Tender for Repair And Maintenance Of Lt Feeder Panels, Earthings, Ug Cable And Allied Works At Si Line Under Ge Bhopal
BOQ
| Sl. No. | Item Description |
| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Taking out old unserviceable cable from trenches of any size and any type complete all as specified and directed. |
| 3 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard/dense soil complete all as specified and directed. |
| 4 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable pipe and getting out in soft disintegrated rock all as specified and directed. |
| 5 | M&L for making good the disturbed surface by filling PCC 1:2:4 type B-1 using 20 mm graded stone aggregate to match with existing surfaces all as specified and directed. |
| 6 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed |
| 7 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 8 | M&L local dry sand , filling in trenches around under ground cable complete all as specified and directed. |
| 9 | M&L for providing of new reinforced precast concrete cable cover Type - I flat LV cable cover, size 250mm x 150mm x 40mm for protection of under ground cable complete all as specified and directed. |
| 10 | Supply, Laying, connecting and testing LT XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade ISI marked laid in trenches, passing through pipes/ducts, on walls with shadel, etc of following Alluminium conductor of size 120 sq mm , 3.5 core complete all as specified and directed. |
| 11 | All as per ser item no. 9.00 here-in-before but Alluminium conductor of size 95 sq mm , 3.5 core complete all as specified and directed |
| 12 | All as per ser item no. 9.00 here-in-before but Alluminium conductor of size 50 sq mm , 3.5 core complete all as specified and directed |
| 13 | All as per ser item no. 9.00 here-in-before but Alluminium conductor of size 25 sq mm , 4 core complete all as specified and directed |
| 14 | All as per ser item no. 9.00 here-in-before but Alluminium conductor of size 16 sq mm , 4 core complete all as specified and directed |
| 15 | All as per ser item no. 9.00 here-in-before but Alluminium conductor of size 10 sq mm , 4 core complete all as specified and directed |
| 16 | All as per ser item no. 9.00 here-in-before but Alluminium conductor of size 10 sq mm , 2 core complete all as specified and directed |
| 17 | Dismantling cross arms, bracings , supports , clamps and back plates from existing poles (other than dismantled poles) and pole structures complete all as specified and directed. |
| 18 | M&L for replacement of cross arms , bracings, supports, clamps and back plate fabricated from structural sections including nuts, bolts, and washer bending hot or cold , drilling holes for bolts of any size and painting with two coats of aluminum paint over one coat of red oxide primer including preparation of surfaces, complete all as specified and directed by the Engr-in-Charge. |
| 19 | M& L for replacement of Polymer pin type insulator GI washer and one GI nut for 1100 Volt grade complete all as specified and directed. |
| 20 | M& L for replacement of Polymer disc insulator ball & socket type with tension clamp and accessories suitable for conductor single disc assy working pressure 1100 volts complete all as specified and directed. |
| 21 | Supply , replacement & stringing the ACSR conductor, including binding wire, tape and jumper complete all as specified of size as ordered. |
| 22 | M&L for stringing of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length ( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified. ( Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge) . Note:- Five lines together will be measured as one span from pole to pole. |
| 23 | Supply and fix in replacement cable saperator heavy duty made of plastic with PVC clamps heavy duty three phase separator complete all as specified and directed. |
| 24 | Supply and fix in replacement cable saperator heavy duty made of plastic with PVC clamps heavy duty two phase separator complete all as specified and directed. |
| 25 | Supply and fix in replacement of cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4 mm dia as in repairs complete all as specified and directed. |
| 26 | M&L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized iron strip 32X6mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 part – I connected to machinery/equipment for Timer Panel etc. as required 32x6 mm dia galvanized iron with 40mm GI light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in PCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and 20mm bore GI watering pipe medium grade, etc. complete all as specified and directed. |
| 27 | M&L for installing GI strip of 32x6 mm dimensions and making proper arrangements for connection between earthing and Transformer/ equipment all as specified and directed by Engineer in charge. Please Enable Macros to View BoQ information |
| 28 | M&L for installing GI strip of 32x6 mm dimensions and making proper arrangements for connection between earthing and Transformer/ equipment all as specified and directed by Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysSep 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender