Water Resources and Irrigation Boards / Undertakings / PSU Closing in 27 days TDR #57011339

Bids Are invited for Ductable Air Conditioner

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Sep 2026
27 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
665

Project Description

Bids Are invited for Ductable Air Conditioner Buy Back Existing Unit - Buyback With Dismantling Of All Existing Air Cooled Package Unit With Pumps, Piping And Cooling Tower Etc , New Ductable Ac Installation - Supply And Installation And Testing And Commissioning Of Advanced Micro Computer Based High Performance Machine Air Cooled Packaged Ductable Unit Of Minimum 8.5 Tr Capacity Having Indoor Airflow Capability Of 400Cfm Per Ton With Multiple Energy Efficient Scroll Compressors Inbuilt Electric Control Panel, First Charging Of R410 A Refrigerant Dx Cooling Coil Thermostatic Expansion Valve Air Filter And Blower Section Blower With Motor Coils Initial Charge Of Compressor Oil.Capacity Minimum 8.5 Tr Or Min. 400 Cfm Tr Make Bluestar Or Trane Or Carrier Or York Or Voltas Or O General , Suction Line - Supply And Installation Of Hard Drawn Refrigerant Copper Piping With Nitrile Insulation On Suction Line. Make Hariom Or Mandev Or Maxflow Or Indigo Or Mrajco Insulation Armacell Or Aflex Or Supreme. Suction Line As Per Oem , Liquid Line , Acoustic Line - Supplying And Fixing Of Acoustic Lining With Open Cell Nitrile Rubber Having Thickness Of 15Mm.Make Supreme Or Aerofoam Or A-Flex Or Armacell , Canvass Connection - Supply And Fixing Of Canvass Connection. , Drain Pipe - Supply And Installation Of Upvc Drain Pipe.Make Supreme Or Astral Or Prince (32 Mm To 50Mm) , Frls And Control Cables - Supply And Installation Of Frls Control Cable Pvc Insulated Pvc Sheathed Steel Armoured Multistrand Copper Conductor Control Cable Following Size. Make Finolexor Rr Or Havells Or Kei Or Polycab 6 Core X 2.5 Sqmm , Lt Copper Cable - Supplying Laying Of Xlpe Insulated Pvc Sheathed Steel Armoured 1.1Kv Grade Lt Copper Conductor Power Cable Make Finolex Or Rr Or Havells Or Kei Or Polycab 4.0 Core X 2.5 Sqmm , Gi Wire - Providing And Fixing 8 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required At Site. , Stand For Outdoor Unit - Supply And Installation Of Ms Stand For Outdoor Units. , Stand For Indoor Unit - Supply And Installation Of Ms Stand For Indoor Units. , Refrigerant Gas - Supply & Charging Of Extra Refrigerant Gas R410 A , Testing - Nitrogen Testing, Vacuumizing And Gas Charging. , Electrical Distribution Panel - Design And Fabrication And Supply And Installation Of Cubical Type Dead Front Electrical Distribution Panel Made Out Of 14G Crca Sheet With Suitable Mccbs, Tpn And Internal Wiring Etc. And Instrumentation For Minimum 11 Tr X 4 Nos Package Units As Per Standard Make. The Unit Shall Have Sequential Controller For Operating 3 Units. Note All The Switchgears Installed In The Electrical Distribution Panel Of Air-Conditioning Units Shall Be Of Abb Or Siemens Or Schneider Or L&T Or Teknic Make

BOQ

Sl. No. Item TitleItem Description
1Buy back existing unitBuyback with Dismantling of all existing air cooled package unit with pumps, piping and cooling tower etc
2New Ductable AC installationSupply and Installation and Testing and commissioning of advanced micro computer based high performance machine air Cooled Packaged Ductable Unit of minimum 8.5 TR capacity having indoor airflow capability of 400CFM per Ton with multiple energy efficient Scroll Compressors inbuilt electric control panel, first charging of R410 A refrigerant DX cooling coil thermostatic expansion valve air filter and blower section blower with motor coils initial charge of compressor oil.Capacity minimum 8.5 TR or Min. 400 CFM TR Make Bluestar or Trane or Carrier or York or Voltas or O General
3Suction LineSupply and Installation of hard drawn refrigerant Copper Piping with nitrile insulation on suction line. Make Hariom or Mandev or Maxflow or Indigo or Mrajco Insulation Armacell or Aflex or Supreme. Suction line as per OEM
4Liquid LineLiquid line as per OEM
5Acoustic lineSupplying and fixing of acoustic lining with open cell nitrile rubber having thickness of 15mm.Make Supreme or Aerofoam or A-flex or Armacell
6Canvass connectionSupply and Fixing of Canvass Connection.
7Drain PipeSupply and Installation of UPVC Drain Pipe.Make Supreme or Astral or Prince (32 mm to 50mm)
8FRLS and control cablesSupply and installation of FRLS control cable PVC insulated PVC sheathed Steel armoured multistrand copper conductor control cable following size. Make Finolexor RR or Havells or KEI or Polycab 6 Core x 2.5 Sqmm
9LT copper cableSupplying laying of XLPE insulated PVC sheathed steel armoured 1.1KV Grade LT Copper Conductor power cable Make Finolex or RR or Havells or KEI or Polycab 4.0 Core x 2.5 Sqmm
10GI wireProviding and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required at site.
11Stand for outdoor unitSupply and installation of MS stand for outdoor units.
12Stand for indoor unitSupply and installation of MS stand for indoor units.
13Refrigerant gasSupply & charging of extra Refrigerant gas R410 A
14TestingNitrogen testing, vacuumizing and gas charging.
15Electrical distribution panelDesign and fabrication and supply and installation of cubical type dead front Electrical distribution Panel made out of 14G CRCA sheet with suitable MCCBs, TPN and internal wiring etc. and instrumentation for minimum 11 TR X 4 Nos Package units as per standard make. The unit shall have sequential controller for operating 3 units. Note All the switchgears installed in the Electrical distribution panel of air-conditioning units shall be of ABB or SIEMENS or SCHNEIDER or L&T or TEKNIC make

AI Tender Summary

OUR REF NO 57011339
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 11-09-2026
Authority
Authority Name Bhakra Beas Management Board
Work Description Bids Are invited for Ductable Air Conditioner Buy Back Existing Unit - Buyback With Dismantling Of All Existing Air Cooled Package Unit With Pumps, Piping And Cooling Tower Etc , New Ductable Ac Installation - Supply And Installation And Testing And Commissioning Of Advanced Micro Computer Based High Performance Machine Air Cooled Packaged Ductable Unit Of Minimum 8.5 Tr Capacity Having Indoor Airflow Capability Of 400Cfm Per Ton With Multiple Energy Efficient Scroll Compressors Inbuilt Electric Control Panel, First Charging Of R410 A Refrigerant Dx Cooling Coil Thermostatic Expansion Valve Air Filter And Blower Section Blower With Motor Coils Initial Charge Of Compressor Oil.Capacity Minimum 8.5 Tr Or Min. 400 Cfm Tr Make Bluestar Or Trane Or Carrier Or York Or Voltas Or O General , Suction Line - Supply And Installation Of Hard Drawn Refrigerant Copper Piping With Nitrile Insulation On Suction Line. Make Hariom Or Mandev Or Maxflow Or Indigo Or Mrajco Insulation Armacell Or Aflex Or Supreme. Suction Line As Per Oem , Liquid Line , Acoustic Line - Supplying And Fixing Of Acoustic Lining With Open Cell Nitrile Rubber Having Thickness Of 15Mm.Make Supreme Or Aerofoam Or A-Flex Or Armacell , Canvass Connection - Supply And Fixing Of Canvass Connection. , Drain Pipe - Supply And Installation Of Upvc Drain Pipe.Make Supreme Or Astral Or Prince (32 Mm To 50Mm) , Frls And Control Cables - Supply And Installation Of Frls Control Cable Pvc Insulated Pvc Sheathed Steel Armoured Multistrand Copper Conductor Control Cable Following Size. Make Finolexor Rr Or Havells Or Kei Or Polycab 6 Core X 2.5 Sqmm , Lt Copper Cable - Supplying Laying Of Xlpe Insulated Pvc Sheathed Steel Armoured 1.1Kv Grade Lt Copper Conductor Power Cable Make Finolex Or Rr Or Havells Or Kei Or Polycab 4.0 Core X 2.5 Sqmm , Gi Wire - Providing And Fixing 8 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required At Site. , Stand For Outdoor Unit - Supply And Installation Of Ms Stand For Outdoor Units. , Stand For Indoor Unit - Supply And Installation Of Ms Stand For Indoor Units. , Refrigerant Gas - Supply & Charging Of Extra Refrigerant Gas R410 A , Testing - Nitrogen Testing, Vacuumizing And Gas Charging. , Electrical Distribution Panel - Design And Fabrication And Supply And Installation Of Cubical Type Dead Front Electrical Distribution Panel Made Out Of 14G Crca Sheet With Suitable Mccbs, Tpn And Internal Wiring Etc. And Instrumentation For Minimum 11 Tr X 4 Nos Package Units As Per Standard Make. The Unit Shall Have Sequential Controller For Operating 3 Units. Note All The Switchgears Installed In The Electrical Distribution Panel Of Air-Conditioning Units Shall Be Of Abb Or Siemens Or Schneider Or L&T Or Teknic Make
Basic Detail
Tender No GEM/2026/B/7914910
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 14 Aug 2026
Submission Date 11 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
f575b47b-167e-445c-87ed-423f57660a32.pdf
9752927_Boq_1.xlsx
ATC_f502aa48-afe7-47a0-abf61786683217284_xenomdlh1.pdf
item_specification_docs_2026-08-13-16-01-23_ac938fe53cf0ec6622ac24e4cac82b09.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
pdf

f575b47b-167e-445c-87ed-423f57660a32.pdf

xlsx

9752927_Boq_1.xlsx

pdf

ATC_f502aa48-afe7-47a0-abf61786683217284_xenomdlh1.pdf

pdf

item_specification_docs_2026-08-13-16-01-23_ac938fe53cf0ec6622ac24e4cac82b09.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders