Tender For Provn Of Ration Store Shelter Near Bldg No T-47 For 8 Mahar At Kil Rear & Special Repair To Lt Panels Lt Ug Cables Alongwith Connected Items At Various Location Of Drass Under Ge Kargil
Tender Value
32.95 Lakhs
Estimated cost
Bid Submission
03 Sep 2026
4 days left
EMD
66000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kargil → Jammu And Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Ration Store Shelter Near Bldg No T-47 For 8 Mahar At Kil Rear & Special Repair To Lt Panels Lt Ug Cables Alongwith Connected Items At Various Location Of Drass Under Ge Kargil
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing n.exc 15cm deep and getting out hard/dense soil complete all as specified and directed by the Engg-in-Charge. |
| 2 | M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted bulit in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 3 | Excavating in trenches in Hard and dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sq mtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and directed by the Engr-in-Charge. |
| 4 | M&L for PCC type B2 1:2:4 (using 40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed by the Engg-in-Charge. |
| 5 | M&L 75mm thick PCC (1:3:6) type C2 as in sub base to floor or similar works complete all as specified and directed by the Engg-in-Charge. |
| 6 | S&F Rolled mild steel Gde Fe-290 (Gde Fe 165) as in Roof trusses (framed), trussed, purlins crane gantries, rails & fastenings & heavy brackets framimg (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed by the Engg-in-Charge. |
| 7 | S&F Rolled mild steel Gde Fe-290(Gde Fe 165) in Plates (plain or chequered) channels,angle sections, square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed by the Engg-in-Charge. |
| 8 | S&F Mild steel rag or lewis bolts screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised length of bolt exc 15 cm and not exc 30 cm long and neck diameter 12mm complete all as specified and directed by the Engg-in-Charge. |
| 9 | M&L for preparation of newly untreated steel / iron surfaces of any description over 10cm in width or girth not otherwise described and painting two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed by the Engg-in-Charge. |
| 10 | M&L for Precast cement concrete Type C1 (1:3:6) (using 20mm graded crushed stone agg) block masonary with solid blocks exc 10cm in width and setting in CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 11 | S&F plain solid straight chowkats and framed wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints in 2nd class hardwood complete all as specified and directed by the Engg-in-Charge. |
| 12 | M&L for 15mm thick cement plaster on other than fair faces concrete surface in CM (1:4) finished even and somooth without using extra cement complete all as specified and directed by the Engg-in-Charge. |
| 13 | M&L 15mm thick cement plaster on fair faces of concrete surface in cement mortar (1:6) finished even and somooth without using extra cement complete all as specified and directed by the Engg-in-Charge. |
| 14 | M&L for preparation of new plastered surfaces on walls and applying three coats of white washing complete all as specified and directed by the Engg-in-Charge. |
| 15 | M&L for preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed by the Engg-in-Charge. |
| 16 | Returning, filling of hard / dense soil incl spreading, levlling, watering and well ramming in each layer n.exc 25 cm thick complete all as specified and directed by the Engg-in-Charge. |
| 17 | Earth filling in floors or paving including spreding, levelling and ramming with watering as required in layers n.exc 25cm thick complete all as specified and directed by the Engg-in-Charge. |
| 18 | M&L for broken stone or boulders as in hardcore of gauge not exc 63mm deposited, spread and levelled in layers not exc 15cm thick watered and rammed to a true surface complete all as specified and directed by the Engg-in-Charge. |
| 19 | M&L for 25mm thick PCC type B0 (12.5mm graded stone aggregate) 1:2:4 as in Floor or similar works complete all as specified and directed by the Engg-in-Charge. |
| 20 | M&L for 75mm thick PCC type C-2 1:3:6 as in plinth protection/ sub base or similar works complete all as specified and directed by the Engg-in-Charge. |
| 21 | S&F 0.63mm thick, galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with self tapping screw or L-type or J-type or crancked hook bolts and washers as in roofs, walls etc, with grade of zinc coating 275 complete all as specified and directed by the Engg-in-Charge. |
| 22 | S&F for 0.63 mm thick, plain galvanised, mild steel sheeting in ridges, hips, valley gutters, drip and straight flashing (length and girth as fixed with grade of zink coating 275, complete all as specified and directed. |
| 23 | S&F 30mm thick 2nd class hard wood plain framed panelled shutter (any number of panels) with panels of timber flat on both sides (Feather edge) or of veneered particle board medium density wood particle board with commercial face veneers and fitted to chowkhat complete all as specified and directed by the Engg-in-Charge. |
| 24 | S&F 30mm 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by the Engg-in-Charge. |
| 25 | M&L for preparation of new wooden surfaces of any dscription over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by the Engg-in-Charge. |
| 26 | S&F 100mm but hinges medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed by the Engg-in-Charge. |
| 27 | S&F Aluminium alloy, anodized, sliding door bolt with hasp staple (bolt type) & fixing clips of shet, cast or extrucded section & fixing bolts & sliding bolts of extrucded section or cast alluminium alloy & fixed 300mm long complete all as specified and directed by the Engg-in-Charge. |
| 28 | S&F 150mm long alluminium anodized, barrel tower bolts exturded section & fixed complete all as specified and directed by the Engg-in-Charge. |
| 29 | S&F aluminium handles cast type anodised size150mm complete all as specified and directed by the Engg-in-Charge. |
| 30 | S&F 75mm butt higes medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed by the Engg-in-Charge. |
| 31 | S& F 100mm long alluminium anodized, barrel tower bots exturded section & fixed complete all as specified and directed by the Engg-in-Charge. |
| 32 | S& F aluminium handles cast type anodised size100mm complete all as specified and directed by the Engg-in-Charge. |
| 33 | S&F figured galss 4mm thckness pin headed type and glazing with oil putty n exc 0.5 Sqm in each pane complete all as specified and directed by the Engg-in-Charge. |
| 34 | S&F in repairs 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails on ceiling to timber frame work complete all as specified and directed by the Engg-in-Charge. |
| 35 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 13sqcm but not exceeding 25sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by the Engg-in-Charge. |
| 36 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer point controlled by one switch. |
| 37 | All as per Srl item No 36 here in before but using cable size 1.5 Sqmm for one 3 pin socket outlet 5 Amps independent board complete all as specified and directed by the Engg-in-Charge. |
| 38 | All as per Srl item No 36 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board complete all as specified and directed by the Engg-in-Charge. |
| 39 | S&F Switch piano flush type 5 Amps, single pole one way complete all as specified and directed by the Engg-in-Charge. |
| 40 | S&F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type complete all as specified and directed by the Engg-in-Charge. |
| 41 | S&F Switch socket combination 2 in 1,3 pin, 5 and 15 Amps flush type complete all as specified and directed by the Engg-in-Charge. |
| 42 | S&F Ceiling rose on PVC Square Block surface bakelite 65x50mm, two to three terminals complete all as specified and directed by the Engg-in-Charge. |
| 43 | S&F LED white colour 1x18 Watt, 220 V, AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by the Engg-in-Charge. |
| 44 | S&f Lamp holder PVC/Polycarbonate type on square block with back plate suitable for batten fittings complete all as specified and directed by the Engg-in-Charge. |
| 45 | S&F LED bulb 09 watt, 230 volts complete all as specified and directed by the Engg-in-Charge. |
| 46 | S&F Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by the Engg-in-Charge. |
| 47 | S&F 240V, 10 KA C curve MCB SPN 40 to 63Amp in the existing MCB DB complete all as specified and directed by the Engg-in-Charge. |
| 48 | S&F 240 V 10 KA C curve MCB SP 5 to 32Amp in the existing MCB DB complete all as specified and directed by the Engg-in-Charge. |
| 49 | S&F LED light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up three core flexible copper conductor cable of suitable size complete all as specified and directed by the Engg-in-Charge. |
| 50 | S&F LED Flood light fitting 70watt 5000 k green/natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories complete all as specified and directed by the Engg-in-Charge. |
| 51 | S&F exhaust fan made of sturdy Engineering plastic complete, AC single phase, 230 V of size 250mm sweep with blades and frame and louvers complete with cutting of suitable size of hole on wall with all connected accessories and making surface good after fixing complete all as specified and directed by the Engg-in-Charge. |
| 52 | S&F 1100 volts grade heavy duty 16sqmm 2core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended with suitable size of PVC conduit and saddle for whole length to fix on wall/surface complete all as specified and directed by the Engg-in-Charge. |
| 53 | M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI iron wire of size 4 mm dia by means of GI bolts, nuts, check nuts and washers, protected by 15mm bore GI light grade ISI marked pipe upto and including test points. Earth plate shall be surrounded by alternate layer 15cm thick of charcoal or coke and common salt all around bottom and top , 20cm bore GI medium grade ISI marked pipe for watering and including funnel,wire mesh,PCC chamber pit made with PCC(1:3:6) type C-1(using 20mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50M, CI pit cover duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No.3 of SSR 2009(Part-I) and all as directed.Note:- (i) Protection pipe and earthing strip upto test point from top of the earth plate and further upto the body of electrical equipment shall be included in the unit rate of this item.(ii) Earth testing arrangement should be done by contractor as per direction of Engr-In-Charge. |
| 54 | M&L in replacement of LT UG cable 2corex16sqmm 1100 Volts grade XLPE insulated, armoured, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable gland lugs/ thimbles/ ferrules including connecting, testing and commissioning complete for the following sizes including taking down existing LT UG cable of any size at site all as specified and directed by the Engr-in-Charge. Notes:-(a) Excavation ,RFR, and protection pipe etc. Shall be measured and paid separately under relevant item of schedule (b) Rate quoted deemed to include for cutting and removing of defective joints where required as directed. |
| 55 | All as per item No 54 but size 2core 10Sqmm as specified and directed by the Engr-in-Charge. |
| 56 | All as per item No 54 but size 4 core 25Sqmm as specified and directed by the Engr-in-Charge. |
| 57 | All as per item No 54 but size 3.5 core 35Sqmm as specified and directed by the Engr-in-Charge. |
| 58 | All as per item No 54 but size 3.5 core 50Sqmm as specified and directed by the Engr-in-Charge. |
| 59 | All as per item No 54 but size 3.5 core 70Sqmm as specified and directed by the Engr-in-Charge. |
| 60 | All as per item No 54 but size 3.5 core 95Sqmm as specified and directed by the Engr-in-Charge. |
| 61 | All as per item No 54 but size 3.5 core 120Sqmm as specified and directed by the Engr-in-Charge. |
| 62 | Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engr-in-Charge |
| 63 | S&F in replacement of GI tubing light grade 40mm bore as in cable protection fixed to poles/walls or laid in trenches/under road crossing etc. all as specified and as directed by the Engr-in-Charge. |
| 64 | S&F in replacement of GI tubing light grade 80mm bore as in cable protection fixed to poles/walls or laid in trenches/under road crossing etc. all as specified and as directed by the Engr-in-Charge. |
| 65 | Supplying and laying in replacement of un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250x150x40mm laid dry over electric cable for protection complete all as specified and directed by the Engr-in-Charge |
| 66 | S&F in replacement of LT Cable joining kit outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for LT Armoured cables of size 50 Sqmm 3.5 core complete all as specified and directed by the Engr-in-Charge. |
| 67 | S&F in replacement of LT Cable joining kit outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for LT Armoured cables of size 70-120Sqmm 3.5 core complete all as specified and directed by the Engr-in-Charge. |
| 68 | S&F in replacement of LT straight through Cable joining kit, heat shrinkable suitable for LT Armoured cables of size 25-50Sqmm 3.5core complete all as specified and directed by the Engr-in-Charge. |
| 69 | S&F in replacement of LT straight through Cable joining kit suitable for LT Armoured cables of size 70-95Sqmm 3.5core complete all as specified and directed by the Engr-in-Charge. |
| 70 | Supply, installing, testing and commissioning in replacement of factory made LT panel ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled ,Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 400 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 mmX 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 71 | BUS BAR CHAMBER :- (a) 400 Amps 4 Strips Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 250 Amps 36 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No.(ii) On Load Change Over Switch 250 Amps 4 Pole 415 Volts Open Execution panel mounted with operating handle=01 Nos.INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current(0-250A) , P.F , etc including necessary suitable P.T & C.Ts - 1 Set(b) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(c) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 72 | OUTGOING SUPPLY :- (i) MCCB 160 Amps 25 KA 4 pole,415 volts , 50Hz - 01 Nos, (ii) MCCB 100 Amps 25 KA 4 pole,415 volts , 50Hz - 01 Nos, (iii) MCCB 63 Amps 16 KA 4 pole,415 volts , 50Hz - 02 Nos, (iv) MCB 32 Amps, 10 KA, SPN 230 Volts, 50Hz - 02 Nos, |
| 73 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 400 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40mm X 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 74 | BUS BAR CHAMBER :- (a) 400 Amps 3 Strips & Netural, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 250 Amps 36 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No., INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current (0-250 A) , P.F , etc including necessary P.T & C.Ts - 1 Set(b) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(c) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 75 | OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA 4 Pole Adjustable release 415 volts , 50Hz - 02 Nos, (ii) MCB 63 Amps 10 KA, TPN 415 Volts , 50Hz - 01 Nos, (iii) MCB 40 Amps 10 KA, SPN 230 Volts, 50Hz -02 Nos, |
| 76 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 400 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 mmX 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 77 | BUS BAR CHAMBER :- (a) 400 Amps 4 Strips Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 250 Amps 36 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No.(ii) On Load Change Over Switch 250 Amps 4 Pole 415 Volts Open Execution panel mounted with operating handle=01 Nos.INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current (0-250A) , P.F , etc including necessary P.T & C.Ts - 1 Set(b) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(c) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 78 | OUTGOING SUPPLY :- (i) MCCB 160 Amps 25 KA 4 pole,415 volts , 50Hz - 01 Nos, (ii) MCCB 100 Amps 25 KA 4 pole,415 volts , 50Hz - 01 Nos, (iii) MCCB 63 Amps 16 KA 4 pole,415 volts , 50Hz - 02 Nos, (iv) MCB 32 Amps, 10 KA, SPN 230 Volts, 50Hz - 02 Nos, |
| 79 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 200 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 mmX 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 80 | BUS BAR CHAMBER :- (a) 200 Amps 4 Strips Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 125 Amps 25 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No., INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current (0-200A) , P.F , etc including necessary P.T & C.Ts - 1 Set (b) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)(c) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(d) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 81 | OUTGOING SUPPLY :- (i) MCB 63 Amps 10 KA, TPN 415 Volts , 50Hz - 02 Nos, (ii) MCB 40 Amps 10 KA, SPN 230 Volts, 50Hz -01 Nos,(iii) MCB 32 Amps 10 KA, SPN 230 Volts, 50Hz -01 Nos, |
| 82 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 200 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 mmX 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 83 | BUS BAR CHAMBER :- (a) 200 Amps 4 Strips Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 125 Amps 25 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No.,INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current (0-200A), P.F , etc including necessary P.T & C.Ts - 1 Set(b) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(c) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 84 | OUTGOING SUPPLY :- (i) MCB 63 Amps 10 KA, TPN 415 Volts , 50Hz - 02 Nos (ii) MCB 40 Amps 10 KA, SPN 415 Volts , 50Hz - 01 Nos, (iii) MCB 32 Amps 10 KA, SPN 230 Volts, 50Hz -01 Nos, |
| 85 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 300 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40mm X 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 86 | BUS BAR CHAMBER :- (a) 300 Amps 3 Strips & Netural, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 200 Amps 36 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No., INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current (0-250A) , P.F , etc including necessary P.T & C.Ts - 1 Set(b) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(c) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 87 | OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA 4 Pole Adjustable release 415 volts , 50Hz - 02 Nos, (ii) MCB 63 Amps 10 KA, TPN 415 Volts , 50Hz - 01 Nos, (iii) MCB 40 Amps 10 KA, SPN 230 Volts, 50Hz -02 Nos, |
| 88 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 300 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40mm X 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 89 | BUS BAR CHAMBER :- (a) 300 Amps 4 Strips Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 200 Amps 36 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No.INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current(0-200A) , P.F , etc including necessary P.T & C.Ts - 1 Set(b) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(c) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 90 | OUTGOING SUPPLY :- (i) MCCB 63 Amps 10 KA 4 pole,415 volts , 50Hz - 05 Nos, (ii) MCB 63 Amps 10 KA, SPN 230 Volts, 50Hz -01 Nos, |
| 91 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 400 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40mm X 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 92 | BUS BAR CHAMBER :- (a) 400 Amps 4 Strips Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 250 Amps 36 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No.(ii) On Load Change Over Switch 250 Amps 4 Pole 415 Volts Open Execution panel mounted with operating handle=01 Nos.INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current (0-250A) , P.F , etc including necessary P.T & C.Ts - 1 Set(b) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(c) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 93 | OUTGOING SUPPLY :- (i) MCCB 160 Amps 25 KA 4 Pole Adjustable release 415 volts , 50Hz - 01 Nos, (ii) MCCB 63 Amps 10 KA, 4 Pole 415 Volts , 50Hz - 02 Nos, (iii) MCB 63 Amps 10 KA, SPN 230 Volts, 50Hz -03 Nos, |
| 94 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled LT Panel Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 300 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40mm X 40mm X 5 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including block of PCC 1:2:4 type B1 of block size 30cmx30cmx30 cm comprising of the following:- (Make of Panel :-L&T/ UNIVERSAL SWITCH GEAR CONTROL/SIEMENS/SCHENIDER)Note:- Drawing of LT Panel shall be submitted before fabrication of panel and same shall be approved by GE. |
| 95 | BUS BAR CHAMBER :- (a) 300 Amps 3 Strips & Netural, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INCOMING SUPPLY :- (i) MCCB 200 Amps 36 KA 4 Pole with Adjustable release 415 volts , 50Hz,=01 No.,INSTRUMENT FEEDER :- (a) Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current (0-200A) , P.F , etc including necessary P.T & C.Ts - 1 Set(b) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(c) Protection MCB 6 A SP C Series- 1 Set. (Set of three). |
| 96 | OUTGOING SUPPLY :- (i) MCCB 160 Amps 25 KA 4 Pole Adjustable release 415 volts , 50Hz - 01 Nos, (ii) MCCB 63 Amps 10 KA, 4 Pole 415 Volts , 50Hz - 02 Nos, (iii) MCB 63 Amps 10 KA, SPN 230 Volts, 50Hz -02 Nos, |
| 97 | S&F as in repairs MCCB, 400A, rupturing capacity 36 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 98 | S&F as in repairs MCCB, 400A, rupturing capacity 36 KA, 415 volts 3 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 99 | S&F as in repairs MCCB, 250A, rupturing capacity 36 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 100 | S&F as in repairs MCCB, 250A, rupturing capacity 36 KA, 415 volts 3 pole fixed adjustable complete all as specified and directed by the Engr-in-Charge |
| 101 | S&F as in repairs MCCB, 200A, rupturing capacity 36 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 102 | S&F as in repairs MCCB, 200A, rupturing capacity 36 KA, 415 volts 3 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 103 | S&F as in repairs MCCB, 160A, rupturing capacity 25 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 104 | S&F as in repairs MCCB, 160A, rupturing capacity 36 KA, 415 volts 3 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 105 | S&F as in repairs MCCB, 125A, rupturing capacity 25 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 106 | S&F as in repairs MCCB, 125A, rupturing capacity 16 KA, 415 volts 3 pole fixed type complete all as specified and directed by the Engr-in-Charge |
| 107 | S&F as in repairs MCCB, 100A, rupturing capacity 25 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge |
| 108 | S&F as in repairs MCCB, 100A, rupturing capacity 16 KA, 415 volts 3 pole fixed type complete all as specified and directed by the Engr-in-Charge |
| 109 | S&F as in repairs MCCB, 63A, rupturing capacity 10 KA, 415 volts 4 pole adjustable type complete all as specified and directed by the Engr-in-Charge. |
| 110 | S&F in repair 415V 10KA 'C' curve MCB TPN of 40 to 100 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by the Engr-in-Charge. |
| 111 | M&L in replacment of ON LOAD change over switch with sheet metal enclosure 415V, 4 pole of capacity 400 Amps fixed on wall/angle including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 112 | S&F in repair of ON LOAD change over switch with sheet metal enclosure, 415V, 4 pole of capacity 320 Amps fixed on wall/angle including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 113 | S&F in repair of ON LOAD change over switch with sheet metal enclosure, 415V, 4 pole of capacity 250 Amps fixed on wall/angle including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 114 | S&F in repair of ON LOAD change over switch with sheet metal enclosure, 415V, 4 pole of capacity 160 Amps fixed on wall/angle including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 115 | S&F in repair of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 100 Amps fixed on wall/angle including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 116 | S&F in repair of ON LOAD change over switch with sheet metal enclosure, 415V, 4 pole of capacity 63 Amps fixed on wall/angle including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and directed by the Engr-in-Charge. |
| 117 | S&F in repair 240V 10 KA C curve MCB SPN 40 to 63Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by the Engr-in-Charge. |
| 118 | M&L for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip 32×6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. GI Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :-(a) GI strip 32x6 mm.(b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (MS Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. |
| 119 | S&F in repair 3phase Busbar chamber,wall mounted type, 200A, 4 way, busbar made of ETP grade copper fixed on wall/angle complete all as specified and directed. Make- Havells/Equivalent in L&T/Legrand |
| 120 | S&F in repair 3phase Busbar chamber,wall mounted type, 200A, 8 way, busbar made of ETP grade copper fixed on wall/angle complete all as specified and directed. Make- Havells/Equivalent in L&T/Legrand |
| 121 | Note : Deduction for amount of Rs. 75668.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender