Defence Statutory Bodies & Commissions/Committees Closing in 34 days TDR #57004841

Tender For Provision Of Living-In-Accomodation For Agniveer Vayu Men/Women Under Ge(P) Af Kalaikunda

Issued by Statutory Bodies & Commissions/Committees · Medinipur West, West Bengal
Tender Value
3.20 Crore
Estimated cost
Bid Submission
19 Sep 2026
34 days left
EMD
3.95 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Medinipur West → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Living-In-Accomodation For Agniveer Vayu Men/Women Under Ge(P) Af Kalaikunda

BOQ

Name of Work:- PROVISION OF LIVING-IN-ACCOMODATION FOR AGNIVEER VAYU MEN/WOMEN UNDER GE(P) AF KALAIKUNDA
Sl. No. Item Description
1BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: PROVISION OF LIVING-IN-ACCOMODATION FOR AGNIVEER VAYU MEN/WOMEN UNDER GE(P) AF KALAIKUNDA Contract No: CE(AF)SZ/KKD/ OF 2026-2027 File No: 88900/KKD/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES
2Sch 'A' Part-I (BUILDING WORK)Construction of one block of Single Living Accomodation for 24 Agniveer Vayu Men/Women in double storey (G+1) configuration with permanent specifications including ATT, mosquito proofing, roof treatment etc. complete all as directed and shown in drawings.
3Construction of one block of Two wheeler & Car Parking with permanent specification including RCC foundation, RCC framed construction, roof treatment etc all as directed and shown in drawings.
4Total amount of Such 'A' Part-II (SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK)Details of prepriced Schedule is given in tender documents
5Total amount of Such 'A' Part-III (INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents
6Total amount of Such 'A' Part-IV (INTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents
7Total amount of Such 'A' Part-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents
8Total amount of Such 'A' Part-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
9Total amount of Such 'A' Part-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
10Total amount of Such 'A' Part-VIII (BOUNDARY WALL) Details of prepriced Schedule is given in tender documents
11Total amount of Such 'A' Part-IX (WATER COOLER) Details of prepriced Schedule is given in tender documents
12Total amount of Such 'A' Part-X (DEHUMIDIFIER) Details of prepriced Schedule is given in tender documents
13Total amount of Such 'A' Part-XI (SOLAR WATER HEATING SYSTEM) Details of prepriced Schedule is given in tender documents
14Total amount of Such 'A' Part-XII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
15Total amount of Such 'A' Part-XIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
16SCHEDULE \\"A\\" PART -XIV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only.
17INTERNAL ELECTRIFICATIONS&F 10/12 watt rechargeable emergency inverter LED bulb,cool day light up to 4 hours battery backup all as specified and directed
18SEWAGE DISPOSAL M&L for LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 30 Users conventional type complete all as specified & directed.NOTE:-Foundation shall be as per manufacturer's instructions and all as specified and directed.
19M&L for Construction of Soakage wells size 2.4m dia x 3 mtr effective depth, excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC complete filled with brick bats complete all as specified and as directed.
20S&F factory made precast RCPC manholes covers of clear internal dia 600mm, 5T load capacity, confirming to IS 12592:2002 placed/fixed in position complete all as specified and as directed
21WATER COOLERS&F Reverse osmosis plant, heavy skid with pressure gauge, efficient power supply, durable membrane housing, taste adjuster, with SLX solenopid valve for versatile use of output capacity of 25 ltrs per hour.complete all as specified and as directed.
22S&F voltage stabiliser for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilised at 230V with accuracy at +/- 2.5% and of capacity 1.0 KVA complete all as specified and as directed
23DEHUMIDIFIERSupply, installation, testing & commissioning of Humidifier of capacity not less than180 CFM with digital Humidistat, Dehumidifier equipped with Microprocessor based controlling system having LED display, CNC fabricated unit with pre coated MS sheet, High temperatire thermostat output, Additional cooling thermostat, Electrical interlocking of fan motor, heaters and rotor drive, PTFE bonded silicon bulb seal designed to minimise air leakage conforming to ISO 9001:2015 and ISI 14001:2015 certifications complete all as specified and as directed.
24Supply and installation of Rechargeable desk light with a built in lithium ion battery minimum 200 mAh, flexible and foldable with goose neck, polycarbonate material with in built LED light of 5W cool white colour complete all as specified and as directed
25EXTERNAL ELECTRIFICATIONSupply,installation,testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT Feeder Pillar fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 200 Amps ( Size of copper strip should not be less than 25x4 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following:-
26(A) Incoming : (i) MCCB 100 Amps rating, 4 pole , 415 V, AC, 50 HZ, thermal Magnetic release type, having thermal release range 100-125 Amp with adjustable overload and short circuit setting, Ics=100 % Icu , Service breaking capacity 25 kA - 01 Nos with rotatary handle (ii) Digital 3 Phase Ammeter, Flush mounting, 96 x 96 mm, Accuracy class 1.0, with inbuilt selector switch for three phase, CT/PT site programable ---01 Nos with Suitable CT as per MCCB and wiring with copper wire.(iii) Digital 3 Phase Voltmeter, Flush mounting, 96 x 96 mm, Accuracy class 1.0, with inbuilt selector switch for three phase, CT/PT site programable- 01 No(iv) Three indication lamps- 01 Set (Red, Yellow, Blue). (B) Outgoing : (i) MCCB 63 Amp ,3 Pole, 25 kA, 415 volts, AC, 50Hz thermal adjustable type - 02 Nos (1W+1S) (ii) MCB TPN 32A 10 KA , 415V-02Nos (01 For Street Light + 01 Spare ) (iii) MCB SPN 20A 10 KA , 230V-02Nos ( 02 for Parking ) (iv) Astronomical Time Switch 16 Amps 24 hour programming type with ML-4 contractor 70A, 415 V, three phae, coil operating voltage 230 V, three point Auto manual switch 16 Amps for bypass system with 32A 4P MCCB adjustable (40% to 100%) Microprocessor release, 25KA complete including necessary connection.-01 Nos
27Supply and fix Thermo plastic terminal box of size not less than 130 x180 x 77 mm mm with locking arrangement and necessary mounting arrangement on pole with MS clamps, nut bolt and washers etc including 01 No MCB 6 Amps and PVC connector 3 phase for cable termination complete all as specified and directed.
28M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.complete all as specified and directed.
29Supply and fix street light bracket, bend to required size and shape, made out of 40 mm bore, galvanised iron pipe, medium grade tubing (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc. and two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
30EXTERNAL WATER SUPPLYConstruction of brick masonry valve pit / chember of internal dimension 90 cm x 90 cm x 90 cm depth( internal dimensions) with one brick thick wall of sub class 'B' old size bricks in CM (1:4) on 100 mm thick PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, including PCC (1:3:6) type CI (using 20 mm graded crushed stone aggregate) as in bedding and copping and 10 mm thick cement plaster in CM 1:4 internally and externally upto 15 cm below ground level providing valve pit 25x25x6 mm angle iron frame all round ther fixed point by means of 04 Nos holdfast 150 mm long made out of flat iron 25x6 mm embedded in PCC block 1:2:4 Type B1 (using 20mm graded crushed stone aggregates) 0f size 250x200x150 mm incluidng provision of hinges welded with MS cover and suitable locking arrangement including 65 mm dia Gogrej pad lock and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earthwork in soft/loose soil and removal of surplus soil to a distance not exceeding 50 m, complete all as specified & directed.
31Supply and laying 3 layer (inner antimicrobial, outer UV stabilised) ISI Marked, IS-15801, PP-R Pipes SDR 7.4(PN-16) and PP-R plain fittings in trenches/walls/ceilings or laying in floors of size outer dia 25 mm complete all as specified & directed.
32Supply and laying 3 layer (inner antimicrobial, outer UV stabilised) ISI Marked, IS-15801, PP-R Pipes SDR 7.4(PN-16) and PP-R plain fittings in trenches/walls/ceilings or laying in floors of size outer dia 63 mm complete all as specified & directed.
33Supply and fixing PP-R gate valves brass inserted as per requirement of size outer dia 25 mm complete all as specified & directed.
34Supply and fixing PP-R gate valves brass inserted as per requirement of size outer dia 63 mm complete all as specified & directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57004841
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 3.20 Crore
LAST DATE 19-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Living-In-Accomodation For Agniveer Vayu Men/Women Under Ge(P) Af Kalaikunda
Basic Detail
Tender No 88900/KKD/E8
Bidding Type Tender
Location
City Medinipur West
State West Bengal
Key Dates
Publish Date 14 Aug 2026
Submission Date 19 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 3.20 Crore
Tender Fee 2000
EMD 3.95 Lakhs
Exemption Available
Document List
Tender.pdf
Tendernotice_1.pdf
DRAWINGS.rar
PREPRICEDSCHEDULES.pdf
9e43b15f-4a8a-4875-bb82-3b70b30c8440.html
BOQ_878953.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 34 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 36 days

Tender Documents

Download All (ZIP) ↓
pdf

Tender.pdf

pdf

Tendernotice_1.pdf

rar

DRAWINGS.rar

pdf

PREPRICEDSCHEDULES.pdf

html

9e43b15f-4a8a-4875-bb82-3b70b30c8440.html

xls

BOQ_878953.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders