Defence Statutory Bodies & Commissions/Committees Closing in 25 days TDR #57004814

Tender For Addition/Alteration Of Atgg Fuel System, Rig Building No 190 At Gtre, Bangalore

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
1.25 Crore
Estimated cost
Bid Submission
10 Sep 2026
25 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addition/Alteration Of Atgg Fuel System, Rig Building No 190 At Gtre, Bangalore

BOQ

Name of Work:- ADDITION/ALTERATION OF ATGG FUEL SYSTEM, RIG BUILDING NO 190 AT GTRE, BANGALORE
Sl. No. Item Description
1Demolishing cement concrete padding in roof (unreinforced) including removel of existing roof treatment of any descreption and in any position roof not otherwise specially provided for and including removing bedries to a distance exc 5KM but not exc 15 Km outside MD land complete all as specified and directed.
2Material and Labour for cement concrete type B0, 1:2:4 mix ( usisng 12.5mm graded stone aggregate) in padding concrete over roof slab, 30mm to 40mm average thickness up to floor five level, excluding the cost of centering, shuttering complete all as specified and directed.
3Material and Labour for 15mm thick rendering in CM 1:3 over on fair faces of brick work or roof concrete surfaces finishing the surface even and smooth without using extra cement mixed with water proofing compound complete all as specified and directed (WPC will be paid seperatly under relevant items).
4Supply only Liquid water proofing compound (200 ml of LWP C with every 50 kg bag of cement) complete all as specified and directed.
5Providing and applying HS TPO Membrane of 1.2mm thick over the layer of 200 gsm Geo-Textile with overlap joints of 75 mm in both longitudinal and transverse directions of the TPO and sealed properly with hot air welding and terminate TPO at the top of parapet wall with terminatin strip and fix it by screw at 300 mm c/c and sealed with HS Jointseal PU on top including surface preparation like remove all loose gravels, dirt, oil, grease and other foreign particles by jet or dry air and clean the surface mechanically or by grinding to make it smooth before application and PCC / cementitious coving of 75 mm radius shall be provided at all junctions between vertical and horizontal faces before application of TPO compound complete all as specified and directed.
6Demolishing brick work built in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as complete all as specified and directed
7Materials and labour for up to floor five level precast cement concrete solid block masonry , 1:1.5:3 (1 Cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required for centering, shuttering complete all as specified and directed.
8Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed.
9Material & Labour for 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand), finishing complete all as specified and directed.
10Material & Labour for 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand), finishing the surfaces even and smooth w/o using extra cement complete all as specified and directed.
11Material & Labour for 6 mm thick cement plaster mix 1:3 (1 cement: 3 fine sand) finishing the ceiling surface even and smooth without using extra cement complete all as specified
12Providing and fixing false ceiling at any height with 16 mm thick beveled tegular mineral fibre false ceiling tegular edged ceiling tiles 595x595 mm tile (NRC 0.55 to 0.60) of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/ black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using
13galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawings complete all as specified and directed.
14Material and Labour for providing the sealant (pouring grade) in the existing 10mm wide & 40mm deep groove/joint after preparation of joint as per manufacture instructions along with application of primer as per manufacture instructions. (a) Thioflex 600 shall be of M/s FOSROC/ MASTERFLEX TM 700i of BASF or equivalent in CIPY.(b) Primer 7E shall be M/s FOSROC or equivalent in BASF/CIPY. Notes.(a) Application of Epoxy and sealant shall be carried out by authorised applicator of manufacturer.(b) Alternative equivalent make shall be followed as per list of manufacturers
15Material and Labour for heavy duty Epoxy resin based flooring with moisture barrier of total 4mm thick consisting of preparation and removing existing epoxy floor topping by light grinding/shot blasting/wire brushing etc to provide mechanical key to receive floor topping. The prepared surface shall be provided using two component epoxy resign based system Nitoprime 25 of FOSROC or equivalent at 6 sqm/litre in one coat and allowed to dry for 24 hrs. Applying over this primer solvent free 3 part high strength trowel applied screed having mimimum compressive strength of 90 N/sqmm, Tensile strength of 20 N/sqmm and flexural strength of 40N/ sqmm to thickness of 2 mm applied by spreading with towel and finished by proper compaction and allowed to dry to cure for 24 hrs (Nitoflor TS 5000 or Fosroc or equivalent). After curing two component epoxy resign based system (Nitoflor FC140 or equivqlent) putty mixed with quartz filler quartz filler shall be used for the sealing the porous surface of epoxy screed system, Nitoflor TF5000 of Fosroc or equivalent. After this a shop coat of two compotent epoxy resisn based system, Nitoflor FC150 of FOSROC or equivalent shall be applied in two coats at 400 microns covering 10 sqm of 4.5 L pack as top coat. Notes : (a) Applicator of epoxy flooring shall be done with authorised aoolicator of approved manufacturer).(b) Alternative equivalent make shall be followed as per list of manufacturers.
16Note : Application / execution of epoxy flooring shall be done by authorised applicator of approved manufacturer).
17Providing and Fixing modular wall panel 50mm thick, both side PCGI. PCGI filled with PUF quality 40 kg/cum density with 0.6 mm thick sheet. including Aluminum profiles for reinforcement along the periphery and necessary accessories (The materials shall provide excellent sound insulation, resistant to fire, water, and microbial growth, ensuring hygiene etc) complete all as specified and directed.
18Material and labour for High rise modular flooring complete with the following description:- (a) The flooring material shall be of cold rolled steel sheets which are punched spot welded coated with epoxy powder coated , inside of the panel is filled with foamed cement concrete for good mechanical strength, fire reisitant and good sound absoprtion property. The top cover of flooring shall have suitable finishing with Vinyl or Linoleum material finishing (a) Panel of size 600 x 600 mm and thick 30mm. (b) Bottom pedestal plate 100 mm square x 3mm thick. (c) Top pedestal plate 90 mm diameter x 3mm thick with panel locators. (d) Threaded rod assembly to be adjusted upto 450 mm. (e) 50mm long countersunk-head mechnical fastener for all corner fixed ans rigid-grid stringer systems. (f) Pedestal galvanized heavy duty stainless steel leg. (g) glavanised stringers steel with all manufactuer's / company specification and fixtures complete all as specified and directed.
19Material and Labour Modular room Door, PCGI, Skin Thickness: 0.8 mm, Infill : Paper craft Honey comb with flush double glazing glass, hardware like door closure, D handles, ball bearing butt hinges and provision for concealed automatic door bottom seal, (Single door) complete all as specified and directed.
20Material and labour for Vitrified Ceramic, Matt Finish coloured wall tiles of size 1200mm x 600mm x 8 to 10 mm thick on vertical surfaces; set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tile over and including 10 mm thick cement plaster in cement mortar 1:4 complete all as specified and directed.
21Providing and fixing of Ballistic glass (Bullet proof glass level 3) typically made from multiple layers of materials of Polycarbonate: A lightweight, transparent plastic material with high-impact resistance. Laminated Glass to make it more durable, layers shall be strung together with polyvinyl butyral(PVB) or ethylene-vinyl acetate(EVA).Acrylic: A strong, lightweight material to act as a bullet-resistant layer. Glass-Clad Polycarbonate: A hybrid solution combining polycarbonate with laminated glass with maximum strength and clarity and including Vision frame designed for ballistic safety applications complete all as specified and directed.
22Dismantling doors, windows and clerestory windows (steel or wood or any other materials) shutter including chowkats, architrave, holdfasts, guard bars etc. Of area 3 sq. metres and belowc complete and stacking within 50 metres lead complete all as specified and directed.
23Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts, guard bars etc. Of area beyond 3 sq. metres complete and stacking within 50 metres lead complete all as specified and directed.
24Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, complete all as specified and directed (Glazing, paneling and dash fasteners will be paid for separately).
25Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required complete all as specified and directed (Fittings will be paid for separately).
26Providing and fixing 12 mm thick Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P . brass / stainless steel screws etc. complete all as specified and directed.
27Providing and fixing with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete all as specified and directed (Cost of aluminium snap beading shall be paid in basic item).
28Supply and fixing for Aluminium Door Floor Spring suitable for door shutters of 800 to 1200 mm in width and of weight between 80 to 100 kg and fixed complete all as specified and directed.
29Supply and fixing for 2 Levers Aluminium Mortice lock, vertical type, size 100 mm fixed to aluminum door shutter complete all as specified and directed.
30Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size complete all as specified and directed.
31Providing and fixing for 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements complete all as specified and directed. to take up necessary hardware and fixtures. Stickers indicating the locations of hardware shall be pasted at appropriate places
32Supply and fixing for 100mm Butt hinges, medium weight cold rolled mild steel, and fixed complete all as specified and directed.
33Supply and fixing for 200mm Length, Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
34Supply and fixing for 150mm Aluminium handles, cast type, anodised complete all as specified and directed.
35Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance on New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.dirt resistance exterior paint of required shade with silicon additives complete all as specified and directed.
36Material & Labour for Distempering with 1st quality Acrylic distemper or Oil bound Distemper for walls and ceiling (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :New work (two or more coats) including Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre complete all as specified and directed.
37Complete removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. Providing and applying wall putty of 2 mm thickness over plastered surface to prepare the surface even and smooth and applying Distempering with 1st quality two coats acrylic Oil bond distember on old work (Old prepared surface) (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour to give an even shade and colour complete. complete all as specified and directed.
38Removing dry or oil bound distemper /Exterior paint/Cement base paint, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc and Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance on Old work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.dirt resistance exterior paint of required shade with silicon additives complete all as specified and directed.
39Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats complete all as specified and directed.
40Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and directed.
41Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet complete all as specified and directed.
42Providing and fixing galvalume profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed.
43Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and directed.
44Painting with synthetic enamel paint to New steel surfaces and two or more coats on new work of approved brand and manufacture to give an even shade complete all as specified and directed.
45Material and labour for French spirit polishing One or more coats on old wooden surfaces complete all as specified and directed.
46M&L for prepartion of old painted steel surfaces and applying one coat of synthetic enamel paint of any description not otherwise described over 10cm width or girth complete all as specified and directed (height Upto 15 Mtr including all necessary scaffolding).
47Dismantling of Terrazo floor tile work for thickness of tiles 10 mm to 25 mm in floors and roofs laid in cement mortar including stacking material within 50 metres lead complete all as specified and directed.
48M&L 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in bedding, finished fair and even complete all as specified and directed
49Providing and laying Double charged vitrified tile Polished /Matt Finish coloured of 600x600 mm size in floor in different sizes ( 8 to 10 mm thickness ) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles shall be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed.
50Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level complete all as specified and directed.
51Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed (Capcity 1000 Ltrs).
52Providing and fixing for 20 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete all as specified and directed.
53Providing and fixing for 20 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end) complete all as specified and directed.
54Providing and fixing 20 mm nominal dia Pipes, Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and Concealed work, including cutting chases and making good the walls etc including Dismantling 15 to 40 mm dia G.I. pipe internal connection inlet and outlet connections including stacking of dismantled pipes (within 50 metres lead) complete all as specified and directed.
55Providing and fixing 25 mm nominal dia Pipes, Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching and External work, refilling & testing of joints including Dismantling old 15 to 40 mm dia G.I. pipe internal connection inlet and outlet connections including stacking of dismantled pipes (within 50 metres lead) complete all as specified and directed.
56S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including aking down old rain water pipes (any size or pattern) including all fittings bends etc complete all as specified and directed.
57S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
58S&F 110mm bore PVC (SWR) couplers complete all as specified and directed.
59Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains for all kind of soil (not exceeding 1.5 m in width or 10 sqm on plan), including and dressing of sides and ramming of bottom, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. complete all as specified and directed.
60Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) complete all as specified and directed.
61Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, flooring, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing complete all as specified and directed.
62Material & Labour for Nozzle fixing– for epoxy: Packer drilling, installation and finishing Drilling and fixing injection packers in RCC members including, drilling holes in structural members at the intervals complete all as specified and directed. Cleaning of holes: Cleaning the holes shall be done by vaccum cleaner prior to fixing nozzles.
63Supply and apply a shrinkage free low viscous epoxy resin based injection grout.Product: Dr. Fixit epoxy injection grout/ Sikadur®-55 LP IN. Yield: 0.88 ltr/kg Product requirements: Compressive strength >= 70 N/mm2 (7 days) according to BS 6319:PART 2; Flexural strength > 30 N/mm2 (7 days) according to BS 6319:PART 3; Tensile strength > 15 N/mm2 (7 days) according to BS 6319:PART 7; Bond strength > 10 N/mm2 (14 days) or concrete failure according to ASTM D 4541 complete all as specified and directed.
64Taking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as specified and directed.
65Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. complete all as specified and directed.
66(a) One Light point/wall fan/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
67Wiring for twin control light point with 1.5 sqmm FRLSH PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit , 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLSH PVC insulated copper conductor single core cable etc. complete all as specified and directed.
68(a) One light point controlled by two way switch
69Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including Taking down exiting copper/aluminium sub main wiring complete and making good disturbed surfaces of walls, floors, etc complete complete incuding all as specified and directed.
702 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
712 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
722 X 4 sq. mm + 1 X 4 sq. mm earth wire.
732 X 6 sq. mm + 1 X 6 sq. mm earth wireNote for item No 65.01 to 65.04. 2 runs of sub main wire and 1 run of earthing wire including 1 run of conduit shall be measured as one unit.
744 X 10 sq. mm + 2 X 10 sq. mm earth wireNote. 4 runs of sub main wire and 2 run of earthing wire including 1 run of conduit shall be measured as one unit.
75Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Amps modular socket outlet and 5/6 A modular switch, connections etc complete all as specified and directed.
76Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and 15/16 Amps modular socket outlet and 15/16 A modular switch, connections etc complete all as specified and directed.
77Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. complete all as specified and directed.
78Supply & fix ceiling rose surface backelite two to three terminal complete all as specified and directed.
79Supply & fix fan step regulator 120watt, 2 module complete all as specified and directed.
80Dismantling and refixing the ceiling fan complete of any type and size after cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor and spray painting complete all as specified and directed.Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted.
81Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper windding from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling,greasing to bearing, replacing bushes, replacement of capacitor and testing complete all as specified and directed.Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan shall be deemed to include in the rate quoted.(b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and for from site to work place are deemed to be included in rate quoted. Please Enable Macros to View BoQ information
82Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper windding from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials , varnishing, reassembling,greasing to bearing, replacing bushes, replacement of capacitor and testing complete all as specified and directed.Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan shall be deemed to include in the rate quoted.(b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and for from site to work place are deemed to be included in rate quoted. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57004814
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.25 Crore
LAST DATE 10-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addition/Alteration Of Atgg Fuel System, Rig Building No 190 At Gtre, Bangalore
Basic Detail
Tender No 82680
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 13 Aug 2026
Submission Date 10 Sep 2026
Open Date 14 Sep 2026
Finance
Tender Value 1.25 Crore
Tender Fee 1000
EMD 2 Lakhs
Exemption Available
Document List
BOQ_878765.xls
f8b6a844-a3d8-4360-bc45-7b3fa84d49aa.html
Tendernotice_1.pdf
82680Tender.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Sep 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.