Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #57004826

Tender For Repair & Maintenance Of Electric Wiring Alongwith Connected Items In Officers/Jcos/Ors And Otm Accn Of D-I Zone & Ist Horse Area Under Age E/M Of Ge (S) Mamun.

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
30 Lakhs
Estimated cost
Bid Submission
03 Sep 2026
10 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair & Maintenance Of Electric Wiring Alongwith Connected Items In Officers/Jcos/Ors And Otm Accn Of D-I Zone & Ist Horse Area Under Age E/M Of Ge (S) Mamun.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Aug-2026 Corrigendum No. 1 BOQ 03-Sep-2026

BOQ

Name of Work:- Repair & Maint of electric wiring alongwith connected items in Officers/JCOs/ORs and OTM Accn of D-I Zone & Ist Horse area under AGE E/M of GE (S) Mamun.
Sl. No. Item Description
1Taking down copper /aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, ceilling roses, holder, regulators, etc, removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be made as per conditions separately) and making good surfaces, wall, floors etc.) complete all as specifiedand directed.
2M&L for Point wiring for one light point / fan point / bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed, FRLS , multistranded copper conductor cable (red, yellow & blue colour) in and including non metalic rigid PVC concealed conduit ISI marked, not less than 20mm dia, medium duty with all necessary fittings such as tee, elbow, socket including sunken steel boxes of suitable size with 3mm thick plastic laminated backelite sheet top for mounting switches sockets etc including FRLS PVC insulated unsheathed multistranded copper conductor cable of size 1.5sqmm (green colour) as continuous earth wire and connecting to earth dolly, and making good to distrubed surfaces of wall/floor to match to existing finishes etc complete all as specified and directed.Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
3All as per description of serial item No. 2.00 here in before but in existing PVC Conduit.
4All as per description of serial item No. 2.00 here in before but in & including PVC casing and capping with all the necessary fittings & accessories i.e Tee, elbow, socket etc.
5M&L for Point wiring for one 2 way light point etc controlled by two switches with copper conductor cable FRLS multistrand of size 1.5 Sqmm (red, yellow & blue colour) PVC insulated and unsheathed with 1.5 Sqmm PVC insulated copper conductor cable as earth wire (green colour), in and including non metalic rigid PVC Conduit of medium duty not less than 20mm dia and with sunk cast iron boxes covered with 3.00 mm thick plastic laminated sheet top cover for mounting switches, sockets, regulators etc. connecting to earth dolly and making good disturbed surfaces all as specified. Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
6All as per description of serial item No. 5.00 here in before but in existing conduit
7All as per description of serial item No. 5.00 here in before but in & including PVC casing and capping with all the necessary fittings & accessories i.e Tee, elbow, socket etc.
8M&L for Point wiring for one socket outlet 5 Amp 3/5 pin for independent board etc controlled by one switch with copper conductor cable FRLS multistrand of size 1.5 Sqmm (red, yellow & blue colour) PVC insulated and unsheathed with 1.5 Sqmm PVC insulated copper conductor cable as earth wire (green colour), in and including non metalic rigid PVC Conduit of medium duty not less than 20mm dia and with sunk cast iron boxes covered with 3.00 mm thick plastic laminated sheet top cover for mounting switches, sockets, regulators etc. connecting to earth dolly and making good disturbed surfaces all as specified and directed. Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
9All as per description of serial item No. 8.00 here in before but for one 3/5 pin 5 amps socket outlet in existing Conduit.
10All as per description of serial item No. 8.00 here in before but for one 3/5 pin 5 amps socket outlet in & including PVC casing & capping with all the necessary fittings & accessories i.e tee, elbow, socket etc.
11All as per description of serial item No. 8.00 here in before but for one 3/5 pin 5 amps socket outlet on the same board with other switches.
12All as per description of serial item No. 11.00 here in before but for one 3/5 pin 5 amps socket outlet on the same board with other switches in existing conduit.
13All as per description of serial item No. 11.00 here in before but for one 3/5 pin 5 amps socket outlet in & including PVC casing & capping with all the necessary fittings & accessories i.e tee, elbow, socket etc.
14M&L for point wiring for one 15 Amp independant socket outlet using 2.5 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cable (red, yellow & blue) drawn through & including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia, medium duty with all necessary fittings & accessaries including sunken steel boxex of suitable size covered with 3mm thick plastic laminated bakelite sheet top incl FRLS PVC insulated unsheathed multistranded copper conductor cable of size 2.5 Sqmm (green colour) earth wire connected to earth dolly complete all as specified and directed.Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
15All as per description of serial item No. 14.00 here in before but for 15 Amp socket outlet in existing Conduit.
16All as per description of serial item No. 14.00 here in before but for 15 Amp socket outlet in & including PVC casing and capping with all necessary fittings & accessories i.e. tee, elbow, socket etc.
17M&L for point wiring for one metal plug top for Geyser / AC using 4.0 Sqmm FRLS PVC insulated unsheathed multi-stranded copper conductor cable drawn through & including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia medium duty with all necessary fittings, incl FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4.0 Sqmm (green colour) earth wire connecting to earth dolly complete all as specified and directed.Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
18All as per description of serial item No. 17.00 here in before but for one metal plug top for Geyser / AC socket outlet in existing Conduit
19All as per description of serial item No. 17.00 here in before but for one metal plug top for Geyser / AC socket outlet & including PVC casing & capping with all the necessary fittings & accessories i.e tee, elbow, socket etc.
20S&F in repairs Switch piano flush button single pole one way 6 Amps 240 volts polycarbonate body complete all as specified and directed.
21S&F in repairs switch piano, flush button, single pole two way, 6 amps 240 Volt, polycarbonate body complete all as specified and directed.
22S&F in repairs bell push switch, piano flush button single pole, one way, 5 Amps 240 volts polycarbonate body complete all as specified and directed.
23S&F in repairs socket outlet multi purpose 2 & 3 pin, 6A, 230Volts flush type complete all as specified and directed.
24S&F in repairs socket outlet 2 in 1, 3 pin, 6 & 16 Amps, flush type, single pole, one way, 230 Volts complete all as specified and directed.
25S&F in repairs switch piano, flush type, single pole, one way, 16 Amps 230 Volts complete all as specified and directed.
26S&F in repairs stepped type electronic mini/deluxe fan regulator 100 Watt rotary step all as specified and directed.
27M&L for modular point wiring for one light/fan/bell point controlled by one switch complete with 1.5 Sqmm multistranded FRLS PVC insulated unsheathed, FRLS, multistranded copper conductor cable 1100 volts grade (red, yellow & blue) in and including medium duty non metallic rigid PVC concealed conduit 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC (green) insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size including modular sheets of suitable module and back plates etc. complete all as specified and directed.Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
28All as per description all serial item No. 27.00 here-in-before but in existing PVC conduit
29All as per description of serial item No. 27.00 here in before but in & including PVC casing and capping with all the necessary fittings & accessories i.e Tee, elbow, socket etc.
30M&L for modular point wiring for one 2 way light point etc controlled by two switches with 1.5 Sqmm multistranded FRLS PVC insulated unsheathed, FRLS, multistranded copper conductor cable 1100 volts grade (red, yellow & blue) in and including medium duty non metallic rigid PVC concealed conduit 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC (green) insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size including modular sheets of suitable module and back plates etc. complete all as specified and directed.Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
31All as per description all serial item No. 30.00 here-in-before but in existing PVC conduit
32All as per description of serial item No. 30.00 here in before but in & including PVC casing and capping with all the necessary fittings & accessories i.e Tee, elbow, socket etc.
33M&L for modular point wiring for one socket outlet 5 Amp 3/5 pin for independent board etc controlled by one switch with 1.5 Sqmm multistranded FRLS PVC insulated unsheathed, FRLS, multistranded copper conductor cable 1100 volts grade (red, yellow & blue) in and including medium duty non metallic rigid PVC concealed conduit 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC (green) insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size including modular sheets of suitable module and back plates etc. complete all as specified and directed.Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
34All as per description all serial item No. 33.00 here-in-before but in existing PVC conduit
35All as per description of serial item No. 33.00 here in before but in & including PVC casing and capping with all the necessary fittings & accessories i.e Tee, elbow, socket etc.
36All as per description of serial item No. 33.00 here in before but for one 3/5 pin 5 amps socket outlet on the same board with other switches.
37All as per description of serial item No. 36.00 here in before but for one 3/5 pin 5 amps socket outlet on the same board with other switches in existing conduit.
38All as per description of serial item No. 36.00 here in before but for one 3/5 pin 5 amps socket outlet in & including PVC casing & capping with all the necessary fittings & accessories i.e tee, elbow, socket etc.
39M&L for point wiring for one 15 Amp independant socket outlet using 2.5 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cable (red, yellow & blue) drawn through & including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia, medium duty with all necessary fittings & accessaries including sunken steel boxex of suitable size covered with 3mm thick plastic laminated bakelite sheet top incl FRLS PVC insulated unsheathed multistranded copper conductor cable of size 2.5 Sqmm (green colour) earth wire connected to earth dolly complete all as specified and directed.Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
40All as per description all serial item No. 39.00 here-in-before but in existing PVC conduit
41All as per description all serial item No. 39.00 here-in-before but in in & including PVC casing and capping with all the necessary fittings & accessories i.e Tee, elbow, socket etc.
42M&L for modular point wiring for one metal plug top for Geyser / AC using 4 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cable drawn (red, yellow & blue) through & including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia, medium duty with all necessary fittings & accessaries including sunken steel boxex of suitable size covered with 3mm thick plastic laminated bakelite sheet top incl FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4 Sqmm (green colour) earth wire connected to earth dolly complete all as specified and directed
43All as per description all serial item No. 42.00 here-in-before but in existing PVC conduit
44All as per description of serial item No. 42.00 here in before but in & including PVC casing and capping with all the necessary fittings & accessories i.e Tee, elbow, socket etc.
45S&F in repairs modular switch, one module, 1 way, 10 Amps 240 volts complete all as specified and directed.
46S&F in repairs modular switch, one module, 1 way, 16 Amps 240 volts complete all as specified and directed.
47S&F in repairs modular bell push 6A, 240 volts, 1 Module complete all as specified and directed.
48S&F in repairs modular switch, two way, 6A, 240 volts, 1 Module complete all as specified and directed.
49S&F in repairs modular socket 6A, 240 volts 2 & 3 pin, 2 Module complete all as specified and directed.
50S&F in repairs modular socket, 6A & 16A, 240 volts, 2 & 3 pin, 2 Module complete all as specified and directed.
51S&F in repairs modular step type fan regulator 120W, 240 volts, 2 Module, complete all as specified and directed.
52S&F in repairs ceiling rose, 3 phase PVC / polycarbonate, isolated body complete all as specified and directed.
53S&F in repairs lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete complete all as specified and directed.
54S&F in repairs LED Lamp of 9W, Base B22, BEE 3 Star complete all as specified and directed.
55Supply & fix in repairs LED tube light fittings (4 feet long), wall mounted 1x20 watt 6500K, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with all accessories and making connection using 2 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
56S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
57S&F in repairs Energy efficient LED ceiling light 15W of size 1 feet x1 feet complete with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
58S&F in repairs Energy efficient LED ceiling/surface light of 12W to 15W, circular shape complete with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
59S&F in repairs LED light fitting, mirror type with high out put diffuser, 2 feet,10 watt, 220 volt, AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed..
60S&F in repairs LED Bulk Head luminaries, 10W complete with all accessories and including connector and connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete.
61S&F in repairs decorative wall light white in colour made up of poly carbonate including 9 watt retrofit LED Lamp complete all as specified and directed.
62S&F in repairs building security LED light luminaire 30 W, IP 66, IK-07, AC 230 volts, made up of pressure di-cast iron housing complete making connection using PVC insulated and sheathed3 core multi stranded copper conductor cable of size 0.50 Sqmm from ceiling rose including MS bracket made of 25/32mm GI pipe bent to shape, fixed to wall with clamps and nurs & bolts for mounting fittings complete all as specified and directed.
63Note for srl item No 53 to 62 above:- 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70.4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be >= 100 Lm/W.6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. Lenses shall be Modular Type. 8. PCB used shall be MC PCB type. 9. CA No. shall be written on each fitting before installation. 10. The name of manufacturer to be embossed on the fitting.
6411. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.12. The defect liability period of LED lights shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over for replacement. 13. A guarantee of 05 years shall be provided by contractor supported by OEM covering all parts of luminaire. Contractor shall deposit security on this account @ 5% of work done against these items otherwise the same shall be deducted from the dues payable to him in RAR/Final Bill.
65S&F in repairs Bell, Ding Dong AC. 230 volts, single pole complete all as specified & direct.
66S&F in repairs sheet metal enclouser, single pole and neutral 240 volt, 20 to 32 Amps with two pin and earth plug and socket plug top complete with single pole MCB complete all as specified and directed.
67S&F in repairs sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar 8 way, 240 volts complete all as specified and directed.
68S&F in repairs sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar of 12 way, 240 volts complete all as specified and directed.
69S&F in repairs MCCB 63 Amps, Fixed type 240 volts, 10 KA complete all as specified and directed.
70S&F in repairs MCCB 100 Amps, Fixed type 240 volts, 10 KA complete all as specified and directed.
71S&F in repairs MCB single pole and neutral 63 Amps, 240 volts, C-series complete all as specified and directed.
72S&F in repairs MCB single pole and neutral, 40 Amps, 240 volts, C-series complete all as specified and directed.
73S&F in repairs MCB single pole 06 to 32 Amps, 240 volts, C-series complete all as specified and directed.
74M&L for earthing complete with galvanised steel earth plate electrode, 600mmx600mmx6mm size, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point/MCB DBs all as specified and indicated complete with funnel, charcoal, dust, salt etc and GI protection pipe, medium grade 15mm bore and GI watering pipe 20mm bore light grade, 40mm thick precast RCC M-15 (nomial mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected, complete all as specified & directed. Note:- 1. Earth lead & protection pipes upto & including 7.50 metre length is deemed to be included in the unit rate quoted by the contractor.2. Earth filling should be free from stones, boulders, aggregate, gravels etc
75S&F as in repair sub main wiring with 6.0 sqmm copper conductor cable multistranded, FRLS PVC sheathed two run (as phase and neutral) and one run 6.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity drawn in existing surface /recessed steel/ PVC conduit complete all as specified and directed.
76S&F sub main wiring with 6.0 sqmm copper conductor cable multistrand, FRLS PVC sheathed two run (as phase and neutral) and run 6.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity drawn in & including PVC rigid non metalic concealed conduit 20mm dia with fittings & accessories including cutting chases in walls by using electric cutter and making good the disturbed surface by providing cement plaster & white wash/colour wash to match complete all as specified and directed.
77S&F in repairs modular cover plate with back plate 2 modules on sunken box for fixing of switches and sockets complete all as specified and directed.
78S&F in repairs modular cover plate with back plate 3 modules on sunken box for fixing of switches and sockets complete all as specified and directed.
79S&F in repairs modular cover plate with back plate 4 modules on sunken box for fixing of switches and sockets complete all as specified and directed.
80S&F in repairs modular cover plate with back plate 6 modules on sunken box for fixing of switches and sockets complete all as specified and directed.
81S&F in repairs modular cover plate with back plate 8 modules on sunken box for fixing of switches and sockets complete all as specified and directed.
82Supply only sunken steel box, zinc oxide plated of size 2 module complete all as specified and directed.
83Supply only sunken steel box, zinc oxide plated of size 3 module complete all as specified and directed.
84Supply only sunken steel box, zinc oxide plated of size 4 module complete all as specified and directed.
85Supply only sunken steel box, zinc oxide plated of size 6 module complete all as specified and directed.
86Supply only sunken steel box, zinc oxide plated of size 8 module complete all as specified and directed.
87S&F in repairs bakelite sheet of size 5\\"x5\\" including cutting to required shape for fixing of existing switches and sockets complete all as specified and directed.
88S&F in repairs bakelite sheet of size 8\\"x5\\" including cutting to required shape for fixing of existing switches and sockets complete all as specified and directed.
89S&F in repairs bakelite sheet of size 10\\"x12\\" including cutting to required shape for fixing of existing switches and sockets complete all as specified and directed.
90S&F in repair bakelite sheet of size 8\\"x10\\" including cutting to required shape for fixing of existing switches and sockets complete all as specified and directed.
91S&F as in repairs sunken steel box, zinc oxide plated of size 4''x4'' including cutting the wall to required shape and making good the disturbed surfaces to match existing one complete all as specified and directed.
92S&F as in repairs sunken steel box, zinc oxide plated of size 7''x4'' including cutting the wall to required shape and making good the disturbed surfaces to match existing one complete all as specified and directed.
93S&F as in repairs sunken steel box, zinc oxide plated of size 9''x11'' including cutting the wall to required shape for fixing and making good the disturbed surfaces to match existing one complete all as specified and directed.
94S&F as in repairs sunken steel box, zinc oxide plated of size 7''x9'' including cutting the wall to required shape for fixing and making good the disturbed surfaces to match existing one complete all as specified and directed.
95Supply, install, testing and commissioning in replacement LT busbar chamber box, indoor type,, wall mounted, made out of CRCA sheet 2.00mm thick, CPRI approved, weatherproof, dust and vermin proof, IP-43, powder coated with 8 tank process, sleeve insulated aluminium bus bar 100 Amps, 3 phase, 4 wire 415 volts, single side openable and locking arrangements for compartment grouting on wall necessary PCC work including MCCB of 63Amps, 10KA, 4 pole, 415 volts, 50Hz with fixed magnetic and thermal release complete incl connection from bus bar to meter in meter box with 10sqmm single core wire duly concealed with PVC pipe all as specified and directed.
96Supply, install, testing and commissioning in replacement LT busbar chamber box, indoor type,, wall mounted, made out of CRCA sheet 2.00mm thick, CPRI approved, weatherproof, dust and vermin proof, IP-43, powder coated with 8 tank process, sleeve insulated aluminium bus bar 100Amps, 10 KA, 3 phase, 4 wire 415 volts, single side openable and locking arrangements for compartment grouting on wall necessary PCC work including MCCB of 100 Amps, 10KA 4 pole, 415 volts, 50Hz with fixed magnetic and thermal release complete incl connection from bus bar to meter in meter box with 10sqmm single core wire duly concealed with PVC pipe all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57004826
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 03-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair & Maintenance Of Electric Wiring Alongwith Connected Items In Officers/Jcos/Ors And Otm Accn Of D-I Zone & Ist Horse Area Under Age E/M Of Ge (S) Mamun.
Basic Detail
Tender No GE(S)/M-42/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 20 Aug 2026
Submission Date 03 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
08b1e383-fdcb-4717-b2e3-749721d557ea.html
42TENDERDOCUMENT.pdf
BOQ_878894.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 03, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 10 days
Sep 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

08b1e383-fdcb-4717-b2e3-749721d557ea.html

pdf

42TENDERDOCUMENT.pdf

xls

BOQ_878894.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders