Tender For Repairs/Maintenance Of Fans, Geysers And Energy Meters And Connected Works At Varunapuri, Dcra And Otm Accommodation Under Ge (Nw) Vasco.(Tender Id No. 2026_Mes_784431_1)
Tender Value
40 Lakhs
Estimated cost
Bid Submission
03 Sep 2026
19 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs/Maintenance Of Fans, Geysers And Energy Meters And Connected Works At Varunapuri, Dcra And Otm Accommodation Under Ge (Nw) Vasco.(Tender Id No. 2026_Mes_784431_1)
BOQ
| Sl. No. | Item Description |
| 1 | Taking down U/S aluminium/copper point wiring complete including fittings and fixtures such as switches, ceiling roses, regulators, etc removing materials (credit for above items should be made as per conditions seperately) and making good the disturbed surface all as directed . |
| 2 | M/L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor and connected to earth dolly etc,including metal box and top sheet for switches and sockets, complete all as specified and directed. |
| 3 | One point controlled by one switch. |
| 4 | All as per item No 2 above but complete with 1100volt grade PVC insulated unsheathed multistranded wire with 2.5 sqmm copper cable through casing and capping of suitable size and one run of 2.5 sqmm copper cable as earth continuity conductor including connecting with earth dolly complete all as specified and as directed. |
| 5 | S/F in repair switch piano, flush type single pole, one way 6 Amp complete all as specified and directed. |
| 6 | Supply and fix in repairs Swtich socket combination 2 in 1, 6A 3 Pin and 6A 2 pin combined flush type, 230 V ,complete all as specified and directed by Engineer in charge. |
| 7 | Supply and fix in repair switch socket combination 2 in one 3 pin 6 A and 3 pin 16 A Combined flush type. |
| 8 | S/F in repair ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body complete all as specified and directed. |
| 9 | Supply and fix in repairs Ceiling fan regulator electronic step switch type/socket type(Matching to existing location), suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete all as specified and directed by Engineer in charge. |
| 10 | Supply & Fixing step type modular electronic fan regulator flush type 2 module for 1200 / 1400 mm sweep ceiling fan including taking down existing regulator.Make: Matching to existing location. |
| 11 | Supply and fixing in repairs SP 6 To 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 12 | Checking and dismantling of ceiling fan of any make and sweep 1200 mm from its installed location servicing the fan by cleaning , greasing, oiling, painting with two coat of existing colour including replacement of worm out nut bolts with rubber reel , split pins, quarter pin, push bearing, ball bearing, Fan blade, Fan motor, Rewinding, Down rod, Capacitor and check nuts and installing back to its original position complete all as specified and directed. Note:- painting, nut bolts with rubber reel, split pins/quarter pin, push bearing, ball bearing, Fan blade, Fan motor, Rewinding, Down rod, Capacitors and check nuts shall be measured and paid seperatly. |
| 13 | Supply and Fix in repair Fan motor Complete suitable for 1200mm sweep ceiling FanMake : Matching the existing site |
| 14 | Supply and fix in repair Fan Blade suitable for 1200 mm Sweep ceiling FanMake : Matching the existing site |
| 15 | Supply and fix in repairs rubber reel with MS nut Bolt,split/quarter pin for hanging ceiling fan suitable for C/fan complete all as specified and directed. |
| 16 | Supply and fix in repairs ball bearing suitable for size of Ceiling fan any type and any make complete all as specified and directed. |
| 17 | Supply and fix in repair ceiling fan down rod for hanging ceiling fan of suitable length matching to the existing location complete all as specified and directed. |
| 18 | M&L for Painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filter, two coats after cleaning att dust etc. |
| 19 | Supply and fix in repairs capacitor of capacity 2.5mfd , 230 V for ceiling fan including removing old one complete all as specified and directed. |
| 20 | Checking and dismantling of Exhaust fan of any make (Plastic/Metal) and sweep up to 300 mm from its installed location servicing the exhaust fan by cleaning ,greasing,oiling,painting with two coat of existing colour, Fan blade, Fan Motor, ball bearing, anchor fastner bolt, Rewinding, capacitors and installing back to its original position complete all as specified and directed. Note:- painting, Fan blade, Fan Motor, ball bearing, anchor fastner bolt, Rewiring, Capacitor and check nuts shall be measured and paid seperatly. |
| 21 | Supply and Fix in repair Fan motor complete suitable any make and sweep up to 300 mm Sweep exhasut Fan (Metal) matching to existing locationMake matching to existing lication. |
| 22 | Supply and Fix in repair Fan Blade suitable of any make and sweep up to 300 mm sweep Exhaust Fan (Metal) matching to existing location. |
| 23 | Supply and fix in repairs Exhaust fan body/frame suitable any make and sweep up to 300 mm exhaust fan(Metal) Matching to existing location complete all as specified and directed. |
| 24 | Supply and fix in repairs capacitor for Exhaust fan (Metal) of capacity Matching to existing location , 230 V for ceiling fan including removing old one complete all as specified and directed. |
| 25 | M&L for Painting of Exhaust fan(Metal) complete, in situ with synthetic enamel paint by spraying including filling cavities with filter, two coats after cleaning att dust etc. |
| 26 | Supply and Fix in repair Fan motor complete suitable any make and sweep up to 300 mm Sweep exhasut Fan (Plastic) matching to existing locationMake :- matching to existing location. |
| 27 | Supply and Fix in repair Fan Blade suitable of any make and sweep up to 300 mm sweep Exhaust Fan (Plastic) matching to existing location. |
| 28 | Supply and fix in repairs Exhaust fan body/frame suitable any make and sweep up to 300 mm exhaust fan(Plastic) Matching to existing location complete all as specified and directed. |
| 29 | Supply and fix in repairs capacitor for Exhaust fan (Plastic) of capacity Matching to existing location , 230 V for ceiling fan including removing old one complete all as specified and directed. |
| 30 | Supply and fix in repairs anchor fastner/nut bolt suitable any make and sweep up to 100 mm for Exhaust fan or Geyser complete all as specified and directed. |
| 31 | M&L for Rewinding of u/s ceiling/exhaust fan and opening the body cover of c/fan, exhaust fan, any type , any make and cutting the existing winding without damaging the stator removing the coil insulation and rewinding with new wire of suitable gauge with correct number of turns of auxiliary and main winding , varnishing and baking complete and soldering new lead of copper wire three core cables of size 23/0.0076 testing, refixing and commissioning complete including transportation from area of AGE E/M II to workshop complete all as specified and directed for the following sizes . |
| 32 | C/Fan 1200mm sweep |
| 33 | Exhaust fan up to 300 mm sweep (Plastic/Metal) |
| 34 | Removing inlet and outlet waterconnection , taking down existing Geysers storage type 10/15/25/50 Ltr capacity and then checking of thermostate , heating element, 15 Amp Plug Top and socket, PVC connection pipe hot and cold, NRV and safety devices inner control valves, cables etc including cleaning of inner storage tank complete and fixing back testing complete all as directed.Note :- U/S items to be replaced shall be measured and paid separately. |
| 35 | Supply & Fix in repairs thermostat BI- metal thermal relay suitable for 10/15/25 ltrs geyser |
| 36 | Supply & Fix in repairs indicator lamp for geysers |
| 37 | Supply & Fix in repairs heating element threaded/ push type 1500 watts/ 2000 watts for 10/15/25 Ltr geysers of any make |
| 38 | Supply & Fix in repairs PVC connection heavy duty 15mm size with PTMT nut of length 450 mm for hot /cold water connection |
| 39 | S&F in repairs PVC three core cable 2.5 sqmm sheathed cable copper conductor |
| 40 | Supply & fix in repairs 15 Amps plug Top for geysers complete all as specified and directed . |
| 41 | S & F repair suitable non return valve for any type of Geyser |
| 42 | Supply and fix in repairs industrial metal clad socket, 3 pin, including 20 amp mcb SP and 3 pin Plug top, concealed on wall and making the surface good, matching with the existing wall complete all as specified and directed by Engineer-in-Charge |
| 43 | Checking and attending day to day electrical complaints for continuous electric supply like No light / Short circuit / non working fittings / fixtures/Meter fauly( checking by sub meter), including carrying out the minor repair like fixing screws, repair/replacements of short wire, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.5 mtr length and maintenance work complete on all working days all as directed by Engineer-in-Charge. Note: (a) Rate inclusive of small items like, screws, wire,etc . |
| 44 | Supply and Fix in repairs for louvers of any make up to 300 mm exhaust fan (metallic), at any Bldg and at any Floor complete all as specified and as directed by Engr in Charge. |
| 45 | Note for item No 1-42:- (a) All Items form serial no 1 to 42 should be done against the daily complaints.(b) Contractors are advised to visit the sites before quoting their rates.(c) Materials for repair works as directed by Engineer-in-Charge shall be supplied by the contractor and adequate stock shall be held all the time by contractor (d) Any nature of electrical complaint, the entire responsibilty of rectification lies with the contractor. (e) All serially numbered complaint docket will be provided by contractor and cost of docket included in the rate quoted for the items.(f) All T&P, safety gadgets shall be provided by the contractor.(g) Rep of the contractor shall receive complaints in morning 0900 hr and give feedback on daily basis to concerned JE E/M by the end of the day Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender