Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #57004730

Tender For Repair/ Maintenance Of Unserviceable Items Of Solar Lights, Water Heaters, Street Light And Associated Work Under Age E/M Of Under Ge 871 Ews.

Issued by Statutory Bodies & Commissions/Committees · Chamoli, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Aug 2026
3 days left
EMD
19800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chamoli → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Unserviceable Items Of Solar Lights, Water Heaters, Street Light And Associated Work Under Age E/M Of Under Ge 871 Ews.

BOQ

Name of Work:- REPAIR/ MAINT OF UNSERVICEABLE ITEMS OF SOLAR LIGHTS, WATER HEATERS, STREET LIGHT AND ASSOCIATED WORK UNDER AGE E/M OF UNDER GE 871 EWS.
Sl. No. Item Description
1SCHEDULE 'A' PART-I : BOQ OF WORKS FOR E/M WORKS.
2Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 4.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
3Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 6.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
4Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0metre apart including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
5Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for laying of cables, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, any type of soil, complete all as specified and as directed.
6Steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-31 (9.00 meters long), including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the exposed to view entire surface and two coats of bituminous paint on embedded portion, making three Nos circular strips, each 100mm wide with one No of yellow colour in middle and two Nos of black in colour, endorsing pole number with black paint on yellow strip, complete all as specified and as directed.Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
7Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation of poles or laying of cables, etc., not exceeding 10 Sqm on plan and getting out in any type hard rock, complete all as specified and as directed.Note: Stone retrieved from excavation shall be issued to contractor.
8Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed.
9Plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, or in foundation of poles and stays, complete all as specified and as directed.
10Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of pole's foundation including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed.
11Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed.
12Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed.
13Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed.Note: Punned thickness shall be measured.
14Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed.
15Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
16Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
17Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
18Tubes, 'light grade' galvanised, 50mm bore, ISI marked including all fitting such as bends, socket, connectors, back nuts, etc, laid in trenches or under floors, complete all as specified and as directed. Please Enable Macros to View BoQ information
19Tubes, 'light grade' galvanised, 50mm bore, ISI marked including all fitting such as bends, socket, connectors, back nuts, etc, laid in trenches or under floors, complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57004730
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 27-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Unserviceable Items Of Solar Lights, Water Heaters, Street Light And Associated Work Under Age E/M Of Under Ge 871 Ews.
Basic Detail
Tender No 8161/E8
Bidding Type Tender
Location
City Chamoli
State Uttarakhand
Key Dates
Publish Date 13 Aug 2026
Submission Date 27 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 19800
Exemption Available
Document List
Tendernotice_1.pdf
b81873ca-6c5d-4a22-bca8-b175140cdf2f.html
BOQ_878969.xls
E-Tender.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

b81873ca-6c5d-4a22-bca8-b175140cdf2f.html

xls

BOQ_878969.xls

pdf

E-Tender.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders