Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #57010951

Tender For Repair/ Replacement Of Street Light, Security Lights Including Bollard Lights At Zone A And Repair/Replacement Of Internal Electrification Including Db,Mcbs,Lights,Ceiling Fans,Exhaust Fans And Geysters At Zone A And Comprehensive Maintena

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
47 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
13 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Street Light, Security Lights Including Bollard Lights At Zone A And Repair/Replacement Of Internal Electrification Including Db,Mcbs,Lights,Ceiling Fans,Exhaust Fans And Geysters At Zone A And Comprehensive Maintenance Of Fire Fighting Alarm System At Various Location Under Ge(Navy) Chennai

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF STREET LIGHT, SECURITY LIGHTS INCLUDING BOLLARD LIGHTS AT ZONE A AND REPAIR/REPLACEMENT OF INTERNAL ELECTRIFICATION INCLUDING DB,MCBs,LIGHTS,CEILING FANS,EXHAUST FANS AND GEYSTERS AT ZONE A AND COMPREHENSIVE MAINT OF FIRE FIGHTING ALARM SYSTEM AT VARIOUS LOCATION UNDER GE(NAVY) CHENNAI
Sl. No. Item Description
1Taking down old unserviceable street light / post top lantern / security light/Bollards fitting luminaires from pole/Bldg/gate, of any type / capacity and taking the item into credit complete all as specfied and directed.
2Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high ressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
3Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
4Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
5Supply and fixing LED flood light 500 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
6Supply and fixing energy efficient LED security light fitting, 25W or nearest higher wattage, 230V, IP66, with pressure die cast aluminium housing and integral electronic driver including all accessories internally pre wired complete and connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories complete all as specified and as directed. Make: Havells ENDURASUNDOWNSL25WLED765PASYBOPCIHD or equivalent in Philips/Bajaj/ Wipro/CG
7Supply and fixing post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
8Supply and fixing 40 watt smart bright integrated solar street light with lithium Ferro Phosphate battery, solar panel and charger built into the luminaire. Both Pole and wall mounting system with bracket. Microwave based motion sensor for optimizing battery autonomy complete all as specified and directed.Make : Philips Cat Part No BRC010LED40/765 or equivalent in Havells/Bajaj/ Wipro/CG
9Supply and fixing decorative type of LED BOLLARD light of 10 Watts or nearest higher capacity LED type resistance to impact & corrosion, IP 66 protection, heat sink, system efficiency > 100 lmn/ W, CRI between 80-90, color temp 5000-6000 K, complete with LEDs and Driver and supporting base of 2-3 feet all as specified & directed.Make : Crompton cat pat no.LBLA1-10-CDL(MAYA I) / equivalent in Philips/Bajaj/ Wipro/ Havells
10Supply and fixing in repairs electronic driver, suitable for 100 Watts LED or nearest higher capacity street light fittings /flood light fitting all as specified and as directed.Make: Bajaj/Wipro/Havells/C&S/Crompton/Phillips.
11Supply and fixing in repairs electronic driver, suitable for 150 Watts LED or nearest higher capacity street light fittings /flood light fitting all as specified and as directed.Make: Bajaj/Wipro/Havells /C&S/CG/Phillips.
12Supply and fix new GI bracket made out of 25/32/40mm dia GI pipe length 1.2 mtr long bent to an angle 135 degree including two coats of aluminium paint over a coat of zinc chromate primer along with clamps, bolts, nuts etc including removing old unserviceable GI bracket complete all as specified.
13Supply and fix weather proof looping in box PVC without side dimension 160 x160x105 mm comprising of connector and MCB SP 6-32 A including mounting arrangements and lugs etc.and removing existing defective looping box and taken as credit complete all as specified and as directed. Make :Sintex/Hensel or as specified in PS
14Cutting the road / hard standing for laying of pipes / cable in trenches and making good with PCC 1 :2 :4 Type B1 complete and painting with black paint , if necessary, to match with existing bituminous road colour complete all as specified and as directed by the Engineer-in-Charge .
15Material and labour for providing plain cement concrete 1:3:6, type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete all as specified and as directed.
16Material and labour for providing plain cement concrete 1:2:4, type B2 using 40mm graded stone aggregate as in foundations, filling and mass concrete all as specified and as directed.
17M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to earth using GI earth wire 4mm dia by means of nuts, bolts and washer and check nuts of GI or steel connected to main DB/Panel/equipments including necessary earth work and excavation and including PCC chamber with 1:3:6 type C-2 and cover using steel sheet 3 mm thick with handle and frame of angle iron 25x25x5mm, GI medium grade 15mm bore pipe for watering common salt charcoal, funnel wiremesh and earth test point terminal block and testing on completion all as specified and or shown in electrical plate No 3 of SSR Pt-I and testing of earth resistance as required.Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
18Supply and lay earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth wire 4mm dia complete all as specified and as directed.
19Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtr deep in hard /dense soil for laying underground cables, laying pipes etc. complete all as specified and directed.
20Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in hard/ dense soil complete all as specified and directed.
21Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point all as specified and directed.
22M&L High density poly-ethylene pipes (HDPE) 40mm dia of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc
23Supply and fix new GI pipe light grade of size 50mm dia for protection of UG cable on walls/under floors/road crossings/in trenches including taking down old unserviceable GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete.
24Supply and fixing 6 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole and current carrying capacity in the MCB DB complete with connection testing and commissioning, all as specified and as directed.
25Taking down the unserviceable LT cable of any size from trenches/ walls /floor etc complete all as specified and as directed Note :- laying of cable route is same as old cable route
26Supply and lay in trenches, fixed to wall / pole/ tray etc UG cable XLPE insulated armoured heavy duty electric UG cable with aluminum conductor 1100 volts grade of cross sectional area 2 core 10 Sqmm, complete all as specified and as directed.Note : Excavation and earth work will be measured and paid separately
27All as per item no.26 herein before but 3.5 Core 25 Sqmm
28Supply and fix PVC insulated two runs of single core 1.5 sqmm FRLS copper conductor and one run of 1.5 sqmm multistranded copper conductor as earth continuity conductor drawn through and including 25mm dia non metallic rigid PVC conduit and accessories complete all as specified and as directed.Note : (i)Two runs of 1.5 Sqmm of single core cable, one run of 1.5 sqmm earth conductor and PVC conduit will be measured as one RM.
29Supply and fix PVC insulated two runs of single core 2.5 sqmm FRLS copper conductor and one run of 1.5 sqmm multistranded copper conductor as earth continuity conductor drawn through and including 25mm dia non metallic rigid PVC conduit and accessories complete all as specified and as directed.Note : (i)Two runs of 2.5Sqmm of single core, one run of 2.5 sqmm earth conductor and PVC conduit will be measured as one RM.
30Supply, erecting and fixing in repair steel tubular swaged poles of type 410-SP-31 (9.0 mtr long) in a proper position complete with CI base plate, finial taper plug, bolts, nuts ,screws and pole cap and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed. Note:- Earth work shall be measured and paid seperately under the respective item.
31Material and labour for preparation of old surfaces of steel pole by scrapping rusted portion of steel electric pole of 9 meter long including metal portion of light fitting and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
32Supply and fixing in repairs Analog weekly time switches for street light timer panel, all as specified and as directed.Make:Legrand Cat No.MicroRex W31 (No. 412814 ) or equivalent in L&T/Havells.
33Minor Repairs and Maintenance of High Mast pole / light including greasing of chain pully, repair to rope, mototr,MCB all as specified and as directed by Engr in charge
34Supply and replacement of feeder pillar box with 200 amp bus bar having 63 Amp MCCB as incomer fixed with angle iron of size 45mmx45mm and 45 cm above ground level with PCC 1:3:6 all as specified and directed
35M & L switching ON and OFF the street lights based on astro time controlling switch for automatic controller of street light on 2.0 mm thick sheet metal enclosure consist of 230 Volt astro Time Switch, MCB TPN 32 Amp. 440 volt contactor 25 Amp, selector switch for auto and manual and internally pre wired, terminal blocks mounting brackets, cable glands and openable door with lock and key and manual setting features complete all as specefied and directed. Make: Indo asian TL032AS0 or its equivalent in L&T/Legrand.
36Taking down old unserviceable copper/aluminium point wiring (light,fan, socket or power) including old unserviceable fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc.
37Taking down carefully old unserviceable submain wiring with aluminum conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc.
38M & L Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core FRLS drawn into and including non-metallic rigid PVC conduit of 20 mm dia,concealed FRLS wiring, along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof excluding Modular Metal flush box and white cover plate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture etc witch shall be measured and paid separately all as specified and directed for One light point controlled by one switch
39All as per item no. 38 herein before but One Ceiling fan/Exhaust fan point controlled by one regulator / switch.
40All as per item no 38 herein before but One 3 pin socket outlet 5 amps socket on independent board.
41All as per item no 38 herein before but One 3 pin socket outlet 5 amps socket on Same Board.
42All as per item no 38 herein before but One light point controlled by two Nos of two way switches.
43All as per item no 38 herein before butOne bell/buzzer point controlled by one push button.
44All as per item No. 38 here-in-before but 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor.
45S&F Modular Socket outlet 2 in 1, 3 pin, 6A 2 Module complete all as specified and as directed.
46Supply and fix Modular switch flush type single pole one way 6 A 240 Volts complete all as specified and as directed including taking down old unserviceable switches.
47Supply and fix Modular switch flush type single pole two way 6 A 240 Volts complete all as specified and as directed including taking down old unserviceable switches.
48Supply and fix switch Socket combination 2 in 1, 6 Amps Flush type 3 module 240 Volts complete all as specified and as directed.
49Supply and fix switch Socket combination 5 Amps / 16 amps, 5 in 1 flush type 3 Module 240 Volts complete all as specified and as directed.
50Supply and fix ceiling rose 3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed.
51Supply and fix call bell Ding dong type.
52Supply and fix Step type electronic Modular fan regulator flush type, 2 Module complete all as specified and as directed.
53S & F modular white cover plate with frame 3 module
54S & F modular white cover plate with frame 6 module
55S & F modular white cover plate with frame 8 module
56S&F of Modular Metal flush box 3 Module
57S&F of Modular Metal flush box 6/8 Module
58Supply and fix Lamp holder PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
59Supply and fixing LED light fitting 1x18 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
60S & F LED light fitting 4feet,1x20w,a trendy wall mounted battern,with extrended aluminium housing,with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
61S&F Energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser,Cat Part No SIRIUS/10W. Make C&S/ Cromption/Havells/philips.
62Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.Make C&S Electric Or Crompton Cat Part N0:TTB2F10WLED/W
63Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
64Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
65Supply Only LED 7/9 watt bulb complete all as specified and directed.
66Supply and fix Bldg security light of capacity 30 watt fixed in existing bracket complete all as specified and directed.
67Supply only LED DRIVER 35/40 watt suitable for 2' x 2' Recess type fittings complete all as specified and directed.
68M&L for sub main wiring/power wiring with 2 runs of 4 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 4sqmm copper FRLS cable as earth lead in PVC conduit all as specified. Note: 3 runs of cable, 1 run of conduit will be measured as unit length for payment.
69M&L for sub main wiring with 2 runs of 6 sqmm PVC insulated stranded copper conducotr FRLS cable and one run of 6 sqmm copper FRLS cable as earth lead in suitable PVC conduit all as specified.Note: 3 runs of cable, 1 run of conduit will be measured as unit length for payment.
70M&L for sub main wiring with 2 runs of 10 sqmm PVC insulated stranded copper conducotr FRLS cable and one run of 10 sqmm copper FRLS cable as earth lead in suitable PVC conduit all as specified. Note: 3 runs of cable, 1 run of conduit will be measured as unit length for payment.
71Supply and fix Sheet metal enclouser with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable Sheet metal enclosure with socket plug top complete all as specified and directed.
72S&F Double Door Vertical TPN Distribution Box 6 way complete in SS enclosure with 200 amps rated busbar.
73Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks •,Circuit Identification Label •,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar complete all as specified and as directed.
74S&F MCB DB SPN 8 way complete in SS enclosure double door type with 200 amps rated busbar.
75S&F MCB DB SPN 12 way complete in SS enclosure double door type with 200 amps rated busbar.
76Supply and fixing SPN 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning
77All as per item no. 76 herein before but SPN 40 to 63 AMP
78S & F RCBO DP,100mA, 240 volts 63 Amps with Front face indication for earth leakage fault IP 20 protected terminals 35 sq mm terminals Sliding shutters. Complete all as specified and as directed by Engr-in-charge.Make:- Legrand Cat Part No 4113 35. or equivalent in Havells/L&T/C&S.
79Supply and fix Isolator TPN 40 Amp complete all as specified and as directed.
80Supply and fix Isolator TPN 63 Amp complete all as specified and as directed.
81Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed.Note :- Replacement of spares will be measured and paid separately under respective items of the schedule here-in-after as supply only.
82Supply only new heating element of capacity 1.5KW/2KW with rubber gasket complete all as specified and directed.
83Supply only thermostat suitable for storage type water heater complete all as specified and directed.
84Supply only Air release valve 15mm dia suitable for geyser complete all as specified and directed.
85Supply only Non return valve 15mm dia suitable for geyser complete all as specified and directed.
86Supply only Apparatus plate assembly suitable to fix thermostate, heating elements as of geyser and nuts etc complete all as specified and directed.
87Taking down defective unserviceable meter and Supply and fix electronic meters tamper proof LCD display with polycarbonate cover 230 V, 10-60Amp, single phase accuracy class-I 50Hz, conforming to IS13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH. Note old defective meter will be deposited in MES store
88Taking down defective unserviceable meter and Supply and fix electronic meters temper proof LCD display with polycarbonate cover 415 V, 10-60Amp, three phase accuracy class-I 50Hz, conforming to IS13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH. Note old defective meter will be deposited in MES store.
89Taking down carefully unserviceable Ceiling Fan of any size from its position, dismantling blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle etc. reassembling after replacement of defective parts including replacement of 3 core 0.75 Sqmm flexible copper cable from ceiling rose to connector, hanging in its position properly complete all as specified and directed. Note:- Replacement of unserviceable spare parts shall be measured and paid separately under respective items of this schedule here-in-after as supply only.
90All as per item No 89 herein before but for exhaust fan of any size
91Supply only ball bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan, pedestal fan as that of existing defective one complete all as specified and directed.(Make : Tata/SKF)
92Supply only bush bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan and pedestal fan of complete all as specified and directed.
93Supply only condenser 2.5 MFD complete all as specified and directed.(Make : Usha/Keltran/uptran)
94Supply only condenser 4 MFD complete all as specified and directed.(Make : usha/Keltran/uptran)
95Material and labour for cleaning and preparing the surfaces of ceiling fan, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed.
96Material and labour for cleaning and preparing the surfaces of exhaust fan removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed.
97Rewinding the stator complete with super enamelled bare copper conductor with the existing size/gauge and number of turns as that of the old one, insulating, varnishing and pre heating for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
98All as per item no. 97 here in before but Exhaust fan upto 300mm sweep.
99All as per item no 97 here in before but Exhaust fan above 300mm upto 450mm sweep.
100Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size upto 300mm sweep complete all as specified and directed.
101Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size above 300mm and upto 450mm complete all as specified and directed.
102Removing the damaged and corroded exhaust fan blades and replace with new blades of size up to 300mm sweep complete all as specified and directed.
103Removing the damaged and corroded exhaust fan blades and replace with new blades of size above 300mm and up to 450mm complete all as specified and directed.
104Supply only 3 core 2.5 Sqmm copper conductor cable suitable for geysers of any size complete all as specified and directed.
105Comprehensive maintenance to Fire alarm and fire fighting system installed in COMCEN and , INS Adyar buildings by deploying suitable Technicians per visit. Team will clean, inspect,&check the functionality of detectors, hooters, Manual call point, Fire control panel, connected wires, pipe lines, hose, motors, startors,fault isolators,batteries, hooter etc. and carryout physical check by testing once in a month on a convenient day at the discretion of User in their presence and a report to this extent will be submitted by the contractor in letter pad complete all as directed by Engineer-in-Charge.
106Comprehensive maintenance to Fire alarm and fire fighting system installed in ,NOM building by deploying suitable Technicians per visit. Team will clean, inspect,&check the functionality of detectors, hooters, Manual call point, Fire control panel, connected wires, pipe lines, hose, motors, startors,fault isolators,batteries, hooter etc. and carryout physical check by testing once in a month on a convenient day at the discretion of User in their presence and a report to this extent will be submitted by the contractor in letter pad complete all as directed by Engineer-in-Charge.
107Comprehensive maintenance to Fire alarm and fire fighting system installed in Navy Nagar buildings(P-22,P-23&P-32) by deploying suitable Technicians per visit. Team will clean, inspect,&check the functionality of detectors, hooters, Manual call point, Fire control panel, connected wires, pipe lines, hose, motors, startors,fault isolators,batteries, hooter etc. and carryout physical check by testing once in a month on a convenient day at the discretion of User in their presence and a report to this extent will be submitted by the contractor in letter pad complete all as directed by Engineer-in-Charge.
108Note for Item No 105 to 107 :- (i) The contractor shall submit a maintenance schedule for the entire period of Contract. (ii) Separate skilled man power (Technician) and non-skilled manpower (Helpers) shall be employed. The team will visit the INS Adyar premises once in a month as and when required in case of emergency (Assumed 01 Emergency vist per month). Report of testing on printed in prescribed formet with in letter pad of the firm shall be submitted. (iii) The above offer will cover round the clock (24 x 7) complaint booking on firm/contractor given Telephone Nos complaints will be attended on the same day. In case the contractor fails to do so, a penalty of Rs. 1000/- per complaint per day for the delayed period will be deducted from payment. (iv) Any breakdown (major or Minor) shall be attended even after working hours and keep the fire alarm and fire fighting system in working condition. Minor spares using up to Rs 1000/ required shall be provided by the contractor to make the system functional for which cost deemed to be included in the rate quoted . The replacement of major parts shall be measured and paid under relevant following items as follows given below :- (v) Contractor is required to quote unit rate for the items 108 and 112 . Fixing charges are included in comprehensive maint . These items will be operated as and when required on order by Engineer-in-Charge. The dept reserves rights to operate these items to the extent it is required at site or not . The contractor shall take this aspect into account while quoting the rates. (vi) Make and specification of items will be similar or superior to the make/description of existing items all as directed by Engr-in-Charge. (vii) Firm should have MOU with Honey well/Appolo before quoting of tender and submit copy of MOU document with honeywell /appolobefrore commencement of work.
109Supply only 1.5 sqmm 2 core PVC insulated sheathed ISI marked FRLS copper conductor multi stranded 1100 volt grade cable drawn through existing conduit connecting and testing all as specified and directed.
110S & F in repairs fire alarm control panel with battery backup for 8 hours normal operation and 15 minutes alarm operation with battery charger . The control panel shall be provided with not redundant CPU (degraded mode is not acceptable), Capacity of panel-01 loop consisting with 640 characters LCD display and for existing net working with software for programming including maintenance free batteries complete all as specified and as directed.
111S & F in repairs detectors complying with and type certified to EN-45 analog type multi sensor detector with heat and smoke combination installation, testing and commissioning complete all as specified and as directed.
112S & F in repairs Manual call point resettable type incl testing and commissioning complete all as specified and as directed.
113Supply only analogue addressable fault isolator modules as per existing make capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected complete all as specified and directed.
114S & F in repairs loop sounder with suitable LED indication hooter type suitable complete all as specified and directed.
115M&L for Remote response indicator for all detectors located above false ceilings suitable to accommodate on ceiling and connecting to smoke/heat detectors all as specified and directed.
116M&L for preparation of new steel and iron surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-charge
117Opening up centrifugal motor cum pump set of 15 HP/11KW capacity for repairs / servicing, replacing all wornout part like bearings, coupling rubber, nut,bolt, washer etc., reassembling, scrapping the rusted surface and painting and making necessary electrical connections & checking the alignment, testing on load to make it functional all as directed.
118Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly vertically to a depth of not less than 2.25m deep below ground level in gorund with the top edge of earth plate at a depth of not less than 1.5m below ground connected to GI earth strip 25 X 4 mm dia galvanised by means of bolts, nuts, washers of galvanised iron or steel, GI earth wre shall be protected by 15mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point complete including testing on completion all as speciifed and as directed. NOTE:- Earth wire beyond 7.5metre shall be measured and paid separately under respective item of this Schedule.
119M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces with cement plaster 1:3 all as specified and directed.
120S&F in replacement MS ERW pipe of size 150 mm bore, including cutting welding, grinding etc all as required at site, laid in trenches complete all as specified and directed.
121All as per item No. 119 herein before but size 80 mm bore
122M & L for single outlet SS hydrant valve with 80mm inlet and 63mm outlet heavy duty fitted with instantaneous female SS coupling cap and chain fixed by means of flange, nuts, Bolts and gaskets complete all as specified and directed.
123S&F in repairs Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm and door with 4 mm thick glass and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete.
124S & F hose reel drum made of high quality mild steel powder coated in red colour confirming to IS - 884 latest revision and ISI marked complete with hose reel nozzle made of metal confirming to IS-8090 latest revision and thermoplastic hose reel tubing, 20mm dia and 30mtr long complete including required length of connecting pipe 25mm dia and on-off ball valve complete all as specified and directed
125S&F in repairs pressure gauge 4\\" dial 0-14 kgs rating type complete all as specified and directed.
126S&F in repairs air release valve 25 mm dia complete all as speicifed and directed.
127S&F in repairs branch pipe Stainless Steel S 63 mm instantaneous inlet, made threaded outlet, 15 mm bore nozzle long complete all as specified and directed
128S&F in repairs 63 mm dia 30 mtr long RRL hose complete with male and female Coupling made out of stainless steel complete all as specified and directed
129Repairs to Fire hose box by jointing of hanging iron doors, replacement of hinges, replacement of door locks etc(Note : Rate deemed to be included for welding machine and other accessories etc required for repairs at site)
130S&F CI foot Valve 150 mm for pump set
131S& F of MS flange size 80/100/150 mm welded or threaded as per site
132S&F brass nozzle of size 20mm for hose reel drum
133M&L MS Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed.
134M&L for Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt (weight per sqm not exceeding 4 Kg)
135M&L for periodical cleaning of UG sump of Capacity 25000 Gallons (Fire static tank OF NOM ) by scrubbing, brushing the edge on all sides, floors, ceilings by with suitable germ killer conforming to IS 1065 of 1969 including pumping / bailing out the dirty water, mud, silt, slush and any other sediments washing thoroughly with fresh water and applying a coat of white wash on internal surface of wall, roof and floor of sump and two coat of colour wash for exposed outer surface all as directed.
136Supply and fixing in replacement First Aid box PVC body with complete kit/accessories wall mounting type all as specified and directed.
137S&F Sheet glass 4.0mm thick ordinary quality and glazing with oil putty or clip in squares not exc 0.5 sqm in each pane all as specified and directed.
138S&F Fire precaution chart fixed NOM, COMSEN, Adyar Adm Building, HQ TN&P, NCN all as specified and directed.
139Repair and maintenance of Fire fighting pipe line by gas welding including repairs to arrest leakage at various bldg all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57010951
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Street Light, Security Lights Including Bollard Lights At Zone A And Repair/Replacement Of Internal Electrification Including Db,Mcbs,Lights,Ceiling Fans,Exhaust Fans And Geysters At Zone A And Comprehensive Maintenance Of Fire Fighting Alarm System At Various Location Under Ge(Navy) Chennai
Basic Detail
Tender No 8830/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 14 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 47 Lakhs
Tender Fee 500
EMD 94000
Exemption Available
Document List
5581d527-6eaf-4f4d-b351-4b92046e721a.html
8830GENERALPAGES.pdf
8830PS.pdf
BOQ_879016.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

5581d527-6eaf-4f4d-b351-4b92046e721a.html

pdf

8830GENERALPAGES.pdf

pdf

8830PS.pdf

xls

BOQ_879016.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders