Tender For Addition/Alteration Of Main Security Gate Office And Augmentation Of Security Main Gate At Hemrl, Under Ge (I) R&D Pashan, Pune
Tender Value
1.54 Crore
Estimated cost
Bid Submission
10 Sep 2026
18 days left
EMD
2.29 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition/Alteration Of Main Security Gate Office And Augmentation Of Security Main Gate At Hemrl, Under Ge (I) R&D Pashan, Pune
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors and wall laid in cement mortar including stacking material within 50 metres lead for any type of tiles, thickness of tiles 10 mm to 25 mm complete all as specified and directed. |
| 2 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc, including dismembering and stacking within 50 metres lead complete all as specified and directed. |
| 3 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead complete all as specified and directed. |
| 4 | Demolishing brick work manually/ by mechanical means, In cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as complete all as specified and directed. |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead complete all as specified and directed. |
| 6 | Dismantling roofing GI sheet / Asbestos sheet including ridges, hips, valleys and gutters etc, and stacking the material within 50 metres lead complete all as specified and directed. |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), in all kinds of soil, including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil, within a lead of 50m complete all as specified and directed. |
| 8 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), in Ordinary Rock including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated rock and disposal of excavated rock, within a lead of 50 m complete all as specified and directed. |
| 9 | Providing and laying PCC 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA) complete all as specified and directed. |
| 10 | Material and labour for Random rubble masonry in CM 1:6 with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level complete all as specified and directed. |
| 11 | Material and labour for Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand), Flush/ Ruled pointing complete all as specified and directed. |
| 12 | Material and labour for Filling excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m complete all as specified and directed. |
| 13 | Providing and laying in position cement concrete, 40mm thick of specified grade excluding the cost of centering and shuttering, All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) including, manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%) complete all as specified and directed. |
| 14 | Material and labour for Hardcore of gauge n exc. 63 mm, including earth filling, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 15 | Providing and laying vitrified floor tiles of size 600 x 600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc complete all as specified and directed. |
| 16 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc, Complete all as specified and as directed by Engr-in-Charge. |
| 17 | Providing and laying factory made Precast concrete solid blocks exceeding 10mm width of grade M10 made of C&D waste from approved manufacturer in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed. |
| 18 | Material and labour for 15 mm cement plaster of mix 1:4 (1 cement : 4 fine sand) on rough faces of brick or concrete surfaces complete all as specified and directed. |
| 19 | Material and labour for Finishing new walls with two coats of acrylic smooth exterior paint of required shade, applied @ 1.67ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9l/10 sqm complete all as specified and directed. |
| 20 | Material and labour for 15mm thick rendering in cm (1:6) on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete all as specified and directed. |
| 22 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade as in New work (two coats) over and including water thinnable priming coat with cement primer complete all as specified and directed. |
| 23 | Material and labour for Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture complete all as specified and directed. |
| 24 | Providing and fixing aluminium frame work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately), Powder coated aluminium (minimum thickness of powder coating 50 micron) complete all as specified and directed. |
| 25 | Providing and fixing aluminium work for doors, windows, ventilators and partitions For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Powder coated aluminium (minimum thickness of powder coating 50 micron) complete all as specified and directed. |
| 26 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) complete all as specified and directed. |
| 27 | Providing and fixing for Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 28 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc, With stainless steel cover plate minimum 1.25 mm thickness complete all as specified and directed. |
| 29 | Material and labour for louvered ventilators of section size 100mm x 25mm x1.5mm including frosted glass fixed in half portion & adjustable type louvers in another half and stainless steel wire mesh fixed type on outside frame including taking down existing steel ventilator complete all as specified and directed. |
| 30 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings, upto 5mm depth and 5 mm width complete all as specified and directed. |
| 31 | Material and labour for Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and directed. |
| 32 | Providing and fixing bolts including nuts and washers complete all as specified and directed. |
| 33 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes of 110 mm dia meter complete all as specified and directed. |
| 34 | Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, gutter, fixed with self tapping screws complete all as specified and directed.Note: Steel profile as directed by GE |
| 35 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. |
| 36 | Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit, complete all as specified and directed. |
| 37 | Providing and fixing 1st quality ceramic Antiskid floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 38 | Providing and laying Glazed wall tiles /Antiskid finish of Size of Tile 600 x 300 mm in dado in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 39 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion), Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration, complete all as specified and directed. |
| 40 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration complete all as specified and directed. |
| 41 | Dismantling doors, windows and clerestory windows (steel or wood) shutter of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead complete all as specified and directed. |
| 42 | Providing and fixing factory made panel PVC door shutter, 30 mm thick consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc, complete all as specified and directed. |
| 43 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size complete all as specified and directed. |
| 44 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc, complete 100 x 58 x1.90 mm complete all as specified and directed. |
| 45 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc, complete 300 x16 mm, Complete all as specified and as directed by Engr-in-Charge. |
| 46 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed, to required colour or shade, with necessary screws etc, complete 200 x10 mm complete all as specified and directed. |
| 47 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc, complete 125 mm complete all as specified and directed. |
| 48 | Providing and fixing 1mm thick M.S. sheet door with frame of 40 x 40 x 6mm, angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer, using M.S. angels 40x40x6 mm for diagonal braces, complete all as specified and directed. |
| 49 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. andDistempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour, For old surfaces, including Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete all as specified and directed. |
| 50 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. and Material and labour for Finishing walls with Acrylic Smooth exterior paint of required shade Old work (Two coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface complete all as specified and directed. |
| 51 | Dismantling of ACP Cladding and builtup sections upto a lead of 50m complete all as specified and directed. |
| 52 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design, Cladding Work:-(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick), The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and |
| 53 | shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item, The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 54 | Providing and fixing in repairs G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 15 mm dia nominal bore complete all as specified and directed. |
| 55 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms 15 mm nominal bore complete all as specified and directed. |
| 56 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 15 mm nominal bore complete all as specified and directed. |
| 57 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests complete all as specified and directed. |
| 58 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid complete all as specified and directed. |
| 59 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality complete all as specified and directed. |
| 60 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps complete all as specified and directed. |
| 61 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern complete all as specified and directed. |
| 62 | Providing and fixing Venetian blinds with design in inner face, vertical type made of fibre cloth fixed to wall with necessary aluminium brackets, screws etc incl aluminium frame ropes, rollers etc, complete all as specified and directed. |
| 63 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc) complete all as specified and directed. |
| 64 | Material and labour for preparation of old painted wooden surfaces of any description Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two coats on existing surface complete all as specified and directed. |
| 65 | Material and labour for preparation of old painted steel surfaces of any description, Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade complete all as specified and directed. |
| 66 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc, and Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade, old plastered surface as in ceiling (two or more coats) over and including water thinnable priming coat with cement primer complete all as specified and directed. |
| 67 | Material and labour Stone tile (polished) work 8mm thick Granite colour and shade matching to existing color of granite for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete all as specified and directed. |
| 68 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame Rectangular shape 453x357 mm of approved make and shade with 6 mm thick hard board backing complete all as specified and directed. |
| 69 | Material and labour Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles,Medium shade pigment using 50% white cement 50% Grey cement. including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) complete all as specified and directed. |
| 70 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side complete all as specified and directed. |
| 71 | Surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, All kinds of soil complete all as specified and directed. |
| 72 | Material and labour for Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489: 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two coats applied @ 1.43 litre/ 10 sqm. Over and including priming one coat of exterior primer applied @ 0.90 litre/10 sqm complete all as specified and directed. |
| 73 | Material and Labour for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 applying a priming coat of approved steel primer complete all as specified and directed. |
| 74 | S&F for 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges complete all as specified and directed. |
| 75 | Material and labour for Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, Painting Steel work with Deluxe Multi Surface Paint to give an even shade, Two coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture complete all as specified and directed. |
| 76 | Material and labour for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 77 | Material and labour for Hardcore of guage exc 63mm but n exc.100 mm, including earth filling to gaps, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 78 | Material and labour for for Cement concrete type D-2, 1:4:8 (40mm graded aggregate) 100 mm thick as in sub base complete all as specified and directed. |
| 79 | Material and labour for Cement concrete type B -1, 1:2:4 (20mm graded aggregate) 100 mm thick as in hardstanding complete all as specified and directed. |
| 80 | Providing and laying Forming 20 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified and directed. |
| 81 | Providing and laying in position cement concrete as in coping, PCC for post etc of specified grade including the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 25%) complete all as specified and directed. |
| 82 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, sewage line etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and directed. |
| 83 | M&L for Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in foundations, filling and mass concrete, sub base etc complete all as specified and directed. |
| 84 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Old size bricks in cement mortar 1:6 complete all as specified and directed. |
| 85 | Material and labour for Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level, Thermo-Mechanically Treated bars 10mm and over of grade Fe-500D or more complete all as specified and directed. |
| 86 | Material and labour for Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level, Thermo-Mechanically Treated bars 8mm and over of grade Fe-500D or more complete all as specified and directed. |
| 87 | Material and labour for Centering and shuttering including strutting, propping etc. and removal of form for, Suspended floors, roofs, landings, balconies and access platform, for mass concrete complete all as specified and directed. |
| 88 | Providing and laying Concrete of M25 grade with minimum cement content of 300 kg /cum in position ready mixed or site batched design mix cement concrete for plain cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength, including pumping of concrete to site of laying, curing, carriage for all leads complete all as specified and directed. |
| 89 | Material and labour for Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc, 40 mm thick (with 20 mm nominal size stone aggregate),Complete all as specified and directed by Engineer-in-Charge. |
| 90 | Providing and laying Ceramic floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etccomplete all as specified and directed. |
| 91 | Material and labour for glazed, coloured ceramic tiles in verticle surface of size 450x350x7mm / 350x250x7mm thick set and joined in neat cement slurry and pointed in cement slurry and pointed in white or coloured cement to match over 10mm thick cement plaster in CM 1:3 complete all as specified and directed. |
| 92 | Providing and fixing aluminium tower bolt of size 150mm x 10mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc complete all as specified and directed. |
| 93 | Providing and fixing aluminium handles, 100mm size, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc complete all as specified and directed. |
| 94 | Supply & Fix rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position capacity 1000 ltrs and all as specified in SSR Part I, complete all as specified and directed. |
| 95 | Providing and fixing 20mm gun metal gate valve with C.I. wheel of approved quality (screwed end) screwed both ends for iron pipe complete all as specified and directed. |
| 96 | Providing and fixing 20mm bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete all as specified and directed. |
| 97 | Providing and fixing G.I. Pipes 15 mm dia nominal bore complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall, complete all as specified and directed. |
| 98 | Providing and fixing G.I. Pipes 20 mm dia nominal bore complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall, complete all as specified and directed. |
| 99 | Supply & Fix PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls or floor 75mm bore complete all as specified and directed. |
| 100 | Supply & Fix 75mm PVC(SWR) bends any radius with access door complete all as specified and directed. |
| 101 | Supply & Fix 75mm PVC(SWR) branch piece single(single) equal or unequal with access door complete all as specified and directed. |
| 102 | Supply & Fix 110mm bore single socket PVC (SWR) pipe, in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 103 | Supply & Fix PVC (SWR) bends any radius of 110mm bore complete all as specified and directed. |
| 104 | Supply & Fix PVC(SWR) branch piece, single Y equal or unequal of 110mm bore complete all as specified and directed. |
| 105 | Providing and fixing PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed. |
| 106 | Salt glazed stone ware gully trap 150mm square type 'P' includng MS gratings suitable to 150 x 150 mm gully trap and including PCC chamber 10 cm thick and RCC cover set in CM 1:6 complete all as specified and directed. |
| 107 | Supply & Fix in repairs Vitreous China wash basin, white, flat back, size White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps including brackets, including cutting for and pinning in ends of brackets or erecting stand and including 32mm bore waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and directed. |
| 108 | Providing and fixing in repairs C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms, 15 mm nominal bore complete all as specified and directed. |
| 109 | Providing and fixing in repairs C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931, 15 mm nominal bore complete all as specified and directed. |
| 110 | Providing & fixing in repairs White vitreous china water closet squatting pan (Indian type) Orissa pattern W.C Pan of size 580x440 mm, along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material complete all as specified and directed. |
| 111 | Providing and fixing in repairs P.V.C. low level flushing cistern, 10 litre capacity - White with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete all as specified and directed. |
| 112 | Providing and fixing uplasticised PVC connection pipe with brass unions, 15mm dia and 450mm long complete all as specified and directed. |
| 113 | Supply and Fix in repairs 40 mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm ² fixed complete to walls, ceilings or in floors etc, including all pipe fittings complete all as specified and directed. |
| 114 | Material and labour 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with ponge complete all as specified and directed (WPC shall be measured and paid separately). |
| 115 | Material and labour for 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) complete all as specified and directed. |
| 116 | Material and Labour for 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams complete all as specified and directed. |
| 117 | Material and labour for Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489: 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm complete all as specified and directed. |
| 118 | Removing excavated material to a distance upto 250m and depositing where directed at a level not exe 1.5m above the starting point complete all as specified and directed. |
| 119 | Returning filling in including spreading ,levelling , watering & well ramming in layers not exe 25cm, Complete all as specified and as directed by Engineer-in-Charge. |
| 120 | Material and labour for Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like with Cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed. |
| 121 | Material and labour for Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in cement mortar 1:6 complete all as specified and directed. |
| 122 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 25%) complete all as specified and directed. |
| 123 | Material and labour for Steel reinforcement Thermo-Mechanically Treated (TMT) bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding upto plinth level complete all as specified and directed. |
| 124 | Material and labour for Steel reinforcement Thermo-Mechanically Treated (TMT) bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level complete all as specified and directed. |
| 125 | Material and labour for Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns all complete all as specified and directed. |
| 126 | Material and labour for Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts complete all as specified and directed. |
| 127 | Providing and laying above plinth level ready mixed or site batched design mix cement concrete Concrete of M25 grade with minimum cement content of 350 kg /cum for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement complete all as specified and directed. |
| 128 | Providing and laying upto plinth level ready mixed or site batched design mix cement concrete Concrete of M25 grade with minimum cement content of 350 kg /cum for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement complete all as specified and directed. |
| 129 | Material and labour for MS steel work in single section, in angle and other section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and directed. |
| 130 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 sqm approved brand and manufacture complete all as specified and directed. |
| 131 | Material and labour GI Barbed wire Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used complete all as specified and directed. |
| 132 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) complete all as specified and directed. |
| 133 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 100 to 250 mm diameter complete all s specified and directed. |
| 134 | Constructing of soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 complete all as specified and directed. |
| 135 | M & L for LLDPE septic tank for 25 Users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete all as specified and directed. |
| 136 | Material and labour for Cement concrete type B -1, 1:2:4 (20mm graded aggregate) as in hardstanding, Path etc, complete all as specified and directed. |
| 137 | Providing and laying Forming 20 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’, complete all as specified and directed. |
| 138 | M&L for cement concrete paving tiles 300X300X25mm thick, rubber moulded, glossy finish with white cement and pigments set, jointed and pointed in net cement slurry in floors, and cut and polished complete all as specified and directed. |
| 139 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out hard rock (blasting prohibated) the excavated materials, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia complete all as specified and directed. |
| 140 | Providing and laying non-pressure NP2 class (light duty) 150mm dia R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc complete all as specified and directed. |
| 141 | M & L, for PCC (1 : 3: 6 ) type C2(using 40 mm graded aggregate) as in bed to drain pipe including packing under & haunching against the sides of pipes of 200 mm dia after they are laid tested complete all as specified and directed.Note: Thickness of bed below pipe shall be 10cm and width shall be outer dia of pipe plus 30cm. |
| 142 | Constructing brick masonry valve chamber with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) complete all as specified and directed. |
| 143 | Providing and laying 1:2:4 (1 cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%)excluding the cost of centering, shuttering and finishing complete all as specified and directed. |
| 144 | M&L PCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in surface channels and drains etc complete all as specified and directed. |
| 145 | Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 146 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 147 | Wiring for light point/Socket point/ fan point/exhaust fan point/call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC concealed conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. complete all as specified and directed.(a) For One light point controlled by one; one way switch |
| 148 | All as per item No 145 above but for One ceiling/Exhaust/ Wall fan point controlled by one ; one way switch |
| 149 | All as per item No 145 above but for One call bell point controlled by one ; one way switch |
| 150 | All as per item No 145 above but for One 3 pin 5 Amp socket out let controlled by one switch independent board. |
| 151 | M&L point wiring using approved colour coding as per IS with stranded copper conductor single core 2.5 Sqmm (Nominal area), PVC insulated FRLS cable in and including concealed PVC conduit ISI marked medium grade with all connecting accessories suitable for modular 3 pin socket outlet 15 amp on independent board , as required at site complete, incl PVC insulated copper conductor 2.5 Sqmm (Nominal area) single core PVC FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.Note : Modular Switch/sockets, cover and frame plate and other related items to be measured and paid for separately (Modular):- |
| 152 | M&L point wiring using approved colour coding as per IS with stranded copper conductor single core 4 Sqmm (Nominal area), PVC insulated FRLS cable in and including concealed PVC conduit ISI marked medium grade with all connecting accessories suitable for modular 3 pin socket outlet 15 amp on independent board , as required at site complete, incl PVC insulated copper conductor 4 Sqmm (Nominal area) single core PVC FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified. Note : Modular Switch/sockets, cover and frame plate and other related items to be measured and paid for separately (Modular):- |
| 153 | Supplying and fixing 3 module (100 mm x 75 mm) size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. complete all as specified and directed. |
| 154 | Supply and fixing 15/16 Amp switch, 1 module on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 155 | All as per item No 152 above but for 6 Pin 15/16 A socket outlet, 2 module |
| 156 | All as per item No 152 above but for 3 Pin 5/6A Socket outlet, 2 module |
| 157 | All as per item No 152 above but for Bell Push, 2 module |
| 158 | Supply and fixing call bell / buzzer suitable for single phase, 230 V complete all as specified and directed |
| 159 | Dismantling of ceiling/exhaust fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same complete all as specified and directed. |
| 160 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 161 | Supply and fixing General purpose industrial compact batten 2 x 20/22W suitable for single or twin LED Tube light with integral LED driver available in single / double side connection options complete with all accessories including pre wired and connecting up with twin core twisted flexible copper cable of suitable size complete all as specified and directed. |
| 162 | Supply and fixing Ultra bright LED Tubelight 20 watts with very high efficacy suited for installation in existing tubelight G13 lamp holders to give glare free light complete all as specified and directed. |
| 163 | Supply and fixing Basic all purpose surface and wall mounted LED batten 10 Watts with aluminum housing & integrated electronic driver complete with all accessories including pre wired and connecting up with twin core twisted flexible copper cable of suitable size all as specified and as directed. |
| 164 | Supply and fixing LED Bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 165 | Supply and fixing of 32/40 mm dia x 2.0 meter long G.I. pipe (medium class) bracket for mounting of / LED Bldg light fitting on pole/wall including bending the pipe to the required shape, 2 Nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. complete all as specified and directed. |
| 166 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 167 | Supply and fixing Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 168 | Supply and fixing LED Bulb 15 Watt, colour temperature 6500K complete all as specified and directed. |
| 169 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/wooden block including connections etc. complete all as specified and directed. |
| 170 | Supply and fix in repair Single pole and neutral enclosure with and including a two pin and earth plug and socket complete with and including one single pole MCB 20/32 Amps from wall surface and fixing (AC Socket) for AC including taking down old one Complete all as specified and directedcomplete all as specified and directed. |
| 171 | M & L Submain wiring comprising single core, 2 Runs of 2.5 sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC rigid non metalic concealed conduit conduit with necessary civil works for making good the disturbed surface with PVC conduits and conduit fittings complete including 1 x 2.5 sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. Note: 2 Runs of 2.5 sqmm cable and 1 run of 2.5 sqmm cable for earth wire and PVC conduit shall measured as one RM for the purpose of payment. |
| 172 | M & L Submain wiring comprising single core, 2 Runs of 4 sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC rigid non metalic concealed conduit conduit with necessary civil works for making good the disturbed surface with PVC conduits and conduit fittings complete including 1 x 4 sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. Note: 2 Runs of 4 sqmm cable and 1 run of 4 sqmm cable for earth wire and PVC conduit shall measured as one RM for the purpose of payment. |
| 173 | M & L Submain wiring comprising single core, 2 Runs of 6 sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC rigid non metalic concealed conduit conduit with necessary civil works for making good the disturbed surface with PVC conduits and conduit fittings complete including 1 x 6 sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. Note: 2 Runs of 6 sqmm cable and 1 run of 6 sqmm cable for earth wire and PVC conduit shall measured as one RM for the purpose of payment. |
| 174 | M & L Submain wiring comprising single core, 4 Runs of 10 sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC rigid non metalic concealed conduit conduit with necessary civil works for making good the disturbed surface with PVC conduits and conduit fittings complete including 2 x 6 sqmm nominal cross sectional area multistranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. Note: 4 Runs of 10 sqmm cable and 2 run of 6 sqmm cable for earth wire & PVC conduit shall measured as one RM for the purpose of payment. |
| 175 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. complete all as specified and directed. |
| 176 | Supplying and fixing 8 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, din bar, interconnecions, powder painted including earthing etc. as required and taking down old unserviceable one complete all as specified and directed. |
| 177 | Supplying and fixing 6 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, din bar, interconnecions, powder painted including earthing etc. as required complete including taking down old one complete all as specified and directed. |
| 178 | Supplying and fixing 4 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, din bar, interconnecions, powder painted including earthing etc. as required complete including taking down old one complete all as specified and directed. |
| 179 | Supply and Fixing 5A to 32A rating, 240V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of single pole in the MCB DB complete with connection, testing and commissioning etc as required including taking down old one complete all as specified and directed. |
| 180 | Supply and fixing 40 amp rating, 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole and neutral and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning including taking down old one complete all as specified and directed. |
| 181 | Supplying and fixing TPN vertical Loadline Distribution Board, 8 way, double door, suitable for TP/FP 'G' frame MCCBs, fitted with Bus Bars, Neutral Links, Blanking Plates (without MCCB) including takingdown old distribution board complete all as specified and directed. |
| 182 | Supplying and fixing TPN vertical Loadline Distribution Board, 4 way, double door, suitable for TP/FP 'G' frame MCCBs, fitted with Bus Bars, Neutral Links, Blanking Plates (without MCCB) including takingdown old distribution board complete all as specified and directed. |
| 183 | Supplying and fixing MCCB 100 Amps, four pole, 415 Volts, 16 KA in existing DBs including connecting incoming cable or wire with suitable size of lugs and thimbles acomplete all as specified and directed. |
| 184 | Material and labour for Earthing with GI earth plate 600mm × 600mm× 6mm thick including accessories,and providing masonary enclosure with cover plate having locking arrangment and watering pipe of 2.7 meter long etc with charcoal/ coke and salt, excavation and earth work as required in any type of strata including taking down old unserviceable earthing complete all as specified and as directed |
| 185 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required including taking down old one complete all as specified and as directed |
| 186 | Supply, installation, testing and commissioning of 1200 mm sweep, BEE, 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 Nos, canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019(, THD less than 10%, remote or electronic regulator unit for speed contro and all remaining accessories including safety pin, nut bolts, washers, temperature rise - 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC supply, earthing etc, complete all as specified and directed. |
| 187 | Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting including mounting on wall duly grouting with suitable bolts/fasteners connecting the same from ceiling rose to fan connector complete all as specified and directed. |
| 188 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers as required including making suitable opening asper fan size and connecting the fan from ceiling rose to fan connector complete all as specified and directed. |
| 189 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge inclduing painting etc. complete all as specified and directed.Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 190 | Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit for Telephone/LAN cabling complete all as specified and directed. |
| 191 | Taking down carefully street light fittings with bracket, wire and junction box from old corroded street light pole, taking out street light pole of any length, keeping in safe cusdoy for reuse /provision of sch or credit complete all as specified and directed.Note : Demolition of PCC coping and foundation concrete will be measured and paid separately. |
| 192 | M&L for demolition of cement concrete (Un-reinforrced) for any description and in any position not otherwise specifically provided for including shifting debris and deposited where directed complete all as specified and directed. |
| 193 | Supply, install and erect in true vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (09.0 metres long) includg painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting three black / red bands at lower portion of pole each of 300 mm height at 300 mm spacing, painting pole No with black paint at suitable height complete all as specified and directed. |
| 194 | Erection of steel tubular pole strut in cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc complete all as specified and directed.Note : Excavation and PCC shall be carried out upto planting depth of pole (i.e one sixth of length of pole) and 150 mm foundation also. |
| 195 | Providing and making steel pole collar with cement concrete (1:3:6) using stone aggregate 20 mm) of specified size and shape including form work, plastering if required, curing etc complete all as specified and directed. (Volume of pole/pipe not to be deducted).Note : Size of Coping will be 0.6mx0.6m x 0.3 m. |
| 196 | Supply and fixing of light grade class 'A' GI pipe of 40mm dia (Nominal) 3 mtrs (1.5 m x 2 Nos) length along the pole/wall/trench/ road/ culvertetc as per site requirement for protection of under ground cable complete all as specified and directed.Note : MS clamps and nuts, bolts/washers, where required are included in the quoted unit rate. |
| 197 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 198 | Supply and fixing of 50 mm dia x 1.5 metres long GI pipe (medium class) bracket for mounting of street light fitting on pole including bending the pipe and GI reducer nipple to the required shape, 2 Nos 40mm x 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint etc complete all as specified and directed. |
| 199 | Supply and fix pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300 x 200 x 105mm (internal) comprising of 63A power terminal block 4 ways, One No SP MCB single pole of capacity 6 amps 240 volts duly fixed on DIN rail 'C' type and one No. terminal for loop in & loop out suitable for three phase street light system including nuts, bolts and wahsers, MS clamp fabricated from 25x3mm flat iron complete mounted on pole complete all as specified and directed. |
| 200 | Supply and Fix Automatic Transfer Switch with enclosure, 4 pole, 250 Amps Capacity, 50 HZ, 415 volts with automatic/manual with complete protection and controller for existing DG set (for 2 Nos Supply, One DSC Mess and 2nd different security system of gate) complete all as specified and directed. |
| 201 | Supply and drawing 3 x 1.5 sq mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ steel tubular swaged pole complete all as specified and directed. |
| 202 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of LT under ground cable and getting out in the following type of earth stata complete all as specified and directed :- (a) Soft/ loose Soil |
| 203 | Ditto all as per item no 200 above but Hard / dense soil |
| 204 | Supply and lay in trenches Un- reinforced precast concrete cable cover class LV type 1 flat size 250 x150 x 40 mm for cable protection complete all as specified and directed. |
| 205 | Supplying, spreading, leveling and well ramming in layers not exceeding 20 cm in height sand filling for under ground cable protection including watering and consolidation complete all as specified and directed by Engr-in-Charge .complete all as specified and directed. |
| 206 | M & L for returning/filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres complete all as specified and directed. |
| 207 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 208 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed. |
| 209 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed. |
| 210 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed |
| 211 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed |
| 212 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed |
| 213 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 214 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 215 | M&L for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised earth lead strip 25 x 5 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab GI funnel with GI watering pipe 20mm dia med grade, wire mesh, protection pipe 20mm dia GI pipe light grade for earth lead upto 7.50 m long complete all as specified and directed. |
| 216 | Supply and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc as required at site complete all as specified and directed. |
| 217 | Taking out existing old unserviceable LT pane of any type after disconnecting incoming and all outgoing cables, switch gears. transportation the panel from site and keeping where directed for further issue credit complete all as specified and directed. |
| 218 | Supply, installing, testing and commissioning, factory made and type tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary insulated bus bar arrangement of 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15 mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc., independent chamber to accommodate complete including PCC foundation all as specified and directed including following accessories :- INCOMING: (a) Bus bar chamber with electrolytic aluminium bus bar suitable for 400 amps capacity for 3 phase and neutral (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrieked insulating sleeves Set -1 (b) MCCB 4 pole 250 Amps 36 KA, 415 Volt adjustable thermal/magnetic setting type – 01 No |
| 219 | OUTGOING: (a) MCCB 4 Pole adjustable thermal/magnetic setting type 100 Amp 415 volts 25 KA - 03 Nos (b) MCCB 4 Pole adjustable thermal/magnetic setting type 63 Amp 415 volts 25 KA - 01 Nos (c) MCB TP 'C' Curve 32 Amp 415 volts 10 KA - 01 Nos (d) Indicator lamp 22.5 mm dia RYB, 230 volts, controlled by toggale switches - 02 Set. (e) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end terminaion lugs. (f) Digital type voltmeter panel mounted flush type of size 96 X 96 sq mm three phase class 1.0 with in built selector switch complete. Each - 1 (g) Austronomical Street light timer panel of rating 12 kW, conforms to IS/IEC 60947-4-1, provided with Protection Degree IP 54, extended wide band coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation including 65 Amps TP MCB 'C' Curve, 10 KA, 415V one No. and MCB SPN 63A, 'C' curve, 10 KA, 415V one No |
| 220 | Supply install, testing and commissioning of Energy rating BEE 5 Star Split Air Conditioning capacity 2 TR with indoor and outdoor unit having comprising of the following :-(a) Multistranded copper conductor wire 3 core 4 Sqmm with copper lugs upto 10.0 mtrs.(b) Incoming and outgoing quality copper pipe with foam insulation duly whiled taped of each size upto 10.0 mtrs(c) Having 02 Nos of bracket duly powder coated with anchor fasteners, nuts, washers set -01(d) Key features (i) Multi adjustable mode (ii) High ambient cooling (iii) Super dry (iv) Turbo cooling (v) ECO friendly Refrigerant R-410A (vi) 100% copper condenser (vii) Sleep mode (viii) Wide voltage range operation (ix) The ISEER value of Air Conditioner shall be 4.5 (Minimum) (x) Cordless remote -01 No Please Enable Macros to View BoQ information |
| 221 | Supply install, testing and commissioning of Energy rating BEE 5 Star Split Air Conditioning capacity 2 TR with indoor and outdoor unit having comprising of the following :-(a) Multistranded copper conductor wire 3 core 4 Sqmm with copper lugs upto 10.0 mtrs.(b) Incoming and outgoing quality copper pipe with foam insulation duly whiled taped of each size upto 10.0 mtrs(c) Having 02 Nos of bracket duly powder coated with anchor fasteners, nuts, washers set -01(d) Key features (i) Multi adjustable mode (ii) High ambient cooling (iii) Super dry (iv) Turbo cooling (v) ECO friendly Refrigerant R-410A (vi) 100% copper condenser (vii) Sleep mode (viii) Wide voltage range operation (ix) The ISEER value of Air Conditioner shall be 4.5 (Minimum) (x) Cordless remote -01 No Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender