Tender For Supply Installation Testing and Commissioning of Fire Hydrant System, Fire Sprinkler System, Addressable Fire Alarm System And Flooding System Including Iei & Eei To Fire Pump House Building Also Providing Emergency Led Lighting And Led Ex
Tender Overview
Project Description
Tender for Supply Installation Testing and Commissioning of Fire Hydrant System, Fire Sprinkler System, Addressable Fire Alarm System And Flooding System Including Iei & Eei To Fire Pump House Building Also Providing Emergency Led Lighting And Led Exit Signages In Gb Pant Hospital Building Under Sd-I,Wsd,Apwd, Sri Vijaya Puram
BOQ
| Sl. No. | Item Description |
| 1 | Fire Hydrant and Sprinkler systemProviding and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 2 | Providing, laying, testing & commissioning of 'B' class medium G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the ground surface/ wall/ceiling with suitable clamp or support frame and painting with one coat of Anti corrosive bituminious paint and two coats of synthetic enamel paint of colour Post office red of required shade complete as required : |
| 3 | a) 25mm |
| 4 | b) 32mm |
| 5 | c) 40mm |
| 6 | d) 50mm |
| 7 | e) 65mm |
| 8 | f) 80mm |
| 9 | g) 100mm |
| 10 | h) 150mm |
| 11 | Providing, laying, testing & commissioning of 150mm 'B' class medium G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and painting with two or more coats of Anti corrosive bituminious paint and lay directly in ground (50 cm below) including excavation and refilling the trench complete as required. |
| 12 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal cap and chain as required Similar to make Agni , Zoloto, or its equivalent. |
| 13 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal cap and chain as required Similar to make Agni , Zoloto or its equivalent. |
| 14 | Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required Similar to make Kartar , Zoloto, or its equivalent. |
| 15 | a) 65mm |
| 16 | b) 80mm |
| 17 | c) 100mm |
| 18 | d) 150mm |
| 19 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required Similar to make Kartar , Zoloto, or its equivalent.. |
| 20 | a) 100mm |
| 21 | b) 150 mm |
| 22 | Providing, installation, testing and commissioning of Ball valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required Similar to make Kartar , Zoloto, or its equivalent. |
| 23 | a) 32 mm |
| 24 | b) 40mm |
| 25 | c) 50mm |
| 26 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.7Kg/cm2 complete as required. |
| 27 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required Similar to make Kartar , Zoloto, or its equivalent. |
| 28 | a) 80mm |
| 29 | b) 100mm |
| 30 | c) 150mm |
| 31 | Providing, installation, testing and commissioning ofstainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange Similar to make Kartar , Zoloto, or its equivalent.. |
| 32 | a) 150 mm |
| 33 | Provioding and fixing Wall mounted Double door M.S. Fire Hose Cabinet made out of 20 SWG Gauge M.S. Sheet including 02 Nos. 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings with Branch pipe 63 mm dia with 20 mm nominal internal diameter nozzle (Gun metal) duly bound with GI wire, rivets etc. conforming to IS 636 (type-A). The Cabinet door shall have front glass with lock and key arrangement and shall be painted with post office RED colour Similar to Life guard or its equivalent. |
| 34 | Provioding and fixing Double door M.S. Fire Hose Cabinet made out of 20 SWG Gauge M.S. Sheet including 02 Nos. 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings with Branch pipe 63 mm dia with 20 mm nominal internal diameter nozzle (Gun metal) duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) installed at Outdoor side near landing valve by using fabricated MS Angle Stand of reqiured size as per the direction of E in C . The cabinet door shall have front glass with lock and key arrangement and shall be painted with post office RED colour Similar to Life guard or its equivalent. |
| 35 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 36 | a) 40mm |
| 37 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : |
| 38 | a) 4 way - 150 mm dia M.S. Pipe |
| 39 | Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shadeas required. |
| 40 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : |
| 41 | a) Pendent Sprinkler |
| 42 | b) Horizontal side wall sprinkler |
| 43 | Supplying, installation, testing and commissioning of DSM 80/36 Electric driven Main Fire Pump suitable for automatic operation and produce 1620 lpm at 70 m Head and consisting of Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520 coupled with 37 Kw or 50 HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM along with star delta starter control panel, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
| 44 | Supplying ,installation, testing and Commissioning of DSM 80/36 diesel engine driven main fire pump suitable for automatic operation ,produce 1620 lpm at 70 m Head consisiting of horizontal type,multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520 coupled with 52 HP 1500 RPM water cooled with radiator, diesel engine make: KOEL conforming to relevant IS standard complete with auto starting mechanism ,12/24 volts electric starting equipment,diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding , residential silencer, instruments and protection as per standard specification,stop solenoid for auto stop in the event of fault with audio indications,painted with post office red colour etc. as required. M.S. fabricated common base plate,coupling,coupling guard,foundation bolts etc. as required. |
| 45 | Supplying, installation, testing and commissioning of 5.5 kw electric driven pressurisation pump suitable for automatic operation and produce 180lpm at 70 m consisting of Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. coupled with 10 HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
| 46 | Fabrication, supply , installation testing & commissioning of Electrical control pannel of cubical construction of dimesnsion 2.0m x 1,5m x 0.5m , floor mounted type, fabricated out of 2 mm thick CRCA sheet compartmentalised with both side open i/c front & back double hang shutter with locking arrangement , dust and vermin proof , cable alley, intrconnectin with suitable size copper conductor cable/solid copper strip, main incoming 250A,50kA 4 pole MCCB, Digital Voltmeter 0-500V with selector switch,pressure switch (03 Nos.) Digital Ammeter (0-250A) with selector switch &CTsetc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of copper Bus Bar 300A, with fully automatic star/delta starter suitable for main electric and jockey pump with 100 amps and 25Amps MCCB 50 kA and overload proctection, current sensing type single phase preventor, Battery charger suitable for 12V/24 V DC with boost and trickle selector switch ,0-30V DC volt meter, and 0-20A DC Ammeter all standard relays complete with all accessories and internal wiring required for automatic operation selector switch for local/remote,auto/manual/ OFF operation as per the direction of E in C in complete in all respect and system controller to control operation of main electric fire pump,Jockey pump, diesel pump in sequence as per speification consisting of following relays, timers. SensorsPressure switch, annunciation window for fault indication complete as per CPWD specification suitable for operation an 415V, 3 phase , 50Hz Ac supply with enclosure protection class IP 42 as required: |
| 47 | Supplying and Fixing of Pressure Gauge of rating upto 300 PSI or 20 kg/cm2 of reputed make in the existing Fire Hydrent line complete as required |
| 48 | Fire Alarm SystemSupplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 49 | SITC of Analogue Addressable Fire Alarm Panel UL864 9th Edition, which consists of a display board that will have a minimum 160-character display with a touch keypad, a mother board that will have an ARM Cortex M3 32-bit processor, Inbuilt RS-485 Networking Circuit for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the Configuration tools, minimum Two inbuilt programmable inputs, Two inbuilt NAC's, and Three Programmable Relays and 4 Loop Card circuits and loop card builtin Panel. power Supply Board, which will have SMPS fully protected board, which its operates on 120 to 220V AC ± 10%, 50/60 Hz, battery backup 24V DC (02 Nos. Battery 12V 7AH) with built-in charger. the panel have IP-50 rating Optional: for BMS integration thru MODBUS converter, Graphical Software, Software for TCP/IP Module, provision for GSM based Auto dialer, provision for printer thru compatible module, Make Ravel : UL approved. |
| 50 | SITC of Loop Card which will have 254 devices of both detectors and modules in a single line circuit on any combination, SLC should supports both Class A and Class B wiring.Shall have an LED indication for FIRE,Normal and Redundancy conditions, Make: Ravel Make: Ravel, Model Avani-LCS or its equivalent. |
| 51 | SITC of Addressable Active Repeater panel having inbuilt RS-485 Networking Circuit for peer to peer networking, LCD character display with touch screen or other keypad for inbuilt reset, acknowledge and silence switches, power supply unit (230 ± 5% V, 50 hz), provision for battery backup 24V DC (02 Nos. Battery 12V 7AH) with built-in-charger, complete as required including necessary programming and configuration. Make: Ravel, Model No. RE-517RP or its equivalent. |
| 52 | SITC of Analogue Addressable Smoke detector with base with Binary coded address setting Dual LED’s for 360° visibility. Polarity Free, Sleek low-profile housing design. Regular 100mm base. IP Rating: IP - 42. Make: Ravel No. RE 317D - SL or its equivalent. |
| 53 | SITC of Analogue Addressable Heat detector with base, Fixed temperature of 59°C and ROR feature to raise an alarm when the temperatures raises 11.1°per Minute ,Shall have Binary coded addressing.Dual LED’s for 360° visibility. Non-Polarized, Sleek low-profile housing design. Regular 100mm base. IP Rating: IP - 42. Make: Ravel RE 317D - HL or its equivalent. |
| 54 | SITC of Analogue Addressable Manual Pull Station -Double Action- with back box and Break Glass Rod, shall be resettable by Align key to avoid unauthenticated restorations, monitoring the field NO/NC devices,Mini Monitor Module with back box Shall have Binary Coding Setting Dip Switch, Make: Ravel, Model No. RE-716P-IT or its equivalent. |
| 55 | SITC of Sounder cum Strobe 24VDC operated complete with mounting back boxes, all connections, etc. as required on wall/ ceiling/ false ceiling. Make: Ravel RE-716SS or its equivalent. |
| 56 | SITC of Addressable Control Module for activating the Notification application devices. Shall have supervisory facility to supervise the auxiliary power Supply as well as the Notification Appliance Circuits. Shall have Binary Coding Setting dip switches, Shall have an LED indication for normal working and active Modes. Make: Ravel, Model No. RE-717MC or its equivalent. |
| 57 | SITC of Addressable Monitor Module complete as required. Make: RavelUI , Model No. RE-717MM or its equivalent. |
| 58 | SITC of Fault isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected. Make: Ravel , Model No. RE-717MI or its equivalent. |
| 59 | Supply and Fixing of Industrial Electric Siren- 1.0 Km sound range, 230VAC operated complete with suitable power supply cable and plugtop, mounted on the wall/ base with suitable mounting accessories, etc. as required and as directed at site Make: Kheraj or its equivalent. . |
| 60 | Supplying, installation, testing and commissioning of Power Supply Panel operating on 220VAC supply , output 24VDC at 2 Amps and provision for battery backup 24V DC(02 Nos. Battery 12V 7 AH) with built-in-charger complete with all connections, etc. as required. Make: Ravel, Model No. RE-2APS or its equivalent. |
| 61 | Supply of Response Indicator Alarm status is indicated By Red color LED, Operates on 12V DC, Dual LED’s for 360deg visibility, Flush / Ceiling wall mount, Operating Voltage : 12V D.C, Operating Current : 10mA, Alarm Indication : RED LED . Make: Ravel, Model No. RE-RI or its equivalent. |
| 62 | SITC of Microprocessor based CE Mark Agent release panel has dual function of detection and the system has 16X2 LCD character, 2 zones detection circuit with battery backup 24V DC (02 Nos. Battery 12V 7AH) with built-in charger. and One main and standby agent release circuit,having logic programmable options, RTC facility, Auto & manual operational facility,Three 24V Sounder Output (Fire, after Cross zone, after gas release),RS 485 Output for Repeater, solenoid output with ON and OFF timer, programmable Main / standby cylinder output facility, gas inhabit and instant release, manual release with time delay or without time delay and pressure low sensing facility.Battery polarity & Deep discharge protection , safety features to prevent accidental release. Make: Ravel, Model No. RE-120 GR or its equivalent. |
| 63 | Supplying, installation, testing & commissioning of following colour Manual Call Point for abort and emergency release of gas in Gas release suppression system complete with mounting box, all connections etc. as required. Make: Ravel, Model No. RE-716MY & RE-716MG or its equivalent. |
| 64 | a) MCP (Yellow) |
| 65 | b) MCP (Green) |
| 66 | Supplying and fixing of Clean Agent Fire Extinguisher of Capacity 6 Kg complete with brass forged squeeze grip type valve and filled with clean agent gas environmental friendly Rating 2A AND 34B confirming to IS 15683 with ISI Mark. Make : Fyrax or its equivalent. |
| 67 | Supplying of LED Emergency Batten type Tube fitting of 20Watt similar to Bajaj Ledz Inverter batten or its equivalent. |
| 68 | Supplying and fixing of ceiling/wall mouting type Industrail LED based emergency Fire Exit light with two head lamps and battery backup upto 4 Hrs and IP 20 rating having Mains on Indication and protection over deep, similar to Make : Fine tech system or its equivalent. |
| 69 | Supplying and fixing of ceiling/wall mouting type LED based Double side emergency Fire Exit light with green white background and battery backup upto 4 Hrs and IP 20 rating having Mains on Indication and protection over deep, similar to Make : Fine tech system or its equivalent. |
| 70 | IEI & EEI PartWiring for light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch , modular plate , suitable GI box and earthing the point with 1.5 sqmm.FRLS PVC insulated copper conducotor single core cable etc. as required . |
| 71 | a) Group-C |
| 72 | Wiring for Light/ power plug wiring with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reqd. |
| 73 | Wiring for Circuit/ sub main Wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as reqd. |
| 74 | a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm. earth wire |
| 75 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ reccessed steel/ PVC conduit as required. |
| 76 | a) 2x1.5 sq.mm |
| 77 | Supplying and fixing following sizes of conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of ressed conduit as required. |
| 78 | a) 20mm. |
| 79 | b) 25mm. |
| 80 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 81 | a) 5/6 A switch |
| 82 | b) 15/16 A switch |
| 83 | c) 3 pin 5/6 A socket outlet |
| 84 | d) 6 pin 15/16 A socket outlet |
| 85 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 86 | a) 6 Module (200 mmX75 mm) |
| 87 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch, connections etc. as required. |
| 88 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 89 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required. |
| 90 | Installation, testing and commissioning of wall barcket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 91 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. |
| 92 | a) Upto 450 mm |
| 93 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board , 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection , powder painted including, earthing etc as required. (But without MCB/RCCB/Isolator). |
| 94 | a) 4 way (4 + 12), Double door |
| 95 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 96 | a) Single Pole |
| 97 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing andcommissioning etc. as required |
| 98 | a) 40 A |
| 99 | Supplying and Fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 100 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 101 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 102 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on the wall surface as required. |
| 103 | a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 104 | b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 105 | c) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 106 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 107 | a) 3.5 X 35 sq. mm (35mm) |
| 108 | b) 3.5 X 95 sq. mm (45mm) |
| 109 | c) 3.5 X 185 sq. mm (57mm) |
| 110 | Supplying of 12W LED, 6000K surface decorative wall / ceiling mounted LED Bulk head fittings similar to Luker, cat no. LBKOVSL 12 its equivalent. |
| 111 | Supplying and fixing of 40 W, 6000K(WH) Industrail Low bay indoor light having IP40, CRI> 80,beam angle 120 degree complete with connection similar to LUKER AVIOR Highbay Industrail light of product code LHBYC40 or its equivalent. |
| 112 | Supplying of Exhaust Fan of 450 mm sweep , Make:- Havells, Model No.-Turbo Force Neo 1PGrey or equivalent. |
| 113 | Supplying of following sizes XLPE insulated PVC outer sheathed with galvanised round steel wire or steel srtip armoured aluminium conductor power cable of 1.1 Kv grade conforming to IS 7098 (Part-I) 1988 amended upto date. |
| 114 | a) 3.5 core X 35 sq. mm |
| 115 | b) 3.5 core X 95 sq. mm |
| 116 | c) 3.5 core X 185 sq. mm |
| 117 | Supplyingh and laying of following size DWC HDPE pipe ISI marked alomg with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. |
| 118 | a) 63 mm dia (OD-63 mm & ID-50 mm nominal) |
| 119 | b) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 120 | Supplying and laying of DWC HDPE pipe of following size with ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 16205 (Part 24): 2018/IS 14930 (Part 2) : 2001, complete with fitting and cutting, jointing etc. on surface/wall including providing clamping arrangement etc as required. |
| 121 | a) 63 mm dia (OD-63 mm & ID-50 mm nominal) |
| 122 | b) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 123 | Supplyingh and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in the existing masonary open duct etc. complete as required. |
| 124 | a) 63 mm dia (OD-63 mm & ID-50 mm nominal) |
| 125 | b) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 126 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1.KV grade of following size in the existing DWC/PVC/RCC/ HUME/GI/METAL pipe as required. |
| 127 | a) Upto 35 sq.mm |
| 128 | b) Above 35 sq.mm and upto 95 sq.mm |
| 129 | c) Above 95 sq.mm and upto 185 sq.mm |
| 130 | Demolishing cement concrete/ bituminous road manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. trench. |
| 131 | Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete trench , but excluding DWC /GI Pipe dia. |
| 132 | Supplying and fixing of TPN On load change over switch of 200 Amps similar to Havells Cat No.IHBFFE0200 or its equivalent including complete with neccesaary connection etc as required. |
| 133 | Supplying and fixing of 200Amps FP MCCB ,36kA including sheet steel enclosure with necessary connection etc. as required Similar to Havells Cat no. IHLLSEB40250& IHEGFP or its equivalent. |
| 134 | Providing Earthing with safe earthing electrode of galvanization 80 to 100 microns length 2000 mm, 48mm dia and inner space to be filled with crystaline conuctive mixture including filling - up with electrodite (Back fill Compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arragement etc. as required. (Similar to ASHLOK make SEE brand safe earthing or equivalent) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender