Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #57004721

Tender For Repair / Maintenance Of Lt Panels Incl Apfc Panels, Servo Stabilizers And Connected Ug Cables, Overhead Lines At North Side Runway Of installation Hansa Under Ge (Nw) Vasco.(Tender Id No. 2026_Mes_784387_1)

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
45 Lakhs
Estimated cost
Bid Submission
03 Sep 2026
10 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Lt Panels Incl Apfc Panels, Servo Stabilizers And Connected Ug Cables, Overhead Lines At North Side Runway Of installation Hansa Under Ge (Nw) Vasco.(Tender Id No. 2026_Mes_784387_1)

BOQ

Name of Work:- REPAIR / MAINT OF LT PANELS INCL APFC PANELS, SERVO STABILIZERS AND CONNECTED UG CABLES, OVERHEAD LINES AT NORTH SIDE RUNWAY OF INS HANSA UNDER GE (NW) VASCO.(Tender ID No. 2026_MES_784387_1)
Sl. No. Item Description
1Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level all as specified.
2Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
3Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
4Supply and filling in and speading clear sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose.
5Supply and lay un-reinforced precast concrete cable covers, class LV , type- I with peak, size 250 mm x 150mm x 40 mm, all as specified and as directed.
6Supply and lay Double walled corrugated pipe (DWC ), heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
7Supply & Laying jointing, testing and commissioning LT XLPE cable, PVC insulated, PVC sheathed armoured LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, induct, on poles, in trenches etc including taking down complete of following sizes :-
8400 Sqmm 3.5 Core
9300 Sqmm 3.5 Core
10240 Sqmm 3.5 Core
11120 Sqmm, 3.5 core.
1295 Sqmm, 3.5 core.
1370 Sqmm, 3.5 core.
1450 Sqmm, 3.5 core.
15Supply and fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing of following sizes:-
1625 to 35 Sqmm 4/3.5 core
1750 Sqmm 4/3.5 Core
1870 Sqmm 4/3.5 Core
1995 Sqmm, 4/3.5 core
20120 to 150 Sqmm, 4/3.5 core
21185 Sqmm, 4/3.5 core
22240 Sqmm, 4/3.5 core
23Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of following sizes including dismantling and taking down existing pipe.
2480mm bore
2550mm bore
2640mm bore
27Supply and fix in repair MCCB 63 Amps,16 KA,Adjustable type,415 volts,FP,50 Hz complete all as specified and directed.
28Supply and fix in repair MCCB 100 Amps,16 KA,Adjustable type,415 volts,FP,50 Hz complete all as specified and directed.
29Supply and fix in repair MCCB 160 Amps,25 KA,Adjustable type,415 volts,FP,50 Hz complete all as specified and directed.
30Supply and fix in repair MCCB 200 Amps,35 KA,Adjustable type,415 volts,FP,50 Hz complete all as specified and directed.
31Supply and fix in repair MCCB 250 Amps,35 KA,Adjustable type,415 volts,FP,50 Hz complete all as specified and directed.
32Supply and fix in repair MCCB 400 Amps,35 KA,Adjustable type,415 volts,FP,50 Hz complete all as specified and directed.
33Supply and fix in repair MCCB 630 Amps,50 KA,Adjustable type,415 volts,FP,50 Hz complete all as specified and directed.
34Supply and fix in repair MCB 63 Amps,10 KA,415 volts,FP,50 Hz complete all as specified and directed.
35Supply and fix in repair MCCB 63 Amps,16 KA,Adjustable type,415 volts, 3P ,50 Hz complete all as specified and directed.
36Supply and fix in repair MCCB 100 Amps,16 KA,Adjustable type,415 volts, 3P, 50 Hz complete all as specified and directed.
37Supply and fix in repair MCCB 160 Amps,36 KA,Adjustable type,415 volts, 3P, 50 Hz complete all as specified and directed.
38Supply and fix in repair MCCB 200 Amps,36 KA,Adjustable type, 415 volts, 3P, 50 Hz complete all as specified and directed.
39Supply and fix in repair MCCB 250 Amps, 36 KA,Adjustable type, 415 volts,FP,50 Hz complete all as specified and directed.
40PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
41PCC 1:2:4 (nominal mix) type C1 using 20mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed.
42M & L for preparation of old cement coated surface, cleaning the surface of the RCC Pole (LT) above the ground level including coping area with 2 coats of ACC exterior emulsion paint over a coat of cement primer after preparation of surface and numbering of poles all as specified and as directed.
43M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt mixed with 10% paddy field earth, PCC pit chamber in PCC 1:3:6 type C-1 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
44M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber, including removing old earthing and all as specified and directed by Engr-in-Charge
45Repairing of LT Panels of any size by welding, grinding, etc & removing of rust and painting it with powder coated smoke grey colour with two layers after applying red oxide. Inserting rubber packing on doors, glands for cables, connecting to earthing.Note :- Angle Iron of any size, sheets, etc used for repairing will be measured & paid seperately.
46Repairing of APFC panels of any size by welding, grinding, etc & removing of rust and painting it with powder coating paint. Inserting rubber packing on doors, glands for cables, repair of power factor meter and protection device for capacitor, including capacitor bank wiring of 6 sqmm upto protection device of the panel.Note :- Replacement of capacitor banks, Angle Iron of any size, sheets, etc used for repairing will be measured & paid seperately.
47Supply and fix in repair heavy duty capacitor bank of capacity 10 KVAR ,440 volts ,50 Hz complete all as specified and directed.
48Supply and fix in repair heavy duty capacitor bank of capacity 25 KVAR ,440 volts ,50 Hz complete all as specified and directed.
49Supply and fix in repair heavy duty capacitor bank of capacity 30 KVAR ,440 volts ,50 Hz complete all as specified and directed.
50Supply & fixing bus bar chamber panel out door type 3.15 mm o f suitable size with 4 strips 200 Amps bus bar aluminium along with MCCB of 63 Amp FP adjustable type duly connected to aluminium strip at Incoming side with suiatble space for 2 incoming cables and outgoing of 2 cables .Bus bar fixed on insulators in zig-zag position, clearance in each strip and clearance at both side should not be less than 125mm with sufficient working space, height of bus bar chamber not less than 1 mtr, mounted MS angle 50x6mm, made of CRCA sheet 2mm thick outdoor type, powder coated, both side opening, shutter in two halves, cable opening from bottom side with indicators R,Y,B, hinges through out the length of shutter with half turn locking arrangement, including grouting in PCC, all as directed by Engr-in-Charge. Note : Size of Bus Bar chamber panel should not be Less than 900 MM X 600 MM X 350 MM. Make of Bus bar chamber should be CPRI approved
51Carry out materials /mechinaries,labour for fault finding of 1.1 KV LT under ground cable length 1.5 KM in case of cable fault such as short circuit/burn out/ earth fault etc complete all as specified and directed.(Note : Jointing Kit will be measured and paid separately)
52Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.15 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation design subject to approval of GE as per site requirement. The minimum height, width and depth of panel is 1000x1000x450 mm resprctively, minimum clearance from ground level is 450mm including removing old unserviceable item complete all as specified and directed and comprising of following :-
53Note :- (i) contractor shall provide CPRI certification of the panel.(ii) All items incorporated in panel is ISI marked or IS specification . Make for MCCB :-Schneider/L&T/Legrand/Standard. Make for CT :- Nippen/AE , Make of LED Lamp:- Teknic, Make for amp meter and volt ,meter :- AE/Kaycee
54MCCB 200 Amps,FP, 36 KA, Adjustable type,415 volts,50Hz-01 No
55MCCB 160 Amps,FP,36 KA, Adjustable type,415 volts,50Hz - 2 Nos
56MCCB 63 Amps,FP,36 KA, Adjustable type, 415 volts,50Hz-01 Nos
57Digital voltmeter,with VSS -01 set,Digital, Ammeter,with CTs & ASS-01 set
58LED phase indication lamps RYB-01 set
59Aluminium bus bar of adequate rating -01 set
60Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.15 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation design subject to approval of GE as per site requirement. The minimum height, width and depth of panel is 1200x1200x450 mm resprctively, minimum clearance from ground level is 450mm including removing old unserviceable item complete all as specified and directed and comprising of following :-
61Note :- (i) contractor shall provide CPRI certification of the panel.(ii) All items incorporated in panel is ISI marked or IS specification . Make for MCCB :-Schneider/L&T/Legrand/Standard. Make for CT :- Nippen/AE , Make of LED Lamp:- Teknic, Make for amp meter and volt ,meter :- AE/Kaycee
62MCCB 300 Amps,FP, 36 KA, Adjustable type,380 volts,50Hz-01 No
63MCCB 200 Amps,FP,36 KA, Adjustable type,380 volts,50Hz - 2 Nos
64MCCB 160 Amps,FP,36 KA, Adjustable type, 380 volts,50Hz-02 Nos
65Digital voltmeter,with VSS -01 set,Digital, Ammeter,with CTs & ASS-01 set
66LED phase indication lamps RYB-01 set
67Aluminium bus bar of adequate rating -01 set
68Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.15 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation design subject to approval of GE as per site requirement. The minimum clearance from ground level is 450mm including removing old unserviceable item complete all as specified and directed and comprising of following :-
69Note :- (i) contractor shall provide CPRI certification of the panel. (ii) All items incorporated in panel is ISI marked or IS specification. Make for MCCB :-Schneider/L&T/Legrand/Standard. Make for CT :- Nippen/AE , Make of LED Lamp:- Teknic, Make for amp meter and volt ,meter :- AE/Kaycee
70Incoming :-
71MCCB 4 Pole,630Amp 415V - 01 No
72Digital Volt meter 0 - 500V, size 96 x 96 mm square type with selector switch - 01 Set
73Digital Amp Meter 0 - 100 Amp, size 96x96 mm square type with selector switch - 01 Set.
74Indicator Lamps (LED type) showing R,Y, B phase - 01 set.
75Angle iron base frame as reqd size as per above panel, total leg height 900 mm and grouting in side PCC 150 mm legs and made out of ISA 5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.
76M & L for necessary grouting as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job
77Outgoing :-
78MCCB 4 Pole,320 Amp 415V - 01 No
79MCCB 4 Pole,100 Amp 415V - 06 No
80MCB 4 Pole, 63 Amps 415 Volt -06 Nos
81Taking out U/S control wiring complete from stabilizer of capacity above 25 KVA and up to 50 KVA single phase 230 volts make AE for unbalanced load and supply and providing new wiring loom complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including cable lugs, connectors, channels etc (additional items required to make stabilizers serviceable will be measured and paid separately under relevant items)
82All as per item no 38 but for capacity of above 50kva to 100kva.
83All as per item no 38 but for capacity of 400 kva to 500kva.
84Supply and fixing in repairs voltmeter digital type 30 to 600 volts of size 96x96mm square type complete all as specified and as directed.
85Supply and fixing in repairs printed control card circuit suitable for voltage stabilizers of AE Make and of any capacity
86Supply and fixing in repairs holder for printed control card circuit suitable for any make and capacity of voltage stabilizer including connections by soldering all as required or directed by Engr-in-charge.
87Supply and fixing in repairs micro switch (limit switch) suitable to cut off supply to control motors on high and low set limits as per sample.
88Supply and fixing in repairs synchronous motor single phase AC 230 volts suitable to work with voltage stabilizer above 25 KVA to 500 KVA capacity any Make AE/Blue line /Paradise/Vintech/Electric field/ Sheeba Info tech with torque above 5 Kg/sqcm up to 12 Kg/sqcm
89Supply and fixing in repairs gear suitable for synchronous motors to operate the shaft for variable dimmer stat.
90Supply and fixing in repairs indicator with bulb, red, yellow or green 230 volts as per sample
91M & L for repair/rewinding of burnt winding of servo voltage stabilizer/dimmer transformer of upto 100 kva for each phase, by dismantling the transformer assembly, removing burnt/damaged winding, rewinding with super enamelled copper conductor of suitable gauge and number of turns as per original design/manufacturer's specifications, providing and replacing insulation paper, sleeves, spacers and other insulating materials, varnishing and baking of winding, reassembling the transformer, making all electrical connections, carrying out insulation resistance and continuity tests, commissioning and proving satisfactory operation of the stabilizer/dimmer, complete all as specified and as directed by Engineer-in-Charge.\\"
92All as per item no 48 but for capacity of 400 kva to 500 kVA. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57004721
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 03-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Lt Panels Incl Apfc Panels, Servo Stabilizers And Connected Ug Cables, Overhead Lines At North Side Runway Of installation Hansa Under Ge (Nw) Vasco.(Tender Id No. 2026_Mes_784387_1)
Basic Detail
Tender No 8264/E8
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 13 Aug 2026
Submission Date 03 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
8264tenderdocuments.pdf
887127de-17c5-4f96-8142-35a1aefcb30d.html
BOQ_878938.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

8264tenderdocuments.pdf

html

887127de-17c5-4f96-8142-35a1aefcb30d.html

xls

BOQ_878938.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders