Tender For Supply, Installation, Testing And Commissioning Of Clean Room Facility Of Class 1000 & Class 10000 For Mc-Icp- Ms Lab At Hall 10, Barc Trombay, Mumbai -85
Tender Value
3.70 Crore
Estimated cost
Bid Submission
15 Sep 2026
30 days left
EMD
7.40 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing And Commissioning Of Clean Room Facility Of Class 1000 & Class 10000 For Mc-Icp- Ms Lab At Hall 10, Barc Trombay, Mumbai -85
BOQ
| Sl. No. | Item Description |
| 1 | Double skin type air handling units suitable for clean room application of following capacity as per TSS 01 a) Capacity : 35 TR, b) Air Flow Rate : 25000 CFM c) St. Pressure : 150 mm of WC |
| 2 | Double skin type fresh air units suitable for clean room application of following capacity as per TSS 02 a) Air Flow Rate : 1500 CFM b) St. Pressure : 125 mm of WC |
| 3 | Vertical inline centrifugal Chilled water Booster pumps with suitable motor capacity as per TSS 03 a) CHW flow: 500 LPM b) Head: 25 m WC c) Media: Chilled water |
| 4 | 1.2 mm thick GI Ducting as per TSS 04. |
| 5 | Manually operated heavy duty opposed blade type multilouvered volume control damper with outer body frame and blades fabricated out of GI as per TSS 05 |
| 6 | Regulating/Modulating type electrically operated heavy duty opposed blade type multilouvered volume control damper with outer body frame and blades fabricated out of GI as per TSS 06 |
| 7 | Solenoid coil based electrically and fusible plug operated heavy duty opposed blade type multilouvered fire damper with outer body frame and blades fabricated out of GI section as per TSS 07 |
| 8 | Nitrile rubber thermal Insulation |
| 9 | Insulation :-25 mm minimum thick nitrile rubber insulation with fiber cloth of approved colour as per TSS 08 |
| 10 | Insulation:-50 mm minimum thick nitrile rubber insulation with fiber cloth of approved colour ( 2 Layer of 25 mm each) as per TSS 08 |
| 11 | DN100, Heavy class GI pipe as per IS 1239 with necessary fitting as per TSS 09 |
| 12 | Valve and strainer with counter flanges and Insulation with fibre cloth as per TSS 10 |
| 13 | DN 100, SS 304 Ball Valve, ASME Class 150 pressure class |
| 14 | DN 25, SS 304 Ball Valve, ASME Class 150 pressure class |
| 15 | DN100 CS ASTM 216 Gr WCB flanged type Y Type strainer of ASME Class 150 |
| 16 | DN 100 flanged type CS Non Return Valve (Swing/dual plate valve) of ASME Class 150 |
| 17 | DN 100 flanged type CS globe valve flanged type of ASME Class 150 |
| 18 | 3 Way control valve of DN 100 of ASME Class 150 with modulating type actuator and temperature controller with PT 100 temperature sensor as TSS 10.6 |
| 19 | Ductless Recirculatory type Fume Hood having MOC GI precoated/ powder coated or such material suitable for class 1000 cleanliness class as per TSS 11 |
| 20 | Vane axial fan for plasma and ozone exhaust with motor having following duty as per TSS 11 |
| 21 | 1) Flow- 75 CFM 2) Static Pressure- 20 mm wg |
| 22 | 1) Flow- 55 CFM 2) Static Pressure- 20 mm wg |
| 23 | Wall Riser Panel- 120 mm thick Clean room compatible return air riser panel with provision of annular space for returning the air by sandwiching Rockwool insulation between outer and inner skin of 0.8 mm thick GI powder coated/precoated sheet and powder coated Return Air Grille with damper as per TSS 12 |
| 24 | Wall Panel -120 mm thick Clean room compatible panel by sandwiching Rockwool insulation between outer and inner skin of 0.8 mm thick GI powder coated/precoated sheet .The panels will have provision of electrical and other services if required as per TSS 12 |
| 25 | False Ceiling Panel and return air Plenum- 50 mm thick Clean room compatible panel by sandwiching PUF insulation between outer and inner skin of 0.8 mm thick GI powder coated/precoated sheet . The panels will have provision for installation of HEPA filter boxes, lighting fixtures and other services. as per TSS 12 |
| 26 | Top Ceiling Panel and return air Plenum- 30 mm thick Clean room compatible panel by sandwiching PUF insulation between outer and inner skin of 0.8 mm thick GI powder coated/precoated sheet as per TSS 12 |
| 27 | T-grid Ceiling System: Design and SITC of Aluminium Extruded T-grid ceiling suspension system suitable for mounting HEPA filter & lighting fixture complete with wall angle, main runner, cross-T, adjustable hanger, studs, seals and other associated fittings and accessories as per TSS 13 |
| 28 | Air Shower: Self contained fully equipped clean air shower suitable for two persons and fabricated out of SS 304 sheet with standard MAT finish. The air shower shall be capable of de-contamination and regulate the entry of persons in the clean room as per TSS 14 |
| 29 | Clean Room Door: Clean room compatible double skin doors of SS Material, single leaf door of size: 1500 (W) x 2100 (H) mm approx. complete with door closer, tower bolt, hinges, frame etc. as per TSS 15 |
| 30 | Clean Room Coving: GI powder coated coving having approx. 65 mm face width complete with 2D & 3D corners joints, sealant, fasteners and fittings for partition & floor and partition & ceiling corner joints of clean room as per TSS 16 |
| 31 | Laminar Air Flow Bench: GI precoated/powder coated horizontal laminar air flow clean bench complete with microprocessor controller, built-in lighting, Fine & HEPA filters etc. Length : 1250 mm (approx.), Width : 1000 mm (approx.), Height : 600 mm (approx.) as per TSS 17 |
| 32 | Seperatorless Minipleat HEPA Filter, H 14 grade having a) Size: 1220 x 610 x 68 mm (approx.) b) Flow : 1200 CMH c) Casing : Box type in SS304 d) Efficiency : 99.997% down to 0.3 micron particle size e) Initial pressure drop - min 11 mm H2O as per TSS 18 |
| 33 | Terminal HEPA filter Box: Terminal HEPA filter box fabricated out of min 16 Gauge thick SS304 sheet complete with in-built SS volume control damper, SS perforated sheet, bevel gear arrangement, DOP injection port, pressure measurement port etc. and suitable for mounting HEPA filters as having Filter box suitable for HEPA filters of approx. size 1220 x 610 mm as per TSS 19 |
| 34 | Refrigeration type Dehumidifier of 35 Liters per day moisture removal capacity as per TSS 20 |
| 35 | Clean Room Epoxy Flooring: Supply of material and applying of 3 mm thick self-levelling Electrostatic Discharge (ESD) epoxy flooring including preparation of surface, primer coat, screeding, levelling coat and finishing coat of approved colour and shade. as per TSS 21 |
| 36 | Clean Room Garments: Providing of ISO-6 clean room compatible garments consisting of coverall, footwear, gloves, face mask etc. of standard size and quality as per Technical Specification Sheet as per TSS 22 |
| 37 | Clean Room cleaning, air balancing, validation, preparation of reports and submission for compliance of cleanliness requirement as per TSS 23 |
| 38 | Dismantling and disposal of existing ducting, insulation dampers , lighting fixture etc as per TSS 24 |
| 39 | Lighting Fixtures |
| 40 | GI ducting ( 100 SQM) along with insulation, cladding, supports, dampers, grilles etc. |
| 41 | Instrumentation as per TSS 25 |
| 42 | Temperature Gauge: 100 mm dia stem type thermometer suitable for measurement of water temperature in the range of 0 to 50 deg C in SS construction complete with SS thermowell, thermic fluid and other accessories as per site requirement. |
| 43 | Pressure Gauge: 100 mm dia bourdon tube type pressure gauge suitable for measurement of water pressure in the range of o to 10 kg/cm2 in SS construction complete with SS syphon, cock and other accessories as per site requirement. |
| 44 | Electronic type humidistat suitable for on-off operation of heaters to control humidity. |
| 45 | DN 100 dia Electromagnetic flow meter for measurement of water flow in 100 mm dia. pipe line having measuring range 0 to 1000 lpm |
| 46 | Wall mounted relative humidity meter (Hygrometer) cum digital temperature indicator. |
| 47 | Differential pressure Transmitter having pressure measuring range of 0 to 15 mm WC |
| 48 | Magnehellic Gauge: 150 mm dia type Magnehellic gauges of following ranges suitable for measurement of differential pressure across the filters and complete with connecting copper/PVC tubing, SS box & other accessories as per site requirement as per TSS 25 |
| 49 | 0 to 15 mm of WC |
| 50 | 0 to 25 mm of WC |
| 51 | 0 to 100 mm of WC |
| 52 | 20 kW Electric heater box made out of SS sheet of appropriate thickness with SS tubular finned heater complete with associated accessories as per TSS 26 |
| 53 | Stainless Steel Work: Fabrication and supply of Change Over Bench, Garment Cubicle, Computer Tables, Platform, Stands, etc. as per site requirement as per TSS 27 |
| 54 | MS Structure Work: Fabrication & supply of M.S structure wherever required. The M.S structure shall be painted with two coats each of red oxide & bituminized paint after properly cleaning the surface as per TSS 28 |
| 55 | Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge |
| 56 | Dismantling doors, windows and clear storey openings (steel/wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100m lead (full windows) Of area 3.00 Sq.M and below |
| 57 | Dismantling doors, windlows and clear storey windows (steel/wood) shutter including chowkhats, architraves, holdfasts etc. complete and stacking within 100m lead (full windows) Of area beyond 3.00 Sq.M |
| 58 | Dismantling Aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplaus material and stacking of serviceable materials within 100 m lead as directed by the Engineer-in-charge |
| 59 | Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (fittings glazing and panelling shall be paid for separately) |
| 60 | Anodised Aluminium sections (Minimum anodizing thickness of 15 micron) |
| 61 | Extra for colour anodizing |
| 62 | Designing, providing and fixing of 4mm thick approved make and shade Aluminium Composite Metal Panel of approved make cladding at different locations including soffits of over-hangs and including aluminium frame work with grids filled in with weather silicon sealant as per the drawings. The ACM panel composition shall be of 0.5mm thick PVDF coated aluminium sheet + 3mm thick low density polyethelene virgin resin core + 0.5 mm thick polyester (PVDF) coated Aluminium sheet all complete as per approved shop drawings and specification. |
| 63 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples,reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydralic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked 'C' -Class heavy quality pipes of approved make. |
| 64 | 15 mm dia G.I pipe |
| 65 | 20 mm dia G.I pipe |
| 66 | 25 mm dia G.I pipe |
| 67 | Providing & fixing in position heavy pattern screw down gun metal gate valve with handles and wheels of approved make including testing for 10Kg/cm2 pressure with clean and potable water with a minimum testing duration of two hours etc.as per specification and as directed by the Engineer-in-charge |
| 68 | 20 mm n.b |
| 69 | 25 mm n.b |
| 70 | Providing and fixing viterious China wash basin of approved make and colour with C.I. brackets, 15 m C.P. brass pillar tap of approved make,15 mm x 600mm long PVC Inlet connection, 32 mm heavy quality C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge |
| 71 | White vitreous China wash basin size 630 x 450 mm and equivalent sizes with single 15 mm C.P. brass pillar tap |
| 72 | Providing and fixing heavy quality CP brass bottle trap 31 / 32 mm of approved make single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal,of approved make for wash basins / urinal etc all as per specifications and directed by the Engineer in charge. |
| 73 | Providing and fixing C.P brass Angle cock of heavy quality of specified /approved make, for wash basin inlet /flush cistern etc. as per specifications and as directed by the Engineer-in-charge. |
| 74 | 15 mm n.b CP brass Angle cock of approved make |
| 75 | Provding and constructing brick work in Cement mortar using standard bricks of approved class/ quality, make or brand in foundation and plinth including curing, raking out joints, simultaneous pointing below plinth level if specified, complete as per drawings, specifications and as directed by the Engineer-in-charge |
| 76 | Brick work in C.M 1:4 using crushed sand. |
| 77 | Providing and applying white cement based wall putty of approved make over concrete or Plastered surface upto 3mm thick to get uniform surface free from undulation including cleaning complete all as directed by the Engineer-in-charge |
| 78 | Providing 12mm thick Internal plastering in cement mortar 1:4 without cement punning (using crushed sand) finished smooth, including sieving of sand to requiredfineness, preparation of the surface, scaffolding, curing all as per specifications, drawings and as directed at site complete. |
| 79 | Providing and Painting two coats of synthetic enamel paint on steel surfaces of approved brand and manufacture to give an even shade over a primer coat.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 80 | Providing, applying wall painting two coats on new work with premium plastic emulsion paint of approved brand to give an even shade with out cement primer. including preparation of the surfaces, scaffolding complete. as per specification and as directed by the Engineer-in-charge. |
| 81 | Providing and painting two (or) more coats with Epoxy paint at all locations prepared and applied as per manufacturer's specifications including a priming coat if specified by the manufacturer, preparation of surface by cleaning with wire brush and rubbing with sand paper to remove dust, dirt etc, after first coat Epoxy based trowelling compound if required, including preparation of the surface by scrapping, applying sand paper, by cleaning with wire brush and rubbing, making free of rust, dirt etc. filling the holes, joints, cracks if any etc. complete. all as per manufacturers technical data and as directed at site to acheive 200 micron film thickness (50 micron primer coat + 150 micron finishing coat). |
| 82 | Providing and fixing of Hollow metal fire rated doors of approved manufacturer as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturertest certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame shall be double rebate profile of size 143 x 57 mm made out of 1.60mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled withself tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening. Door shutters shall be of G.I sheet 18 gauge thick with necessary stiffners. Thickness of the door shutter shall be as per design or minimum 40 mm ). 2 hr fire rated Single leaf door single/ double leaf of specified size (of approved manufacturers having CBRI certificate) |
| 83 | Extra over item no. 52 for providing And fixing SS304 Ball bearing heavy duty butt Hinges of size 100 x75 x 3 mm |
| 84 | Extra over item no. 52 for providing And fixing Door Closer - Std Arm |
| 85 | Extra over item no. 52 for providing And fixing Dead Lock with both side Key Cylinder |
| 86 | Extra over item no. 52 for providing And fixing Stainless Steel SS304 Pull - H- Type handle- 32mm Dia& 600 mm Long |
| 87 | Extra over item no. 52 for providing And fixing Fire rated Clear Glass 6mm thick- 200mmx 300mm forvision pannel. |
| 88 | Extra over item no. 52 for providing And fixing Four point SS panic bar with external Trim. |
| 89 | Providing, supplying and fixing hollow metal flush steel doors 40 mm thick of approved make consisting of door frame and shutters and all hardware fittings, frame made out of 14g thick G.I sheets and shutters made of 16g thick sheets, hollow portion filled with puff, including necessary stiffners in shutters and frame, vision panel of specified size with 4 mm glass and clip on pressed steel frame for vision panels, fixing 4 nos heavy duty stainless steel 304 grade ball bearing hinges, mortise / dead lock of approved make, a pair of 200 mm long stainless steel handles, 250 mm long stailless steel tower bolt, etc. frame hollow portion filled with PCC 1:2:4, necessary hold fast embedded in concrete, fixing in concrete with anchor fastners. finished with Polyurethane painting of approved colour complete all as per drawings and specifications and as directed by the Engineer-in-charge |
| 90 | Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc with PVC/Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item)a) With toughened float glass panes of 6.00 mm thickness |
| 91 | Providing and laying in position Reinforced Cement Concrete(RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications. a) for RCC all grades in superstructure upto 20.00 metre heightNote: The minimum cement content for RCC works should be as perthe latest revision of the relevant IS code |
| 92 | Providing, centering, shuttering Formwork using steelplates, timber planks for all types of structures including necessary strutting, proping, staging, supports, bracings etc. and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levelsa) For Super Structure |
| 93 | Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings.Steel supplied by the contractor. Using TMT bars of specified grades of all dia bars to be supplied by the contractor manufactured confirming to IS 1786 |
| 94 | Providing and constructing Half brick masonry using Flyash/ Flyash Lime bricks with minimum70kg/Sq.cms trength of approved make and size in partition walls in C.M1:4 (using crushed sand) including scaffolding, raking out joints, curing etc.complete and with stiffners of RCC1:2:4 (105 X 75mm size) at every 900mm height including form work curing etc. complete as per specifications but excluding reinforcement in Super Structure up to Floor - II level. (Reinforcement will be paid under relevant item) |
| 95 | Providing & fixing in position Heady Duty Thermocole in Machine Foundations including cutting to required size, wrapped in 200 micron thick polythelene sheets, sticking with bitumen and sealing the top with approved bitumastic compound etc complete 50 mm thick (18 Kg/CuM) |
| 96 | Dismantling plain cement concrete manually/ by mechanical means carefully without damaging adjacent structures including disposal of debris within 200m lead as per direction of Engineer-in-charge. |
| 97 | Providing and Fixing in position Suspended false ceiling system using 600x600mm Calcium Silicate Ceiling tiles Tiles having 15mm densified edges and 100% humidity resistance, incombustible as per BS476 partIV with thermal conductivity of 0.043w/m KC and approvred surface design and edg eprofile placed in a suspended grid of size of 600x600mm made of hot-dipped G.I steel sections having an exposed surface capping of pre-finished baked polyester painted coil where in the main tee of size 24mmx38mmx0.33mm shall be suspended at 1200mm centres along the length of ceiling with 4mm dia G.I wire with necessary level adjusters and cross tees of size 24x28x0.33mmx1200mm shall be inserted into slots between the main tees at 600mm centres and thereafter in direction vertical to the longer tees, crosstees of size 24x28x0.33mmx600mm shall be inserted to form a grid size of 600x600mm resting on the perifery walls on wall angles of size 20mm x 20mm x 3000 mm x 0.40 mm thickness.The rate shall include providing necessary openings for lightfixtures, diffusers, trapdoors etc to be made as per layout drawings. The work shall be carried out as per directions of Engineer-in-charge. The main tees to be suspended from the ceiling/soffit with the help of matal dash fastners of 6mmx50mm, soffit clits of 25mm x 35mm x 1.60mm and 4mm dia G.I wire with galvanised spring steel levelling clips. the entire grid system shall be designed to bear a distributed load of minimum 15kg/Sq.m (Only calcium silicate false ceiling area will be measured for the purpose of payment)a) tile models of Fine Fissured |
| 98 | Providing and laying Self levelling Epoxy flooring, including preparation of the surface, primer coat, screeding & levelling coat and finishing coat with Polyurethene coat of approved colour and shade of approved make all as per manufacturers specifications complete as directed at site by the Engineer-in-charge (This Job to be carried out through a specialized approved agency)a) 4mm thickness |
| 99 | SITC of MCC panel as per TSS-E-1 |
| 100 | SITC of Distribution Board as per TSS-E-2 |
| 101 | 20 A/way, 12 way, TPN DB with SP outlets (Total 36 Nos. SP MCB outlets) and 63 A, 4 pole MCB and 63 A, 4 pole ELCB (30 mA ) incomer (Refered as PDB) (VTPN type) |
| 102 | 12 way TPN with TP & SP outlets and 63 A, 4 pole MCB and 63 A, 4 pole RCCB (30 mA), incomer (Refered as UPS DB) (VTPN type) |
| 103 | 6 A/way, 6 way SP outlets (Total 12 Nos SP MCB as outgoing) and 32 A, 4 pole MCB and 3 nos. 2 pole 40A RCCB (30 mA) incomer (Refered as LDB) |
| 104 | Supply, Installation, testing and commissioning of following sizes Power Cables as per TSS-E-3 |
| 105 | 3.5C× 240 Sqmm 1.1kV Aluminium conductor XLPE insulated armoured cable |
| 106 | 4C× 25 Sqmm 1.1kV Aluminium conductor XLPE insulated armoured cable |
| 107 | 4C× 6 Sqmm 1.1kV Copper conductor XLPE insulated armoured cable |
| 108 | 4C× 2.5 Sqmm 1.1kV Copper conductor XLPE insulated armoured cable |
| 109 | 3C× 2.5 Sqmm 1.1kV Copper conductor XLPE insulated armoured cable |
| 110 | 3Cx 25 Sqmm 1.1kV Copper conductor XLPE insulated armoured cable |
| 111 | SITC of CAT-6 armoured cable as per TSS E-4 |
| 112 | SITC of 10pair telephone cable as per TSS E-5 |
| 113 | SITC of End Termination of following sizes of Power cables as per TSS-E-6 |
| 114 | 3.5C× 240 Sqmm 1.1kV XLPE insulated AL conductor armoured cable |
| 115 | 4C× 2.5 Sqmm 1.1kV XLPE insulated Cu conductor armoured cable |
| 116 | 3C× 2.5 Sqmm 1.1kV XLPE insulated Cu conductor armoured cable |
| 117 | 4C× 6 Sqmm 1.1kV XLPE insulated Cu conductor armpured cable |
| 118 | 4C× 25 Sqmm 1.1kV XLPE insulated Al conductor armoured cable |
| 119 | 3Cx25 Sqmm 1.1kV XLPE insulated Cu conductor armoured cable |
| 120 | SITC of End Termination of armoured CAT 6 cable as per TSS-E-7 |
| 121 | SITC of End Termination of 10 pair telephone cable as per TSS-E-8 |
| 122 | SITC of Point wiring for lighting, power, FA, PA, telephone, LAN, push button station etc. including all for clean room as follows and as per TSS-E-9 |
| 123 | SITC of Primary Light Point |
| 124 | SITC of Secondary Light Point |
| 125 | SITC of Network Point |
| 126 | SITC of Primary Power Point (1no. 16A and 1no.6A) on Wall Panel |
| 127 | SITC of Primary Power Point (1no. 16A and 1no.6A)on working Table |
| 128 | SITC of Secondary Power Point (1no. 16A and 1no.6A) on Working Table |
| 129 | SITC of Industrial power point on working Table |
| 130 | SITC of 3 phase (3P+N+E industrial plug & socket with RCBO ) point |
| 131 | SITC of FA system Point wiring |
| 132 | SITC of Push Button Station with self illuminated 1 Start,1 Stop and wiring |
| 133 | SITC of clean room LED fixture as per TSS-E-10 |
| 134 | SITC of Recess LED Fixture as per TSS E-11 |
| 135 | SITC of 25mm x3mm Tinned Cu earthing strip as per TSS-E-12 |
| 136 | SITC of 8 SWG Cu earthing wire as per TSS-E-13 |
| 137 | SITC of Fire Alarm System as per as per TSS-E-14 |
| 138 | Optical type smoke detector |
| 139 | Electronic Hooter |
| 140 | Manual call point |
| 141 | SITC of 15 U size double section wall mounted Networking Mounting Rack as per TSS-E-15 |
| 142 | SITC of 24 port patch max panel (jack panel) existing mounting racks as per TSS-E-16 |
| 143 | SITC of MS powder coated item as per TSS-E-17 |
| 144 | SITC of Push Button Station as per TSS-E-18 |
| 145 | Modification and SITC of 400A MCCB in existing Panel with all accessories as per TSS-E-19 |
| 146 | SITC of Self illuminated signage as per TSS-E-20 |
| 147 | SITC 450mmX 50mm Laddar type cable tray as per TSS-E-21 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 30 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 40 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender