Tender For Elv Work For Setting Up Lan Connectivity Along With Allied Iei Work For Providing Power Supply For Existing Computer Systems.
Tender Value
40.69 Lakhs
Estimated cost
Bid Submission
21 Aug 2026
6 days left
EMD
81388
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Elv Work For Setting Up Lan Connectivity Along With Allied Iei Work For Providing Power Supply For Existing Computer Systems.
BOQ
| Sl. No. | Item Description |
| 1 | Sub Head-I: LAN/ELV WORKSupply, Installation, Testing & Commissioning of 2 Port Style (Square) (86 x 86mm) x 12 mm Shutter on Face Plate Two Piece design : Mounting Frame and Cover Plate Should support UTP and STP Jacks Cat6. Material: UL 94V-O rated, ETL Verified 4 connector channel performance with MTPL up to 635 MHz, Complaint to RoHS Directive 2011/65/EU and (EU) 2015/863 (for user side). |
| 2 | Supplying and fixing following size/ modules, GI box along without modular base & cover plate for modular switches in recess etc. as required.A) 1 or 2 Module (75mmX75mm) |
| 3 | Supplying, Installation, Testing and commissioning of following CAT-6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required at site.A) Copper Patch Cords of length 3m (10 ft.) |
| 4 | Supplying, Drawing, Installation, Testing and Commissioning of CAT6 UTP LSZH 23 AWG Twisted Pair Cable in existing conduit/on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1 mm nominal with Operating Temperature Range: -5°C to +60°C, Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5 Kg etc. complete as required at site.A) 1 Run of Cable |
| 5 | 2 Run of Cable |
| 6 | 3 Run of Cable |
| 7 | 4 Run of Cable |
| 8 | Supply, Installation, Testing & Commissioning of Category 6A, RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568.2-D Categiry 6A, IEC 60603- 7-41, Plug Reliability : 750 Cycles minimum, PCB Material FR-4, Keystone design. Tolless type, 50 Micron Gold Plating Suitable For 23~24 AWG Stranded and Solid Wire. Compliant to T568A and T568B Wiring Schemes. ETL Verified 4 connector channel performance with MTPL up to 635 MHz, Complaint to RoHS Directive 2011/65/EU and (EU) 2015/863. OEM should have ISO 9001:2015, ISO 14001:2015, ISO 45001:2018 and should be present in India for at-least 10 years or more for Data, Voice 7 Wifi at User End. |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required at site.(A) 25 mm |
| 10 | 40 mm |
| 11 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8 mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U' Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5 mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required at site.A) 6U Rack |
| 12 | 15U Rack |
| 13 | Supplying, Installation, Testing and Commissioning of 24 port Cat-6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required at site. |
| 14 | Supply and fixing of following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900 μm tight buffered fiber storing, Capable of storing up to 3 meters of 900 μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc. complete as required at site.A) 24 Port LIU |
| 15 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3 Network Switch having features and specifications etc. as mentioned here under: At least 20 X RJ-45 Gigabit Ethernet Ports and additional 4 combo 10/100/1000 base-t/SFP Ports with additional 4 SFP+ ports non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Internal AC Power supply with operating temperature of 0 to +50 0C. Stacking port with stacking support of minimum 8 units per stack. 32K Mac address, 9K or more Jumbo frame, ERPS with enabling ring to converge in less than 50 ms from node or link failure, Static routing, Static, 6to4, ISATAP and GRE, .IPv6 Neighbour Discovery (ND), BGP/ISIS/ MPLS/VRRP v2/OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should support from day 1 for both IPv6 and IPv4, 802.1x, Port security , Radius C TACACS+ authentication C accounting, DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP Access List, MAC Access List. Multicast: VLAN, PIM-SM, PIMDM, PIM- SDM, PIM-SMv6, DVMRP v3 and MSDP, IGMP C MLD Snooping, Flow mirroring, IGMP C MLD Snooping Ǫuerier, Per-VLAN IGMP C MLD Snooping. SNMP, Dual configurations, Multiple images, RMON, LLDP/LLDP-MED, sFlow, DHCP/BOOTP Client, IPv4/IPv6, Syslog server, Debug command, 802.3ah Ethernet Link OAM, 802.1ag Connectivity Fault, Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control (PFC), Dying Gasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: FCC, CE marked, UL/EN,RoHS and relevant MTCTE(TEC)/BIS compliance/certification as applicable, etc. complete as requiredd. |
| 16 | Supplying, installation, Testing and commissioning of 48 Port Access SW shall be 1RU, 19\\"\\" Rack Mountable fully managed switch,48x 1G and 4x 1/10 fiber uplink ports,1 RJ-45 (serial RS-232C) or USB console port, 2 GB MB flash, 2 GB DRAM,Packet Buffer 5 MB, Shall have switching capacity of 176 Gbps for providing non-blocking performance on all Gigabit ports and min 130 Mpps of forwarding capacity, should support stacking or equivalent via dedicated stacking/uplink ports, Should support for minimum 50 Gbps of stacking throughput with minimum 8 switch in stack. All the required cables/accessories for stacking should be provisioned from Day 1, IEEE 802.1D STP, IEEE 802.1w RSTP and IEEE 802.1s MSTP, 802.1x, 802.1ae, 802.3x, 802.1p, 802.1Q,IEEE 802.3ad Link Aggregation Control Protocol (LACP) up to eight links (ports) per group, MAC address table size of 16K entries and 256 Active VLANs, Shall support 1K ACLs, 1K Multicast Routes and 2K IPv4/IPv6 Routes, Shall support Jumbo frames to improve the performance of large data transfers, Internet Group Management Protocol (IGMP), IEEE 802.1AB Link Layer Discovery Protocol (LLDP), Multicast Listener Discovery (MLD) snooping and PIM from day 1, Should support OSPF, Policy-Based Routing and VRRP from Day 1,IPv6 host and Dual stack (IPv4/1Pv6) support to provide transition mechanism from IPv4 to IPv6, Traffic prioritization based on IP address, IP Type of Service (ToS), Layer 3 protocol, TCP/UDP port number, source port, and DiffServ. Should support strict priority queuing, Access Control Lists (ACL) for traffic filtering and Dynamic VLAN assignment, Should support MACSEC as per IEEE 802.1AE on hardware from day 1, Should support port security, DHCP snooping, Spanning tree root guard, First Hop Security or equivalent, Switch should capable to understand that system OS are authentic and unmodified, it should have cryptographically signed images to provide assurance that the firmware & BIOS are authentic, Configuration through the CLI, console, Telnet/SSH and browser-based management GUI, SNMPv1, v2, and v3 and Remote monitoring, (RMON) support, sFlow/netFlow or equivalent for traffic analysis TFTP and Secure FTP support, RADIUS/TACACS+ for switch security access administration, Network Time Protocol (NTP) or Precision Time Protocol (PTP), Should support comprehensive programmability features like Model- Driven Programmability, NETCONF/REST interface, API or equivalent, 2 field-replaceable and hot-swappable power supplies from day 1, Operating temperature of 0°C to 45°C, Switch shall conform to UL/IEC/EN 60950-1 or latest UL/IEC/EN 62368-1 Standards, Switch / Switch’s Operating System should be tested for EAL2/NDPP/NDcPP or above under Common Criteria Certification. (Make: Cisco/Arista/Juniper) |
| 17 | Supplying and drawing of following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 μm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, <1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5°C to +50°C and Storage Temperature should be – 5°C to +50°C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed, Cladding Diameter 50 ± 2.5 μm and 125 ± 1μm correspondingly i/c splicing & marking etc. complete as required at site.A) 6 Core Multi Mode Optical Fiber Cable |
| 18 | Supplying, Installation, Testing and Commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required at site.A) 10 G SFP + (Multi Mode) |
| 19 | Supplying and Fixing of Patch Cord of Optical Fiber Multi Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2 mm with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5°C to +50°C, Storage Temperature – 10°C to +50°C, Length - 2meter, Type - LC-LC Duplex etc. complete as required at site. |
| 20 | Supply, Installation, Testing, and Commissioning of heavy-duty Surface/Wall Mountable Power Distribution Unit (PDU) rated for 230V AC, 16A operation, housed in a rugged, fire-retardant, high-impact ABS or Aluminum enclosure suitable for standalone or under-desk applications; the unit shall be configured with [4/6/8] Nos. of 5/15A Universal/Indian round-pin sockets with safety shutters and high-conductivity internal copper busbars; specifications must include an integrated illuminated Master Switch with thermal overload protection/fuse and built-in Surge Protection Device (SPD) to protect connected sensitive electronics from voltage spikes; the scope includes the supply of a minimum 3-meter long heavy-duty 3-core power cord with a molded 3-pin plug top, secure fixing of the unit onto the wall, furniture, or skirting using appropriate screws/fasteners through provided keyholes or mounting brackets, and neat routing of cables to the power source, complete in all respects as per site requirements and the direction of the Engineer-in-Charge. |
| 21 | Sub Head-II: IEI WORKSupplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required at site.A) 6 Module (200mmX75mm) |
| 22 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required at site.A) 6 Module |
| 23 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required at site.A) 15/16 A switch |
| 24 | 6 pin 15/16 A socket outlet |
| 25 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required at site.A) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 26 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required at site.A) Single pole Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysAug 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer