nos. DWC pipe 1 mtr. long each for cable entry and exit with plastering & painting white & Black strip at the foundation above the ground level etc. complete as required |
| 3 | Supplying, Installation, Testing & Commissioning of 200 Watt LED Street light fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). NOTE:- 1. Embosing / Laser printing of DDA Credentials as approved by Engineer-in-charge shall also be provided. 2. The toughened glass shall be use for optical lens/glass cover. |
| 4 | Supply and replacement of existing single overhang bracket by aloft with hot dip galvanized double overhang bracket 1250 mm long made out of 48mm dia 'B' class G.I pipe thickness of suitable size canopy (min 400mm ) suitable to be fixed on the existing octagonal pole including supply and laying of 3CX2.5sq mm cu wire for connection of both LED fittings with supplying 6 mm thick phenolic laminated sheet/bakelite sheet inside the window mounted on the existing mounting strips inside the flush door with suitable SP MCB, 10 KA, ‘C’ Series-2 Nos. including mounting on DIN channel, earth stud 2 Nos. welded at suitable height i/c washers & nuts etc with hire of machinery for operating aloft with connection, testing, earthing etc complete as per the requirement for complete illumination of both carriage way.(including rebate of existing/ old bracket) |
| 5 | supply and replacement of existing single overhang bracket with hot dip galvanized elongated bracket arm 1250mm long made out of 48mm dia 'B' class G.I pipe thickness of suitable size canopy suitable to be fixed on the existing octagonal pole including supply and laying of 3C X 2.5 sq mm cu wire for connection of LED fitting with supplying 6 mm thick phenolic laminated sheet/bakelite sheet inside the window mounted on the existing mounting strips inside the flush door with provision of suitable SP MCB, 10 KA, ‘C’ Series-1 No. including mounting on DIN channel, earth stud 1 No. welded at suitable height i/c washers & nuts etc with hire of machinery for operating aloft with connection, testing, earthing etc complete as per the requirement for complete illumination of carriage way. (including rebate of existing / old bracket) |
| 6 | Supplying of following sizes of XLPE aluminium conductor armoured power cable of 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed. |
| 7 | 4*16 Sq.mm |
| 8 | 4 x 50 Sq.mm |
| 9 | Supplying and making End Termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 10 | 4x16 Sq.mm |
| 11 | 4x 50 Sq.mm |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 13 | Upto 35 Sq. mm |
| 14 | Above 35 sq.mm and upto 95 Sq.mm |
| 15 | Supplying, installation, testing & commissioning of floor mounted free standing type L.T. cubical Main Feeder Pillar duly compartmentalized (outdoor type) made out of 3 mm thick MS CRCA sheet with 4 nos. x 800 mm long legs made of M.S angle iron of size 40 mm x 40 mm x 5 mm thick along with frame & legs suitably grouted in foundation i/c connection, inter connection of the accessories mounted there on with suitable size of copper wire/strip with thimble/lugs, earthing the body of the feeder pillar i/c supplying & fixing of the following items and as per technical specification enclosed. (including rebate for the existing panel) 250 A, 36KA, FPMCCB (Ics= Icu)-1 No (incomer).100 A, 16KA, FPMCCB (Outgoing circuit) (Ics= Icu) - 6 Nos. 100 A, 30KA, FPMCCB (Outgoing circuit) (Ics= Icu) - 1 Nos.40 Amp 4P RCCB with 300mA senstivity and 40 Amp MCCB for upstream RCCB Volt meter (0-500V) 96 Sq.mm with selector switch – 1 SetAmp-meter (0-100A) 96Sq.mm with selector switch& 100/5 Amp ratio CTS – 1 SetIndication Lamp (RYB) LED type with contol SP MCB 6 Amp. - 1 set.TP contractor of AC-3 rating 110 Amp. 1 No.6 Amp single pole MCB -1 No. Auto/Manual toggle switch – 1 SetAstronomical Timer switch – 1 No.200 amp, 4 strip aluminium bus bar – 1 SetGland plate with gland – 1 setDanger Notice plate – 1 No.6 pin 15 Amp switch / socket outlet – 1 Set LED Lighting inside the feeder pillar Compartment having space for DISCOM energy meter with 6 mm thick backlite sheet for mounting energy meter.Surge Protection Device - 1 No.Note: Foundation shall be made as per site requirement for which nothing extra shall be paid. PCC- 1:2:4 (1 cement: 2 coarse sand: 4 graded stone) |
| 16 | Supplying, installation, testing & commissioning of floor mounted free standing type L.T. cubical Service Feeder Pillar duly compartmentalized (outdoor type) made out of 3 mm thick MS CRCA sheet with 4 nos. x 800 mm long legs made of M.S angle iron of size 40 mm x 40 mm x 5 mm thick along with frame & legs suitably grouted in foundation i/c connection, inter connection of the accessories mounted there on with suitable size of copper wire/strip with thimble/lugs, earthing the body of the feeder pillar i/c supplying & fixing of the following items and as per technical specification enclosed (including rebate for the existing panel). 125 A, 30KA, FPMCCB (Ics= Icu)-1 No (incomer).40 Amp 4P RCCB with 300mA senstivity and 40 Amp MCCB for upstream RCCB 63A, 16KA, FPMCCB (Outgoing circuit) (Ics= Icu) - 6 Nos. Volt meter (0-500V) 96 Sq.mm with selector switch – 1 SetAmp-meter (0-100A) 96Sq.mm with selector switch& 100/5 Amp ratio CTS – 1 SetIndication Lamp (RYB) LED type with contol SP MCB 6 Amp. - 1 set.TP contractor of AC-3 rating 110 Amp. 1 No.6 Amp single pole MCB -1 No. Auto/Manual toggle switch – 1 SetAstronomical Timer switch – 1 No.200 amp, 4 strip aluminium bus bar – 1 SetGland plate with gland – 1 setDanger Notice plate – 1 No.6 pin 15 Amp switch / socket outlet – 1 Set LED Lighting inside the feeder pillar Surge Protection Device - 1 No.Note: Foundation shall be made as per site requirement for which nothing extra shall be paid. PCC- 1:2:4 (1 cement: 2 coarse sand: 4 graded stone) |
| 17 | Fabricating, supplying and fixing of angle iron frame of suitable size to accomodate Main Feeder Pillar/Service Feedar Pillar fabricated out of 40 mm x 40 mm x 5 mm angle iron, and providing and fixing wire mesh of 8 SWG and shall be fixed and supported with 40 mm x 50 mm M.S. flats and the frame is to be grouted with M.S. angle legs not less than 30 cm in cement concrete 1:2:4 (1 cement :2 course sands and 4 stone aggregate 20 mm nominal size) foundation, painted with two coats of red oxide primer and two coats of synthetic enamel paint, and providing two leaf doors with 12 nos. hinges of size 75mmX60mmX3mm in front with two nos. sliding door bolt of size 30 mm X 16 mm and 2 nos. of godown lock for locking arrangement at top and Bottom both, complete etc. required. |
| 18 | supplying and installation of welded nut and strip assembly with MS allen screw inside the pole box suitable to lock the existing anti theft pole cover with allen screw perfectly to match the existing slot including on site welding of strip connection with allen screw and spot welding on covers at 2 points after complete connection etc as per requirement at site. |
| 19 | Earthing with G.I. earth Pipe 4.5 mtr long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required |
| 20 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required . |
| 21 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection etc. as required |
| 22 | Supply, boring and laying of HDPE pipe (ISI) marked of the 90 mm OD size confirming to IS:4984 with pressure rating of 6KG/Sq.cm by trench less technology with no dig. Method by making bore hole in horizontal direction across the road with boring equipment i/c jointing, cleaning, rodding of pipe performing mandrel test providing suitable covers on mouth of pipes, excavation of pits of required size & depth and laying of cables in the pipe. etc. complete as required. |
| 23 | Relocation of existing 11 mtr height street light pole along with foundation (after dislocation of poles with foundation) from the existing spot to a distance for safe excavation of the drain work with reconnection of the cables and excavation of new spot and laying the foundation and erection of pole with connection through the existing DWC of foundation and earthing, testing etc complete as per requirement at site. |
| 24 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender