Public Administrative Department Local Bodies Closing in 11 days TDR #57009710

Tender For Package No. Ap10 Piv 02 - L021-Holagunda Marlamadiki Road To Nagarakanvi Of Holagunda Mandal Of Kurnool District Estimate Cost Rs.265.00 Lakhs + Rs.17.23 Lakhs (Mtc)

Issued by Local Bodies · Kurnool, Andhra Pradesh
Tender Value
2 Crore
Estimated cost
Bid Submission
28 Aug 2026
11 days left
EMD
4.01 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kurnool → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Package No. Ap10 Piv 02 - L021-Holagunda Marlamadiki Road To Nagarakanvi Of Holagunda Mandal Of Kurnool District Estimate Cost Rs.265.00 Lakhs + Rs.17.23 Lakhs (Mtc)

BOQ

Name of Work:- Package No. AP10 PIV 02 - L021-Holagunda Marlamadiki road to Nagarakanvi of Holagunda Mandal of Kurnool District Estimate Cost Rs.265.00 Lakhs + Rs.17.23 Lakhs (Mtc)
Sl. No. Item Description
1Road Portion
2Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201 MORD, including Overhead charges & Contractor's profit but excluding GST, etc., complete.
3Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting with vibratory roller 80-100 KN to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 MORD, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete.
4Construction of improved subgrade by providing selected earth having minimum CBR of 10%, MDD not less than 1.85 g/cc with LL & PI not more than 40% and 20 respectively and spreading in uniform layers with tractor grader on prepared surface, and compacted at OMC with vibratory roller 80-100 kN to meet requirement of Table 300.2 with as per Technical Specification Clause 303 MORD / 305 MORTH, by using machinery including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete.
5Construction of granular sub-base by providing well graded material(Table 400.1) with Grading III Material(HBG M/C +Stone dust) CBR Value not less than 20 and PI Value less than 6 spreading in uniform layers with Tractor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with Vibratory Roller to achieve the desired density, complete as per Technical Specification Clause 401 MORD, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete.
6Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with Vibratory Roller 80-100 kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406 MORD, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete.
7Providing and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 MORD (for use on Wet mix macadam & WBM), including Overhead charges & Contractor's profit but excluding GST, etc., complete.
8Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503 MORD,, including Overhead charges & Contractor's profit but excluding GST, etc., complete.
9Providing, laying and rolling of close-graded premix surfacing (Mix seal surfacing) material of 20 mm thickness composed of 13.2 mm to 0.09 mm (Type-B) aggregates as per Table 500.15 of MORD using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant by manual means, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 507 MORD'2014, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete.
10Construction of Shoulders by providing selected earth having minimum CBR of 10%, MDD not less than 1.85 g/cc with LL & PI not more than 40% and 20 respectively and spreading in uniform layers with tractor grader on prepared surface, and compacted at OMC with vibratory roller 80-100 kN to meet requirement of Table 300.2 with as per Technical Specification Clause 303 & 407 MORD, by using machinery, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete.
11Construction of un-reinforced, pannelled cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, as per design, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork etc complete as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation, admixtures as approved, curing of concrete slab for 14-days, using curing compound (where specified) and water and contraction sawn joint groove (using daimond studded nblades) 3 to 5 mm wide and 1/3rd to 1/4th depth of the slab + or - 5mm or .Thecontraction joint shall be cut as soon as the concrete as under goneinitial hardening and as hard enogh to take up the load of joint swaing machine with out causing damage to the slab. The joint ceilling compound shall not be poured bitumen type having flexibility, resistaance to age hardening and durability of the sealant shall be in accordance with BS 5212 (part-2) with all leads and lifts and coat and conveyance of all materials for 100 thickness for forming the panels of 0.75 X 0.75 mts size as per drawing and Technical Specification Clause 1501 including contractors profit & Over head charges,but excluding Seig Charges & GST etc,. Complete.
12Widening of single row 600 mm dia Pipe Culverts - 2 No.s
13Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - For Foundations
14Providing concrete for plain concrete M 10 grade in open foundations using 40 mm nominal size Graded hard stone aggregate (HBG), mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - For levelling course.
15Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in foundation complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - for Head walls of pipe culverts.
16Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head wall and parapets. Tech Specification Clause 1101.6 MORD, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - 600mm dia RCC NP3 Pipes(P/E) - For Pipe Culverts
17Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 MORD, including contractors profit & Over head charges, but excluding GST etc., complete for RCC raining and RCC Guide posts.
18Single row 1000 mm dia Pipe Culverts (10 mts) skew - 3 No.s
19Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - For Foundations
20Providing concrete for plain concrete M 10 grade in open foundations using 40 mm nominal size Graded hard stone aggregate (HBG), mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - For levelling course.
21Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in foundation complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - for Head walls of pipe culverts.
22Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head wall and parapets. Tech Specification Clause 1101.6 MORD, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - 1000mm dia RCC NP3 Pipes(P/E) - For Pipe Culverts
23Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 MORD, including contractors profit & Over head charges, but excluding GST etc., complete for RCC raining and RCC Guide posts.
24Vented Cause way with 1 vent of 2 mts span RCC Slab Culvert in Km 0/885 to 0/965 - 1 No.
25Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202 MORD / MORTH, including contractors profit & Over head charges, but excluding GST etc., complete (RR Masonary in CM)
26Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - For Foundations
27Providing concrete for plain concrete M 10 grade in open foundations using 40 mm nominal size Graded hard stone aggregate (HBG), mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - For levelling course.
28Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in foundation complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - for Head walls of pipe culverts.
29Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - for Abutments & Wing walls.
30Reinforced cement concrete M25 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 MORD and 1500, 1700 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete (upto 5m height) for Bed Blocks.
31Providing and laying reinforced cement concrete M25 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 MORD / Sections 1500, 1600 & 1700 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete up to 5m height. - For Super Structure (Deck slab)
32Providing and laying cement concrete wearing course M 30 (Design Mix) grade using 20 & 10mm metal (HBG) mechanically mixed excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1404.2.2 MORD and 2702 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete
33Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 MORD / 2706 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST, etc., complete.
34Cost, supply and fixing of Bituminous Mastic Pad 25.4 mm including cost and conveyance and all labour charges and including Overhead charges & Contractor's profit but excluding GST, etc., complete.
35Supplying, fitting and placing HYSD bar reinforcement (Fe 500) in substructure complete as per drawings and technical specification Clauses 1001 & 1206 MORD / Sections 1600 & 2200 MORTH for Bars below 36 mm dia including over laps and wastage, where they are not welded, including Overhead charges & Contractor's profit but excluding GST, etc., complete - For Sub Structures.
36Supplying, fitting, and placing HYSD bar reinforcement (Fe 500) in superstructure complete as per drawing and technical specifications Clauses 1001 and 1401 MORD / 1600 MORTH, for Bars below 36 mm dia including over laps and wastage, where they are not welded ,including Overhead charges & Contractor's profit but excluding GST, etc., complete - For Super Structures
37Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum size of coarse agregate not exceeding 25mm and cement content in the mix to be 350 kg /cum (Ordinary portland cement ) with minimum water cement ratio of 0.45, mixed in a concrete mixer and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and construction joints, applying debonding strips, primer bitumenous sealant, admixers as adopted, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501.22 MORD including cost of materials, labour charges, conveyance, hire charges of machinaries etc complete as per direction of Engineer in charge for CC pavement inlcuding contractors profit & Over head charges, but excluding GST and seigniorage etc., complete For 170mm thick with 3.25m joint spacing.
38Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 MORD. excluding GST & Seigniorage Charges. etc., complete.
39Vented Cause way with 1 vent of 2 mts span RCC Slab Culvert in Km 0/885 to 0/965 - 1 No.
40Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202 MORD / MORTH, including contractors profit & Over head charges, but excluding GST etc., complete (RR Masonary in CM)
41Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - For Foundations
42Providing concrete for plain concrete M 10 grade in open foundations using 40 mm nominal size Graded hard stone aggregate (HBG), mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - For levelling course.
43Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in foundation complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - for Head walls of pipe culverts.
44Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete - for Abutments & Wing walls.
45Reinforced cement concrete M25 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 MORD and 1500, 1700 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete (upto 5m height) for Bed Blocks.
46Providing and laying reinforced cement concrete M25 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 MORD / Sections 1500, 1600 & 1700 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete up to 5m height. - For Super Structure (Deck slab)
47Providing and laying cement concrete wearing course M 30 (Design Mix) grade using 20 & 10mm metal (HBG) mechanically mixed excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1404.2.2 MORD and 2702 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete
48Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 MORD / 2706 & 2200 MORTH, including Overhead charges & Contractor's profit but excluding GST, etc., complete.
49Cost, supply and fixing of Bituminous Mastic Pad 25.4 mm including cost and conveyance and all labour charges and including Overhead charges & Contractor's profit but excluding GST, etc., complete.
50Supplying, fitting and placing HYSD bar reinforcement (Fe 500) in substructure complete as per drawings and technical specification Clauses 1001 & 1206 MORD / Sections 1600 & 2200 MORTH for Bars below 36 mm dia including over laps and wastage, where they are not welded, including Overhead charges & Contractor's profit but excluding GST, etc., complete - For Sub Structures.
51Supplying, fitting, and placing HYSD bar reinforcement (Fe 500) in superstructure complete as per drawing and technical specifications Clauses 1001 and 1401 MORD / 1600 MORTH, for Bars below 36 mm dia including over laps and wastage, where they are not welded ,including Overhead charges & Contractor's profit but excluding GST, etc., complete - For Super Structures
52Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 MORD. excluding GST & Seigniorage Charges. etc., complete.
53Road Furniture
54Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 MORD / 804 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete (precast) for Ordinary KM Stone.
55Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 MORD / 804 MORTH, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete (precast) for 200 M Stone.
56Providing & fixing of typical PMGSY informatory sign board with LOGO as per MORD secifications and drawing Consisting of Three boards made of encapsulated lens type Retro reflective sheeting as per IRC 67 fixed over Alluminium Composite Material of 4mm thickness fixed on a frame of 25x25x5mm MS angle alround edges and MS flats 25x5mm in the middle duly welding he lower plate and middle plate to 2 nos of verticle posts 75x75 x6mm MS square hallow section of 2.80m length welded with 200x200x5mm thick MS base plate at bottom duly embedded in CC M20 grade blocks of 450x450x600mm, 600mm below ground level and the top most diamond plate welded to middle plate by 47x47 X6mms MS square hallow section tube duly supported by 47x47x6mm MS square tube in between two vertical posts including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheetwith primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges, Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete for finished item of work.
57Providing and fixing of Maintenance information board as per MoRD specifications and drawings made of encapsulated lens type Retro reflective sheeting as per IRC:67 fixed over Alluminium Composite Material of 4mm thickness and size of 900 x 1500 mm fixed on a frame of 25X25X6mm thick MS angles alround edges and MS flats 25x5mm in the middle and welded to 75 x 5 mm size MS flats on back and welded to 75 x 75 x6mm MS Square hollow section of height 3.00m length welded with base MS plate of 300x300x5mm thick base MS plate at bottom duly embedded in to cement concrete M20 grade of size 600 x 600 x 750 mm, 750 mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges, Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete for finished item of work.
58Providing and fixing of Citizen information board as per MoRD specifications and drawings consists of two boards made of encapsulated lens type Retro reflective sheeting as per IRC 67 fixed over Alluminium Composite Material of 4mm thickness and 900/750mm size fixed on a frame of 25x25x5mm thick MS angle alround edges and 25x5mm thick MS flats in the middle welded to 75 x 5 mm size MS Flats on back and welded to 75x75x6mm MS square hallow sections of length 3.05m welded with 300x300x5mm MS Base plate at bottom duly embedded in cement concrete M20 grade of size 600x600x750 mm, 750mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges, Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete for finished item of work.
59Providing and fixing PMGSY Logo Board at the specified locations as per the approved drawings and specifications, including providing and fixing the PMGSY logo board of required size, fabricated from approved steel sheet/plate with suitable angle-iron frame and steel tubular supports, complete with necessary welding, cutting, drilling, nuts, bolts and fixtures; painting with one coat of approved primer and two coats of approved synthetic enamel/epoxy paint, including lettering, borders and PMGSY logo in approved colours with retro-reflective/luminous paint as specified; including excavation, providing and laying M15 grade cement concrete foundation, fixing of posts in foundation, backfilling, finishing and all materials, labour, tools and plant complete as directed by the Engineer and conforming to the MoRD Specifications for Rural Roads/NRIDA PMGSY specifications and approved drawings for every 2.00 KM
60Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign boards as per MoRD specifications and drawings made of encapsulated lens type reflective sheeting as per IRC:67 fixed over aluminium sheeting 4 mm thick fixed on 25x25x5mm size MS angles alround and 25mm x5mm size MS flats in middle supported on 75x75 x6mm MS angle section post welded with 50x50x5 mm MS angle hold fast at bottom firmly fixed in the ground by means of properly designed foundation with M 20 cement concrete 450 x450x600 mm,600 mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges, Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete for finished item of work - Cautionary signs (equilateral triangle of size 600 X 600mm size).
61Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign boards as per MoRD specifications and drawings made of encapsulated lens type reflective sheeting as per IRC:67 fixed over aluminium sheeting 4 mm thick fixed on 25x25x5mm size MS angles alround and 25mm x5mm size MS flats in middle supported on 75x75 x6mm MS angle section post welded with 50x50x5 mm MS angle hold fast at bottom firmly fixed in the ground by means of properly designed foundation with M 20 cement concrete 450 x450x600 mm,600 mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges, Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete for finished item of work - Mandatory signs (Circular of size 600 mm).
62Providing and erecting direction and place identification retro-refectorised sign as per MoRD specifications and drawings made of encapsulated lens type refective type sheeting as per IRC 67 fixed over aluiminium sheeting,4mm thick with area not exceeding 0.90 sqm board fixed on 25x25x5mm size MS frame alround and 25mm x5mm size MS flat in the middle supported on 75x75 x6mm MS angle section posts welded with 50x50x5 mm MS hold fast at bottom, firmly fixed in the ground by means of properly designed foundation with M 20 cement concrete 450 x450x600 mm,600 mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges, Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete for finished item of work.
63Pavement markings with hot line applied Thermo plastic compound 2.50 mm thick including reflecting glass beads at 250 gms/sqm, thickness of 2.5mm is exclusive of surface applied glass beads for providing centerline marking 300 cms length and 10cm width with a gap of 450 cms including cost and convenyace of all materials equipment machinary and labour with all leads and lifts loading and unloading charges necessary for sucessful completion of work as directed by the Engineer-in-Charge and confirming to IS 164 - 1981 (1st revison reaffirmed in 1986) and clause 803 of MOST specification for roads and bridge works and also confirming to IRC 35 -1997 including cost and conveyance of all materials, all labour charges, Overhead charges & Contractor's profit but excluding GST etc., complete for finished item of work.
64Supplying & Fixing of Moulded Shanks Raised Pavement Markers made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No. RW/NH/33023/10-97 – DO III Dt 11.06.1997. The height, width and length shall not exceed 50 mm, 100 mm and 100 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 700 Kgf. Fixing will be by drilling holes on the road for the twin shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the Engineer-in-Charge including cost and conveyance of all materials, all labour charges, Overhead charges & Contractor's profit but excluding GST etc., complete for finished item of work.
65Supply and Installation of Hazard Markers using M.S. Angle of size 55X55X6mm and 120 cm high above ground level painted with two coats of black & white stripes of 15cm wide with first quality synthetic enamel paint over one coat of appropriate primer of approved brand, colour, with 30cm X 90cm retro reflective sheeting type III/IV of yellow colour fixed at top over 1.5mm aluminium sheet with standard supports consisting of alternately black and yellow stripes, with black stripes in screen printing sloping downward at an angle of 45degree towards the side of the obstruction on which the traffic is pass and buried in to the ground in a trench of size 30cm X 30cm, and 50cm depth filled with CC 1:2:4 including cost and conveyance of all materials, equipment, machinery and labour with all lead and lifts, loading and unloading charges necessary for successful completion of works as directed by the Engineer-in-Charge and conforming to IRC 79-1981 & MoRTH specification no. 805 and approved drawings etc., complete for finished item of work including cost and conveyance of all materials, all labour charges, Overhead charges & Contractor's profit but excluding GST etc., complete for finished item of work.
66Construction of RCC guide posts of 250 mm dia M 20 grade cast-in-situ with 20 mm nominal size aggregate (HBG), true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2, including Overhead charges & Contractor's profit but excluding GST and Seigniorage charges, etc., complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57009710
AUTHORITY Local Bodies
TENDER VALUE 2 Crore
LAST DATE 28-08-2026
Authority
Authority Name Panchayat Raj Department
Work Description Tender for Package No. Ap10 Piv 02 - L021-Holagunda Marlamadiki Road To Nagarakanvi Of Holagunda Mandal Of Kurnool District Estimate Cost Rs.265.00 Lakhs + Rs.17.23 Lakhs (Mtc)
Basic Detail
Tender No NIT No.93/2026-27 dt.07.08.2026 of Engineer-in-chief, PR, Vijayawada
Bidding Type Tender
Location
City Kurnool
State Andhra Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 28 Aug 2026
Open Date 01 Sep 2026
Finance
Tender Value 2 Crore
Tender Fee Ref. Documents
EMD 4.01 Lakhs
Exemption Not Available
Document List
Tendernotice_3.pdf
86eb8655-4c5e-4e6c-9d3c-b91d3130aed1.html
BOQ_234651.xls
Tendernotice_1.pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_3.pdf

html

86eb8655-4c5e-4e6c-9d3c-b91d3130aed1.html

xls

BOQ_234651.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders