Tender For Renovation Of Dm Office Kanjhawala, Sub Divisional Magistrate Office (Nangloi, Kirari) And Sub-Registrar Office, Nangloi Including Supply Installation Testing and Commissioning of Led Luminaires, Pc System, Fans, Stac Under North West Dist
Tender Overview
Project Description
Tender for Renovation Of Dm Office Kanjhawala, Sub Divisional Magistrate Office (Nangloi, Kirari) And Sub-Registrar Office, Nangloi Including Supply Installation Testing and Commissioning of Led Luminaires, Pc System, Fans, Stac Under North West District, Kanjhawala Delhi
BOQ
| Sl. No. | Item Description |
| 1 | SH-I EI workWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group C |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.a) Group C |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 x 1.5 sq. mm |
| 4 | b) 6 x 1.5 sq. mm |
| 5 | c) 3 x 4 sq. mm |
| 6 | d) 6 x 4 sq. mm |
| 7 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (For SDM Nangloi)a) 20 mm |
| 8 | b)25 mm |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 A switch |
| 10 | b) 3 pin 5/6 A socket outlet |
| 11 | c) 15/16 A switch (4 in each Room) |
| 12 | d) 6 pin 15/16 A socket outlet |
| 13 | e) Blanking Plate |
| 14 | f) Bell push |
| 15 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required |
| 16 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing andn fixing 25 A modular socket outlet and 25 A modular SP MCB,“C” curve including connections, painting etc. as required. |
| 17 | Supplying and fixing 16 Amp, 3 pin plug top made of high quality unbreakable polycarbonate body, suitable for 230V AC single phase supply, complete as required. |
| 18 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (For Wall Fan in Corridor) |
| 19 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 20 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. a) 3 Module (100mmX75mm) |
| 21 | b) 6 Module (200mmX75mm) |
| 22 | c) 8 Module (125mmX125mm) |
| 23 | d) 12 Module (200mmX150mm) |
| 24 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. a) 3 Module |
| 25 | b) 6 Module |
| 26 | c) 12 Module |
| 27 | SH :-II Fans, Light Fittings and DispenserSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 28 | SITC of 400 mm sweep oscillating type wall fan complete with all accessories such as front jaali i/c connection etc. as reqd |
| 29 | Supplying & fixing of 300/305 mm sweep 1300- 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd |
| 30 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)a) 36 watt |
| 31 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)a) 18- 22 watt |
| 32 | Supplying, Installation, Testing & Commissioning of LED Mirror Light fitting of 10 Watt, 600 mm long, aesthetically designed with powder coated / chrome finish housing and opal diffuser, suitable for wall mounting over mirror, complete with inbuilt LED driver, operating on 230V AC supply, having low power consumption, glare free illumination and complete with all mounting accessories, connections, testing and commissioning etc. as required and as directed by Engineer-in-Charge. |
| 33 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.a) 12 -15 watt |
| 34 | Supplying, Installation, Testing & Commissioning of Decorative LED Post Top Lantern fitting suitable for outdoor lighting application, pressure die-cast aluminium housing with UV stabilized polycarbonate diffuser, having IP-65 protection, impact and corrosion resistant construction, glare-free optical system with better illumination uniformity, complete with high efficiency LED driver, power factor not less than 0.95, THD less than 10%, suitable for operation on 140-270V AC supply, mounted on existing/new pole with all required accessories, nuts, bolts, clamps, internal wiring etc. complete as required.a) 35 Watt (For SR Nangloi) |
| 35 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beamangle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be ofrelevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 100 watt (For SR Nangloi ) |
| 36 | Supplying and fixing hot press moulded SMC box (sintex) of size 140mm x 140mm x 95mm i/c s/f neutral link sp mcb 0-32 amp on the existing pole /on the wall surface or recess repairing etc as reqd. ( For SR Nangloi) |
| 37 | SH :-III MCB, DB, Cabling and Panel WorkSupplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole |
| 38 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 4 way (4 + 12), Double door |
| 39 | Providing and fixing following rating and breaking capacity and pole MCCB/TPN/SPN MCB with thermomagnetic release and terminal spreaders & associated switchgears in the above cubical panel board/TPDB including drilling holes in cubicle panel, fitting strips for MCB ,making connections, etc. as required.a) 100 A, 10 KA , TPN MCB (C-Curve) (for replacing i/c in existing 3 Phase DB 4 Nos SDM Nangloi, 4 Nos SR Nangloi, 1 NewAC DB in SR Nangloi) |
| 40 | b) 63 A, 10 KA. DP MCB (for Replacingi/c in Existing 1-phase DB 8 Nos SDM Nangloi and 8 Nos SR Nangloi) |
| 41 | c) 400 A,50KA,FPMCCB (For SR Nangloi changing Compound MCCb) |
| 42 | Providing and fixing sheet steel enclosure suitable for 400 Amp FP/TPN MCCB, fabricated out of CRCA MS sheet, dust and vermin proof, wall mounted type, having hinged door with locking arrangement, powder coated finish after proper surface treatment, , earthing terminals and complete with all hardware, nuts, bolts, connections, testing and commissioning etc. as required and as directed by Engineer-in-Charge. (For SR Nangloi 400 A Enclosure) |
| 43 | Fabrication, Supplying, Installation, Testing & Commissioning of floor mounted cubical type LT Distribution Panel made out of 2 mm thick CRCA MS sheet, dust & vermin proof, compartmentalized, free standing, front operated, having suitable angle iron/MS channel base frame, detachable gland plates, complete with powder coating after proper surface treatment, aluminium busbars of 600A capacity with colour coded heat shrinkable sleeves, earthing terminals, interconnections, danger notice plate, hardware etc. complete as required, comprising of following switchgears and accessories:1 No. 400 Amp TPN MCCB incomer, 50 kA breaking capacity adjustable thermal magnetic release.4 Nos. 100 Amp, 16 KA TP MCCB outgoing feeders.(For TPN DB)12 Nos. 63 Amp DP MCB/MCCB outgoing feeders. (8 Nos for SPN DB and 4 Nos Flood Light)5 Nos. 63 Amp TPN MCCB outgoing feeders.( For Motor and Miscellaneous)1 Nos Ammeter with selector switch.1 Nos Voltmeter with selector switch.1 Set RYB indicating lamps complete with control fuses/MCBs.Suitable current transformers (CTs) for metering complete with wiring.The panel shall be suitable for 415 Volts, 3 phase, 4 wire, 50 Hz AC supply complete in all respect as per specifications and direction of Engineer-in-Charge. (For SDM Nangloi) |
| 44 | SITC of 3 HP Monobloc booster pumpset having a discharge range of (250-110) LPM ± 10 % tolerance for head range of (24-36) Metre ± 10% tolerance suitable for operation on 3 phase, 340 50Hz AC supply i/c flange cable joint, gasket, nut & bolts etc as required. (For SR nangloi) |
| 45 | SITC of double compartment DOL Starter Panel suitable for operation upto 2 Nos. 7.5 HP three phase motors complete with 63A TPN as incomer, 3 Pole contactors, Over Load Relay, single phase preventers, Ameter and Voltmeter with Selector Switches, RYB indication lamps, push buttons with Auto/ Manual Selector Switches, internal wiring etc. (for SR Nangloi) |
| 46 | SH :- IV Fire safety and Rolling Shutter RepairSupplying & fixing of following accessories of fire fighting safety system i/c testing & commissioning etc complete as required. a) Fire Bucket 24 gauge 9 ltr. Capacity (4- SDM Nangloi and 4- SR Nangloi) |
| 47 | Fire bucket stand without bucket for fixing 4 bucket (Angle Type) (1- SDM Nangloi and 1- SR Nangloi) |
| 48 | Supplying, Installation, Testing & Commissioning of Energy saving & environment friendly Laser Etched pendent type LED exit signage board bi-lingual super bright red/green LED's with Sign like hydrant, lift etc. Made of MS housing Powder Coated having acrylic sheet etched with super bright LED, power consumption less than < 2 watt, battery 7.4 volt lithium Ion 2200 mah with back up of 8 hoursrecharge period of 12 hours operating voltage of 190 to 230V etc. complete required. a) Single Side (Size of one Signage 14*6.4 inch, Total-5 Nos) |
| 49 | b) Double Side (Size of one Signage 14*6.4 inch, Total-5 Nos) |
| 50 | Supply, Installation, Testing and Commissioning of electronic insect flasher (insect killer) suitable for indoor use, comprising UV-A lamps for attraction of flying insects, high-voltage grid for instant elimination, complete with removable collection tray, protective outer housing made of corrosion-resistant material, and safety mesh to prevent accidental contact. The unit shall be wall/ceiling mountable, energy efficient, noiseless in operation, and suitable for operation on 230V, 50Hz AC supply. The equipment shall conform to relevant safety standards and be provided with all necessary accessories, wiring, fixing arrangements, and earthing, complete as required. (1-SDM(K),1-SDM(N),T(K),T(N),SR(N),BDO) |
| 51 | Refilling of 6 Kg capacity ABC type fire extinguisher cylinder including opening of cylinder, removal of old extinguishing media, checking of internal condition, refilling with fresh MAP based ABC dry chemical powder of required capacity, replacement of defective ‘O’ rings, washers, hose pipe, nozzle and other minor accessories if required, repressurizing with dry nitrogen gas, leakage testing, safety checking, repainting, fixing of service tag/sticker and complete testing as per IS specifications complete in all respect as required and as directed by Engineer-in-Charge. (For SR nangloi and SDM nangloi). |
| 52 | Refilling of 4.5 Kg capacity CO₂ type fire extinguisher cylinder including dismantling of cylinder, removal of residual gas, internal inspection, hydraulic/pressure testing wherever required, refilling with fresh carbon dioxide (CO₂) gas of approved quality and required weight, replacement of defective washers, valve components, discharge horn, hose pipe and other minor accessories if required, leakage testing, repainting, fixing of service tag/sticker and complete testing as per IS specifications complete in all respect as required and as directed by Engineer-in-Charge.(For SR nangloi and SDM nangloi). |
| 53 | Repairing and servicing of existing rolling shutter of suitable size including replacement/repair of damaged guide channels, brackets, springs, ball bearings, locking arrangement, welding work, alignment of shutter plates, lubrication of moving parts, rectification of smooth operation and painting of shutter with one coat of primer and two coats of synthetic enamel paint of approved shade complete with surface preparation, scraping, cleaning and all necessary T&P, materials complete as required and as directed by Engineer-in-Charge. |
| 54 | SH :- V PC SystemProviding of All-in-one Desktop computer with following configuration as given below: - Processor : - Intel Core i5-1335U (up to 4.6 GHz with Intel Turbo Boost Technology, 12 MB L3 cache, 10 cores, 12 threads) or Higher Processor, Memory: - 16 GB DDR4-3200 MHz RAM (2 x 8 GB), Hard Drive - 1 TB SSD or Higher Specs, Operating System & Software: Pre-loaded Windows 11 Home| Microsoft Office Home & Student Edition 2021, Display - 68.6 cm (27) diagonal, FHD (1920 x 1080), IPS, three-sided micro edge, anti-glare, 300 nits, IPS, three-sided micro edge, along with wireless Key board and Mouse, Lan Adapters USB and HDMI Ports, Graphics Card, Integrated. HD Audio compatible and 1 (one) year warranty with all accessories etc accessories as required. |
| 55 | SH :- VI Cable Laying Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Al armoured power cable of 1.1 KV grade of following size on wall surface/recess as required. a) size 3 X 10 sq. mm on Wall Surface (For Flood Light and Post Top Lamp in SR Nangloi) |
| 56 | b) size 4 X 25 sq. mm in Existing Pipe (For AC DB in SR Nangloi) |
| 57 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade of following size direct in existing GI /HDPE/DWC pipe with complete fitting etc as required. a) size 3 X 10 sq. mm in Existing Pipe (For Flood Light and Post Top Lamp in SR Nangloi) |
| 58 | b) size 4 X 25 sq. mm in Existing Pipe (For AC DB in SR Nangloi) |
| 59 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE al. conductor cable of 1.1 kV grade as reqd. a) 3 X 10 sq. mm (22mm) |
| 60 | b) 4 X 25 sq. mm (28mm) |
| 61 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 62 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 63 | SH :- VII LAN WorkProviding and fixing of PVC Trunking of following sizes complete with flexible cover, joint, endcap, cover on surface of wall/existing mounting etc. as required. (For SR nangloi) a)105 mm x 50 mm |
| 64 | Providing and fixing of DLP Trunking of following sizes complete with flexible cover, joint, endcap, cover & Partition on surface of wall/existing mounting etc. as required. a) 32 mm x 20 mm |
| 65 | b) 105 mm x 50 mm |
| 66 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 67 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 68 | SH :- VIII AC WorkSupply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).a) 1.5 TR with 5 Star BEE Rating |
| 69 | Supplying & Fixing of 4 KVA capacity automatic voltage stablizer with time delay relay and high/low voltage trip facility input voltage 150V to 290V±10% and output voltage 220±10% with copper flexible cable connection etc. as required at site. |
| 70 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as reqd : a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 71 | b) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 72 | Providing, laying, fixing, and commissioning of PVC (Polyvinyl Chloride) drain pipe for Air Conditioning units, including all necessary fittings such as elbows, tees, reducers, clamps, supports, adhesives, and accessories as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender