Tender For Repair/ Replacement Of Old Vintage Fresh Water And Raw Water Pipe Line, Sluice Valve, Air Released Valves, Valve Chamber And Other Connected Items At Gunjkheda Pump House, Cmph, Picket Hill Pump House, Arjun Line, Map Qtr Area Area Under G

Issued by Statutory Bodies & Commissions/Committees · Wardha, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2026
11 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Wardha → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Old Vintage Fresh Water And Raw Water Pipe Line, Sluice Valve, Air Released Valves, Valve Chamber And Other Connected Items At Gunjkheda Pump House, Cmph, Picket Hill Pump House, Arjun Line, Map Qtr Area Area Under Ge Pulgaon

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF OLD VINTAGE FRESH WATER AND RAW WATER PIPE LINE, SLUICE VALVE, AIR RELEASED VALVES, VALVE CHAMBER AND OTHER CONNECTED ITEMS AT GUNJKHEDA PUMP HOUSE, CMPH, PICKET HILL PUMP HOUSE, ARJUN LINE, MAP QTR AREA AREA UNDER GE PULGAON
Sl. No. Item Description
1Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed.
2Returning, filling in, including spreading, leveling watering and well ramming in layers of soil not exceeding 25cm.
3Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of rock.
4Supply and fix cast iron in new pipes with spigot and socket ends centrifugally casted class LA in any length suitable for rubber tytan joint and Laid in trenches of size 100mm bore. At FSD area
5Supply and fix cast iron in new pipes with spigot and socket ends centrifugally casted class LA in any length suitable for rubber tytan joint and Laid in trenches of size 200mm bore. At FSD area
6M&L for rubber tyton joints for suitable for sockets and spigot CI pipes including rubber gasket of size 100mm bore.
7M&L for rubber tyton joints for suitable for sockets and spigot CI pipes including rubber gasket of size 200mm bore.
8S&F in new MS pipe 150 mm dia ligth grade A class both end flanged including making flanged joint, rubber gasket, nuts & bolts washers,nut and bolts complete all as specified and as directed.At FSD area
9M&L for fixing in replacement of CI air release valve heavy duty single end flanged incl making flanged joint, rubber gasket, nuts & bolts washers sizes 100 mm complete allas specified and directed. Make:Kirloskar/Upadhayaya/Aarko
10Taking out M&L for repaire of CI air release disconnected parts after replacing unserviceable parts with the new parts of same like rubber gasket, nuts & bolts washers ,ball of size sizes 100 mm/75mm, refixing including Repacking complete all as specified and directed.
11Supply, installation, testing andcommissioning of Open well submersible pump sets 10 HP,electric driven,RPM-1450rpm, Driver rating-45KW, 415 volt,50HZ head 60 mtr, flow 3000 LPM, as directed. Make- L&T/Siemens/Schneider (CG).
12M&L for in repair of rusted & crack CI/DI water branch connection 150 to 300mm dia by using mechanical joint with connecting all accessories complete all as specified and directed byEngineer-in-Charge. Note :(i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in cost of above job.ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate.(iii) Excavation for pipe is included in item rate.
13Disconnection and removing the broken S/S spindle with checknut and S&F brass spindle of same size and length along with checknut suitable for sluice valve 300 mm bore PN 1.6/PN1 of exisisting makes including threading machining and Lathe work complete along with fixing material such as gland packing nut and bolts complete.
14Disconnection and removing the broken S/S spindle with checknut and S&F brass spindle of same size and length along with checknut suitable for sluice valve 200 mm bore PN 1.6/PN1 of exisisting makes including threading machining and Lathe work complete along with fixing material such as gland packing nut and bolts complete.
15Disconnection and removing the broken S/S spindle with checknut and S&F brass spindle of same size and length along with checknut suitable for sluice valve 150 mm bore PN 1.6/PN1 of exisisting makes including threading machining and Lathe work complete along with fixing material such as gland packing nut and bolts complete.
16M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 150 to 300 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, etc. including nuts, bolts and washers and necessary boring to match the existing pipe complete all as specified and as directed,
17S &F of single phase preventor(Phase failure relay) 415Volt,50 Hz,Type-VSP 3 complete all as specified and directed.
18a) Supply & fix of reputeded make full bore SCADA based Electromagnetic flowmeter, size 300mm callibrated with certificate, including all accesseries, cable length- as required, local display- manual reading, remote monitoring- reading see in mobile and laptopand also print last six month hestorical DATA/Excel formate. Enclosser panel- safty Cever Meter, UPS - To Give 3 hours battery backup. With One Year Warranty. b) Supply and installing of all fitting including CI flange addeptor and jointing matterial etc. and commisining of Meter al as directed by Engr-in -Charge. ( CMPH/PKT Hill Pump House)
19Supply only Rubber tyre Pulley along with nut, bolts and key unit complete set suitable for 120 HP pump set
20Dismantling the motor of submersible (vertical type) pumpset of capacity 3 HP/5 HP., removing the existing burnt out winding and re-winding with PVC copper winding wire of existing gauge and weight including replacement of all insulation material, \\"O\\" rings and filling of cooling oil with oil seal and terminal lead for AC, three phase, 415Volts grade and other petty items required for making motor functional and motor reassembling and testing complete all as directed
21M&L for burning out lead joint in position , including removing lead to store / stacked at site to issue under credit of 250/300mm bore CI Pipe line
22M&L for Run lead joint of 250/300 mm bore of spigot socket pipes and fitting, including caulking properly and making joint leak proof all as directed and as specified.
23Supply & fix in replacement champion/turner style graphite gland packing of sizes as 8/10/12/16mm thick. For motor/sluice valve.
24M&L in repair chequered plate frame work in installed plates on semi UG sump as per sample including cut to required size and making provision of handle made out of 6 mm plane rod,including painting with two coats of synthetic enamel paint over one coat of red oxide at CMPH, Gunjkheda pump house.
25Taking down existing UNSV sluice valve and supply & fix new Sluice valve of 80mm bore rising spindle type (Gear type) PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and oprating wheel.
26Taking down existing UNSV sluice valve and supply & fix new Sluice valve of 100mm bore rising spindle type (Gear type) PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and oprating wheel.
27Taking down existing UNSV sluice valve and supply & fix new Sluice valve of 150mm bore rising spindle type (Gear type) PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and oprating wheel.
28Taking down existing UNSV sluice valve and supply & fix new Sluice valve of 200mm bore rising spindle type (Gear type) PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and oprating wheel.
29Taking down existing UNSV sluice valve and supply & fix new Sluice valve of 250mm bore rising spindle type (Gear type) PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and oprating wheel.
30Taking down existing UNSV sluice valve and supply & fix new Sluice valve of 300mm bore rising spindle type (Gear type) PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and oprating wheel.
31Supply, installation, commissioning and testing of DOL stater fully automatic suitable for upto 10HP monoblock pump, 415 volts 3 phase, 50 Hz,10-40A including taking out of existing u/s starter as directed. Make- L&T/Siemens/Schneider (CG).
32Supply & Fix, testing of 0.5 HP cap self priming single phase ,Drip proof adapter, anti jam winding including all acessoriese all as directed by Engr - In- Charge
33Supply & Fix, testing of 1 HP cap induction motor, anti jam winding,Drip proof protection mechanical sealed,Elctric start 230 volt as per site requirment including all acessoriese all as directed by Engr - In- Charge
34Supply, installation, commissioning and testing of DOL stater fully automatic suitable for upto 2HP monoblock pump, 415 volts 3 phase, 50 Hz,10-40A including taking out of existing u/s starter as directed. Make- L&T/Siemens/Schneider (CG).
35Supply, lay, connecting, jonting and testing Reinforced concrete pipes, class NP2, laid and jointed complete with collars pressure pipe of dia 600mm
36HDPE flexible pipe for sunction and delivery of diesel driven mud pump 80 mm dia of presure rating 2.5 Kg/Sqcm alogwith coupling socket set clamps & clips complete all as specified and directed.
37Testing of Treated water (Drinking water) sample as per IS - 10500 including collecting of sample from the pump house and handed over it to the authoriesed NABL lab for the testing purpose all as specified and directed.
38Testing of Raw water sample as per IS - 10500 including collecting of sample from the pump house and handed over it to the authoriesed NABL lab for the testing purpose all as specified and directed.
39Supply, installation, commissioning and testing of RO Model No.100 LPH Commercial RO ,Brand : KENT 84212190including pre Filter 20\\" or as per requarement rates are included with one year AMC including supply and fixall consumable spare parts all as directed by Engineer -In Charge.
40Material and labour in replacement of Unplasticiscd PVC pipes including all fittings of pressure rating 10 kgf/cm2 laid in trenches of size 40mm dia.
41Material and labour in replacement of UPVC pipes including all fittings of pressure rating 10 kgf/cm2 aid in trenches of size 50mm dia.
42Supply of First Aid kit Complete with plastic box containing absorbent cotton wool,sterile gauze pads , bandage rolls, adhesive bandage , surgical tape, antiseptic solution, antisaptic oinment, pain relief spray, disposal gloves, scissores, thermometer, and other standard, firstaid items complete all as direccted.
43Supply and fixing of shock treatment printed in Hindi and English with pictorial instructions for treeatment of electrical sock and saving of water, casualties, laminated and mounted on hard board /Frame sutaiblefor wall mounting complete as required all as direccted by Engr - In - Charge.
44Supply and fixing of water saving Chart printed in Hindi and English with pictorial instructions for treeatment of electrical sock and saving of water, casualties, laminated and mounted on hard board /Frame sutaiblefor wall mounting complete as required all as direccted by Engr - In - Charge.
45Supply and laying or fixing or passing through pipe in replacement ,testing and commissioning 1100 volts grade heavy duty cable with PVC insulated multi strand copper conductor cable size 95 Sqmm, single core unsheathed flexible including of suitable size lugs and connection plate of sutiable type all as specied and as directed
46Supply, installation, commissioning and testing in replacement of smart soft star delta stater fully automatic ,LCD based,Digital type time setting and Smart/Auto switch ,protects to motor against reverse running & fluctuated voltage conditions for 120 HP centrifugal pump, 440 volts 3 phase, 50 Hz as directed. Make- L&T/Siemens/Schneider (CG).
47Supply only Salt (Sodium Chloride -NaCl) White,Crystalline, solid.
48Supply only qrease fine quality. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57004734
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 27-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Old Vintage Fresh Water And Raw Water Pipe Line, Sluice Valve, Air Released Valves, Valve Chamber And Other Connected Items At Gunjkheda Pump House, Cmph, Picket Hill Pump House, Arjun Line, Map Qtr Area Area Under Ge Pulgaon
Basic Detail
Tender No 8372/E8
Bidding Type Tender
Location
City Wardha
State Maharashtra
Key Dates
Publish Date 13 Aug 2026
Submission Date 27 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 90000
Exemption Available
Document List
a43f7735-51f8-493f-aa8e-ad830b1277d7.html
BOQ_878888.xls
Tenderdocus8372.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

a43f7735-51f8-493f-aa8e-ad830b1277d7.html

xls

BOQ_878888.xls

pdf

Tenderdocus8372.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders